• Title/Summary/Keyword: ARRHYTHMIA

Search Result 608, Processing Time 0.042 seconds

Long-Term Outcomes of Modified Cone Reconstruction for Ebstein's Anomaly in Pediatric Patients in a Single Center

  • Ilkun Park;Tae-Gook Jun;Ji-Hyuk Yang;I-Seok Kang;June Huh;Jinyoung Song;Ok Jeong Lee
    • Korean Circulation Journal
    • /
    • v.54 no.2
    • /
    • pp.78-90
    • /
    • 2024
  • Background and Objective: We aimed to investigate long-term clinical and echocardiographic outcomes, including tricuspid valve durability, annular growth, and left ventricular reverse remodeling, after modified cone reconstruction in patients with Ebstein's anomaly. Methods: This was a retrospective analysis of all pediatric patients who underwent modified cone reconstruction for Ebstein's anomaly at a single tertiary center between January 2005 and June 2021. Results: A total of 14 pediatric patients underwent modified cone reconstruction for Ebstein's anomaly; the median age was 5.8 years (range, 0.01-16.6). There were three patients (21.4%) with Carpentier type B, ten patients with Carpentier type C (71.4%), and one patient with Carpentier type D (7.1%). There was no early or late mortality, arrhythmia, or readmission for heart failure at a 10-year follow-up. There were no cases of more than mild tricuspid stenosis or more than moderate tricuspid regurgitation during the study period, except for one patient with severe tricuspid regurgitation who underwent reoperation. The z value for tricuspid valve annular size significantly decreased immediately after the operation (2.46 vs. -1.15, p<0.001). However, from 1 year to 7 years after surgery, the z values were maintained between -1 and +1. Left ventricular end-systolic volume, end-diastolic volume, and stroke volume increased after surgery and remained elevated until seven years postoperatively. Conclusions: Ebstein's anomaly in children can be repaired by modified cone reconstruction with low mortality and morbidity, good tricuspid valve durability, and annular growth relative to somatic growth.

The Results of Extracardiac Fontan Operation in the Patients with Heterotaxy Syndrome (이소성증후군에서의 심장외도관 폰탄 수술의 결과)

  • Lim Hong Gook;Kim Soo-Jin;Lee Chang-Ha;Kim Woong-Han;Hwang Seong Wook;Lee Cheul;Oh Sam-Sae;Baek Man-Jong;Na Chan-Young;Kim Jae Hyun;Seo Hong Joo;Jung Sung Chol;Kim Chong Whan
    • Journal of Chest Surgery
    • /
    • v.38 no.8 s.253
    • /
    • pp.529-537
    • /
    • 2005
  • Background: Historically the Fontan operation in patients with single ventricle and heterotaxy syndrome has been associated with high mortality because of systemic or pulmonary anomalous venous drainage, incompetent common atrioventricular valve, right ventricle type univentricular heart, and arrhythmia. Material and Method: A retrospective review of 62 patients $(age:\;54.79\pm33.97\;months)$ with heterotaxy syndrome who underwent a extracadiac Fontan operation between 1996 and 2005 was performed. Twenty one patients had left atrial isomerism, and 41 had right isomerism. The Fontan procedure was staged in all but 2 patients, and a fenestration was less placed in left isomerism. Result: Left isomerism was associated more with interrupted inferior vena cava and pulmonary arteriovenous fistula, and right isomerism was associated more with anomalous pulmonary venous drainage, common atrioventricular valve and morphologic right ventricle. There were 3 hospital deaths$(4.8\%)$ and 3 late deaths $(5.2\%)$ with a follow-up duration of $48.8\pm31.0$ months. Eight-year survivals were $90.5\pm6.4\%$ in left isomerism and $88.6\pm5.4\%$ in right isomerism (p=0.94). At 8 years, freedom from reoperation was $73.9\pm11.3\%$ in left isomerism, and $82.3\pm6.7\%$ in right isomerism (p=0.87). Atrioventricular valve regurgitation progressed after Fontan operation in heterotaxy syndrome, and reoperation for pulmonary arteriovenous fistula and permanent pacemaker implantation for sinus node dysfunction were required more in left isomerism. Conclusion: The extracardiac Fontan operation can now be performed in patients with heterotaxy syndrome with excellent survival. However, morbidity in terms of postoperative atrioventricular valve regurgitation, arrhythmia, and pulmonary arteriovenous fistula remains significant.

