• Title/Summary/Keyword: Abdomen, CT

Search Result 201, Processing Time 0.037 seconds

Image Quality and Lesion Detectability of Lower-Dose Abdominopelvic CT Obtained Using Deep Learning Image Reconstruction

  • June Park;Jaeseung Shin;In Kyung Min;Heejin Bae;Yeo-Eun Kim;Yong Eun Chung
    • Korean Journal of Radiology
    • /
    • v.23 no.4
    • /
    • pp.402-412
    • /
    • 2022
  • Objective: To evaluate the image quality and lesion detectability of lower-dose CT (LDCT) of the abdomen and pelvis obtained using a deep learning image reconstruction (DLIR) algorithm compared with those of standard-dose CT (SDCT) images. Materials and Methods: This retrospective study included 123 patients (mean age ± standard deviation, 63 ± 11 years; male:female, 70:53) who underwent contrast-enhanced abdominopelvic LDCT between May and August 2020 and had prior SDCT obtained using the same CT scanner within a year. LDCT images were reconstructed with hybrid iterative reconstruction (h-IR) and DLIR at medium and high strengths (DLIR-M and DLIR-H), while SDCT images were reconstructed with h-IR. For quantitative image quality analysis, image noise, signal-to-noise ratio, and contrast-to-noise ratio were measured in the liver, muscle, and aorta. Among the three different LDCT reconstruction algorithms, the one showing the smallest difference in quantitative parameters from those of SDCT images was selected for qualitative image quality analysis and lesion detectability evaluation. For qualitative analysis, overall image quality, image noise, image sharpness, image texture, and lesion conspicuity were graded using a 5-point scale by two radiologists. Observer performance in focal liver lesion detection was evaluated by comparing the jackknife free-response receiver operating characteristic figures-of-merit (FOM). Results: LDCT (35.1% dose reduction compared with SDCT) images obtained using DLIR-M showed similar quantitative measures to those of SDCT with h-IR images. All qualitative parameters of LDCT with DLIR-M images but image texture were similar to or significantly better than those of SDCT with h-IR images. The lesion detectability on LDCT with DLIR-M images was not significantly different from that of SDCT with h-IR images (reader-averaged FOM, 0.887 vs. 0.874, respectively; p = 0.581). Conclusion: Overall image quality and detectability of focal liver lesions is preserved in contrast-enhanced abdominopelvic LDCT obtained with DLIR-M relative to those in SDCT with h-IR.

The study of MDCT of Radiation dose in the department of Radiology of general hospitals in the local area (일 지역 종합병원 영상의학과 MDCT선량에 대한 연구)

