• Title/Summary/Keyword: ASD method

Search Result 95, Processing Time 0.035 seconds

Evaluation of Structural Integrity of the ISO-based Moon Pool Type Diver Boats (ISO 기반 Moon Pool형 다이버 보트 구조 건전성 평가)

  • Kang, Byoung-mo;Oh, Woo-jun;Na, Hyun-ho;Choi, Ju-seok
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.5
    • /
    • pp.597-603
    • /
    • 2018
  • This Study investigates the Structural Integrity of Boats for Divers, given increased demands for Underwater and Recreational use. We conducted research on a Small Catamaran with a Moon Pool in the center of the Hull, using the Finite Element Method to calculate allowable stress based on the ISO Rule. We computed the coefficients defined in ISO 12215-5 and TC118.1225-7, and determined the suitability of using the ISO Standard and Allowable Stress Design method (ASD) by applying Longitudinal Bending Moment, Torsional moment, and Bottom Slamming Load. We also applied the Ultimate Strength Design Method (LFRD) using Finite Element Analysis (FEA). As a Result of this Research, it was found that ships with a Moon Pool do have Structural Integrity according to their Design in accordance with ISO and KR Regulations.

Minimally Invasive Cardiac Surgery through A Small Right Parasternal Incision (개실술에서 우측흉골우연소절개법을 이용한 최소침투수술)

  • 공준혁;이응배;조준용;전상훈;장봉현;이종태;김규태
    • Journal of Chest Surgery
    • /
    • v.33 no.9
    • /
    • pp.723-728
    • /
    • 2000
  • Background: Minimally invasive techniques for open heart surgery are widely accepted in these days. There are minimally invasive approaches by the right or left parasternal incision and another approaches by mini-sternotomy of upper or lower half or sternum. We report the safety and efficacy of minimally invasive technique with right parasternal incision compared with the routine full sternotomy. Material and Method: From April 1997 through February 1999, 20 patients(Group A) underwent minimally invasive cardiac operations. We chose 41 patients(Group B) whose preoperative diagnosis were the same and general conditions were similar and who underwent routine full sternotomy before April 1997. We compared A group and B group in many aspects. We performed routine full median sternotomy in B group but we did a minimally invasive technique through a small right parasternal incision in A group. Result: mean age was 36.1 years in both groups. In disease entities, there were 11 cases of ASD, 9 cases of mitral valve disease in group A, and 16 cases of ASD, 25 cases of mitral valve diseases in group B. In ASD, operation time, cardiopulmonary bypass time of aortic occulusion time were 263 min, 82 min, and 41 min in group A and 180 min, 53 min, and 32 min in group B. In mitral valve disease, operation time, cardiopulmonary bypass time and aortic occlusion time were 267min, 106 min, and 70min in A group and were 207 min, 82 min, and 69 min in group B. There were significant differences in operation time, CPB time, and ACC time between group A and group B. There was a significant difference in the amount of bleeding in postoperative day 1 between group A and group B of mitral diasease. However, there was no significant difference in the amount of bleeding in other comparisons. Mean length of incision was 8.7 cm in group A. There was no significant difference in postoperative complications between A group and B group. There was no mortality in either group. Conclusion: We conclude that this minimally invasive technique with right parasternal incision is cosmetically excellent but it is not effective in reducing operative time and there was no significant difference in recovery time and postoperative complications compared with routine full sternotomy.

  • PDF

The Evaluation of Structural Stability of Corrugated Steel Plate Method applied in High-Speed Railway Vertical Tunnel Structures (고속철도 수직구 터널구조물에 적용된 파형강판공법의 구조적 안정성 검토)

  • Chung, Jee-Seung;Shin, Hwa-Cheol;Kim, Jin-Gu
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.2
    • /
    • pp.64-69
    • /
    • 2016
  • In this paper, structural analysis of High-Speed railway vertical tunnel structures was performed to verify the structural stability. The corrugated steel plate method was applied to the vertical tunnel structures for its simple construction method and low cost. The structural stability of Wall, Connection and Storage section was performed with LRFD and ASD design method at joint part, buckling, stress and plastic hinge. From the results, all of vertical tunnel structures shown the structural stability regardless of design method and structure types. So, the application of corrugated steel plate in vertical tunnel structures instead of cast-in-placed concrete was quite enough.

