• Title/Summary/Keyword: APEX

Search Result 1,136, Processing Time 0.029 seconds

A STUDY OF DETERMINATION OF PHYSIOLOGICAL ROOT APEX BY ELECTRICAL RESISTANCE VALUE (전기저항치에 의한 생리적 근첨(根尖)의 측정에 관한 연구)

  • Yun, Ki-Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.7 no.1
    • /
    • pp.25-31
    • /
    • 1981
  • One of the most important factors for successful endodontic therapy is an accurate length determination of physiological root apex. Some methods suggested for the measurement of root canal length, include digital-tactile sense and roentgenographic technique with measuring wire, scale and grid. But these methods do not derermine an accurate working length to physiological root apex. Recently electronic measuring devices are used to locate the physiological root apex in root canal length determination and these devices are accepted as an effective apparatus. The 89 patients (116 teeth, 144 canals) among the out-patients of Yonsei University Dental Infirmary, who had had an endodontic treatment in the Department of Operative Dentistry, were measured by the Root-Canal Meter$^{(R)}$ as an electronic device, and radiographs to determine the distribution and location of physiological root apex, then the following results were made: (1) Range of ${\pm}$1mm from the radiographic root apex were present in 88.88% (128 canals) of the subjects. (2) Physiological root apex and radiographic root apex were coincided in 31.94% (46 canals) of the subjects. (3) The actual length of the physiological root apex of the teeth were as follow; A : in the maxillary central incisor : 0.46mm B : in the maxillary lateral incisor : 0.44mm C : in the maxillary canine : 0.44mm D : in the maxillary 1st premolar : a) Buccal : 0.59mm b) Lingual : 0.34mm E : in the maxillary 2nd premolar : 0.54mm F : in the maxillary 1st molar : a) Mesio-buccal : 0.50mm b) Disto-buccal : 0.42mm c) Lingual : 0.56mm G : in the mandibular central incisor : 0.62mm H : in the mandibular lateral incisor : 0.45mm in the mandibular canine : 0.54mm J : in the mandibular 1st premolar : 0.47mm K : in the mandibular 2nd premolar : 0.34mm L : in the mandibular 1st molar : a) Mesio-buccal : 0.54mm b) Mesio-lingual : 0.31mm c) Distal : 0.37mm.

  • PDF

Another Glenoid Measurements for Shoulder Surgery

  • Jeong, Yeon-Seok;Yum, Jae-Kwang;Lee, Jun-Seok
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.4
    • /
    • pp.179-185
    • /
    • 2018
  • Background: We analyzed the angle between the glenoid anterior surface and glenoid axis, the range of the glenoid apex and the location of the glenoid apex for assistance during shoulder surgery. Methods: Sixty-two patients underwent a computed tomography of the shoulder with a proximal humerus fracture. In the range of the glenoid apex, the ratios of the distribution of triangles with a Constant anterior and posterior area of the glenoid were measured. The location of glenoid apex was confirmed as the percentage of the position with respect to the upper part of the glenoid with the center of the part, analyzed the angle between the glenoid anterior surface and glenoid axis was measured. Results: The angle between the glenoid anterior surface and glenoid axis was $19.80^{\circ}{\pm}3.88^{\circ}$. The location of the glenoid apex is $60.36%{\pm}9.31%$, with the upper end of the glenoid as the reference. The range of the glenoid apex was $21.16%{\pm}4.98%$. When the height of the glenoid becomes smaller, the range of the glenoid apex tends to become larger (p=0.001) and the range of the glenoid apex becomes wider (p=0.001) as the glenoid width narrows. Conclusions: We believe the anatomical measurements of the glenoid will be helpful for a more accurate insertion in glenoid component. It is thought that more accurate insertion is possible if we can set other anatomical measurements using computed tomography imaging of the glenoid which can develop into the study of other anatomical measurements.

Development of Web-based APEX Best Management Practices Evaluation Technique (Web 기반 APEX 최적관리기법 평가 기술 개발)