  • Shin, Jung-Sub
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.281-290
    • /
    • 2012
  • The difference of radiation dose of MDCT due to different protocols between hospitals was analyzed by CTDI, DLP, the number of Slice and the number of DLP/Slice in 30 cases of the head, the abdomen and the chest that have 10 cases each from MDCT examination of the department of diagnostic imaging of three general hospitals in Gyeongsangbuk-do. The difference of image quality, CTDI, DLP, radiation dose in the eye and radiation dose in thyroid was analyzed after both helical scan and normal scan for head CT were performed because a protocol of head CT is relatively simple and head CT is the most frequent case. Head CT was significantly higher in two-thirds of hospitals compared to A hospital that does not exceed a CTDI diagnostic reference level (IAEA 50mGy, Korea 60mGy) (p<0.001). DLP was higher in one-third of hospitals than a diagnostic reference level of IAEA 1,050mGy.cm and Korea 1,000mGy.cm and two-thirds exceeded the recommendation of Korea and those were significantly higher than A hospital that does not exceed a diagnostic reference level (p<0.001). Abdomen CT showed 119mGy that was higher than a diagnostic reference level of IAEA 25mGy and Korea 20mGy in one-third. DLP in all hospitals was higher that Korea recommendation of 700mGy.cm. Among target hospitals, C hospital showed high radiation dose in all tests because MPR and 3D were of great importance due to low pitch and high Tube Curren. To analyze the difference of radiation dose by scan methods, normal scan and helical scan for head CT of the same patient were performed. In the result, CTDI and DLP of helical CT were higher 63.4% and 93.7% than normal scan (p<0.05, p<0.01). However, normal scan of radiation dose in thyroid was higher 87.26% (p<0.01). Beam of helical CT looked like a bell in the deep part and the marginal part so thyroid was exposed with low radiation dose deviated from central beam. In addition, helical scan used Gantry angle perpendicularly and normal scan used it parallel to the orbitomeatal line. Therefore, radiation dose in thyroid decreased in helical scan. However, a protocol in this study showed higher radiation dose than diagnostic reference level of KFDA. To obey the recommendation of KFDA, low Tube Curren and high pitch were demanded. In this study, the difference of image quality between normal scan and helical scan was not significant. Therefore, a standardized protocol of normal scan was generally used and protective gear for thyroid was needed except a special case. We studied a part of CT cases in the local area. Therefore, the result could not represent the entire cases. However, we confirmed that patient's radiation dose in some cases exceeded the recommendation and the deviation between hospitals was observed. To improve this issue, doctors of diagnostic imaging or technologists of radiology should perform CT by the optimized protocol to decrease a level of CT radiation and also reveal radiation dose for the right to know of patients. However, they had little understanding of the situation. Therefore, the effort of relevant agencies with education program for CT radiation dose, release of radiation dose from CT examination and addition of radiation dose control and open CT contents into evaluation for hospital services and certification, and also the effort of health professionals with the best protocol to realize optimized CT examination.

Quality Assessment for Elbow CT scan by positioning and respiratory control (팔꿈치관절 CT검사에서 환자 자세 및 호흡에 따른 화질평가)

  • Lim, Jong-Chun;Park, Sang-Hyun;Lee, In-Jae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.7
    • /
    • pp.110-114
    • /
    • 2017
  • Because the arm can't be sutured due to fracture during a elbow CT scan, a CT scan is proceeded in a state of abdomen and L-spire are overlapped which beam hardening artifact is done many times, and it often lowers the quality of elbow CT images. So there are many difficulties in reading and due to increase in radiation dose from it, the number of patient's exposure keeps increasing. In this research, it plans to improve the quality of the images by avoiding overlap with abdomen, and increasing the number of photon overlapped with lung field which the line attenuation is relatively small. The way of experiment is based on patient's right elbow and place him as head first position, then place his elbow at L2-3 level in supine position, turn about 30 degrees to the left in non-control breathing and in supine position, and compared with full inspiration after overlapping with lung. After figuring out the average value and standard deviation data using Image J program 5 times each for 16, 128 channels, the evaluation is proceeded by measuring each of CNR, MSR are statistically analyzed using SPSS program. Therefore, through positioning and inspiration during elbow CT scan, the way of inspection minimized the exposure radiation dose, and seems to be meaningful in a way to improve the quality of the images.

A Case Report of Chronic Pancreatitis with Pseudocyst (가성 낭종을 동반한 만성 췌장염 환자에 대한 증례보고)

  • Kim, Yeon-mi;Kwak, Byung-Min;Kim, Sung-Lae;Lee, Jae-Min;Kim, Young-II;Lee, Hyun;Hong, Kwon-eui
    • Journal of Acupuncture Research
    • /
    • v.24 no.3
    • /
    • pp.231-238
    • /
    • 2007
  • Objectives : The purpose of this case is to report the improvement after treatment on the patient who has chronic pancreatitis with pseudocyst. Methods: We treated the patient with oriental and western medical treatment from 22nd February 2007 to 24th March 2007. We checked the patient with VAS score and Abdomen CT. Results : After treatment Pain, dyspepsia, itching sense and general body weakness were improved, VAS score changed from 10 to 0 and cystic lesion decreased on Abdomen CT. Conclusion : This case shows oriental medical treatment has useful effect on chronic pancreatitis. More research of chronic pancreatitis is needed.

