• 제목/요약/키워드: AP position

검색결과 188건 처리시간 0.027초

Effects of Chlorhexidine digluconate on Rotational Rate of n-(9-Anthroyloxy)stearic acid in Model Membranes of Total Lipids Extracted from Porphyromonas gingivalis Outer Membranes

  • Jang, Hye-Ock;Kim, Dong-Won;Kim, Byeong-Ill;Sim, Hong-Gu;Lee, Young-Ho;Lee, Jong-Hwa;Bae, Jung-Ha;Bae, Moon-Kyoung;Kwon, Tae-Hyuk;Yun, Il
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제8권2호
    • /
    • pp.83-88
    • /
    • 2004
  • The purpose of this study was to provide a basis for studying the molecular mechanism of pharmacological action of chlorhexidine digluconate. Large unilamellar vesicles (OPGTL) were prepared with total lipids extracted from cultured Porphyromonas gingivalis outer membranes (OPG). The anthroyloxy probes were located at a graded series of depths inside a membrane, depending on its substitution position (n) in the aliphatic chain. Fluorescence polarization of n-(9-anthroyloxy)stearic acid was used to examine effects of chlorhexidine digluconate on differential rotational mobility, while changing the probes' substitution position (n) in the membrane phospholipids aliphatic chain. Magnitude of the rotational mobility of the intact six membrane components differed depending on the substitution position in the descending order of 16-(9-anthroyloxy)palmitic acid (16-AP), 12, 9, 6, 3 and 2-(9-anthroyloxy)stearic acid (12-AS, 9-AS, 6-AS, 3-AS and 2-AS). Chlorhexidine digluconate increased in a dose-dependent manner the rate of rotational mobility of hydrocarbon interior of the OPGTL prepared with total lipids extracted from cultured OPG, but decreased the mobility of membrane interface of the OPGTL. Disordering or ordering effects of chlorhexidine digluconate on membrane lipids may be responsible for some, but not all of its bacteriostatic and bactericidal actions.

CT 영상 및 kV X선 영상을 이용한 자동 표지 맞춤 알고리듬 개발 (Development of an Automatic Seed Marker Registration Algorithm Using CT and kV X-ray Images)

  • 정광호;조병철;강세권;김경주;배훈식;서태석
    • Radiation Oncology Journal
    • /
    • 제25권1호
    • /
    • pp.54-61
    • /
    • 2007
  • 목 적: 본 연구의 목적은 전립선암 환자의 방사선 치료 시 표적의 정확한 위치를 찾기 위해 표지(marker)를 삽입한 경우 방사선치료계획 시 촬영한 CT 영상과 매 치료 시 온보드 영상장치(on-board imager, OBI)로부터 획득된 직교 kV X선 영상을 이용하여 표지의 위치를 계산하고 자동으로 맞춤을 수행하여 환자 셋업 오차를 보정하도록 하는 방법을 개발하는 것이다. 대상 및 방법: 세 개의 금 표지를 환자 전립선의 기준 위치에 삽입한 후 CT 모의치료기를 이용하여 2 mm 슬라이스 간격으로 CT 영상을 획득하였으며 매 치료 전에 환자 셋업 보정을 위하여 OBI를 이용하여 직교하는 kV X선 환자 영상을 획득하였다. CT 및 kV X선 영상 내 표지 정보 및 좌표 값 추출을 위하여 화소값의 문턱값 처리, 필터링, 외곽선 추출, 패턴 인식 등 다수의 영상처리 알고리듬을 적용하였다. 각 표지들 위치의 대표값으로 삼각형의 무게중심 개념을 이용하였으며 기준 CT 영상 및 직교 kV X선 영상으로부터 각각 무게중심의 좌표를 구한 후 그 차이를 보정해야 할 셋업의 오차로 계산하였다. 알고리듬의 건전성(robustness) 평가를 위해 팬텀을 이용하여 계산된 CT 및 kV X선 영상의 무게중심이 실제 지정된 위치와 일치하는지 여부를 확인하였으며, 본원에서 방사선 치료를 시행한 네 명의 전립선암 환자에 대상으로 치료 직전 촬영한 38 내지 39쌍의 kV X선 영상에 대하여 알고리듬을 적용한 후 OBI 프로그램에서 제공되는 2차원-2차원 맞춤 결과와 비교하였다. 결 과: 팬텀 실험 결과 실제 값과 CT 영상 및 직교 kV X선 영상으로부터 계산된 무게 중심 좌표 값이 1 mm 오차 내에서 일치함을 확인할 수 있었다. 환자 영상에 적용한 경우에도 모든 영상에 대하여 성공적으로 각 표지의 위치를 계산할 수 있었으며 2차원-2차원 맞춤 기능을 이용하여 계산된 셋업 오차와 비교해본 결과 1 mm 범위 내에서 일치함을 확인할 수 있었다. 본 알고리듬을 이용하여 계산한 결과 셋업 오차는 전후(AP) 방향으로 환자별로 작게는 $0.1{\pm}2.7\;mm$에서 크게는 $1.8{\pm}6.6\;mm$까지, 상하(SI) 방향으로 $0.8{\pm}1.6\;mm$에서 $2.0{\pm}2.7\;mm$, 좌우(Lat) 방향으로 $-0.9{\pm}1.5\;mm$에서 $2.8{\pm}3.0\;mm$까지였으며 환자에 따라 그 편차의 차이가 있었다. 결 론: 제안된 알고리듬을 이용하여 1회 셋업 오차를 평가하는 데 소요되는 시간은 10초 미만으로서 임상 적용 시 환자 셋업 시간을 줄이고 주관성을 배제하는 데 도움이 될 수 있을 것으로 기대된다. 그러나 온라인 환자 셋업 보정 시스템에 적용하기 위해서는 선형가속기의 제어 시스템에 통합되는 것이 필요하다.