Study on Ultra Precise Position Control of Servomotor using Analog Quadrature Encoder (정현파 엔코더를 이용한 서보전동기의 초정밀 위치제어에 관한 연구)

  • Kim J.C.;Kim J.M.;Kim C.W.;Choi C.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.260-264
    • /
    • 2005
  • This paper describes the ultra precise position control of servo motor using sinusoidal encoder based on 'Arcsine Interpolation Method'. First, the paper theoretically analyzes and verify throughout experiments, the relationship between A/D converter input ripple and the total resolution to measure the precise position. Second, this paper presents a way to compensate the total gain and offset error by utilizing a low cost programmable differential amp, by which without any special expensive equipments they are easily on-line tuned and effectively compensated. Lastly, it was compared to servomotor position control characteristics using digital incremental 50,000ppr encoder. The test results show that, with much cheaper sinusoidal encoder, the proposed method exhibits better performance both in position control and ASD applications than the 50,000ppr optical encoder.

  • PDF

An Improvement On-Line Failure Diagnosis of DC Link Capacitor in PWM Power Converters (PWM 전력 컨버터에서 DC 링크 커패시터의 개선된 온라인 고장 진단)

  • Shon, Jin-Geun;Na, Chae-Dong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.40-46
    • /
    • 2010
  • DC link electrolytic capacitors are widely used in various PWM power converter system, such as adjustable speed driver(ASD) or DC/DC converter. Electrolytic capacitors, which is the most of the time affected by aging effect, plays a very important role for the power electronics system quality and reliability. This objective of this paper is to propose a improvement method to detect the rise of equivalent series resistor(ESR) in order to realize the online failure prediction of electrolytic capacitor for DC link of PWM power converter. The ESR detection scheme is based on the determination of the electrolytic capacitor AC losses calculated from voltage/current measurement using AC coupling. Therefore, the preposed online failure prediction method has the merits of easy ESR computation and circuit simplicity compare with BPF method. Simulation results show the veridity of the proposed on-line ESR estimation method.

Optimum Design of I-Type Girders in Steel Bridges by LRFD and ASD (하중-저항계수 설계법과 허용응력 설계법에 의한 강교량 주부재의 최적화 설계)

  • 안성욱;신영석
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.10a
    • /
    • pp.183-190
    • /
    • 1998
  • In this study, I-type girders, main members of a steel composite bridge, are designed by Load and Resistance Factor Design method as well as Allowable Stress Design method. The width, height web thickness and flange thickness of main girders are set as design variables. The design program connects optimization program ADS, which is coded with FORTRAN, and a main program coded with $C^{++}$. In this study, it is shown that in this particular steel composite bridge, the design by The Load and Resistance Factor Design method is more economical than that by The Allowable Stress Design method.d.

  • PDF

Optimum design of steel bridges including corrosion effect using TLBO

  • Artar, Musa;Catar, Recep;Daloglu, Ayse T.
    • Structural Engineering and Mechanics
    • /
    • v.63 no.5
    • /
    • pp.607-615
    • /
    • 2017
  • This study presents optimum design of plane steel bridges considering corrosion effect by using teaching-learning based optimization (TLBO) method. Optimum solutions of three different bridge problems are linearly carried out including and excluding corrosion effect. The member cross sections are selected from a pre-specified list of 128 W profiles taken from American Institute of Steel Construction (AISC). A computer program is coded in MATLAB to carry out optimum design interacting with SAP2000 using OAPI (Open Application Programming Interface). The stress constraints are incorporated as indicated in AISC Allowable Stress Design (ASD) specifications and also displacement constraints are applied in optimum design. The results obtained from analysis show that the corrosion effect on steel profile surfaces causes a crucial increase on the minimum steel weight of bridges. Moreover, the results show that the method proposed is applicable and robust to reach the destination even for complex problems.

