• Title/Summary/Keyword: ARI score

Search Result 17, Processing Time 0.022 seconds

Effects of direct and indirect bonding techniques on bond strength and microleakage after thermocycling (직접 부착법과 간접 부착법이 열순환 후 부착강도와 미세누출에 미치는 영향에 대한 연구)

  • Ozturk, Firat;Babacan, Hasan;Nalcaci, Ruhi;Kustarci, Alper
    • The korean journal of orthodontics
    • /
    • v.39 no.6
    • /
    • pp.393-401
    • /
    • 2009
  • Objective: The purpose of this study was to compare the shear bond strength (SBS) of brackets and microleakage of a tooth-adhesive-bracket complex bonded with a direct and an indirect bonding technique after thermocycling. Methods: Fifty non-carious human premolars were divided into two equal groups. In the direct bonding group a light-cured adhesive and a primer (Transbond XT) was used. In the indirect-bonding group, a light-cured adhesive (Transbond XT) and chemical-cured primer (Sondhi Rapid Set) were used. After polymerization, the teeth were kept in distilled water for 24 hours and thereafter subjected to thermal cycling (500 cycles). For the microleakage evaluation, 10 teeth from each group were further sealed with nail varnish, stained with 0.5% basic fuchsin for 24 hours, and examined under a stereomicroscope. Fifteen teeth from each group were used for SBS testing with the universal testing machine and adhesive remnant index (ARI) evaluation. Data were analyzed using the Mann-Whitney U test, Chi-square test, and Fisher's exact test. Results: There were no statistical differences on SBS and microleakage between the two bonding techniques. The indirect bonding group had a significantly lower ARI score. Bracket failures were obtained between enamel-resin interfaces. Conclusions: The type of bonding technique did not significantly affect the amount of microleakage and SBS.

Preliminary Validation Study of the Korean Version of the DSM-5 Level 2 Cross-Cutting Symptom Measure: Depression and Irritability for Parents of Children Aged 6-17 Years

  • Shin, Min-Sup;Kim, Bung-Nyun;Jang, Mirae;Shin, Hanbyul;Seo, Gyujin
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.33 no.3
    • /
    • pp.67-72
    • /
    • 2022
  • Objectives: This study investigated the reliability and validity of the Korean version of the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) Level 2 Cross-Cutting Symptom Measure-Patient-Reported Outcomes Measurement Information System (PROMIS)-Depression and the Irritability for parents of children aged 6-17 years. Methods: Participants were 190 children diagnosed with depressive disorder (n=14), anxiety disorder (n=21), attention-deficit/hyperactivity disorder (ADHD; n=111), ADHD with anxious depression (n=13), and tic disorder with somatic symptoms (n=31). Patients were 8-15 years of age. The participants' mothers completed the Korean versions of the DSM-5 Level 2 Cross-Cutting Symptom Measure-PROMIS Depression and Irritability (Affective Reactivity Index, ARI), and the Korean Child Behavior Checklist (K-CBCL). Using these data, we calculated the reliability coefficient and examined the concurrent and discriminant validity of the PROMIS Depression and the Irritability (ARI) scales for assessing depression and irritability in children. Results: The reliability coefficient of the PROMIS Depression scale (Cronbach's α) was 0.93. The correlation coefficient with the K-CBCL DSM emotional problem score was 0.71. The PROMIS Depression scale significantly discriminated children with depressive disorders from those with other conditions. The reliability coefficient of the Irritability (ARI) scale was 0.91, suggesting its high reliability. Conclusion: Our results suggest that the Korean version of the DSM-5 Level 2 Cross-Cutting Symptom Measure for Depression and Irritability Scales for parents of children aged 6-17 years is reliable and valid and may be an efficient alternative to the K-CBCL.

The Gastroesophageal Reflux Disease Questionnaire in Adolescents: What Is the Best Cutoff Score?

