• 제목/요약/키워드: ASME T형 스트레이너

검색결과 2건 처리시간 0.016초

연구용 원자로 냉각계통의 ASME 스트레이너 설계 및 성능시험 (Design and Test of ASME Strainer for Coolant System of Research Reactor)

  • 박용철;박종호
    • 한국유체기계학회 논문집
    • /
    • 제2권3호
    • /
    • pp.24-29
    • /
    • 1999
  • The ASME strainers have been newly installed at the suction side of each reactor coolant pump to get rid of the foreign materials which may damage the pump impeller or interfere with the coolant path of fuel flow tube or primary plate type heat exchanger. The strainer was designed in accordance with ASME SEC. III, DIV. 1, Class 3 and the structural integrity was verified by seismic analysis. The screen was designed in accordance with the effective void area from the result of flow analysis for T-type strainer. After installation of the strainer, it was confirmed through the field test that the flow characteristics of primary cooling system were not adversely affected. The pressure loss coefficient was calculated by Darcy equation using the pressure difference through each strainer and the flow rate measured during the strainer performance test. And these are useful data to predict flow variations by the pressure difference.

  • PDF

일차 냉각계통 스트레이너에 대한 내진 건전성 평가 (Seismic Evaluation for Strainer in the Primary Cooling System)

  • 정철섭
    • 한국전산구조공학회논문집
    • /
    • 제13권3호
    • /
    • pp.295-304
    • /
    • 2000
  • 본 연구의 목적은 지진하중에 대한 응력 해석을 수행하여 ASME, Class 3 설계요건에 따라 스트레이너의 구조건진성을 평가하는 것이다. 스트레이너에 대한 설계요건이 ASME 코드 내에 명백하게 규정되어 있지 않기 때문에 본체는 밸브 설계요건인 ND-3500을 적용하고, 양쪽 플랜지 연결부는 배관 설계요건 중 ND-3658.3을 적용하였으며, 하단의 덮개 플랜지는 Appendix XI에 따라 설계 및 해석을 수행하였다. 본 연구에서는 T형 스트레이너를 쉘로 모델링하여 유한요소법을 사용하여 지진하중에 의해 스트레이너가 응답하는 모드 형상 및 고유진동수를 계산하여 충분히 강건한 구조물임을 입증한 후 정적 해석을 수행하여 주관과 분기 관이 접합하는 연결부위와 같은 위험단면에서의 막응력과 굽힘 응력을 구하였다. 각 하중조합에 대해 코드에서 규정하고있는 허용 값과 비교한 결과 스트레이너는 지진하중이 작용하는 경우 구조적 건전성을 유지하고 있음을 확인하였다. 아울러 인접 배관을 연결해주는 플랜지 연결부의 응력을 규정에 따라 구한 후 설계요건에 의한 허용 값과 비교하여 건전성을 만족함을 알 수 있었다.

  • PDF