Establishment of the Heart Failure Model in Swine for the Experiment of the Pneumatic Ventricular Assist Device (공압식 심실보조기의 실험을 위한 돼지에서의 심부전 모델의 개발)

  • 박성식;서필원;이상훈;강봉진;문상호;김삼현
    • Journal of Chest Surgery
    • /
    • v.36 no.3
    • /
    • pp.123-130
    • /
    • 2003
  • Background: In order to develop the acute heart failure model for the animal experiment of the pneumatic ventricular assist device, we decided to use young pig whose coronary artery distribution is almost the same as humans and also very cheap in price. The purpose of this study is to develop stable, reproducible acute ischemic heart failure model in swine using coronary artery ligation method. Material and Method: Five young pigs whose weights are the same as adult humans are under experiment. Each pig was under endotracheal intubation and connected to a mechanical ventilator. Through left lateral thoracotomy, we exposed the heart and induced ischemic heart failure by coronary artery ligation. The ligation began at the distal part of the left anterior descending coronary artery. After 5 minutes of initial ligation we reperfused the artery and then re-ligated. Before and after each ligation-reperfusion procedure we assessed the left ventricular end-diastolic pressure, arterial pressure, and cardiac index. We also measured left ventricular end-diastolic dimension, end-systolic dimension, fractional shortening, ejection fraction using intraoperative epicardial echocardiography. After appropriate heart failure was established with sequential (from distal part of LAD to proximal location) ligation-reperfusion-ligation procedure, we inserted the ventricular assist device and operated. Result: We established stable acute ischemic heart failure in 3 of 5 young pigs with this sequential ligation-reperfusion-ligation procedure, and could maintained 50% less ejection fraction before the procedure according to intraoperative epicardial echocardiography. We also observed no ventricular arrhythmia usually associated with simple coronary artery ligation in large animals and no cardiac arrest associated with ventricular arrhythmia or myocardial stunning. In pathologic specimen, we observed scattered ischemic myocardium in all around the ischemic field induced by coronary artery ligation. Conclusion: Under the concept of ischemic preconditioning, we developed safe and reproducible acute ischemic heart failure model in swine using sequential coronary artery ligation-reperfusion-ligation method.

Surgical Outcome of Tetralogy of Fallot in Adolt -Implication of Preoperative Cyanosis- (수술 전 청색증 정도에 따른 성인 활로씨 4징증의 임상 양상)

  • Kim Sang-hwa;Park Soon-Ik;Park Jung-Jun;Song Hyun;Lee Jae-Won;Seo Dong-Man;Song Meong-Gun;Song Jong-Min;Kang Duck-Hyun;Song Jae-Kwan;Jang Wan-Sook;Kim Young-Hwue;Yun Tae-Jin
    • Journal of Chest Surgery
    • /
    • v.38 no.4 s.249
    • /
    • pp.271-276
    • /
    • 2005
  • We analysed differences in operative methods and postoperative outcome according to the severity of preoperative cyanosis in adult ToF (Tetralogy of Fallot) patients. Material and Method: From August 1989 to June 2001, thirty three adult patients, 18 females and 15 males, underwent total correction for ToF. Their age ranged from 15 years to 54 years (median: 34). Patients were divided into 2 groups by preoperative $SaO_2$ (arterial oxygen saturation): group I$(n=cyanotic,\;SaO_2\;\geq94\%)$ and group II $(acyanotic,\; SaO_2\geq95%)$. Preoperative median hemoglobin level was higher in group I compared to group II (17.5 g/dl vs 15 g/dl). Postoperative follow-up duration ranged from 1 to 94 months (670 patient-month, median: 14 months), and 63 two-dimensional echocardiographic examinations were done during this period. Result: There were no early or late mortality. With regard to RVOT (right ventricular outflow tract) reconstruction, trans-annular patch and RV-PA extracardiac conduit were used in 7 and 3 patients respectively, and all of them belonged to group I. In group I, cardiopulmonary bypass time, aortic cross-clamping time, ICU day, hospital day were significantly longer than in group II, and postoperative inotropic support was significantly greater than in group II. There was no ventricular arrhythmia in both groups, and one patient in group I suffered from atrial arrhythmia, which was resolved spontaneously after tricuspid and pulmonary valve replacement. During follow-up periods, functional class, residual RVOT stenosis and pulmonary regurgitation, tricuspid regurgitation, occurrence of ventricular and atrial arrhythmias were comparable between two groups. Conclusion: In adult ToF patients with severe preoperative cyanosis, more aggressive RVOT reconstruction and careful postoperative care are mandatory. However intermediate-term outcome of this group of patients is comparable to the patients with minimal or no preoperative cyanosis.

