• Title/Summary/Keyword: AIR 모델

Search Result 2,267, Processing Time 0.029 seconds

A Modeling Study on the Transport of Acid Pollutant by Regional Acid Deposition Model -Spacial Pattern and Variation of Air Pollutants on Eastern Asia and Central Part of Korea- (산성우모델에 의한 산성강하물의 수송에 관한 연구 - 동아시아 및 우리나라 중부지방의 대기오염물질 시공간분포 -)

  • Lee, Chong Bum;Cho, Chang Rae;Byun, Dae Won
    • Journal of Environmental Impact Assessment
    • /
    • v.8 no.1
    • /
    • pp.1-16
    • /
    • 1999
  • The acid deposition and photochemical modeling study was performed on the Eastern Asia using Regional Acid Deposition Model(RADM). The results of this study show that horizontal distribution of $SO_2$, concentration and dry deposition flux was higher in Beking, Shanghai and central part of Korea. However distribution pattern of sulfate and $O_3$ concentration calculated by RADM were not similar to emission pattern. In daytime, $SO_2$, sulfate and $O_3$ were mixed to whole PBL but in nighttime because of inversion layer these pollutants were suppressed to lower level.

  • PDF

Development of An Optimum Model Using Safety-Related Equipment Qualification for the Air Conditioner in the Nuclear Power Plant (원자력 발전소에 사용되는 항온항습기의 안전관련 기기검증을 통한 최적 모델 개발)

  • Sur, Uk-Hwan;Lee, Yeong-Seop
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.1 s.73
    • /
    • pp.1-5
    • /
    • 2006
  • The damage of important equipments for the nuclear power plant by the earthquake brings the loss of human lives and economic losses. Therefore safety-related equipment of nuclear power plant must be proved that function must be designed and structural integrity so that it can be maintained also from accident condition of various kinds. In this study, the computer room air conditioner to be delivered at the nuclear power plant applied to this qualification, try to develop an optimum model. This model ended up with good results which were under suitably allowable conditions about structurally safe earthquake.

Development of Analysis Model for Combustion System of Coal Fired Power Plant (석탄화력발전소 연소계통의 해석을 위한 모델개발)

  • Jung, Hwan-Joo;Park, Yong-Sub;Kim, Seong-Hwan;Chang, Young-Hak;Moon, Chae-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.392-394
    • /
    • 2001
  • Coal power plants are large, non-linear systems with numerous interactions between its component parts. In the analysis of such complex systems, dynamic simulation is recognized as a powerful method of keeping track of the myriad of interactions. This paper shows and discusses the developed analysis model, such as the forced draft fan the primary air fan, the furnace and burner system, air preheater and induced draft fan, etc. in accordance with BMCR condition of boiler using the Modular Modeling System(MMS) software.

  • PDF

The Improvement of the Performance of Solar Cooling and Heating Systems (III) - Development of One Dimensional Analytic Model for the Evaluation of Stratification Coefficients - (태양열에 의한 냉방 및 난방시스템의 성능향상 (III) - 성층화계수의 예측을 위한 1차원 해석모델의 개발 -)

  • Yoo, J.K.;Ro, S.T.;Lee, J.S.;Chung, S.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.1
    • /
    • pp.55-63
    • /
    • 1989
  • A one dimensional analytic model for the prediction of the stratification coefficient of a liquid-based solar heating system is developed. The stratification coefficient, $K_s$, is defined as the ratio of the actual useful energy gain to the energy gain that would be achieved if there were no thermal stratification in the storage tank. Previous studies incorporated only collector-side effects, but in this study both the collector and load-side effects are included for the overall performance evaluation.

  • PDF

Performance evaluation technique of a heat exchanger using a transient response analysis (과도응답해석을 이용한 열교환기의 성능평가방법에 관한 연구)

  • Park, B.K.;Hong, T.;Park, S.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.81-90
    • /
    • 1999
  • The performance evaluation technique of a heat exchanger is described by using a transient response analysis for the determination of an average heat transfer coefficient. The model using a finite difference method can accommodate arbitrary inlet fluid temperature as well as longitudinal conduction. Temperature histories are obtained from the experiments at the inlet and outlet of test core. Heat transfer coefficient and friction factor of the plate array are obtained in short times using the data reduction program of transient response analysis in the single-blow method. The results agree very well with theoretical results. It is shown that the rms deviations are very small and the performance evaluation technique gives rapid and accurate results.