  • PDF

A Case of Regression of Advanced Gastric Cancer by Herbal Medicine - A Retrospective Case Study with 8-years Follow-up (한약에 의한 진행성 위선암의 퇴축에 대한 증례보고 - 8년간의 추적조사를 통한 후향적 증례연구)

  • Park, Jeong-Seok;Lee, Yeon-Weol;Cho, Jung-Hyo;Son, Chang-Gue;Cho, Chong-Kwan;Yoo, Hwa-Seung
    • The Journal of Internal Korean Medicine
    • /
    • v.28 no.1
    • /
    • pp.193-198
    • /
    • 2007
  • Objective : The aim is to derive further studies evaluating the effectiveness of oriental medical treatment on advanced gastric cancer (AGC) patients. We present a case of a stage IV AGC patient who has survived over 8 years. Methods : We followed up all documents related to the patient. We prescribed to the patient HangAmDan (HAD) three times a day over five years. Abdomen CT was performed to evaluate the therapeutic efficacy. Results : The patient has survived over 8 years. Abdomen CT has shown complete regression. Conclusion : This case may give us the possibility of that oriental medical treatment offers potential benefits for patients with AGC.

  • PDF

Suspected Unilateral Renal Dysplasia in a Cat with Intermittent Hematuria (혈뇨를 보이는 고양이의 편측성 신장이형성 증례)

  • Han, Jae-Ik;Na, Ki-Jeong
    • Journal of Veterinary Clinics
    • /
    • v.32 no.1
    • /
    • pp.91-93
    • /
    • 2015
  • A 6-month-old, castrated male, Korean short-haired cat was referred with intermittent hematuria. Physical and laboratory examination including complete blood count and serum biochemistry profiles showed no specific findings. Ultrasonography revealed a cystic lesion of the mid-abdomen, which was approximately $2{\times}2cm$ in size. FNA cytology of cystic fluid showed numerous cholesterol crystals of varying size and shape and granulomatous inflammation. CT examination showed fluid-filled large cystic lesion in the left side of the abdomen. Taken together, this case was diagnosed as unilateral (left) renal dysplasia and cystic inflammation led by cholesterol crystallization in the left kidney.

A Study on Evaluation of Portal Vein by Utilizing MIP Reconstruction in the PC Environment after Abdomen CT of Hepatic Artery Embolization Patients (간동맥 색전술 환자의 복부단층촬영 후 PC 환경에서 MIP재구성영상을 이용한 간문맥평가에 관한 고찰)

  • Kim, Young-Keun;Jang, Young-Ill;Heo, Young-Nam
    • Journal of radiological science and technology
    • /
    • v.24 no.2
    • /
    • pp.13-17
    • /
    • 2001
  • When most patients are diagnosed with the quiet progressed hepatoma which often would make the operation impossible, the Interventional Radiology hepatic artery embolization is an extremely useful method for such patients. An existence of the malfunction is evaluated by gaining a portal vein image as a delayed phase image after injecting a contrast media into the superior mesenteric artery. However, it is difficult to make a definite judgement due to the extended exposure time with the peristalsis and the intestine gas obstructing the sharpness of the image when the Patient exposure time increases and due to the increased usage of contrast media and its side effect. The portal vein can be evaluated by obtaining the MIP image after reconstructing a 3-dimensional personal computer setting using the 2-dimensional from an enhancement abdomen CT image that is almost a requisite in operation to a hepatoma patient. Such method nay prevent a decrease in the quality of image based upon the time delay and intestine gas; also, because the patient exposure dose and contrast media usage may be reduced, it is a new, valuable way to decide the operational matter of hepatic artery embolization on a pre-angiography.

