• 제목/요약/키워드: AT(auto transformer)

검색결과 28건 처리시간 0.021초

교류 AT 급전계통에서의 단권변압기 설치위치의 최적화 (Location of Auto Transformer in AC AT Feeding System)

  • 한문섭;이장무
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1248-1250
    • /
    • 2002
  • AC AT feeding system is possible to do the long distance feeding due to compensate the voltage drop. Nowaday this is a typical and efficient type all over the world in high speed train and heavy transport capacity. Normally a Auto-transformer is installed at regular internal (5 to 10km) between Substation and Sectioning post, this study is reviewed the voltage drop according to train movement and the optimal location of auto transformer, and provided the efficient feeding configuration.

  • PDF

345[kV] 주변압기 3차측 영상전압 발생원인 분석 및 대책에 관한 연구 (A Study on the Occurrence Cause of the Zero Sequence Voltage at Tertiary Side of 345[kV] Main Transformer)

  • 우정욱;권동진
    • 조명전기설비학회논문지
    • /
    • 제24권9호
    • /
    • pp.150-158
    • /
    • 2010
  • We had experienced the several system failures which were concerned about zero sequence voltages at the tertiary side of 345[kV] transformers. In this paper, we had considered the zero sequence voltage and its reduction methods at the 345[kV] auto-transformer tertiary. For analysis, we used EMTP(Electro-Magnetic Transients Program). The calculation results by EMTP were compared with the measured data of the field tests. From the calculation and the field tests, we had verified that it is due to pre-saturation characteristics of the potential transformer. So, we had improved its saturation characteristics and applied it at real site. After improvements, we could reduce the zero sequence voltage below the setting level of the relay.

AT 교류 철도급전계통 내 다수 열차 운행시 새로운 계통해석 알고리즘 연구 (Applying New Algorithm on AC Auto-Transformer Feeding System under Multiple Trains Operating)

  • 전용주;추동욱;전명수;임성정;김재철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.712-719
    • /
    • 2000
  • This paper presents a new algorithm to analyze a train voltages of multi-trains in auto-transformer-fed AC railway systems, using electrical equivalent change. The train current will be divided into circulation and return currents, and these current values are the same. By evaluating each current independently, the result will be more precise. The train current flows through the all auto-transformer corresponding to track impedance. In analyzing the railway system, the algorithm is based on the K.C.L, K.V.L, superposition and circuit separation method. Multi-train's voltages are determined by calculating the catenary voltage at each train's position and adding up these train's voltage drop. Case studies use a field operational data, show that tile proposed method is easily applied.

  • PDF

Two-Phase Hybrid Forward Convertor with Series-Parallel Auto-Regulated Transformer Windings and a Common Output Inductor

  • Wu, Xinke;Chen, Hui
    • Journal of Power Electronics
    • /
    • 제13권5호
    • /
    • pp.757-765
    • /
    • 2013
  • For conventional interleaved two-phase forward converters with a common output inductor, the maximum duty cycle is 0.5, which limits the voltage range and increases the difficulty of the transformer's optimization. A new two-phase hybrid forward converter with series-parallel auto-regulated transformer windings is presented in this paper. With interleaved control signals for the two phases, the secondary windings of the transformers can work in series when the duty cycle is larger than 0.5, and they can work in parallel when duty cycle is lower than 0.5. Therefore, the maximum duty cycle is extended and the turns ratio of the transformer can be optimized. Duty cycle dependent auto-regulated windings result in the steady states of the converter being different in different duty cycle ranges (D>0.5 and D<0.5). Fortunately, the steady state gains of the proposed hybrid converter are identical at different duty cycle ranges, which means a stepless shift between two states. A prototype is built to verify the theoretical analysis. A conventional control loop is compatible for the whole input voltage range and load range thanks to the stepless shifting between the different duty cycle ranges.

개방-델타 단권선 변압기를 이용한 새로운 다중 펄스 정류기 시스템 (New Multi-pulse Rectifier Systems Using An Open-Delta Auto-Connected Transformer)

  • 강문식;우병옥
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권5호
    • /
    • pp.278-285
    • /
    • 1999
  • This paper proposes new 12 and 24-pulse rectifier systems using an open-delta auto-connected transformer. This approach employs two static converters to operate it at higher than utility line frequencies and to provide multi-pulse operation. By operating magnetic components at a higher frequency, higher power density can be achieved. A unique feature of the proposed approach is that the magnetic components for the dc-side are also exposed to a higher frequency and these components too are reduced in size. The switching frequency and its harmonic components are absent in the utility input line current. The VA ratings of the transformer and static converter are 0.236/0.292 [pu] and 0.11/0.18 [pu] in 12 and 24-pulse rectifier system, respectively. A finer grade of steel or alternatives can be deployed to increase performance and reduce size further. Analysis, simulations, simulations, design example, and experimental results for a 480[V], 10{kVA] prototype system are presented.

