• Title/Summary/Keyword: AIR 모델

Search Result 2,267, Processing Time 0.029 seconds

Numerical Simulation for Recirculation of Air Mass in the Coastal Region Using Lagrangian Particle Dispersion Model (라그랑지안 입자확산모델을 이용한 광양만 권역에서의 공기괴 재순환현상 수치모의)

  • Lee, Hwa-Woon;Lee, Hyun-Mi;Lee, Soon-Hwan;Choi, Hyun-Jung
    • Journal of Environmental Science International
    • /
    • v.19 no.2
    • /
    • pp.157-170
    • /
    • 2010
  • Air mass recirculation is a common characteristic in the coastal area as a result of the land-sea breeze circulation. This study simulates the recirculation of air mass over the Gwangyang Bay using WRF-FLEXPART and offers a basic information about the effective domain size that can reflect recirculation. For this purpose, WRF is set up four nested domains and three cases are selected. Subsequently FLEXPART is operated on the basis of WRF output. During the clear summer days with weak wind speed, particles that emitted from Yeosu national industrial complex and Gwangyang iron works flow into emission sources because of the land-sea breeze. When land-sea breeze is strengthen, the recirculation phenomena appears clearly. However particles aren't recirculated under weak synoptic condition. Also plume trajectory is analyzed and as a consequence, the smallest domain area have to be multiplied by 1.3 to understand recirculated dispersion pattern of particles.

Analysis on High Concentration Air Pollution Cases in Gimhae Region Using the WRF Numerical Model (중규모 수치모델을 이용한 김해지역 고농도 대기오염 사례 분석)

  • Jung, Woo-Sik;Lee, Bo-Ram;Park, Jong-Kil;Do, Woo-Gon
    • Journal of Environmental Science International
    • /
    • v.22 no.8
    • /
    • pp.1029-1041
    • /
    • 2013
  • In this study, eight episode days of high-concentration $PM_{10}$ occurrences in the Gimhae region between 2006 and 2011 were analyzed. Most of them appeared in winter and the highest concentration was observed around 12 LST. Furthermore, the wind direction, wind velocity, and temperature elements were compared with observed values to verify the WRF numerical simulation results used in this study, and they simulated well in accordance with the trend of the observed values. The wind was generally weak in the high-concentration episode days that were chosen through surface weather chart and the numerical simulation results for wind field, and the air pollutants were congested due to the effects of the resulting local winds, thereby causing a high concentration of air pollutants. Furthermore, the HYSPLIT model was performed with the WRF numerical simulation results as input data. As a result, they originated from China and flowed into Gimhae in all eight days, and the lowest concentration appeared on the days when recirculation occurred.

A study on the free surface vortex in the pipe system (배관내 자유수면에서 와류현상에 대한 연구)

  • 오율권;장완호;이종원;김상녕
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.11
    • /
    • pp.2126-2135
    • /
    • 1992
  • In order to prevent the decay heat removal system from failure due to air entrainment or free surface vortex in the piping system, a set of simulating experiments for the midloop operation of nuclear power plant was performed. Through these experiments, a relation between the dimensionless numbers, such as submergence H/d, froude number, reynolds number, was found. However, the effect of reynolds number was negligible for the operation conditions of Nuclear power plant. It was also found that the perturbation of the system by the disturbance such as pump start, valve operation, etc., has a strong effect on the free surface vortex. Furthermore, from a view point of reactor safery, a modified inlet device of reducer type is strongly recommendable for the prevention of air entrainment.

Computational Heat Transfer Analysis of Dish Type Solar Receiver Using the Transient model (CFD를 이용한 접시형 태양열 집열기의 과도 열전달 모델 해석)

  • Oh, Sang-June;Lee, Ju-Han;Seo, Joo-Hyun;Lee, Jin-Gyu;Cho, Hyun-Seok;Seo, Tae-Beom
    • New & Renewable Energy
    • /
    • v.4 no.4
    • /
    • pp.72-79
    • /
    • 2008
  • A numerical and experimental studies are carried out to investigate the transient heat transfer characteristics of 5kWth dish type solar air receiver. Measured solar radiation and temperatures at several different locations are used as boundary conditions for numerical a. Many parameters' effects (reflectivity of the reflector, the thermal conductivity of the receiver body, transmissivity of the quartz window, etc.) on the thermal performance are investigated. Discrete Transfer Method is used to calculate the radiation heat exchange in the receiver. A transient heat transfer model is developed and the rate of radiation, convection and conduction heat transfer are calculated. Comparing of the experimental and the numerical results, results of both are in good agreement. Using the numerical model, the transient heat transfer characteristics of volumetric air receiver for dish type solar thermal systems are known and the transient thermal performance of the receiver can be estimated.

  • PDF

Mixing Augmentation with Cooled Pylon Injection in Scramjet Combustor (냉각 파일런 분사를 이용한 스크램제트 연소기 내 혼합증대)

  • Lee, Sang-Hyeon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.1
    • /
    • pp.20-28
    • /
    • 2010
  • The mixing characteristics of pylon injection in a Scramjet combustor and effects of film cooling to protect pylon from air-heating were investigated. Three-dimensional Navier-Stokes equations with $k-{\omega}$ SST turbulence model were used. Fuel hydrogen and air were considered as coolants. There were remarkable improvements of penetration and mixing rate with the pylon injection. There was also over-heating on the front surface of the pylon without film cooling. The coolant injected parallel to the front surface of the pylon protects the pylon from over-heating.