  • PDF

Parasitic Leiomyoma with Lymphatic Dilatation in Trocar Port-Site of Abdominal Wall: A Case Report (트로카 삽입 부위에 생긴 림프관 확장을 동반한 기생 평활근종: 증례 보고)

  • Gayoung Jeon;Seo Young Park
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.280-285
    • /
    • 2023
  • Uterine leiomyoma is the most common benign pelvic tumor in female and being symptomatic is an indication for surgical removal. As laparoscopic surgery has been developed, some cases related to parasitic leiomyomas in the port site have been reported. A 40-year-old female who a history of previous laparoscopic surgery to remove uterine myoma 2 years ago visited in outpatient clinic of general surgery with palpable mass in left lower abdomen. Contrast enhanced abdomen CT and pelvis MRI were done to evaluate the mass. It was diagnosed parasitic leiomyoma in pathologic study after surgical removal and parasitic leiomyoma should be considered when patient visited presenting abdominal mass with the history of laparoscopic myomectomy.

Geometric Calibration of Cone-beam CT System for Image Guided Proton Therapy (영상유도 양성자치료를 위한 콘빔 CT 재구성 알고리즘: 기하학적 보정방법에 관한 연구)

  • Kim, Jin-Sung;Cho, Min-Kook;Cho, Young-Bin;Youn, Han-Bean;Kim, Ho-Kyung;Yoon, Myoung-Geun;Shin, Dong-Ho;Lee, Se-Byeung;Lee, Re-Na;Park, Sung-Yong;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.209-218
    • /
    • 2008
  • According to improved radiation therapy technology such as IMRT and proton therapy, the accuracy of patient alignment system is more emphasized and IGRT is dominated research field in radiation oncology. We proposed to study the feasibility of cone-beam CT system using simple x-ray imaging systems for image guided proton therapy at National Cancer Center. 180 projection views ($2,304{\times}3,200$, 14 bit with 127 ${\mu}m$ pixel pitch) for the geometrical calibration phantom and humanoid phantoms (skull, abdomen) were acquired with $2^{\circ}$ step angle using x-ray imaging system of proton therapy gantry room ($360^{\circ}$ for 1 rotation). The geometrical calibration was performed for misalignments between the x-ray source and the flat-panel detector, such as distances and slanted angle using available algorithm. With the geometrically calibrated projection view, Feldkamp cone-beam algorithm using Ram-Lak filter was implemented for CBCT reconstruction images for skull and abdomen phantom. The distance from x-ray source to the gantry isocenter, the distance from the flat panel to the isocenter were calculated as 1,517.5 mm, 591.12 mm and the rotated angle of flat panel detector around x-ray beam axis was considered as $0.25^{\circ}$. It was observed that the blurring artifacts, originated from the rotation of the detector, in the reconstructed toomographs were significantly reduced after the geometrical calibration. The demonstrated CBCT images for the skull and abdomen phantoms are very promising. We performed the geometrical calibration of the large gantry rotation system with simple x-ray imaging devices for CBCT reconstruction. The CBCT system for proton therapy will be used as a main patient alignment system for image guided proton therapy.

  • PDF

Discrepancy of Bone Metastases between F-18 FDG PET/CT and Bone Scan in a Patient with Prostate Cancer (전립선암에서 골전이 진단에 대한 F-18 FDG PET/CT와 골스캔의 불일치)

  • Choi, Seung-Jin;Kim, Chul-Soo;Byun, Sung-Su;Hyun, In-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.5
    • /
    • pp.275-278
    • /
    • 2006
  • We report the case of a 73-year-old man who had prostate cancer with bone metastases. Tc-99m HDP Whole body bone scan revealed multiple areas of increased bony uptake consistent with widespread bone metastases. F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) demonstrated mild F-18 FDG uptake in the lymph nodes of neck, abdomen, and pelvis. However, abnormal F-18 FDG uptake was not seen in the skeletal system. Biopsy and immunohistochemical stains of left supraclavicular mass showed metastatic prostate adenocarcinoma. Currently, there are a few reported cases of F-18 FDG PET/CT evaluation of bone metastases in prostate cancer. We discuss the discrepancy between F-18 FDG PET/CT and bone scan in the detection of osseous metastases of prostate cancer.