  • Yang, Dongseok;Bae, Joohyeon;Park, Woonji;Choi, Yujin;Lim, Kyoungjae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.315-315
    • /
    • 2020
  • 기후변화로 인하여 전 세계적으로 이상기후가 진행되고 있다. 우리나라의 경우 홍수와 가뭄 등의 이상 강수가 빈번히 발생하고 있으며, 이로 인한 비점오염물질의 유출과 집적이 발생하고 있다. SWAT (Soil and Water Assessment Tool)과 HSPF (Hydrological Simulation Program)등의 다양한 모델이 비점오염의 유출을 모의하기 위하여 활용되고 있으나, 농장 단위에서 유역 단위까지 다양한 대상지역에 대한 장기 모의와 BMP적용에 따른 효율평가가 어려운 실정이다. Texas A&M Agrilife Research에서 개발한 APEX(Agricultural Policy Environmental eXtender model) 모형의 경우, 농장 단위에서 유역 단위의 대상지역에 대하여 최대 100년까지 일단위 모의가 가능한 특징이 있다. 하지만 APEX 모형은 개발된지 상당한 시간이 지났으며, 데스크탑 기반의 모형이므로 다양한 플랫폼에서의 활용이 어려운 한계점이 있다. 따라서 본 연구에서는 1. 기존 데스크탑 기반의 APEX 모형을 웹에서 구동할 수 있도록 웹 기반 시스템을 구축하였으며, 2. 양분유출에 대한 모의 평가가 가능하도록 결과를 시스템화하는 모듈을 추가하였다. 또한, 3. 웹 기반 APEX 모형의 활용도를 위하여 최적관리기법을 적용할 수 있는 모듈을 개발 및 추가하였다. 본 연구의 결과는 향후 농업비점오염원 지역의 양분유출을 확인·예측하고 관리하기 위한 기초자료로 활용될 것으로 기대하며, 최적관리기법을 활용한 저감 정책을 수립하기 위한 평가도구로 활용될 수 있을 것이다. 또한, 기존 데스크탑 기반의 모형을 웹 기반으로 이전하였으므로, APEX 모형 혹은 다른 데스크탑 기반 모형들의 웹 이전을 통한 사용자 편의성 증대를 위한 기초자료로 활용될 수 있을 것이다. 아울러 본 연구의 결과는 APEX 모형의 작물 매개변수가 국내 환경에 최적화 되어있지 않으므로 정확한 BMP 저감효과 모의에는 한계가 있으므로, 이에 대한 추가적인 연구가 필요할 것으로 판단된다.

  • PDF

The Applicability of SWAT-APEX Model for Agricultural Nonpoint Source Pollution Assessment (농업 비점오염원 평가를 위한 SWAT-APEX 모델의 적용성 검토)

  • Jung, Chung-Gil;Park, Jong-Yoon;Lee, Ji-Wan;Jung, Hyuk;Kim, Seong-Joon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.5
    • /
    • pp.35-42
    • /
    • 2011
  • This study is to check the applicability of SWAT-APEX (Soil and Water Assessment Tool-Agricultural Policy / Environmental eXtender) model as combined watershed and field models by applying the APEX to paddies in a watershed (465.1 $km^2$) including Yedang reservoir. Firstly, the SWAT were calibrated with 3 years (2000~2002) daily streamflow and monthly water quality (T-N and T-P) data, and validated for another 3 years (2003~2005) data. The average Nash-Sutcliffe model efficiency (ME) of streamflow during validation was 0.73, and the coefficient of determination ($R^2$) of T-N and T-P were 0.77 and 0.73 respectively. Next, running the SWAT-APEX model with the SWAT calibrated parameters for paddies, the $R^2$ of T-N and T-P were 0.80 and 0.76 respectively. The results showed that SWAT-APEX model was more correctly predicted for T-N and T-P loads than SWAT model. The difference results between watershed and field models was predicted to have substantial impact on NPS loads, especially on T-N and T-P loads. Therefore, to improve negative NPS load simulations should be considered the model characteristics as simulating mechanism to properly select the NPS model for agricultural watershed.

A CASE REPORT OF DENTAL ROOT APEX CYST WHICH WAS MISDIAGNOSED MAXILLARY SINUSITIS (상악동염으로 오진된 Dental Root Apex Cyst 치험 일예)

  • Kim, Jae-Choel
    • The Journal of the Korean dental association
    • /
    • v.10 no.7
    • /
    • pp.413-415
    • /
    • 1972
  • The author had a case report of right maxillary molar tooth root apex cyst involving maxillary sinus, which was misdiagnosed maxillary sinusitis or some cancer. Right maxillary 2nd premolar, 1st molar, & 2nd molar tooth involved root apex cyst was extracted and curetted.