  • PDF

Numerical Analysis of Swirling Turbulent Flow in a Pipe (원관내 난류 선회류의 수치해석)

  • Lee, D.W.;Kim, K.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.3
    • /
    • pp.396-405
    • /
    • 1995
  • Numerical calculations are carried out for the swirling turbulent flow in a pipe. Calculations are made for the flow with swirl parameter of 2.25 and the Reynolds number of 24,300. The turbulence closure models used in these calculations are two different types of Reynolds stress model, and the results are compared with those of $k-{\varepsilon}$ model and the experimental data. The finite volume method is used for the discretization, and the power-law scheme is employed as a numerical scheme. The SIMPLE algorithm is used for velocity-pressure correction. The computational results show that GL model gives the results better than those of SSG model in the predictions of velocity and stress components.

  • PDF

Prediction of strongly swirling turbulent flow downstream of an abrupt pipe expansion (원관내 급확대부 하류의 강선회난류에 관한 수치해석)

  • Kim, K.Y.;Chang, Y.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.1
    • /
    • pp.23-32
    • /
    • 1997
  • Swirling turbulent flows downstream of an abrupt axisymmetric expansion in a pipe are analyzed numerically by a second-order turbulence closure. Predictions for the flows without swirl and with strong swirl are obtained. The governing differential equations are discretized by finite volume approach. The results show that the on-axis recirculation induced by the strong swirl is correctly reproduced. The predictions for mean velocity components and turbulent normal stresses agree well with experimental data far downstream of expansion, but show large discrepancies in wall-bounded recirculation zone.

  • PDF

Simulation of a Polymer-Water Adsorption Refrigerator using Plate-Type Adsorption Heat Exchangers (판형 흡착열교환기를 사용한 폴리머-물 흡착식 냉동기의 성능예측)

  • Kim, Dong-Seon;Lee, Dae-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.2
    • /
    • pp.94-102
    • /
    • 2015
  • A hydroscopic polymer is used as the adsorbent in an adsorption refrigeration system. A pair of plate-type heat exchangers, thinly coated with the polymer, is simulated using a two-dimensional transient model to predict performance of the system. It is predicted that the system would yield 0.57 kW SCP and 0.47 COP at $80^{\circ}C$ heating and $30^{\circ}C$ cooling temperatures. In comparison with a conventional silica gel-water system, the COP is comparable but SCP is about three times larger. The slow mass diffusion rate of the polymer should be improved for better performance.

Integral Approximate Solutions to a One-Dimensional Model for Stratified Thermal Storage Tanks (성층화된 축열조의 1차원모델에 대한 적분 근사해)

  • Chung, Jae-Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.468-473
    • /
    • 2010
  • This paper deals with approximate integral solutions to the one-dimensional model describing the charging process of stratified thermal storage tanks. Temperature is assumed to be the form of Fermi-Dirac distribution function, which can be separated to two sets of cubic polynomials for each hot and cold side of thermal boundary layers. Proposed approximate integral solutions are compared to the previous works of the approximate analytic solutions and show reasonable agreement. The approach, however, has benefits in mathematical difficulties, complicated solution form and unstable convergence of series solution founded in the previous analytic solutions. Solutions for a semi-infinite region, which have simple closed form solutions, give close agreement to those for a finite region. Thermocline thickness is obtained in closed form and shows proportional behavior to the square root of time and inverse proportional behavior to the square root of flow rate.

A Study on Diagnosing Fouling of Heat Exchangers of a Hybrid Heat Pump (하이브리드 열펌프 열교환기 오염 진단 연구)

  • Shin, Younggy
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.5
    • /
    • pp.240-246
    • /
    • 2014
  • A fault detector was developed for heat exchangers of a hybrid heat pump (HP) for household. The proposed detector can be applied directly to raw operating data. It is to monitor a tracking error between a measured saturation temperature and its state observer. The observer was estimated from a state-space model simulating dynamics of a heat exchanger. The real hybrid HP was substituted with a dynamic simulator that implemented two-phased heat transfer and was validated by experimental data. And artificial fault data were generated using the simulator. Diagnosing the data showed the following. The residual calculated from the state observer error shows a relatively robust consistency with respect fouling level. The fault detector is practically useful because it detects a threshold fouling beyond which the performance starts to deteriorate significantly.