• Title/Summary/Keyword: AIR 모델

Search Result 2,267, Processing Time 0.033 seconds

An experimental study on the ignition of dusts behind reflected shock waves (고체미립자의 반사압축파에 의한 점화에 관한 실험적 연구)

  • 백승옥
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.1
    • /
    • pp.118-123
    • /
    • 1987
  • In relation to the dust detonatians which have imposed severe damages on the industry, the ignitability of various dusts has been investigated on a horizontal shock tube in this study. By using a newly designed air injector, very well-distributed clouds could be obtained. The proper reflected shock conditions have been generated by placing a reflector 1.5cm behind the air injector, which reflected the incident shock wave. The incident shock waves in the range of Mach number 2.8-3.3 created the postreflected shock temperature of 1200-1600K. Experimentally the ignition delay was defined as the time interval between the arrival of a reflected shock wave at dusts and the detection of visible light. Measured ignition delays of dusts investigated were located lower than 1msec under the above conditions. These values are one-order higher than those in the incident shock wave condition. In this type of ignitiion process the following three processes are considered to play important roles; heating of a particle, generation of volatile gas by endothermic devolatilization process, and its diffusion from the particle surface and the formation of stoichiometric mixture with oxidizer.

Bandwidth Enhancement of Equilateral Triangular Microstrip Patch Antenna using Reactance Variation (리액턴스의 변화를 이용한 정삼각형 마이크로스트립 패치 안테나의 대역폭 개선)

  • Lee, Won-Hui;Lee, Jae-Wook;Jeon, Seung-Gil;Choi, Hong-Ju;Hur, Jung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.6
    • /
    • pp.638-647
    • /
    • 2003
  • Triangular patches have been studied, both theoretically and experimentally. We feund that provided radiation characteristics similar to those of rectangular patches, but with smaller size. In this paper, we designed an equilateral triangular microstrip patch antenna using cavity model analysis. Then, in order to improve narrow bandwidth, we add capacitive gap and air gap. Capacitive gap is located with square shape beside feeding point on the patch, and air gap is inserted between substrate dielectric and ground plane to adjust probe inductance. The analysis of characteristics and effects of each component was performed by commercial simulation tool, Ensemble 5.0. Throughout the simulation and experiment, we found the possibility of bandwidth enhancement in triangular microstrip antenna.

Source Identification of Ambient PM-10 Using the PMF Model (PMF 모델을 이용한 대기 중 PM-10 오염원의 확인)

  • 황인조;김동술
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.6
    • /
    • pp.701-717
    • /
    • 2003
  • The objective of this study was to extensively estimate the air quality trends of the study area by surveying con-centration trends in months or seasons, after analyzing the mass concentration of PM-10 samples and the inorganic lements, ion, and total carbon in PM-10. Also, the study introduced to apply the PMF (Positive Matrix Factoriza-tion) model that is useful when absence of the source profile. Thus the model was thought to be suitable in Korea that often has few information about pollution sources. After obtaining results from the PMF modeling, the existing sources at the study area were qualitatively identified The PM-10 particles collected on quartz fiber filters by a PM-10 high-vol air sampler for 3 years (Mar. 1999∼Dec.2001) in Kyung Hee University. The 25 chemical species (Al, Mn, Ti, V, Cr, Fe, Ni, Cu, Zn, As, Se, Cd, Ba, Ce, Pb, Si, N $a^{#}$, N $H_4$$^{+}$, $K^{+}$, $Mg^{2+}$, $Ca^{2+}$, C $l^{[-10]}$ , N $O_3$$^{[-10]}$ , S $O_4$$^{2-}$, TC) were analyzed by ICP-AES, IC, and EA after executing proper pre - treatments of each sample filter. The PMF model was intensively applied to estimate the quantitative contribution of air pollution sources based on the chemical information (128 samples and 25 chemical species). Through a case study of the PMF modeling for the PM-10 aerosols. the total of 11 factors were determined. The multiple linear regression analysis between the observed PM-10 mass concentration and the estimated G matrix had been performed following the FPEAK test. Finally the regression analysis provided source profiles (scaled F matrix). So, 11 sources were qualitatively identified, such as secondary aerosol related source, soil related source, waste incineration source, field burning source, fossil fuel combustion source, industry related source, motor vehicle source, oil/coal combustion source, non-ferrous metal source, and aged sea- salt source, respectively.ively.y.