Change of the Left Atrial Dimension and Transport Function after the Cox-Maze Procedure for Treating Atrial Fibrillation Associated with Mitral Valve Disease: the Short-term and Mid-Term Results (승모판막 질환과 동반된 심방세동에 대한 Cox-Maze 술식 후 좌심방 크기 및 기계적 수축력 변화: 중.단기 경과 관찰 분석)

  • Kim, Hwan-Wook;Lee, Jae-Won;Cho, Won-Chul;Jung, Sung-Ho;Choo, Suk-Jung;Song, Hyun;Chung, Cheol-Hyun
    • Journal of Chest Surgery
    • /
    • v.42 no.3
    • /
    • pp.317-323
    • /
    • 2009
  • Background: Although high efficiency of conversion into sinus rhythm has been demonstrated after performing the Cox-Maze procedure in patients with atrial fibrillation associated with mitral valve disease, the changes in the mechanical function and size of the left atrium have not been determined. The aim of the study was to evaluate the effect of the Maze procedure on the left atrial size and contractile transport function. Material and Method: From July 1997 to July 2008, 647 consecutive patients were operated on for chronic atrial fibrillation associated with mitral valve disease. Among these, 211 patients that (1) were able to be followed up for 2 years after surgery, (2) had sustained normal sinus rhythm, regardless of whether they were taking anti-arrhythmic medications and (3) did not have valvular regurgitation greater than grade III or they did not have moderate grade valvular stenosis were selected for evaluation. The left atrial size and contractile transport function were assessed by transthoracic echocardiography at the postoperative base line (1 year) and at regular follow-up periods (2 years, 3 years, 4 years and 6 year). Result: The left atrial dimension was increased and the contractile transport function was decreased during the follow-up period. The longer the follow-up period, the greater was the statistical significance of the left atrial size increase and contractile transport function decrease. Conclusion: In patients who sustain normal sinus rhythm conversion after a Maze III procedure with a mitral valve operation, there is a gradual increase of the left atrial dimensions and a decrease of contractile transport function during the follow-up period. Therefore, scrupulous follow-up is needed for these patients.

The Long-term Results of a Modified Maze Procedure with Using Cryoablation (냉동 절제를 이용한 변형된 Maze술 식의 중장기 결과)

