• Title/Summary/Keyword: ATS system

Search Result 136, Processing Time 0.038 seconds

DMI Display implemented as single layout based on ERTMS specification for Integrated Onboard Signaling System (통합 열차제어 신호시스템을 위한 단일 레이아웃의 ERTMS 기반 DMI 화면의 설계 및 구현)

  • Jung, Ji-Chan;Kim, Hyung-Hoon;Cho, Yong-Gee
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.251-254
    • /
    • 2011
  • This paper describes the design and implementation of the DMI display based on ERTMS specification for the Integrated Onboard Signaling System (IOSS). IOSS is consists of ATS, ATC, and ATP based on ERTMS/ETCS Level 1. We propose an improved DMI display design which has single layout concept for the IOSS. When a train is in the ATS, ATC, or ATP railway section, it is protected by the ATS, ATC, or ATP equipment, respectively. Therefore, DMI should display the different information according to the each signaling system. We design DMI display implemented as single layout for ATP, ATS and ATC information. This single layout display has a well integrated look and feel using the ERTMS specification and layout. This is for the driver to perceive the information easily and not to experience inconvenience resulting from the sense of difference when the train crossed into the different signaling section. Finally, we show the implementation result following this concept.

  • PDF

Model-based Development of Integrated Onboard Signaling System (모델기반 통합 차상신호시스템 개발)

  • Han, Jae-Mun;Kim, Seok-Heon;Cho, Yong-Gi
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.245-250
    • /
    • 2011
  • ERTMS/ETCS Level 1 ATP, ATC and ATS are Signaling Systems adopted in korea. For operating in three different trackside signaling systems, train must have individual onboard signaling systems, ATP, ATC and ATS. Three signaling systems in one train is the main cause to increase installation and maintenance cost. Also it is need more effort to change a onboard signaling system depend on the trackside signaling system. those things should lead to decrease efficiency of the onboard signaling system. one integrated onboard signaling system for ATP, ATC and ATS is the good solution for those problems. IOSS is an integrated Onboard Signaling System and still developing. In this paper, we introduce the methodology of model-based development of IOSS. IOSS has one superviser process and several functional blocks to process individual signaling system s. Rhapsody which is CASE tool is used to construct the structure and develop the software for IOSS.

  • PDF

Analysis for Catenary Voltage of The ATs-Fed AC Electric Railroad System (교류전기철도 급전시스템의 전차선 전압해석)

  • 이승혁;정현수;김진오
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.490-496
    • /
    • 2002
  • This paper presents exact Autotransformers(ATs)-fed AC electric Railroad system modeling using constant current mode far locomotives. An AC electric railroad system is rapidly changing single-phase load, and at a feeding substation, 3-phase electric power is transferred to paired directional single-phase electric power. As the train moves along a section of line between two adjacent ATs. The proposed AC electric railroad system modeling method considers the line self-impedances and mutual-impedances. The constant current mode model objectives are to calculate the catenary and rail voltages with the loop equation. When there are more than one train in the AC electric railroad system, the principle of superposition applies and the only difference between the system analyses for one train. Finally, this paper shows the general equation of an AC electric railroad system, and that equation has no relation with trains number, trains position, and feeding distance.

  • PDF

Analysis for Catenary Voltage of The ATs-Fed AC Electric Railroad System (단권변압기 교류전기철도 급전시스템의 전차선 전압해석)

  • 정현수;이승혁;김진오
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.9
    • /
    • pp.493-499
    • /
    • 2003
  • This paper presents exact Autotransformers(ATs)-fed AC electric Railroad system modeling using constant current mode for locomotives. An AC electric railroad system is rapidly changing single-phase load, and at a feeding substation, 3-phase electric power is transferred to paired directional single-phase electric power. As the train moves along a section of line between two adjacent ATs. The proposed AC electric railroad system modeling method considers the line self-impedances and mutual-impedances. The constant current mode model objectives are to calculate the catenary and rail voltages with the loop equation. When there are more than one train in the AC electric railroad system, the principle of superposition applies and the only difference between the system analyses for one train. Filially, this paper shows the general equation of an AC electric railroad system, and that equation has no relation with trains number, trains position, and feeding distance.

