• Title/Summary/Keyword: AIR 모델

Search Result 2,267, Processing Time 0.208 seconds

Ground Vibration Test for Korea Sounding Rocket - II PFM (과학로켓 2호(KSR-II) 준비행 모델의 지상 진동 시험)

  • 우성현;김홍배;문상무;이상설;문남진
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.546-551
    • /
    • 2001
  • Space Test Department at KARI(Korea Aerospace Research Institute) plans to carry out the GVT(Ground Vibration Test) for the KSR(Korea Sounding Rocket)-III FM(Flight Model) which is being developed by Space Technology R&D Division. KSR-III will be an intermediate to the launch vehicle capable of carrying satellites to their orbits. GVT offers very important information to predict the behavior of KSR in its operation, and to develop the flight control and aerodynamic analysis. For development of test facilities, testing and analysis methods which can be used for the future test, Space Test Department has performed the GVT with KSR-II PFM(Proto-Flight Model) at Satellite Integration & Test Center of KARl This paper discusses the procedures, techniques and the results of it. In this test, to simulate free-free condition, test object hung in the air by 4 bungee cords specially devised. The GVT was carried out using pure random excitation technique with MIMO(Multi-Input-Multi-Output) method with three electromagnetic shakers, and poly-reference parameter estimation was used to identify the modal parameters. As the result of the test, 11 mode shapes and modal parameters below 200㎐ were identified and compared with analytical results.

  • PDF

A Study on Reduction Method of Stack Effect at Stairwell of High-Rise Building (고층건물 피난계단에서의 연돌효과 저감방안 연구)

  • Kim, Jung-Yup;Shin, Hyun-Joon
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.14-20
    • /
    • 2011
  • As the height of the building increases, the stack effect in stairwell that is main facilities for evacuation becomes stronger. While the pressure rise in stairwell causes difficulties on opening the door for evacuation and has effect on smoke control system, reduction of stack effect will be necessary for providing more safe evacuation environment. The field experiments on pressure field in high-rise building are carried out to present reduction method of stack effect and the numerical analyses using network model are proceeded to design quantitatively the reduction method. As the air flow supplied from outside in lower stair and exhausted to outside in upper stair is formed in stairwell, the stack effect in stairwell is expected to be decreased.

Combustion Modeling of Nano/Micro Aluminum Particle Mixture (나노-마이크로 알루미늄 혼합 입자의 공기와의 연소 모델링)

  • Yoon, Shi-Kyung;Shin, Jun-Su;Sung, Hong-Gye
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.6
    • /
    • pp.15-25
    • /
    • 2011
  • One dimensional combustion modeling of aluminum combustion behavior is proposed. Combustion model is assumed that region consists as follows ; preheat, reaction, post reaction region. Flame speed as a function of particle size, equivalence ratio for unitary particles and fraction ratio of micro to nano particle size for binary particles were investigated for lean burn condition at 1 atm. Results were compared with experimental data. For unitary particles, flame speed increase as particle size decreases, but opposite trend with equivalence ratio. For binary particles, flame speed increases proportionally as nano particle fraction increases. For flame structure, separated or overlapping flames are observed, depending on the fraction of nano sized particles.

A Study of Dynamic Simulation of a Hybrid Absorption Chiller Utilizing Solar Power (태양열을 이용한 일이중 겸용 흡수식 냉온수기 동적성능 모사연구)

  • Shin, Young-Gy;Seo, Jung-A;Woo, Sung-Min;Kim, Hyo-Sang
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.967-972
    • /
    • 2009
  • A dynamic model has been developed to investigate the operability of a single and double-effect solar energy assisted parallel type absorption chiller. In the study, main components and fluid transport mechanism were modeled. And solar radiation and the solar collector also were also modeled along with its control design. The model was run for the single mode with solar energy supply only and the solar/gas driving double effect mode. From the simulation results, it was found that the present configuration of the chiller is not capable of regulating solution flow rates according to variable solar energy input. And the issues of the excessive circulation flowrate and the mismatch between available solar power and cooling load discourages the use of the single mode, but the dual use of gas and solar power is recommendable in view of controllability and enhanced COP.

