• Title/Summary/Keyword: AMOUNG OF USE

Search Result 3, Processing Time 0.019 seconds

Use Impacts on Environmental Deteriorations on and around Trails in Odaesan National Park (오대산 국립공원 이용에 따른 등산로 및 주변환경훼손)

  • 권태호;오구균;이준우
    • Korean Journal of Environment and Ecology
    • /
    • v.9 no.2
    • /
    • pp.211-220
    • /
    • 1996
  • 5 major trails of Odaesan National Park were selected to investigate the use impacts on environmental deterioration of trail accreding to the different amunt of use. The entire width, bare width, maximum depth and slope of trail as the trail comdition surveyed at the total of 120 points were significantly greater on the more heavily-used trail. Major deterioration types of trail were root-exposure, rock-exposure, deepening and divergence in order of frquency and trail conditions of deteriorated points were significantly different from those of non-deteriorated points. The damaged area more severe than Class 4 on trail reached about 379m$^{2}$/km in total, and especcially about 1,196m$^{2}$/km in the section between Chodmyolbogung and Pirobong of Sangwonsa trail. The dominant trees of trail edge vegetation could be Quercus mongolica in upper layer, but in lower layer Rhododecdron schilipenbachii for slope and Actinidia arguta for ridge. Coverage and number of individuals of lower vegetation in trail edge were the lowest on the Sangwonsa trail of the largest use amount, and each trail was dissimilar in species composition of lower layer of edge vegetation.

  • PDF

THE EFFECT OF OBTURATION TECHNIQUES ON THE APICAL MICROLEAKAGE OF ROOT CANALS (근관충전방법에 따른 치근단부 근관의 미세누출에 관한 연구)

  • Yoo, Hyung-Jun;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.213-222
    • /
    • 1998
  • Advisor: Prof. The quality of apical seal obtained with 3 different gutta-percha obturation techniques was compared in 49 recently extracted single rooted teeth. The root canals were instrumented using step-back technique and obturated with laterally condensed gutta-percha, Continuous Wave gutta-percha, and hybrid technique. Teeth were suspended in black India ink for 7 days, cleared, and then examined under a stereomicroscope at ${\times}10$ magnification. The results were as follows; 1. All experimental groups produced favorable apical seal. 2. The mean leakage was $0.23{\pm}0.25mm$ for group 1, $0.17{\pm}0.21mm$ for group 2, and $0.19{\pm}0.23mm$ for froup 3, but there was no statistical difference amoung them. Within the limits of the results of this experiment, the Continuous Wave gutta-percha obturation technique demonstrated relatively favorable apical sealing effect and shorter obturation time. Thus, it is thought that this obturation technique is a acceptable method for clinical use but further studies on this metter should be conducted.

  • PDF

THE EFFECT OF NiTi ROTARY INSTRUMENTATION ON THE CHANGE OF APICAL ROOT CANAL CURVATURE (NiTi Rotary Instrumentation이 근관만곡도 변화에 미치는 영향)

  • Lim, Hyoung-Tae;Hong, Chan-Ui;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.257-268
    • /
    • 1998
  • During cleaning and shaping of narrow and curved canals, it is very difficult or nearly impossible to maintain the original canal shape. Procedural accidents such as, ledge, zipping, perforation, and instrument breakage are frequently occurred and even may lead to failure of endodontic therapy. To prevent these kinds of accidents, various instrumentation techniques and materials have been introduced. Recently some nickel titanium (NiTi) files are introduced and it is reported that These NiTi files created rounder preparations with less transportation than conventional instruments in curved canals. This study compared the change of the canal curvature and procedural accidents after instrumentation produced by stainless steel K-flexo file, and NiTi rotary files (Profile 29 and Quantec 2000). Thirty narrow and curved canals (25-45 degree) of extracted human molars were randomly divided into three groups. In group 1, canals were instrumented using a step-back and watch-winding/pull motion with K-flexo files. In group 2, canals were prepared with Profile 29. Group 3, canals were prepared with Quantec 2000 files. Before and after preparation of canals, periapical radiographs were taken and scanned. The change of canal curvature were measured using Photoshop 4.0 program and the incidence of procedural accidents were also evaluated. The results were as follows: 1. All group showed some loss of canal curvature after instrumentation. 2. Average loss of canal curvature was $6.70{\pm}5.31$ degree for group 1, $3.80{\pm}2.57$ degree for group 2, and $5.40{\pm}4.83$ degree for group 3. All group There was significant change in curvature between before and after instrumentation (p<0.05). But there was no statistical difference amoung 3 groups. 3. In group I, there were no procedural accidents, such as ledging, perforation, or instrument fracture. In group 2, two cases of ledge and one case of instrument fracture were produced Goup 3, each one case of ledge, perforation and instrument fracture were occurred. Whthin the limits of above results, It seems that NiTi rotary instrumentation is not All Mighty and if we use uncarefully, it is more dangerous to produce some procedural accidents than conventional hand files. But more studies should be taken to evaluate the exact effects of NiTi rotary instrumentations.

  • PDF