Surgical Correction of Ebstein's Anomaly -11 cases- (Ebstein 기형의 외과적 치료 - 11례 -)

  • 이선희;김시훈;윤정섭;김치경;조건현;왕영필;곽문섭;김우찬
    • Journal of Chest Surgery
    • /
    • v.29 no.11
    • /
    • pp.1202-1206
    • /
    • 1996
  • Ebstein's anomaly is an unusual and a rare congenital cardiac malformation but characteristic abnormality of the development of the tricuspid valve, right atrium and ventricle. The characteristic findings are a displaced tricuspid valve with a septal leaflet spiralling into the right ventricle. The surgical correction is variable and are left unsolved problem in surgical treatment of anomaly. Between January 1988 & December 1995, we experienced 11 cases of Ebstein's anomaly and associated cardiac anomalies are ASD, PFO, ASD with VSD. The typically displaced tricuspid valve leaflet was found in all cases. In the NYHA functional classification, three were in class II, seven were in class III, and one was in class IV. Nine patients were operated by tricuspid annuloplasty & plication with Danielson's method and two patients were done by tricuspid valve replacement with plication, and in all cases associated anomaly was corrected. Postoperatively, five patients suffered from complication - low cardiac output syndrome, arrhythmia and wound infection. There was no operative mortality and the postoperative courses were relatively good conditions with more improvement of symptoms.

  • PDF

The development of EASI-based multi-path analysis code for nuclear security system with variability extension

  • Andiwijayakusuma, Dinan;Setiadipura, Topan;Purqon, Acep;Su'ud, Zaki
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3604-3613
    • /
    • 2022
  • The Physical Protection System (PPS) plays an important role and must effectively deal with various adversary attacks in nuclear security. In specific single adversary path scenarios, we can calculate the PPS effectiveness by EASI (Estimated Adversary Sequence Interruption) through Probability of Interruption (PI) calculation. EASI uses a single value of the probability of detection (PD) and the probability of alarm communications (PC) in the PPS. In this study, we develop a multi-path analysis code based on EASI to evaluate the effectiveness of PPS. Our quantification method for PI considers the variability and uncertainty of PD and PC value by Monte Carlo simulation. We converted the 2-D scheme of the nuclear facility into an Adversary Sequence Diagram (ASD). We used ASD to find the adversary path with the lowest probability of interruption as the most vulnerable paths (MVP). We examined a hypothetical facility (Hypothetical National Nuclear Research Facility - HNNRF) to confirm our code compared with EASI. The results show that implementing the variability extension can estimate the PI value and its associated uncertainty. The multi-path analysis code allows the analyst to make it easier to assess PPS with more extensive facilities with more complex adversary paths. However, the variability of the PD value in each protection element allows a significant decrease in the PI value. The possibility of this decrease needs to be an important concern for PPS designers to determine the PD value correctly or set a higher standard for PPS performance that remains reliable.

Autism Spectrum Disorder Detection in Children using the Efficacy of Machine Learning Approaches

  • Tariq Rafiq;Zafar Iqbal;Tahreem Saeed;Yawar Abbas Abid;Muneeb Tariq;Urooj Majeed;Akasha
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.4
    • /
    • pp.179-186
    • /
    • 2023
  • For the future prosperity of any society, the sound growth of children is essential. Autism Spectrum Disorder (ASD) is a neurobehavioral disorder which has an impact on social interaction of autistic child and has an undesirable effect on his learning, speaking, and responding skills. These children have over or under sensitivity issues of touching, smelling, and hearing. Its symptoms usually appear in the child of 4- to 11-year-old but parents did not pay attention to it and could not detect it at early stages. The process to diagnose in recent time is clinical sessions that are very time consuming and expensive. To complement the conventional method, machine learning techniques are being used. In this way, it improves the required time and precision for diagnosis. We have applied TFLite model on image based dataset to predict the autism based on facial features of child. Afterwards, various machine learning techniques were trained that includes Logistic Regression, KNN, Gaussian Naïve Bayes, Random Forest and Multi-Layer Perceptron using Autism Spectrum Quotient (AQ) dataset to improve the accuracy of the ASD detection. On image based dataset, TFLite model shows 80% accuracy and based on AQ dataset, we have achieved 100% accuracy from Logistic Regression and MLP models.