• Title/Summary/Keyword: AIR 모델

Search Result 2,267, Processing Time 0.027 seconds

Optimal Control Algorithms for the Full Storage Ice Cooling System (전축열방식 빙축열 시스템의 최적제어 알고리즘)

  • 한도영;이준호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.4
    • /
    • pp.350-357
    • /
    • 2002
  • Optimal control algorithms for the full storage ice cooling system were developed by using a dynamic simulation program. Control algorithms for the storage charging mode were developed for the chiller outlet temperature setpoint control and the chiller capacity control. Control algorithms for the storage discharging mode were developed for the proper mode selection, the storage-only mode control, and the storage-priority chiller-shared mode control. Two different cases of the expected outdoor air temperature profile and the expected cooling load profile were used to analyze the effectiveness of these algorithms. Simulation results show the energy savings and the satisfactory controls of the ice storage system. Therefore, control algorithms developed for this study may effectively be used for the improved control of the ice storage cooling system.

Flow Distribution in Manifold Using Modified Equal Pressure Method (수정된 등압법을 이용한 매니폴드의 유량분배)

  • Ye, Huee-Youl;Kim, Doo-Hwan;Lee, Kwan-Soo;Cha, Woo-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.3
    • /
    • pp.176-185
    • /
    • 2009
  • A general flow distribution model and a simple process of numerical analysis, which can be applied to multi-pass systems with manifolds, are presented. A numerical procedure, namely a modified equal pressure method based on the discrete model, was developed to predict flow rates at branch tubes. The predicted pressure distribution agreed well with the previous research with the average error less than 11%. A parametric study was performed to demonstrate the effect on the flow distribution.

Experimental Study on Fuel-Air Mixing Using Flat Plate/Cavity in Supersonic Flow (초음속 유동장 내 평판/cavity를 이용한 연료-공기 혼합의 실험적 연구)

  • Kim, Jeong-Woo;Jeong, Eun-Ju;Kim, Chae-Hyoung;Jeung, In-Seuck
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.319-322
    • /
    • 2006
  • Rapid mixing of air-fuel (<1 ms) is needed to accomplish supersonic combustion. In this experiment, helium was injected laterally in to the Mach 1.92 air flow. 2 kinds of model, flat plate/cavity, were used in this experiment and images were taken by schlieren visualization. Pressure was affected by shock structure in the supersonic duct, and penetration height was increased by increasing J. Penetration height was higher in the cavity model than flat plate model.

  • PDF

Thermal Load Simulation Analysis on Model Building Estimating Optimum Heat Source Capacity (최적 열원용량 산정을 위한 모델건물 공조부하 시뮬레이션 분석)

  • Park, Jong-Il;Kim, Se-Hwan;Lee, Sung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.6
    • /
    • pp.427-433
    • /
    • 2007
  • Generally, H.V.A.C load capacity in early planning phase can presume with maximum thermal load. Basic data can prove by air conditioning equipment system data analysis at existing building. There are poor and not reliable alternative presentation. In this paper, measured data after use H.V.A.C load calculation K-load program reply choosing standard building and variables simulation. And I founded peak load correlation graph and mode for several kinds of variable and contents of size. I wish that equipment designer is beaconed to produce optimum capacity at building as quantitative through this result.

A Study on Air and Gas System of Coal Fired Power Plant (석탄화력발전소의 공기 및 가스시스템 모델에 관한 연구)

  • Jung, Hwan-Joo;Kim, Tae-Hyun;Ryoo, Young-Jae;Chang, Young-Hak;Moon, Chae-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.283-285
    • /
    • 2002
  • Boiler combustion systems are large, non-linear systems with numerous interactions between its component parts. In the analysis of such complex systems. dynamic simulation is recognized as a powerful method of keeping track of the myriad of interactions. This paper shows and discusses the developed analysis model, such as the forced draft fan the primary air fan, the furnace and burner system, pulverizer, air preheater and induced draft fan, etc. in accordance with BMCR condition of boiler using the Modular Modeling System(MMS) software.