외적요인에 따른 RSS 특성 분석과 이를 이용한 실시간 위치 추적 시스템 구현에 관한 연구 (A Study On RTLS(Real Time Location System) Based on RSS(Received Signal Strength) and RSS Characteristics Analysis with the External Factors)

  • 이승호
    • 전기전자학회논문지
    • /
    • 제15권1호
    • /
    • pp.76-85
    • /
    • 2011
  • 본 논문에서는 외적요인에 따른 RSS 특성을 분석하고, RSS를 이용한 효율적인 실시간 실외 위치 추적 알고리즘과 그에 기반 한 시스템을 제안하였다. 제안된 알고리즘은 지정된 공간 내에서의 위치별 신호 세기를 DB화하여 칼만 필터 이론을 적용한 예측을 통한 정확한 좌표를 선별하는 방법을 적용하여 위치 추적의 정확도를 높였다. 제안된 알고리듬의 검증을 위한 하드웨어 장치로는 802.15.4(ZigBee) 네트워크 환경에서 위치 정보를 전송하기 위해 태그(Tag), AP(Access Point), 데이터 수집기(Data Receiver) 등으로 구현하였다. 각각의 하드웨어는 Texas Instrument(TI)사의 MSP430 마이크로프로세서와 CC2420 무선통신 칩을 사용하여 구현되었다. 또한 태그 위치를 2차원 평면상에 나타내기 위한 실시간 위치 추적 프로그램을 구현하였다. 제안된 알고리즘에 기반 한 실시간 위치추적 시스템을 구축하여 태그의 위치를 추적한 결과 외적요인에 비교적 안정한 RSS 값을 갖는 실외 환경에서는 19.12cm의 평균 거리 오차와 5.31cm의 표준편차를 갖는 실시간 위치 추적 시스템의 효율성과 정확성이 나타남을 확인 할 수 있었다. 한편, 외적요인에 의해 불안정한 RSS 값을 갖는 실내 환경에서는 제안한 알고리즘과 그에 기반 한 시스템이 정확한 실시간 위치 추적에 다소 어려움이 있음을 확인 할 수 있었다.

정상 성인 족부 방사선 사진에서 족근 중족 관절 선열 형성 빈도 및 정상 변이 (Normal Variation and Incidence of Coincided Alignment on Lisfranc Joint on Normal Foot Radiography)