  • Park, Kwon-Jae;Woo, Jong-Soo;Bang, Jung-Hee
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.710-717
    • /
    • 2008
  • Background: Atrial fibrillation is associated with several complications such as cerebro-vascular accidents and peripheral arterial embolism. Most of the patients who have this arrhythmia chronically feel their heart beating and so they are frightened; therefore, the quality of a patient's life is decreased. The purpose of this article is to determine the long term results of a modified Maze procedure and the factors that influence the success of the procedure. Material and Method: This study enrolled 88 patients who underwent the modified Maze with using cryoablation between June, 2001 and February, 2007. The 88 consecutive patients were divided into two groups ac cording to how the pulmonary veins were isolated, that is, with or without cryoablation. There were 58 patients who were isolated by cutting and sewing in the right pulmonary veins and by cyroablation in the left pulmonary veins in group 1 (group 1, n=58), and 30 patients who underwent isolation by cryoablation in the right & left pulmonary veins were placed in group 2 (group 2, n=30). The ECG was checked at discharge to determine the sinus conversion rate and we followed up the patients to determine whether or not the patients maintained sinus rhythm. We also checked the ECG at the last visit to determine the patients' heart rhythm. Result: The mean follow up time was $44.3{\pm}19.2$ months. At discharge, 72.4% of the patients in group 1 were in proper sinus rhythm and 66.7% of the patients in group 2 were in proper sinus rhythm. At the last follow up, 81% of the patients in group 1 were in normal sinus rhythm and 60% of the patients in group 2 were in normal sinus rhythm. When we analyzed the data via the Kaplan-Meier method, 86.5% of the patients were free from atrial fibrillation (% free from AF) at 1 year, 80% of the patients were free from atrial fibrillation at 5 year in group 1 and 70% of the patients were free from atrial fibrillation at 1 year and 51 % of the patients in group 2 were free from atrial fibrillation at 5 year. Conclusion: The modified Maze technique using cryoablation was a simple and effective procedure. But the success rate of the Maze technique using cryoblation is lower than that of the standard Maze III. The method using cryoablation shorten the operation time, but we must conduct more studies to get a better result of the modified Maze technique with using cryoablation.

Statistical Analysis of Patients Referred to Pediatric Cardiology Clinic for Diagnosis of Heart Disease (심장질환의 진단을 위해 의뢰된 환아들에 대한 자료 분석)

  • Choi, Kwang-Hae;Lee, Young-Hwan
    • Journal of Yeungnam Medical Science
    • /
    • v.17 no.1
    • /
    • pp.49-54
    • /
    • 2000
  • Background: Echocardiography is rapidly establishing itself as the primary diagnostic technique for investigation of children with heart diseases, and referrals are increasing to the pediatric cardiology clinic for investigation. However, because there is a lack of analyzed data on the patients referred to the pediatric cardiology clinics, we have proceeded to compare and analyze their characteristics to provide basic data base. Methods: From Oct. 1, 1998 to Jul. 10, 1999, total 443 cases referred to the pediatric cardiology clinic of Yeungnam University Hospital were studied retrospectively by medical records, chest X-ray, EKG and echocardiography, etc. Results: The results were as follows. 1. The proportion of male was 61.0%(261 cases) and that of female was 39.0%(67 cases). The ratio of male to female was 1.6:1. The proportion infants less than 1 year-old was 62.6% (26R cases) of all patients. 2. Cardiac murmur was present in 248 cases(57.9%), which was the most common case of referral ed to the pediatric cardiology clinic. The impression at referral was more congenital heart disease(70.6%) than acquired heart disease(17.8%) and arrhythmia01.6%). 3. The final diagnosis was as follows : congenital heart disease was present in 212 cases(49.5%), acquired heart disease, 59 cases(13.9%); arrhythmia. 13 cases(3.0%); normal heart. 144 cases(33.6%). Conclusion: Among the patients referred to pediatric cardiology clinic, 33.6%(144 cases) had normal hearts and why these patients were referred may be possibly due to more dependence on echocardiography than on auscultation instruction. Therefore, clinical and auscultatory skill should be emphasized to minimize dependence on expensive echocardiography for evaluation of pediatric heart disease.

  • PDF

Plasma Levels of Brain Natriuretic Peptide Predict Postoperative Atrial Fibrillation in Patients Undergoing Heart Surgery (심장 수술 후 심방세동 발생의 예측 인자로서 혈중 BNP 농도)