  • Artanti, Dian;Hegar, Badriul;Kaswandani, Nastiti;Soedjatmiko, Soedjatmiko;Prayitno, Ari;Devaera, Yoga;Vandenplas, Yvan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.22 no.4
    • /
    • pp.341-349
    • /
    • 2019
  • Background: A self-assessment questionnaire, the GERD-Questionnaire (GERD-Q) was used to determine the prevalence of GERD in adolescents, describe the related factors, and determine the impact on quality of life (QoL). Methods: The incidence of GERD was evaluated using the GERD-Q in adolescents aged 12-18 years. The Pediatric Gastroesophageal Reflux Disease Symptom Questionnaire and Quality of Life Questionnaire (PGSQ-A) for adolescents were additionally administered. Some factors considered related to GERD were also evaluated. Results: The 520 adolescents were included. The prevalence of suspected GERD, according to a GERD-Q cutoff score of ${\geq}7$ was 32.9%, and those drinking soda were 1.7 times more likely to have GERD (95% confidence interval, 1.3-2.2; p<0.001). However, soda consumption was not a risk factor for development of GERD symptoms. Applying a cutoff score of ${\geq}8$, only 10.9% of the participants had a positive GERD score, but the association with soda consumption persisted. The median PGSQ-A score in subjects suspected of GERD was 8 (range 0-37) on weekends and 1 (range 0-17) during weekdays (p<0.001) compared to those not suspected of GERD, with a median of 2 (range 0-27) during weekends and 0 (range 0-10) during weekdays. Heartburn, regurgitation, and extraesophageal symptoms correlated significantly with QoL (p<0.001). Conclusion: The prevalence of suspected GERD in adolescents was 32.9% or 10.9%, depending on the cutoff score used. There was a statistically significant difference in PGSQ-A scores between the subjects suspected or not of GERD, indicating an impaired QoL.

Comparison of shear bond strength of orthodontic brackets using various zirconia primers

  • Lee, Ji-Yeon;Kim, Jin-Seok;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.45 no.4
    • /
    • pp.164-170
    • /
    • 2015
  • Objective: The aim of this study was to compare the shear bond strength (SBS) of orthodontic brackets bonded to zirconia surfaces using three different zirconia primers and one silane primer, and subjected to thermocycling. Methods: We designed 10 experimental groups following the surface treatment and thermocycling. The surface was treated with one of the following method: no-primer (NP), Porcelain Conditioner (PC), Z-PRIME Plus (ZP), Monobond Plus (MP) and Zirconia Liner Premium (ZL) (n=20). Then each group was subdivided to non-thermocycled and thermocycled groups (NPT, PC, ZPT, MPT, ZLT) (n=10). Orthodontic brackets were bonded to the specimens using $Transbond^{TM}$ XT Paste and light cured for 15 s at $1,100mW/cm^2$. The SBS was measured at a 1 mm/min crosshead speed. The failure mode was assessed by examination with a stereomicroscope and the amount of bonding resin remaining on the zirconia surface was scored using the modified adhesive remnant index (ARI). Results: The SBS of all experimental groups decreased after thermocycling. Before thermocycling, the SBS was ZL, $ZP{\geq}MP{\geq}PC>NP$ but after thermocycling, the SBS was $ZLT{\geq}MPT{\geq}ZPT>PCT=NPT$ (p > 0.05). For the ARI score, both of the groups lacking primer (NP and NPT) displayed adhesive failure modes, but the groups with zirconia primers (ZP, ZPT, MP, MPT, ZL, and ZLT) were associated with mixed failure modes. Conclusions: Surface treatment with a zirconia primer increases the SBS relative to no-primer or silane primer application between orthodontic brackets and zirconia prostheses.

Comparison of bond strengths of ceramic brackets bonded to zirconia surfaces using different zirconia primers and a universal adhesive

  • Lee, Ji-Yeon;Ahn, Jaechan;An, Sang In;Park, Jeong-won
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.1
    • /
    • pp.7.1-7.7
    • /
    • 2018
  • Objectives: The aim of this study is to compare the shear bond strengths of ceramic brackets bonded to zirconia surfaces using different zirconia primers and universal adhesive. Materials and Methods: Fifty zirconia blocks ($15{\times}15{\times}10mm$, Zpex, Tosoh Corporation) were polished with 1,000 grit sand paper and air-abraded with $50{\mu}m$ $Al_2O_3$ for 10 seconds (40 psi). They were divided into 5 groups: control (CO), Metal/Zirconia primer (MZ, Ivoclar Vivadent), Z-PRIME Plus (ZP, Bisco), Zirconia Liner (ZL, Sun Medical), and Scotchbond Universal adhesive (SU, 3M ESPE). Transbond XT Primer (used for CO, MZ, ZP, and ZL) and Transbond XT Paste was used for bracket bonding (Gemini clear ceramic brackets, 3M Unitek). After 24 hours at $37^{\circ}C$ storage, specimens underwent 2,000 thermocycles, and then, shear bond strengths were measured (1 mm/min). An adhesive remnant index (ARI) score was calculated. The data were analyzed using one-way analysis of variance and the Bonferroni test (p = 0.05). Results: Surface treatment with primers resulted in increased shear bond strength. The SU group showed the highest shear bond strength followed by the ZP, ZL, MZ, and CO groups, in that order. The median ARI scores were as follows: CO = 0, MZ = 0, ZP = 0, ZL = 0, and SU = 3 (p < 0.05). Conclusions: Within this experiment, zirconia primer can increase the shear bond strength of bracket bonding. The highest shear bond strength is observed in SU group, even when no primer is used.