  • 강충남;김종오;고상훈
    • 대한족부족관절학회지
    • /
    • 제1권1호
    • /
    • pp.43-50
    • /
    • 1997
  • The tarsometatarsal joint complex is formed by articulation of the five metatarsal bases with the three cuneiform bones and the cuboid bone. Fracture-dislocation of tarsometatarsal area are difficult to recognize on standard radiographs. The exact diagnosis is occasionally delayed. As a result, improper treatment and late sequelae remains. We decided to make a study of patients with normal foot radiographs on 200 cases. Standard radiographic evaluation was used to study the normal variants of the foot and to evaluate the coincided alignment of the lisfranc joint. Accurate accessment on AP & lateral & $30^{\circ}$ oblique projection of radiographs are very adventageous & important, and next final outcome was detected. : 1. Coincided alignment below 1mm and unfolded lisfranc joint on AP projection was well visalized on 1st cuneiform-metatarsal lateral border and 2nd cuneiform-metatarsal medial border. 2. Coincided alignment below 1mm and unfolded lisfranc joint on oblique projection was well visualized on 2nd cuneiform-metatarsal lateral border and 3rd cuneiform-metatarsal medial border and 3rd cuneform-metatarsal lateral border. 3. More proximal location of 2nd lisfranc joint compared to another joint was 196 cases (98%). It is due to inceleration of 2nd metatarsal base between 3rd & 1st cuneiform. 4. 3rd lisfranc joint was volarward position compared to 2nd listranc on lateral projection at 191 cases (95.5%). It's due to anterior covexity of lisfranc joint. 5. Wide dorsal sided 2nd lisfranc is investigated at 189 cases (94.5%). Because of it. 2nd & 3rd lisfrances are mainly volar dislocated usually. 6. Notching on 5th metatarsal base is visible on 171 cases (85.5%). 7. 4th lisfranc joint had offset normally within $2\sim3mm$ at 98 cases (49%). 8. 5th Lisfranc joint had normally offset within $2\sim3mm$ at 99 cases (49.5%). 9. On lateral projection, slight dorsal location of cuneiform to metatarsal base is investigated at 82 cases (41%).

  • PDF

점혈기공요법(點穴氣功療法)을 통해 본 수기요법(手氣療法)의 문헌적(文獻的) 연구(硏究) (Observed through the stories of herbal remedies Jeom-hyeol-gigong, philological research of Su-gi therapy)

  • 김인창;서윤희
    • 대한의료기공학회지
    • /
    • 제11권1호
    • /
    • pp.236-261
    • /
    • 2009
  • 'Jeom-hyeol-gigong(點穴氣功)' gives a drill, Gi(氣) as a place to jam. This pathogen(邪氣) is removed. Given the low places and supplement it energy to flow up the well is the cure. This is an internal organ and muscular Gi allows a natural flow. Blood, one that moves and guides Gi is Gi I still feel that it makes any blood, making you feel good in life is flowing with vitality. Gi driving our whole body, while supplying vital energy and blood circulation, helping to defend the body is functioning. 'Jeom-hyeol-gigong' principle of Gi where the blockages to flow naturally energy is to let the flow. Aura of the voluntary and proactive action will be to have healthy bodies. Gi as a whole-body blood circulation leading to the cells in each tissue to supply energy and nutrients to every cell as the original principles of free activities that will maximize your life. Gi to prevent the three causes Internal causes: 5 greed and 7 emotions External causes: climate, food, pathogens, stress, etc. The internal nor the external causes: internal and external factors that cause the complex elements, incorrect position of the bone caused by an imbalance Heart disease will be police officers and raise their resistance to disease than the body, what jung-gi(正氣) have to develop. Beneficial to human body's resistance to raise the jung-gi people young-gi(營氣) and wi-gi(衛氣) should be enhanced. If the form is perfectly possible, Gi cycle itself should not have to breathe. Abdominal diagnosis 'bok-su-ap-an-beop(伏手壓按法)', 'sam-ji-tam-an-beop(三指探按法)' hands are like this, which outlined five viscera in order to understand the problem, the lower side of the clavicle (lung), the pit of stomach (Heart), both the lower ribs (liver), navel below (kidney) can be diagnosed at such areas. In each area of the skin, abdominal muscle tension, aching, or pressing a fuss about, beating the ruling of the state and the problem is a clue. And mo-hyeol(募穴) and certain Acupressure group, the chest, back, belly, so that scattered around each' book 'of the problem can be found. This is also the target of such a diagnosis, such as shape, color of skin, muscle Mostly the scope of the pitch in the cervical spine is broad across the hips. sugi(手氣) method that 'an method(按法) and 'ma method(摩法), bak method(拍法) is.