Predictive Model of Micro-Environment in a Naturally Ventilated Greenhouse for a Model-Based Control Approach (자연 환기식 온실의 모델 기반 환기 제어를 위한 미기상 환경 예측 모형)

  • Hong, Se-Woon;Lee, In-Bok
    • Journal of Bio-Environment Control
    • /
    • v.23 no.3
    • /
    • pp.181-191
    • /
    • 2014
  • Modern commercial greenhouse requires the use of advanced climate control system to improve crop production and to reduce energy consumption. As an alternative to classical sensor-based control method, this paper introduces a model-based control method that consists of two models: the predictive model and the evaluation model. As a first step, this paper presents straightforward models to predict the effect of natural ventilation in a greenhouse according to meteorological factors, such as outdoor air temperature, soil temperature, solar radiation and mean wind speed, and structural factor, opening rate of roof ventilators. A multiple regression analysis was conducted to develop the predictive models on the basis of data obtained by computational fluid dynamics (CFD) simulations. The output of the models are air temperature drops due to ventilation at 9 sub-volumes in the greenhouse and individual volumetric ventilation rate through 6 roof ventilators, and showed a good agreement with the CFD-computed results. The resulting predictive models have an advantage of ensuring quick and reasonable predictions and thereby can be used as a part of a real-time model-based control system for a naturally ventilated greenhouse to predict the implications of alternative control operation.

PERFORMANCE ASSESSMENT OF THE RANS TURBULENCE MODELS IN PREDICTION OF AERODYNAMIC NOISE FOR AIR-CONDITIONER INDOOR UNIT (에어컨 실내기의 공력소음 예측을 위한 RANS 난류모델의 성능 평가)

  • Min, Y.H.;Kang, S.;Hur, N.;Lee, C.;Park, J.
    • Journal of computational fluids engineering
    • /
    • v.17 no.4
    • /
    • pp.81-86
    • /
    • 2012
  • The objective of the present study is to investigate the effects of various turbulence models on the aerodynamic noise of an air-conditioner (AC) indoor unit. The results from URANS (unsteady Reynolds-averaged Navier-Stokes) simulations with the standard k-$\varepsilon$, k-$\omega$ shear stress transport (SST) and Spalart-Allmaras (S-A) turbulence models were analyzed and compared with the noise data from the experiments. The frequency spectra of the far-field acoustic pressure were computed using the Farrasat equation derived from the Ffowcs Williams-Hawkings (FW-H) equation based on the acoustic analogy model. Two fixed fan casings and the rotating cross-flow fan were used as the source surfaces of the dipole noise in the Farrasat equation. The result with the standard k-$\epsilon$ model showed a much better agreement with the experimental data compared to the k-w SST and S-A models. The differences in the pressure spectra from the different turbulence models were discussed based on the instantaneous vorticity fields. It was found that the over-estimated power spectra with the k-w SST and S-A models are related to the emphasized small-scale vortices produced with these models.

A Study on Semi Quantitative Risk Analysis for Air Separation Unit using a GRA(Generic Risk Analysis) Method (GRA(Generic Risk Analysis) 기법을 이용한 공기분리시설에 대한 준 정량적 위험성 평가에 관한 연구)

  • Shin, Jung-Soo;Byun, Hun-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.1
    • /
    • pp.56-66
    • /
    • 2013
  • The gas production plants supply the inert gas to production plants for maintaining safe operation and also supply combustible, flammable, explosive and toxic gases as functions of basic materials needed for producing chemical goods. In addition, gas plants need to be safe and reliable operation because they are operated under high temperature, high pressure, cryogenic and catalytic reactions. As these plants have a complex process in operation, there has been a risk that major industrial accidents such as a fire, explosion and toxic gas released, also risks of asphyxiations by inert gases and burns caused by high temperature and cryogenic substances. This study is to carry out the semi quantitative risk assesment method which is the generic risk analysis (GRA). This method is applied to air separation unit(ASU) to identify its initial risk, safety barriers, residual risk and elements important for safety(EIS). The result of this study, suggested the management tools and procedures of implementation for EIS management.

Drying Characteristics and Drying Model of Red Pepper (고추의 건조특성(乾燥特性)과 건조모델에 관(關)한 연구(硏究))