Bond strength of different bonding systems to the lingual surface enamel of mandibular incisors (하악 전치 설측면에 대한 다양한 접착시스템의 접착강도)

  • Turkoz, Cagri;Tuncer, Burcu Balos;Ulusoy, Mehmet Cagri;Tuncer, Cumhur
    • The korean journal of orthodontics
    • /
    • v.40 no.4
    • /
    • pp.260-266
    • /
    • 2010
  • Objective: The aim of this study was to determine whether different types of adhesive systems and enamel-protective agents will affect the tensile bond strength of lingual brackets. Methods: A total of 75 extracted mandibular incisors were randomly divided into 5 groups and lingual brackets were bonded. Group 1 specimens received Transbond XT (3M Unitek, Monrovia, CA, USA), Group 2 required the application of a fluoride-releasing resin (Ortho-coat, Pulpdent, Watertown, MA, USA) with Transbond XT, Group 3 specimens received a chlorhexidine varnish (Cervitec Plus, Ivoclar Vivadent, Schaan, Lichtenstein) with Transbond XT. In Group 4, a light-cured orthodontic adhesive (Aegis Ortho, Bosworth, Skokie, USA) was applied and in Group 5, an antimicrobial self-etching primer (Clearfil Protect Bond, Kuraray, Osaka, Japan) was used. Results: There were no significant differences in bond strength whether fluoride-releasing resin or chlorhexidine varnish were used or not. Group 5 had significantly higher bond strength and adhesive remnant index (ARI) values than other groups (p < 0.001). The application of enamel-protective products did not have an adverse affect on the bond strength of lingual brackets. Conclusions: These products might provide benefits both for the patient and the clinician, by supporting the oral hygiene during lingual orthodontic treatment. The higher ARI score may be beneficial for Clearfil Protect Bond but its excessive bond strength should be considered in clinical practice, especially where the enamel is thin.

SHEAR BOND STRENGTH AND FAILURE PATTERNS ACCORDING TO THE MATERIAL OF RESIN BASE IN INDIRECT BRACKET BONDING (브라켓 간접부착시 레진 베이스의 재료에 따른 전단결합강도와 파절양상 비교)

  • Jeon, Man-Bae;Hwang, Hyeon-Shik;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.28 no.2 s.67
    • /
    • pp.277-284
    • /
    • 1998
  • The purpose of this study was to evaluate the propriety of making use of the light-cured resin base in indirect bracket bonding technique by study of shear bond strength and failure patterns according to the material of resin base. Metal brackets were bonded to the stone models of specimens involving bovine lower incisor with chemical-cured(Excel), light-cured(Light-Bond) and thermal-cured(Therma-Cure) resin. They were transferred to the specimens and bonded using sealant. The shear bond strength was tested on Instron. After bracket removal, the bracket base was examined and assessed with the adhesive remnant index(ARI). The results were as follows : 1. No significant differences in shear bond strength were found among the three groups (P>0.05). 2. No significant differences in ARI score were found among the three groups (P>0.05). The above results suggest that light-cured resin base in addition to chemical-cured and thermal-cured resin bases is useful in the indirect bonding technique.

  • PDF

Effect of metal primer and thermocycling on shear bonding strength between the orthodontic bracket and gold alloy (치과용 금합금에 대한 금속 프라이머 처리와 열순환 처리가 교정용 브라켓의 전단결합강도에 미치는 영향)

  • Lee, Young-Kee;Cha, Jung-Yul;Yu, Hyung-Seog;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.39 no.5
    • /
    • pp.320-329
    • /
    • 2009
  • Objective: The aim of this study was to evaluate the effect of metal primers and thermocycling on shear bond strength between the orthodontic bracket and gold alloy. Methods: For this study, 80 specimens made of dental gold alloy were divided into 8 groups based on the combination of metal primers (none, Alloy primer, Metaltite, V-primer) and thermocycling (with and without thermocycling). Shear bond strength testing was performed with a universal testing machine. Bond failure sites were classified by a modified ARI (Adhesive Remnant Index) score. Results: All metal primer treated groups showed a significantly higher shear bond strength than the only sandblasting treated group without thermocycling (p < 0.05). There were no significant differences on shear bond strength in the groups with thermocycling (p > 0.05). Bond failure sites of the metal primer treated group without thermocycling occurred at gold alloy/adhesive interface, whereas there were no differences on bonding failure sites in the groups with thermocycling. Conclusions: These findings suggest that using metal primer on gold alloy enhances the initial bracket bond strength. But, this effect was not shown with thermocycling.