한국인에 대한 새로운 관절주위 잠김금속판의 해부학적 적합성: 사체를 이용한 연구 (Anatomic Conformity of New Periarticular Locking Plates for Koreans: A Biomechanical Cadaveric Study)

  • 윤용철;오종건;김영우;김학준;문홍주;김남렬
    • Journal of Trauma and Injury
    • /
    • 제26권3호
    • /
    • pp.163-169
    • /
    • 2013
  • Purpose: This study was conducted to confirm the anatomic conformity of the new periarticular locking plates designed by Zimmer on Korean adult bones and to identify the structures at risk during the application of these implants. Methods: The study was performed on the humerus, radius, and tibia of 10 adult cadavers(6 males and 4 females) procured from the cadaveric lab of our hospital. Anteroposterior (AP) and lateral X-rays were taken to confirm that the cadavers were free of any unusual lesions or anatomic variations. We used the 3.5-mm proximal humerus plate, 2.7-mm distal radius plate, 3.5- and 5.0-mm proximal tibia plates, and 3.5-mm distal tibia plate developed by Zimmer, Inc. (Zimmer periarticular locking plate). The longest plate from each group was used to confirm anatomical conformity. Standard approaches were used for each area, and soft tissue was retracted in order to pass the plate beneath the muscle. The position of the plate was confirmed using standard AP and lateral view X-rays. After this procedure had been completed, the region was dissected along the length of the implant to determine the conformity of the implant to bone and the penetrations of screws into the articular surface or violations of any vital structures, such as nerves, blood vessels, or tendons. Results: Excellent anatomical conformity was observed with Zimmer periarticular locking plates for Korean adults. The tibial nerve and the posterior tibial artery were found to be structures at risk when applying a distal tibial plate. Conclusion: Additional posterolateral fixation is recommended when dealing with cases of tibial plateau fracture when the fracture line extends to the posterolateral cortex. We recommend taking proper views using 10~15 degrees of internal rotation to ensure correct screw length and, thus, avoid penetration of vital structures and tendons.

GPS정보를 이용한 위치기반 핸드오프 시스템의 설계 및 구현 (Design and Implementation of Geographical Handoff System Using GPS Information)

  • 한승호;양승철;김종덕
    • 한국통신학회논문지
    • /
    • 제35권1A호
    • /
    • pp.33-43
    • /
    • 2010
  • 최근 사용자들은 IEEE 802.11 무선랜이 탑재된 이동단말을 통해 인터넷, VoIP등과 같은 실시간 멀티미디어 서비스를 받고자 한다. 넓은 지역에서의 이동성을 지원하기 위하여 액세스포인트간의 핸드오프는 필수적이다. 하지만 기존 IEEE 802.11의 핸드오프 방식은 연결의 단절이 발생하며, 연결단절 인지와 채널 검색시간이 대부분의 지연시간을 차지하고 있다. 또한 노드의 이동방향, 위치 등을 고려하지 않고 주위 환경에 민감한 신호 세기만 고려하여 액세스포인트를 선택하기 때문에 충분한 대역폭을 받기 힘들다. 그렇기 때문에 실시간 멀티미디어 서비스를 제공하기 위하여 노드의 연결단절시간을 줄이고 충분한 대역폭을 받을 수 있는 알고리즘이 필요하다. 이에 본 논문에서는 실외환경에서 사용하는 GPS 위치정보를 이용하여 노드의 이동에 따른 핸드오프 지점을 예측하고, 이동방향, 속도와 신호세기를 이용하여 높은 전송 대역폭을 받는 핸드오프 알고리즘을 제안한다. 제안한 알고리즘을 구현하고 성능평가를 통하여 Layer2의 연결단절시간을 3.7ms로 줄이고 약 24.8%의 대역폭 향상을 통해 알고리즘의 우수함을 확인했다.

보호자의 위치를 고려한 WiFi 기술 기반 이동 객체의 위치 관리 시스템 (Location Management System of Moving Objects to Considering Location of Guardian based on WiFi Technology)

  • 김진덕;강효운
    • 한국정보통신학회논문지
    • /
    • 제17권10호
    • /
    • pp.2345-2351
    • /
    • 2013
  • LBS는 이동 객체의 위치를 정확하게 확인하기 위해 주로 GPS 기술을 이용한다. 그러나 지금까지 휴대폰의 WiFi 기술을 활용한 이동 객체의 위치 관리 기법을 제시되지 않았으며, 또한 보호자의 위치를 고려한 이동 객체의 위치 관리 기법 또한 제시되지 않았다. 이 논문에서는 보호자의 위치를 고려한 WiFi 기반 이동 객체의 위치 관리 시스템을 제안한다. 구체적으로 미아 찾기 및 통보를 위해 다음과 같은 3가지 방법을 제안한다. 1) 스마트폰 앱 기반, 2) 관제 서버 기반, 3) 관제 서버와 고정 AP(Access Point) 기반 방법이 그것이다. 시스템은 보호자의 위치를 고려하므로 즉각적인 보호 아동 상태의 확인이 가능하다.