  • Kwon, Jin-Tae;Jung, Tae-Eun;Lee, Jang-Hoon;Lee, Dong-Hyup
    • Journal of Chest Surgery
    • /
    • v.40 no.6 s.275
    • /
    • pp.407-413
    • /
    • 2007
  • Background: The brain natriuretic peptide (BNP) level has been reported in some studies to be associated with the occurrence of atrial fbrillation (AF). The aim of this study is to evaluate the potential usefulness of the BNP level as a predictor of the occurrence of postoperative (postop) AF and to assess the relationship of the BNP level with the onset of AF and the restoration of sinus rhythm. Material and Method: From January 1, 2005 to February 28, 2006, 82 patients without a history of atrial arrhythmia that had undergone cardiac surgery were enrolled in the study. Blood samples for plasma BNP were drawn daily for all these patients from the preoperative (preop) day to the 7th postop day. The patient records were reviewed and postop EKGs were checked daily for AF until the time of discharge. Result: Patients were divided into two groups based on development of postop AF. Postoperative AF developed in 26 patients (31.7%). There was no significant statistical difference in age, sex distribution, preop left ventricle ejection fraction, hypertension, left ventricular hypertrophy, or the use of beta blockers between the non-postop AF and postop AF group. More patients in the AF group had undergone valve surgery (39.3% versus 76.9%, p=0.002). The preop left atrium size was significantly larger in the AF patients ($43.8{\pm}10.3 mm$ versus $49.8{\pm}11.5 mm$, p=0.029). The preop plasma BNP levels were higher in the postop AF patients ($144.1{\pm}20.8 pg/mL$ versus $267.5{\pm}68 pg/mL$, p=0.034). In the postop AF group, the plasma BNP level was the highest on the 3rd postop day. Postop AF developed in most patients by the 3rd postop day; restored sinus rhythm developed by the 7th postop day. Conclusion: Elevated plasma BNP levels may lead to the occurrence of postop AF in patients undergoing cardiac surgery. Patients who have a high risk of postop AF should be considered for aggressive prophylactic antiarrhythmic therapy.

Evaluation of Cardiac Ejection Fraction using Cardiac MRI (Cardiac MRI를 이용한 심박출계수의 평가)

  • Eun, Sung-Jong;Kook, Jin-Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.289-294
    • /
    • 2011
  • The aim of this study is to evaluate the differences of ejection fraction of left ventricle through the quantitative analysis of diastolic and systolic volumes according to slices selected using cardiac MR imaging. A total of 12 volunteers (7 normal, 1 myocardium bridge, and 4 arrhythmia) underwent cardiac MRI on a MR scanner(Magnetom Trio, Siemens, Germany). Ejection fractions for quantitative analysis were calculated at single slice of center of left ventricle, 3, 5, and 6-7 slices extending from the center of left ventricle. Average values were analyzed for evaluating differences of ejection fraction according to the number of slices selected. Mean value of normal person of ejection fraction were 67.14% at single slice of center of left ventricle, 66.24% at 3 slices, 65.63% at 5 slices, and 65.29% at 6-7 slices. While ejection fraction obtained from a patient with 61.74% at single slice of center of left ventricle, 60.92% at 3 slices, 60.89% at 5 slices, and 61.89% at 6-7 slices. There was no significant differences by the number of slices selected. This study demonstrates that ejection fraction obtained from single slice of center of left ventricle may represent a optimum parameter for cardiac function, instead of the value calculated on the variable slices selected.

Research on the modified algorithm for improving accuracy of Random Forest classifier which identifies automatically arrhythmia (부정맥 증상을 자동으로 판별하는 Random Forest 분류기의 정확도 향상을 위한 수정 알고리즘에 대한 연구)

  • Lee, Hyun-Ju;Shin, Dong-Kyoo;Park, Hee-Won;Kim, Soo-Han;Shin, Dong-Il
    • The KIPS Transactions:PartB
    • /
    • v.18B no.6
    • /
    • pp.341-348
    • /
    • 2011
  • ECG(Electrocardiogram), a field of Bio-signal, is generally experimented with classification algorithms most of which are SVM(Support Vector Machine), MLP(Multilayer Perceptron). But this study modified the Random Forest Algorithm along the basis of signal characteristics and comparatively analyzed the accuracies of modified algorithm with those of SVM and MLP to prove the ability of modified algorithm. The R-R interval extracted from ECG is used in this study and the results of established researches which experimented co-equal data are also comparatively analyzed. As a result, modified RF Classifier showed better consequences than SVM classifier, MLP classifier and other researches' results in accuracy category. The Band-pass filter is used to extract R-R interval in pre-processing stage. However, the Wavelet transform, median filter, and finite impulse response filter in addition to Band-pass filter are often used in experiment of ECG. After this study, selection of the filters efficiently deleting the baseline wandering in pre-processing stage and study of the methods correctly extracting the R-R interval are needed.