  • PDF

Design to Reduce Structure-borne Noise in Outdoor Unit of Air Conditioner Using Structural Optimization with Frequency Constraints (고유진동수 제약식을 갖는 구조 최적화를 통한 에어컨 실외기의 구조기인소음 저감 설계)

  • 최상현;박남규;박윤식
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.179-184
    • /
    • 2001
  • 대부분의 제품 생산 시에는 시제품을 제작하여 이에 대한 성능 심사를 통해 미비한 부분을 보완하기 위한 재설계 작업과정을 필요로 한다. 설계 작업에 가장 중요한 부분인 특정 설계 변수에 대한 민감도의 파악은 설계 작업의 핵심적인 역할을 하고 있다. 대개의 경우 진동설계를 위한 설계변수로 구조물의 단위면적, 길이, 재료의 성질과 같은 물리적인 변수를 많이 활용하고 있으며 이러한 변수들에 대한 민감도 해석 기법들은 이미 많은 연구를 통해 실용화되고 있다. 그러나 이러한 변수만으로는 주어진 조건을 만족하도록 설계하기가 어려운 경우가 있다. 이런 경우는 부가구조물을 첨가하여 저진동 설계조건을 만족하는 구조물을 제작하는 것이 보편적이다. 한편, 구조물의 최적화 과정에서 고유진동수를 고려해야 하는 경우가 많다. 저주파 영역의 문제에서는 첫번째 고유진동수가 구조물의 진동량에 관계되는 중요한 요인이 되고, 또한 공진에 의한 문제가 발생했을 경우에는 고유진동수를 옮겨서 공진을 회피할 수 있기 때문이다. 본 연구에서는 에어컨 실외기의 진동을 저감하고 그로 인한 구조기인 소음을 저감하기 위하여 음압 레벨을 바탕으로 정한 관심 주파수 영역에 고유진동수가 존재하지 않도록 부가구조물을 최적화하였다. 최적화에 필요한 민감도는 신뢰성 있는 유한요소 모델을 구성하는 것이 쉽지 않으므로 실험으로 구한 주파수 응답함수를 이용하였다.

  • PDF

Numerical Study of the Circulation in the Japan Sea -I. Case of Closed Basin (동해의 해수 순환에 대한 Numerical Modelling 연구 -I. 폐쇄해역으로 가정한 경우)

  • Kim, Yeong Eui;Chung, Jong Yul
    • 한국해양학회지
    • /
    • v.24 no.2
    • /
    • pp.96-108
    • /
    • 1989
  • Applying the numerical scheme developed by Semtner (1974), we investigate the circulation system in the Japan Sea in response to the air-sea interaction and the wind. In spite of blocking straits, resulting surface circulation pattern is similar to the schematic surface current chart introduced by Uda(1934) and Naganuma (1972); the northward flow along the Korean coast and the anticlockwise gyre in the northeastern part of the Japan Sea. Also the southward current flows along the Korean coast at depth of 100-200 m as similar to the North Korean Cold Current suggested by Kim and Kim (1983). And the sinking phenomenon of relatively saline water in the northeastern part of the Japan Sea is similar to the formation of the Japan Sea Proper Water.

  • PDF

Flame Extinguishing Concentrations and Flue Gas Compositions of n-Heptane by Mixed Inert Gas Agents (불활성 가스계 혼합소화약제의 n-Heptane 불꽃소화농도 및 배가스 조성)

  • 김재덕;김영래;홍승태;이성철
    • Fire Science and Engineering
    • /
    • v.16 no.3
    • /
    • pp.77-83
    • /
    • 2002
  • We measured flame extinguishing concentration and flue gas composition in the n-heptane fuel cup-burner system using inert gas agents such as nitrogen, argon, carbon dioxide and their mixtures. The flame extinguishing concentration of binary gaseous mixture was well predicted by model which contains the flame extinguishing concentration and composition of pure components. The higher average specific gravity of the mixed inert gas agents, the more excellent flame extinguishing performance. And the structure of enclosed space also affects the fire extinguishing. The composition of carbon dioxide in the flue gas was decreased with increasing extinguishing agent used. Nitrogen monoxide production is not related with increasing nitrogen, but increased at rapid mass flow rate of air in the cup-burner.