  • PDF

A Zigzag Connected Auto-Transformer Based 24-Pulse AC-DC Converter

  • Singh, Bhim;Gairola, Sanjay
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.235-242
    • /
    • 2008
  • In this paper, a 24-pulse AC-DC converter is designed, modeled, simulated, and developed to feed non-isolated varying loads. The proposed AC-DC converter configuration consists of an auto-transformer based on zigzag connection to overcome current harmonic problems in AC mains. It improves power quality at AC mains and it meets IEEE-519 standard requirements at varying loads. A set of power quality indices on input AC mains and on DC buses for a load fed from 6-pulse and 12-pulse AC-DC converters is also given to compare their performance. It is observed that input current total harmonic distortion(THD) of less than 8% is possible with the proposed topology of AC-DC converter at varying loads.

제작소가 상이한 단상 주변압기 병행 운전시 불평형전압의 검토 (The Calculation of Unbalanced Voltage on the tertiary bus of a single phase auto transformer in case of Parallel Operation with Different Manufacturer)

  • 심응보;우정욱;곽주식;조성훈;허용호;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.458-460
    • /
    • 2001
  • This paper described the unbalanced voltage on the tertiary bus of a single Phase auto transformer in the case of parallel operation with different manufacturer at each Phase. The unbalanced capacitances between primary to secondary winding, secondary to tertiary winding and primary to tertiary winding makes unbalanced bus voltage in the tertiary bus side. The unbalanced voltage let the surge arrester to operate in the power frequency range, and it causes the arrester to burn out. The failure of the arrester at one phase makes line to ground fault, which lead to the surge arrester failure of the other two phase on the tertiary bus.

  • PDF

국내 교류 전기철도 급전계통 보호용 과전류 계전기 모델링 및 과부하 보호 협조에 관한 연구 (A Study on the Overcurrent Relay Modeling and Protective Coordination for Overload in Domestic AC Electrical Railway System)

  • 김현동;조규정;허승훈;김철환
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1121-1127
    • /
    • 2016
  • In this paper, modeling of overcurrent relay(OCR) to protect domestic AC electric railway Auto Transformer(AT) feeding system and operation characteristic analysis on overload condition are described. The target system of this paper is actual site where overload trip of circuit breaker occurs frequently. Because this AT feeding system is made of parallel single track which had a load(electric train) respectively, and is connected with only T phase of Scott Transformer. In addition, this system has been feeding 66kV voltage by KEPCO, not 154kV. We focus on protective coordination of Scott Transformer primary side and secondary side OCR for Korea single track AC electrical railway system in operation currently. We modeled single track AT feeding system and OCR. Also we performed faults and overload analysis for verification of OCR's setting values and system modeling. To analyze above mentioned research, we used PSCAD/EMTDC software tool.

전기철도계통에 순간전압강하 보상장치 적용에 관한 연구 (A Study on the Application of the DVR in AC Electric Traction System)

  • 최준호;김태수;김재철;문승일;남해곤;정일엽;박성우
    • 조명전기설비학회논문지
    • /
    • 제17권6호
    • /
    • pp.95-104
    • /
    • 2003
  • 전기 철도계통은 기존 전력계통과 달리 단상, 대용량 부하로 필연적으로 전압강하, 전압불평형 및 고조파 왜곡 등의 전력품질의 문제가 발생한다. 이러한 문제점 중 상시전압강하는 전력품질의 가중 중요한 요소로서 SVC(Static Var Compensator) 또는 STACOM(Static Compensator)를 설치하여 전압강하를 보상하는 연구가 수행되었다. 또한 순시전압강하는 고속으로 운전중인 철도차량의 제어 및 안전에 상당한 영향을 미칠것으로 예상된다. 따라서 본 논문에서는 AT(Auto Transformer)급전계통에 적용되는 순간전압강하 보상장치에 관한 연구를 수행하였다. 순간전압강하에 의한 철도차량의 과도해석을 위해 전원, 철도급전변압기, AT, 철도선로 및 철도 차량부하를 모델링 하였다. 또한 순간전압강하 발생시 철도차량부하의 과도특성을 분석하였고 이를 보상하기위한 순간전압강하 보상장치 (DVR:Dynamic Voltage Restorer)를 제안하였다. 순간전압강하 보상 시뮬레이션 결과, 순간전압강하 보상장치의 철도급전계통의 적용은 상당히 유용함을 알수있었다.

인접한 AT와 BT급전계통에서의 연장급전방안 (Consideration on a extended feeding between AT and BT Feeding System)

  • 한문섭;이장무;정호성;김주락
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1361-1363
    • /
    • 2004
  • 전기철도에서는 한 전철변전소에서 급전이 용이하지 못할 경우 인근변전소에서 연장급전을 수행한다. 특히 AT(Auto Transformer)와 BT(Booster Transformer)급전시스템이 인접한 경우 연장급전운영을 하기 위한 방안 및 전기적인 요소를 급전계통모의를 통하여 검토하여 그 급전가능성을 제시한다.

  • PDF