Effects of light direction and exposure times of plasma arc light on shear bond strength of metal brackets (Plasma arc light를 이용한 금속 브라켓의 부착시 광조사 방향과 중합시간이 전단결합강도에 미치는 영향)

  • Roh, Sang-Jeong;Lee, Hyun-Jung;Jeon, Young-Mi;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.429-438
    • /
    • 2004
  • The purpose of this study was to compare the effects of different light direction exposure times and setting times when using plasma arc light on shear bond strength of metal brackets. 240 extracted human premolars were randomly assigned to one of 16 groups Standardized brackets were bonded to enamel using different light curing units (Plasma arc light and Halogen light), exposure times (Plasma arc light 2. 4, 6 seconds and Halogen light 20 seconds). and light directions [Vertical direction [V] and Oblique direction [O]). 8 groups were tested after 5 minutes and the remaining 8 groups after 24 hours. The metal brackets were bonded with Transbond XT. Shear bond strength was measured by a universal testing machine. The results were as fellows: There were as differences between the shear bond strengths of the Vertical groups (V) and Oblique groups (O). regardless of exposure times and types of light curing units (p>0.05). The shear bond strength of the group with 2 seconds of plasma light were significantly lower than other exposure time groups (P<0.05). The shear bond strength tested after 5 minutes was lower than after 24 hours (p<0.05) The Adhesive Remment Index (ARI) score showed no statistically significant difference among the different groups. The results of this study suggested that the light direction of plasma arc light had no influence on the shear bond strength of metal brackets to enamel. and exposure times more than 4 seconds produced shear bond strengths similar to those Produced with a conventional halogen curing light.

Shear bond strength of metal orthodontic brackets bonded with Self-Etching Primer (Self-etching primer를 이용하여 접착된 교정용 브라켓의 전단결합강도)

  • Ahn, Yun-Pyo;Kim, Hyo-Young;Jeon, Young-Mi;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.33 no.1 s.96
    • /
    • pp.51-61
    • /
    • 2003
  • The purpose of this study was to evaluate the effects of a self-etching primer on the shear bond strength of orthodontic brackets and on the failure pattern of bracket-adhesive interfaces in dry or wet condition. Brackets were bonded to extracted human teeth according to one of three experimental protocols. In the Group P, teeth were etched with $37\%$ phosphoric acid. After the Transbond XT Primer was applied onto the etched surfaces, the brackets were bonded with Transbond XT(3M, Unitek, Monrovia, Calif) and light cured for 40 seconds. In the Group SD, a self-etching primer(3M, Unitek, Monrovia, Calif) was placed on the enamel for 3 seconds and gently evaporated with air, as suggested by the manufacturer. The brackets were then bonded with Transbond XT as in the Group P In the Group SW, artificial saliva was applied to the enamel surface for 10 seconds to allow complete hydration of the surface before application self-etching primer The brackets were then bonded following the procedures of Group SD. Each group was divided into 2 sub-groups(0.5h, 24h) according to debonding time. Shear bond strengths were measured by Instron universal testing machine. After debonding, the teeth and brackets were examined under scanning electron microscope and assessed with the adhesive remnant index. The result obtained were summarized as follows ; 1. The shear bond strengths were high enough to use clinically in all testing groups, but the shear bond strengths of Group SD and SW were significantly lower than Group P(p<0.05). 2. With respect to comparison of debonding time, 24h debonding samples exhibited heigher shear bond strength than 0.5h debonding samples in Group P, SD and SW(p<0.05). 3. In the self etching primer groups(Group SD and Group SW), there was no significant difference in mean shear bond strength between under dry and wet state(p>0.05). 4. There was a greater frequency of ARI score of 0 and 1 with the Group P. On the other hand, there was a higher frequency of ARI scores of 2 and 3 with Group SD and Group SW(p<0.05).