무지외반증에서 종자골 전이 정도가 치료결과에 미치는 영향 (The Effect of Sesamoid Position on Results of Treatment for Hallux Valgus)

  • 유총일;이동호;김휘택
    • 대한족부족관절학회지
    • /
    • 제8권2호
    • /
    • pp.131-137
    • /
    • 2004
  • Purpose: We evaluated the results of various surgical treatments for hallux valgus with and without attempting to correct sesamoid subluxation. Materials and Methods: Thirty-one cases in 26 patients were involved in this study: Group I (15 cases) - surgery performed only to correct the hallux valgus angle (HVA) and the first-second intermetatarsal angle (IMA) in AP view; Group II (16 cases) - surgery performed to correct HVA and IMA and also to reduce the subluxation of sesamoid. The degree of sesamoid subluxation was measured from a pre- and intraoperative sesamoid tangential views. For both groups, we analysed the status of the sesamoid in pre- and postoperative radiographs and performed clinical evaluation using the Mayo clinic forefoot scoring system. Results: The average amount of correction during postoperative period and loss of correction at last follow-up in the sesamoid tangential view were as follows: soft tissue procedures (5 cases) - group I: grade $1.0{\pm}0.4/1.5{\pm}0.3$ and group II: grade $2.0{\pm}0.9/0.5{\pm}0.08$; chevron osteotomy (12 cases) - group I: grade $1.0{\pm}0.5/1.2{\pm}0.3$ and group II: grade $2.2{\pm}0.7/0.9{\pm}0.2$; proximal metatarsal osteotomy (14 cases) - group I: grade $4.0{\pm}0.4/1{\pm}0.2$ and group II: grade $4.7{\pm}1.1/0.8{\pm}0.1$. In clinical evaluation, more than 93% of the feet had a good result in both groups. The analysis of these data for each treatment type did not show any statistically significant differences between groups I and II. Conclusion: The radiologic and clinical results did not validate our attempts to reduce the sesamoid during surgery.

  • PDF

Genome-Wide Association Study of Orthostatic Hypotension and Supine-Standing Blood Pressure Changes in Two Korean Populations

  • Hong, Kyung-Won;Kim, Sung Soo;Kim, Yeonjung
    • Genomics & Informatics
    • /
    • 제11권3호
    • /
    • pp.129-134
    • /
    • 2013
  • Orthostatic hypotension (OH) is defined by a 20-mm Hg difference of systolic blood pressure (dtSBP) and/or a 10-mm Hg difference of diastolic blood pressure (dtDBP) between supine and standing, and OH is associated with a failure of the cardiovascular reflex to maintain blood pressure on standing from a supine position. To understand the underlying genetic factors for OH traits (OH, dtSBP, and dtDBP), genome-wide association studies (GWASs) using 333,651 single nucleotide polymorphisms (SNPs) were conducted separately for two population-based cohorts, Ansung (n = 3,173) and Ansan (n = 3,255). We identified 8 SNPs (5 SNPs for dtSBP and 3 SNPs for dtDBP) that were repeatedly associated in both the Ansung and Ansan cohorts and had p-values of < $1{\times}10^{-5}$ in the meta-analysis. Unfortunately, the SNPs of the OH case control GWAS did not pass our p-value criteria. Four of 8 SNPs were located in the intergenic region of chromosome 2, and the nearest gene (CTNNA2) was located at 1 Mb of distance. CTNNA2 is a linker between cadherin adhesion receptors and the actin cytoskeleton and is essential for stabilizing dendritic spines in rodent hippocampal neurons. Although there is no report about the function in blood pressure regulation, hippocampal neurons interact primarily with the autonomic nervous system and might be related to OH. The remaining SNPs, rs7098785 of dtSBP trait and rs6892553, rs16887217, and rs4959677 of dtDBP trait were located in the PIK3AP1 intron, ACTBL2-3' flanking, STAR intron, and intergenic region, respectively, but there was no clear functional link to blood pressure regulation.