Complement of the Interlocking Logic of ATS for Heterogenous Railway Signaling Systems (이종 철도신호시스템을 위한 기존 자동열차정지 연동로직의 보완)

  • Jeong, Rag-Gyo;Kim, Baek-Hyun;Kang, Seok-Won;Byun, Yeun-Sub;Park, Geon-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.702-708
    • /
    • 2016
  • The railway signaling system has evolved to maximize its safety and maintainability based on the experiences in the construction and operation of railway systems. The newly developed systems was established to cope with the changes in an operating environment. In the process of a transition to the new system, both the existing ATS (Automatic Train Stop) and new ATP/ATO (Automatic Train Protection/Automatic Train Operation) systems are operating simultaneously in parallel. In this situation, modifications of the conditions of the interlocking diagram and logic are necessarily required on the existing ATS systems due to the frequent improvements in signaling equipment. This paper reports the enhancement of safety and operational efficiency of the system through an improvement of the security and the interlocking conditions of the existing ATS systems. The independent display of signals for each track was ensured to avoid giving the effect of On/Off signals for the selected track on the opposite side, and the security was improved by adjusting the position and interlocking conditions. In addition, the increased traffic density of railway systems was achieved by removing the unnecessary conditions and detailed signal display, which resulted in enhanced operational efficiency.

Efficacy of the Antibiotics Chosen by ATS Guideline in the Treatment of Korean Patients with Community-acquired Pneumonia Admitted to a Tertiary Hospital (3차 병원에 입원한 한국 지역사회획득 폐렴 환자에서 미국흉부학회 추천 항생제의 유용성)

  • Oh, Sung-Yong;Park, Sang-Joon;Kang, Kyeong-Woo;Koh, Young-Min;Suh, Gee-Young;Chung, Man-Pyo;Kim, Ho-Joong;Choi, Dong-Chull;Kwon, O-Jung;Rhee, Chong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.4
    • /
    • pp.460-470
    • /
    • 1999
  • Background : In 1993, American Thoracic Society (ATS) recommended a guideline for the initial management of adults with community-acquired pneumonia(CAP). However, etiologic organisms and medical system in Korea seem to be different from those in Western countries. Retrospective analysis was done to evaluate the efficacy of antibiotics chosen by ATS guideline in the treatment of Korean patients with CAP admitted to a tertiary university medical center. Methods : Hospitalized patients with CAP at Samsung Medical Center from April 1997 through March 1998 were retrospectively reviewed. Patients who fulfilled all of the following criteria were included in this study : (1) fever ${\geq}38^{\circ}C$ (2) purulent sputum (3) pulmonary infiltrates on chest X-ray. Patients were classified as : 1) ATS group ; patients whose initial antibiotics were chosen by ATS guideline 2) Non-ATS overuse group ; additional antibiotics administered more than those of ATS guideline, and 3) Non-ATS underuse group ; initial antibiotics were insufficient to ATS guideline. Response of empirical antibiotics and etiologic organisms of 3 groups were identified. Results : Sixty-four patients were enrolled. Thirty-six patients were classified into ATS group, 10 patients Non-ATS overuse group, and 18 patients Non-ATS underuse group. Thirty-three patients of 36 ATS group, 9 patients of 10 Non-ATS overuse group, and 14 patients of 18 Non-ATS underuse group showed improvement by initial empirical antibiotics. There was no statistical difference in antibiotic response between 3 groups (p>0.05). S. pneumoniae (12.5%), K. pneumoniae (9.4%), and P. aeruginosa (4.7%), Mycoplasma (3.1%) were the most commonly isolated organisms. In 18 patients with severe CAP, P. aeruginosa was isolated only in 1 patient and Legionella organism not isolated. Conclusion : Initial empirical antibiotics chosen by ATS guideline were effective in the management of Korean patients with CAP admitted to a tertiary hospital. However, well-designed large-scale prospective study is needed to identify etiologic organisms and choose an adequate initial empirical antibiotics in Korean adults patient with severe CAP.