  • PDF

An evaluation of the accuracy of Root ZX according to the conditions of major apical foramen (주근단공의 조건에 따른 Root ZX의 정확성 평가)

  • Park, Shin-Young;Lee, Dong-Kyun;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.2
    • /
    • pp.68-73
    • /
    • 2012
  • Objectives: The purpose of this study was to assess the accuracy of Root ZX (J. Morita Corp.) according to the location of major foramen and open apex. Materials and Methods: 81 mandibular premolars with mature apices were selected. After access preparation, 27 teeth were instrumented to simulate open apices. 54 teeth were classified according to location of major foramen under surgical microscope (${\times}16$). The file was fixed at the location of apical constriction by Root ZX using glass ionomer cement .The apical 4 mm of the apex was exposed and photo was taken and the distance from file tip to the major foramen was measured by calibrating metal ruler on graph paper. The results were statistically analyzed using ANOVA and Scheffe test at p < 0.05 level. Results: Mean distance from file tip to major foramen was 0.308 mm in Tip foramen group (I), 0.519 mm in Lateral foramen group (II) and 0.932 mm in open apex group (III). Root ZX located apical constriction accurately within ${\pm}0.5mm$ in group I of 85.71%, in group II of 59.09%, and in group III of 33.33%. There was a statistically significant difference between group I and III (p < 0.05). Conclusion: Root ZX located apical constriction accurately regardless of location of major foramen. However, Root ZX couldn't find it in open apex. Clinicians have to use a combination of methods to determine an appropriate working length at open apex. It may be more successful than relying on just electronic apex locator.

The ralationship between apex seal breakage and engine detonation in a wankel engine (Wankel 엔진의 에이펙스 시일 파손과 엔진 이상폭발과의 관계)

  • 김승수
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.7 no.1
    • /
    • pp.48-54
    • /
    • 1985
  • One of the most probable reason of the apex seal damage in IR-2500 industrial Wankel (rotary) engine was believed to be the engine detonation. Both analytical and experimental studies were made with a view th find out engine detonation pressure. The stagnation detonation pressure $p_{03}$' was estimated based on the data from IR-2500 engine detonation tests, such as engine firing pressure, state of fresh charge at BDC and polytropic compression exponent. The estimated stagnation detonation pressure for the natural gas fueled IR-2500 engine was in excess of 3,700 psia. With natural gas liquid added to the natural gas the octane value of the fuel was lowered, thus, making the engine more prone to detonate. The estimated detonation pressure for the case with the mixed fuel was about 3,400 psia which was sufficiently high to break the apex seal. The subsequent engine lab tests performed on two identical engines with sole difference in the apex seal thickness between the two engines proved that the engine knock, in fact, was the villain of the apex seal failure.ilure.

  • PDF

New Technique for Surgery of Petrous Apex Cholesterol Granuloma

  • Kim, Eal-Maan;Nam, Sung-Il
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.5
    • /
    • pp.347-351
    • /
    • 2007
  • The authors present a new technique for surgery of cholesterol granuloma [CG] at the petrous apex. An epidural middle fossa approach is used to expose and remove the cyst, with silicon tube drainage into the sphenoid sinus via the anterolateral cavernous sinus triangle between the first and second divisions of the trigeminal nerve. This novel method is less invasive skull base approach to the petrous apex and very effective for minimizing recurrence of CGs within the petrous apex.

Measurement of Spinal Curvature by Using Enhanced Hough Transform on X-ray Imaging (X-ray 영상에서 개선된 허프 변환을 이용한 척추만곡도 측정)

  • Jeong, Hyang su;Kim, Kwang Beak
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.360-362
    • /
    • 2018
  • 본 논문에서는 X-ray 영상에서 척추 영역을 추출 및 분석하여 척추만곡도를 자동으로 측정하는 방법을 제안한다. 제안된 방법은 X-ray 영상에서 어깨뼈와 골반뼈 등과 같이 필요 없는 영역을 제거한 ROI(Region of Interest) 영역을 추출하고, 추출된 ROI 영역에서 척추 에지를 검출하기 위해 가우시안-라플라시안(Laplacian of Gaussian) 필터를 적용하여 척추 에지를 검출한다. 추출된 척추 영역을 척추의 Apex를 기준으로 Above Apex와 Below Apex 영역으로 구분하고 허프 변환(Hough Transform) 기법을 적용하여 두 영역에 대한 ($r,{\theta}$) 허프 공간을 구한다. ($r,{\theta}$) 허프 공간에서 척추만곡도 측정에 필요한 수평 직선만을 검출하기 위하여 수직 직선을 나타내는 교점들의 영역을 제거하여 척추만곡도 측정에 필요한 영역을 추출한다. 제안된 척추 추출 방법을 다양한 X-ray 영상을 대상으로 실험한 결과, 전문의가 척추만곡도를 효과적으로 측정하고 분석할 수 있는 척추 영역이 추출된 것을 확인할 수 있었다.

  • PDF