  • PDF

Dynamic Analysis of Air Circuit Breaker with Spring-Actuated Linkage (스프링구동 링크를 가진 기중 회로차단기의 동적 분석)

  • 안길영;권병희;오일성;윤영관;최종웅
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.812-815
    • /
    • 1997
  • A dynamic model of air circuit breaker with a spring-actuated linkage is derived, and its validation for analysis and design, particularly appropriateness for an analysis of high-speed motion behavior are checked through experiments. The dynamic model is developed through the modeling process based on ADAMS and Pro/Engineer. The simulation results of derived dynamic models for the rapid closing and opening operations are compared with actual responses using a high-speed camera and investigated to validate their usefulness.

  • PDF

The Characteristics of Airborne Noise Transfer Path Analysis Methods according to Path Models (경로 모델에 따른 공기기인 소음 전달 경로 분석법 특성 분석)

  • Byun, Jae-Hwan;Kim, Yoon-Jae;Kang, Yeon-June;Kang, Koo-Tae;Kwon, O-Jun;Hong, Jin-Chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.782-788
    • /
    • 2008
  • In this paper, a comparison about two representative Transfer Path Analysis(TPA) methods for air-borne noise based on, matrix inversion method and pressure transmissibility, are presented on the view point of crosstalk effect between sources. In order to assess accuracy of two methods according to path models between virtual airborne noise sources, experiments are made for two cases, weak and strong crosstalk effect condition, by using acrylic vehicle model. Based on this assessment, the paper presents a reasonable application criteria for TPA method according to the circumstances of air-borne noise sources.

  • PDF

Dynamic Modeling and Simulation of a Hybrid Heat Pump (하이브리드 열펌프 동적 모델링 및 시뮬레이션)

  • Shin, Younggy;Kim, Jae Hyun;Yoo, Byeong Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.7
    • /
    • pp.406-412
    • /
    • 2013
  • A hybrid heat pump is under development with the goal of utilizing 120% of primary energy resources. A plate heat exchanger is added between the compressor and air-cooled condenser of an ordinary heat pump to heat water. For successful operation of the heat pump, it is necessary to develop a control algorithm under various operating conditions. As a virtual test bed for that purpose, a dynamic model has been developed, to simulate its dynamic behavior. It was modeled in transient one-dimensions, with varying phase lengths considered. The model was implemented in Matlab and Simulink. Simulation results were effectively applied to design a control algorithm. They also provided physical insight into how to design and operate the system.

The Joint Frequency Function for Long-term Air Quality Prediction Models (장기 대기확산 모델용 안정도별 풍향·풍속 발생빈도 산정 기법)

  • Kim, Jeong-Soo;Choi, Doug-Il
    • Journal of Environmental Impact Assessment
    • /
    • v.5 no.1
    • /
    • pp.95-105
    • /
    • 1996
  • Meteorological Joint Frequency Function required indispensably in long-term air quality prediction models were discussed for practical application in Korea. The algorithm, proposed by Turner(l964), is processed with daily solar insolation and cloudiness and height basically using Pasquill's atmospheric stability classification method. In spite of its necessity and applicability, the computer program, called STAR(STability ARray), had some significant difficulties caused from the difference in meteorological data format between that of original U.S. version and Korean's. To cope with the problems, revised STAR program for Korean users were composed of followings; applicability in any site of Korea with regard to local solar angle modification; feasibility with both of data which observed by two classes of weather service centers; and examination on output format associated with prediction models which should be used.

  • PDF

Numerical Simulation of Ozone Concentration using the Local Wind Model in Pusan Coastal Area, Korea (부산연안역에서 국지풍모델을 이용한 오존농도의 수치모의)

  • Jeon, Byung-Il;kim, Yoo-Keun;Lee, Hwa-Woon
    • Journal of Environmental Science International
    • /
    • v.6 no.4
    • /
    • pp.335-350
    • /
    • 1997
  • Numerical simulations of photochemical air pollution (CBM: Carbon-Bond Mechanisms under a theoretical three-dimensional local wind system are carried to clarify the fundamental characteristics of the effects of local wind on photochemical air pollution. According to the AWS data of Pusan coastal area and KMA, the surface wind of Pusan during summertime showed a very remarkable land and sea breeze circulation. The ozone concentration distribution using local wind model showed that high ozone concentration zone near coastal area moved toward inland In the afternoon. This change implies a sea breeze Increases the ozone concentration, but a land breeze decreases it in Pusan coastal area.

  • PDF