A Physics-Based Modelling of Multiphase Fluid Phenomena (물리적 모델에 기반한 다상 유체 현상 애니메이션)

  • Song, Oh-Young;Shin, Hyun-Cheol;Ko, Hyeong-Seok
    • Journal of the Korea Computer Graphics Society
    • /
    • v.10 no.4
    • /
    • pp.13-21
    • /
    • 2004
  • This paper presents a physically based technique for simulating complex multiphase fluids. This work is motivated by the "stable fluids" method developed by Stam to handle gaseous fluids. We extend this technique to water, which calls for the development of methods for modeling multiphase fluids and suppressing dissipation. We construct a multiphase fluid formulation by combining the Navier-Stokes equations with the level set method. By adopting constrained interpolation profile (CIP)-based advection, we reduce the numerical dissipation and diffusion significantly. We further reduce the dissipation by converting potential1y dissipative cel1s into droplets or bubbles that undergo Lagrangian motion. Due to the multiphase formulation, the proposed method properly simulates the interaction of water with surrounding air, instead of simulating water in a void space. Moreover, the introduction of the non-dissipative technique means that, in contrast to previous methods, the simulated water does not unnecessarily lose mass and its motion is not damped to an unphysical extent. Experiments showed that the proposed method is stable and runs fast. It is demonstrated that two-dimensional simulation runs in real-time.

  • PDF

A Study on the Atmospheric Environment and Simulations of Wind Field using MUKLIMO at the KNU Campus (경북대 캠퍼스 내 대기환경 및 미규모 모델(MUKLIMO)을 이용한 바람장 모의 연구)

  • Min Kyung-Duck;Yoon Ji-Won;Ahn Kwang-Deuk
    • Journal of Environmental Science International
    • /
    • v.14 no.3
    • /
    • pp.311-325
    • /
    • 2005
  • Elements of atmospheric environment, temperature, humidity and wind, at the compus of KNU(Kyungpook National University) were investigated by the observations. The observed data were compared with those of DWS (Daegu Weather Station). The simulations of wind field and dispersions of polluted gases were conducted by MUKLIMO under the various conditions. The results show that the atmospheric environment of KNU are suitable but the campus does not play role as a heat sink in the city. The simulations of wind field show the air flows and wind channels in the campus clearly. The exhausted gases by motor vehicles on the northside street of campus affect very much to the campus with $NW(300^{\circ})$ wind. The running cars in the campus are also pollute much on the campus with the various wind directions. The characteristics of environmental conditions, various meteorological fields, wind channels, and dispersion of exhausted gases at the campus of KNU were understood quantitatively in the study.

Optimal Design of Axial Type Brushless DC Motor Using 3-D FEM (3차원 유한요소법을 이용한 축방향 자속형 브러시리스 DC 전동기 최적 설계)

  • Hong, Sun-Ki
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.143-147
    • /
    • 2005
  • In this paper, an axial type brushless DC motor which has double rotors using rare-earth magnet pieces is designed. This kind of motor has shorter axial length and is easier to assemble than the radial type motors. To get enough torque, NdFeB magnet is used and for the cost of production, the magnets are segmented to rectangle or disk shape. To design this motor, a equivalent circuit is adopted and the air-gap density is calculated using 3D finite element method to get exact parameters. The design variables are optimized with genetic algorithm. From the results of the simulations, the reference of the axial type BLDC motors can be obtained.