Development of Diagnosis of Trouble Model for Effective Operation of Air-compressor (효율적인 공기압축기 운영을 위한 이상진단모델 연구)

  • Im, Sang Don;Jung, Young Deuk;Kim, Jong Rae
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.3
    • /
    • pp.239-248
    • /
    • 2014
  • Most systems used in industrial sites, actually have non-linearity and uncertainty. Therefore there are a lot of difficulties in evaluating conditions of these systems. Generally, the quantitative analysis and expression are found hard because the general public cannot easily make an accurate interpretation on the systems. Thus development of a system that utilizes an expertise from skilled analysts is required. In this research, a real-time sensor signal conditioning system and Fuzzy-expert system have been separately set up into an inference algorithm. So that it ensures a fast, accurate, objective and quantitative operational condition value provided to the manager. Therefore, FE_AFCDM is suggested in this literature, as an effective system for diagnosing the problems related to the air compressor. It can quantify the uncertain and absurd condition to operate the air compressor facilities safely and financially.

Air Damping Evaluation for Laterally Driven Electrostatic Repulsive-Force Microactuators Using Creeping Flow Model (수평 구동형 정전 반발력 마이크로엑추에이터의 Creeping 유동 모델에 의한 공기 감쇠)

  • Lee, Gi-Bang;Seo, Yeong-Ho;Jo, Yeong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.11
    • /
    • pp.581-588
    • /
    • 2001
  • This paper presents theoretical and experimental study on the quality-factor of the laterally oscillated electrostatic microactuator, driven by a lateral repulsive-force generated by the asymmetry of planar electric field. The quality-factor of the repulsive-force microactuator using a creeping flow model of the ambient air is evaluated. By filling the simulation results of damping force, we evaluate the dimensionless damping force, $\alpha$, thereby obtaining an analytical damping force, F, in the form of $F=\mu\; \alphaUL,\; where\; \mu,$ U and L denote the air viscosity, the velocity and the characteristic length of the movable electrodes. The measured quality-factor increases from 12 to 13 for the DC bias voltage increased from 60V to 140v. The theoretical quality-factor estimated from the creeping flow model increases from 14.9 to 18.7. Characteristics of quality-factor of the repulsive-force microactuator have been discussed and compared with those of the conventional attractive-force microactuator.

  • PDF

Derivation of New Box Model to Analyze the Air Pollution Trends in a Metropolitan Area (대도시 대기오염 추세 분석을 위한 새로운 박스모델의 유도)

  • Kim Seogcheol;Joh Seunghun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.3
    • /
    • pp.377-397
    • /
    • 2005
  • A new box model is proposed to describe the dynamic trend of the spatially averaged concentrations of pollutants over a large urban area such as metropolitan Seoul. Being averaged temporally and spatially over a thresh-hold scales, the dynamics of the pollutant concentration becomes simple enough that the governing equation can be expressed in an explicit algebraic form as a function of several meteorological factors and the pollutant emission rate. The single most important meteorological factor is the wind speed dominating the daily variations of the pollutant concentrations. Given the meteorological data from the surface station in the metropolitan Seoul, the model concentration shows excellent agreement with observations from January 1, 1990 to December 31, 2000: the modeling uncertainty, for example, of $NO_2$ concentrations, defined as mean differences between the model concentrations and observations is $16\%$ of the model concentrations. Even for $PM_{10}$ of which secondary sources are considered to be very important and simple box model is irrelevant to, the model performance turns out good, modeling uncertainty being about $32\%$.

Development of standardized model of building GIS in Airport Movement Area (공항 이동지역 지리정보 구축 표준화 모델개발)

  • Kim, Byung-Jong;Kim, Won-Kyu;Lee, Dong-Hoon
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.17 no.3
    • /
    • pp.51-60
    • /
    • 2009
  • For the world's safest air traffic, safety-related areas through the large investment made in a sufficient safe level, but the airport's lack of safety management is concerned about the safety. Airside area is essential area for the flights, and activities of safe management in airside area is very important. Grafting of airside safety management and IT, importance of the safety and efficiency is growing. Advanced airports of world has applied GIS over 10 years ago, and through applying GIS, Airports GIS has been a specialized area. Therefore, this research is for geographic information standards and related laws, providing a guideline of regulations and standards for AIXM (Aeronautical Information Exchange Model), RTCA DO-272A (USER REQUIREMENTS FOR AERODROME MAPPING INFORMATION), FAA Advisory Circular 150/5300 -18A (General Guidance and Specifications for Submission of Aeronautical Survey to NGS: Field Data Collection and Geographic Information System Standards), and by analyzing aviation information and air map(notice "Civil Aviation Safety Authority No. 2009-1"), provide the direction of standardization for air map.

  • PDF

Estimation of Wall Wetting Fuel at Intake Port and Model Based Prediction A/F in a S.I. Engine (가솔린 엔진에서 액막 연료량 추정 및 이를 이용한 공연비 예측에 관한 연구)

  • 황승환;이종화;박경석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.8
    • /
    • pp.116-122
    • /
    • 1999
  • According to the stringent exhaust emission regulation, precise control of air fuel ratio is one of the most important issues on gasoline engine. Although many researches have been carried out to identify the fuel transport phenomena in a port fueled gasoline engine, complexity of fuel film behavior in the intake port makes it difficult. The fuel film behavior was investigated recently by using visualization method and these gave us qualitative understanding. The purpose of this study is to estimate of wall wetting fuel in the intake port and the inducted fuel mass was predicted by using wall wetting fuel model . The model coefficient($\alpha$,$\beta$) and fuel film mass on the port wall were determined from measured in-cylinder HC concentration using FRFID after injection off. The fuel film mass was increased, but $\alpha$(ratio of directly inducted fuel mass into cylinder from injected fuel mass) was decreased with increasing load at the same engine speed. $\beta$is nearly constant value(0.8~0.9). when injected fuel mass is varied at 1500rpm , the calculated air fuel ratio using well wetting fuel model was nearly the same as measured by UEGO.

  • PDF