  • PDF

Evaluation of the Resolution Characteristics by Using ATS 535H Phantom for Ultrasound Medical Imaging (초음파 의료영상에서 ATS 535H 팬텀을 이용한 해상력 특성 평가)

  • Jung-Whan, Min;Hoi-Woun, Jeong;Hea-Kyung, Kang
    • Journal of radiological science and technology
    • /
    • v.46 no.1
    • /
    • pp.15-21
    • /
    • 2023
  • This study was purpose to assessment of the resolution characteristics by using ATS 535H Basic quality assurance (QA) phantom for ultrasound. The ultrasound equipment was used Logiq P6 (Ultrasound, GE Healthcare System, Chicago, IL, USA). And the ultrasound transducer were used Convex 4C (4~5.5 MHz), Linear 11L (10~13 MHz), Sector 3SP (3~5.5 MHz) probe. As for the noise power spectrum (NPS) comparison results by using ATS 535H Basic QA ultrasound phantom and Convex 4C, Linear 11L, Sector 3SP probe. The NPS value of the Convex 4C probe image was 0.0049, Linear 11L probe image was 0.0049, Sector 3SP probe image was 0.1422 when the frequency is 1.0 mm-1. The modulation transfer function (MTF) comparison results by using ATS 535H Basic QA ultrasound phantom and Linear 11L probe the MTF value of the 3 cm focus image was 0.7511 and 4 cm focus image was 0.9001 when the frequency is 1.0 mm-1. This study was presented characteristics of spatial resolution a quantitative evaluation methods by using ultrasound medical images for QA of ultrasound medical QA phantom. The quality control (QC) for equipment maintenance can be efficiently used in the clinic due to the quantitative evaluation of the NPS and MTF as the standard methods. It is meaningful in that it is applied mutatis mutandis and presented the results of physical resolution characteristics of the ultrasound medical image.

A study of eatablishing ETCS Level 1 to speed up conventional lines (기존선 속도향상을 위한 ETCS Level 1 구축방안 연구)

  • Yoon, Yong-Ki;Jeong, Rag-Gyo;Kim, Chae-Duck
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.666-670
    • /
    • 2011
  • ATS(Automatic Train Stop)s are is effected by track environment, signal distance and train braking distance. So onboard signaling systems such as ATP(Automatic Train Protection) are installed on conventional lines by some train operation companies. With the mixed signalling, the onboard signaling system is overlaid on a conventional line with ATS, it is possible to run the line with conventional trains and ATP trains and to use the advantages of ATP(higher speed or more trains on the line). This paper includes guidelines a mixed signalling(ETCS and ATS) system architecture, operation concepts and infill balise installation.

  • PDF

Development of E.C.G. Telemetry System Using Digital Communication Method (디지탈 통신방식을 이용한 심전도 텔레메트리 시스템의 개발)

  • 이준하;이상학;신현진;유동수;서희돈;박정연
    • Progress in Medical Physics
    • /
    • v.5 no.2
    • /
    • pp.27-34
    • /
    • 1994
  • In this study, we developed E.C.G telemetry system by using a digital communication method. This system is composed of a number of Ambulatory Telemetry System(ATS)'s that use for the same frequency and one center monitoring system(CMS) utilized the personal computer. The purpose of the ATS is, Therefore, to present for acqusition ECG data and transmitting to CMS. The ATS hardware is based on one chip microprocessor (8096) included A/D convert, ECG pre amplifier, ID-decoder, TRX Gateway and FM TRX module. Using the PC can be convinet to processing and deposite for long terms continued patient data.

  • PDF

A Study on the Hazard Identification and Risk Mitigation for ATSRX Using Hazard and Operability Study (HAZOP Study를 사용한 ATSRX의 위험원도출 및 리스크 완화에 관한 연구)

  • LEE Jun-Ho;LEE Kang-Mi;KIM Yong-Kyu;SHIN Ducko
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.6 s.31
    • /
    • pp.533-538
    • /
    • 2005
  • In this paper we identity the hazard using HAZOP study for ATSRX which is a subsystem of the ATP system, and we study a safety management method for the mitigation of the risk to the acceptable level. ATSRX is a device that make a train which has a ATP system operate in ATS line. For this ATSRX send a induction signal with ATS system to vehicle controller. Thus ATSRX can be said a safety equipment that makes a train operate safely. In order to identify the hazard for the internal faults in ATSRX system, we employ HAZOP study method which is recommended as hazard identification in IEC 62278, RAMS requirements in railway signal, and also it provide the detail activity in IEC 61882. Thus, in this paper we perform HAZOP study based on ATSRX related standards and using the assessment of the identified hazard we study a method to guarantee the system safety through the change of the design to mitigate the risk to the acceptable level.