  • Cho, Y.J.;Koh, H.K.
    • Journal of Biosystems Engineering
    • /
    • v.11 no.1
    • /
    • pp.52-63
    • /
    • 1986
  • This study was performed to find out drying characteristics and develop drying model for the design of an efficient dryer or drying system of red peper. The basic model which describes drying phenomenon of red pepper was firstly established, and drying tests were conducted at 14-different drying conditions. In this test, the effects of drying air temperature and relative humidity on the rate of drying were undertaken. Finally, a new drying model based on these experimental results was developed to describe the drying characteristics of red pepper. The results from this study may be summarized as follows. 1. Drying constant of the basic model established from Lewis' experimental model and diffusion equation was theoretically deduced as a function of moisture content and inner-temperature of red pepper. 2. From the results of drying tests, drying air temperature was found to have the greatest effect on the rate of drying. However, the effect of temperature was small for the condition of high relative humidity, and for low temperature, the effect of relative humidity was found to be large even though the range of relative humidity was low. 3. Modified Henderson equation was found to be better than Chung equation as the EMC model for the estimation of the equilibrium moisture content of red Pepper. 4. Constant-rate drying period did not exist in the red pepper drying test. And falling-rate drying period was divided into three distinct phases. Drying rate was dependent on the moisture content, the inner-temperature of red pepper and the change of physical property due to drying. 5. Drying constant increased with decrease of free moisture content, but it decreased at the end of the drying period. Also, drying constant was dependent on the drying air temperature and relative humidity. 6. The new drying model developed in this study was found to be most suitable in describing the drying characteristics of red pepper. Therefore, it may be concluded that drying time could be accurately estimated by the new drying model.

  • PDF

A Numerical Study of the 2-D Cold Flow for a Qubec City Stoker Incinerator (큐벡시 스토커 소각로 2차원 비반응 유동장 수치해석)

  • 박지영;송은영;장동순
    • Journal of Energy Engineering
    • /
    • v.2 no.3
    • /
    • pp.268-275
    • /
    • 1993
  • A series of parametric investigations are performed in order to resolve the flow characteristic of a Quebec city stoker incinerator. The parameters considered in this study are five internal configurations of the Quebec city stoker itself and its modified ones, primary air velocity, the injection velocity and angle of the secondary air, and the reduction of the stoker exit area. A control-volume based finite-difference method by Patankar together with the power-law scheme is employed for discretization. The resolution of the pressure-velocity coupling is made by the use of SIMPLEC algorithm. The standard, two equation, k-$\varepsilon$ model is incorporated for the closure of turbulence. The size of recirculation region, turbulent viscosity, the mass fraction of the secondary air and pressure drop are calculated in order to analyze the characteristics of flow field. The results are physically acceptable and discussed in detail. The flow field of the Quebec city stoker shows the strong recirculation zone together with the high turbulence intensity over the upper part of the incinerator.

  • PDF

A Study on the Predictability of the Air Pollution Dispersion Model Composed of the Turbulent Parameters (난류특성을 이용한 대기오염확산모델의 예측능에 관한 연구)

  • Park, Ki-Hark;Yoon, Soon-Chang
    • Journal of Environmental Impact Assessment
    • /
    • v.10 no.2
    • /
    • pp.123-133
    • /
    • 2001
  • Gaussian dispersion model is the most widely used tool for the ground level air pollution simulation. Though in spite of the convenience there are important problems on the Pasquill- Gifford' stability classification scheme which was used to define the turbulent state of the atmosphere or to describe the dispersion capabilities of the atmosphere which was each covers a broad range of stability conditions, and that they were very site specific, and the vertical dispersion calculation formula on the case of the unstable atmospheric condition. This paper was carried out to revise the Gaussian dispension model for the purposed of increase the modeling performance and propose the revised model, which was composed of the turbulent characteristics in the unstable atmospheric conditions. The proposed models in this study were composed of the profile method, Monin-Obukhove length, the probability density function model and the lateral dispersion function which was composed of the turbulent parameters, $u_*$(friction velocity), $w_*$(convective velocity scale), $T_L$(lagrangian time scale) for the model specific. There were very good performance results compare with the tracer experiment result on the case of the short distance (<1415m) from the source, but increase the simulation error(%) to stand off the source in the all models. In conclusion, the revised Gaussian dispersion model using the turbulent characteristics may be a good contribution for the development of the air pollution simulation model.

  • PDF

Noise Priority Route Generation and Noise Analysis for the Operation of Urban Air Mobility Considering Population Distribution (도심항공 모빌리티 운용을 위한 인구분포를 고려한 소음 우선 경로 생성 및 소음 분석)

  • So, Min-Jun;Hwang, Ho-Yon
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.5
    • /
    • pp.348-357
    • /
    • 2020
  • An important challenge in commercialization of eVTOL PAV is to reduce noise for urban air mobility (UAM) operation. Therefore, in this paper, noise priority routes were created to minimize the number of people affected by noise using aviation environmental design tool (AEDT) software and population distribution data for administrative districts, and noise analyses during operation were performed. Also, it was analyzed how much noise exposure could be reduced compared to the number of people affected by noise in the shortest route. Considering that the eVTOL PAV developers do not provide data, the analysis was conducted using a helicopter model. As a result, it was shown that the noise priority route that minimized the amount of noise exposure was more efficient than other routes.