• 제목/요약/키워드: AES resin

검색결과 18건 처리시간 0.023초

Separation of Goid, Palladium and Platinum in Chromite by Anion Exchange Chromatography for Inductively Coupled Plasma Atomic Emission Spectrometric Analysis

  • 최광순;이창현;박영재;조기수;김원호
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권8호
    • /
    • pp.801-806
    • /
    • 2001
  • A study has been carried out on the separation of gold, iridium, palladium, rhodium, ruthenium and platinum in chromite samples and their quantitative determination using inductively coupled plasma atomic emission spectrometry (ICP-AES). The dissolution condition of the minerals by fusion with sodium peroxide was optimized and chromatographic elution behaviour of the rare metals was investigated by anion exchange chromatography. Spectral interference of chromium, a matrix of the minerals, was investigated on determination of gold. Chromium interfered on determination of gold at the concentration of 500 mg/L and higher. Gold plus trace amounts of iridium, palladium, rhodium and ruthenium, which must be preconcentrated before ICP-AES was separated by anion exchange chromatography after reducing Cr(Ⅵ) to Cr(III) by H2O2. AuCl4- retained on the resin column was selectively eluted with acetone- HNO3-H2O as an eluent. In addition, iridium, palladium, rhodium and ruthenium remaining on the resin column were eluted as a group with concentrated HCl. However, platinum was eluted with concentrated HNO3. The recovery yield of gold with acetone-HNO3-H2O was 100.7 ${\pm}2.0%$, and the yields of palladium and platinum with concentrated HCl and HNO3 were 96.1 ${\pm}1.8%$ and 96.6 ${\pm}1.3%$, respectively. The contents of gold and platinum in a Mongolian chromite sample were 32.6 ${\pm}$ 2.2 ${\mu}g$/g and 1.6 $\pm$ 0.14 ${\mu}g$/g, respectively. Palladium was not detected.

AES 그라프트 공중합에서 EPDM 고무의 디엔 함량 및 점도에 따른 영향 (The Effect of the Viscosity and Diene Contents of EPDM for Graft Copolymerization of AES)

  • 이슬;이병도;김중인;송요순
    • 공업화학
    • /
    • 제20권3호
    • /
    • pp.339-345
    • /
    • 2009
  • Acrylonitrile과 EPDM 고무 및 styrene을 원료로 AES 수지의 공중합을 개시제 함량, EPDM의 디엔 함량 및 점도가 다른 고무, 용매의 농도 및 종류를 달리하여 조사하였다. 개시제의 함량이 높을수록 전환율이 증가하였고, 분자량 및 평균 고무입자크기(RPS, Rubber Particle Size)는 감소하였다. 그라프트 비(GR, Graft Ratio)는 낮은 개시제 농도에서는 개시제 농도가 증가함에 따라 증가하여 최대값을 보이고 개시제 농도가 계속 증가하면 감소하는 경향을 보였다. 용매의 양이 감소할수록 전환율과 GR은 증가하였으나, 고무입자크기는 감소하였다. 단일 용매 중에는 톨루엔이 가장 좋은 반응 활성을 보였고, 에틸벤젠과 톨루엔을 섞으면 톨루엔만 사용하는 것보다 더 좋은 활성을 보였다. EPDM의 점도가 증가하면 고무입자크기가 커졌으며, 디엔 함량이 증가하면 GR과 SAN이 내포된 고무입자가 증가하였다.

AG® 50W-X8 양이온교환수지를 이용한 희토류원소의 분리와 분석에 관한 연구 (A study on the separation and determination of the rare earth Elements by the AG® 50W-X8 cation exchange resin)

  • 이정숙;최범석
    • 분석과학
    • /
    • 제21권4호
    • /
    • pp.272-278
    • /
    • 2008
  • $AG^{(R)}$ 50W-X8 양이온교환수지를 이용하여 14종의 희토류원소와 Y를분리하고, 유도결합플라스마 원자방출분광법(ICP-AES)으로 분석하는 방법에 대해 연구하였다. 수지에 대한 희토류원소의 이온교환용량은 매우 커 pH 1~6 범위와 0.3~1.0mL/min의 흐름속도에서 희토류원소는 모두 정량적으로 이온교환 되었다. 희토류원소의 돌파점 용량 곡선은 경희토류원소(Cerium 그릅)의 이온교환능력이 중희토류원소(Yttrium 그릅) 보다 큰 것을 보여주었다. 100mg의 이온교환수지에 각각 $200{\mu}g$의 희토류원소들이 이온교환 되어있을 때 대부분의 중희토류원소는 2.0M의 질산 10 mL로, 경희토류원소는 30mL로 정량적으로 탈착시킬 수 있었다. 본 방법으로 모나자이트 중에 희토류원소를 분석하였다. 모나자이트 중에 공존하는 Ti, Mn, Mg, Ca 등의 원소는 상대적으로 희토류원소 보다 이온교환 능력이 낮아, 매트릭스 원소로 부터 희토류원소의 분리가 가능하였다. 그러나 본 방법에서 분석 결과의 상대표준편차는 1~5%로 향상되지 않았다.

시멘트 고화체 중 Sr-90 분석을 위한 시료 전처리

  • 표형열;김영복;최광순;한선호;송규석
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2009년도 학술논문요약집
    • /
    • pp.131-132
    • /
    • 2009
  • 시멘트 고화체 중의 Sr-90 분석을 위한 시료 전처리 방법을 실험을 통하여 확립하였다. 시멘트 고화체 중의 Sr-90 과 같은 베타방출 핵종을 분석하기 위해서는 고화체 시료를 건조, 분쇄, 산처리, Sr-90 분리 및 LSC 를 이용한 Sr-90의 방사능 측정을 해야 한다. 이를 위하여 인수 고화체 시료를 전 처리 하기 전, SRM 1887a portland cement 를 사용하여 여러 산 처리 방법을 통하여 각 원소들의 회수율을 알아보았다. SRM 시료를 통하여 얻은 조건을 참조하여 실제 고화체 시료 5g 씩 3회의 7개 시료들을 전 처리하여 ICP-AES 를 통하여 각 원소들의 회수율을 비교하였다. 또한, 전처리 후 Sr 분리에 Sr-resin (Eichrom)를 이용하기 위해서는 Sr-resin 사용 시 많은 영향을 주는 칼슘의 량을 미리 알아야 한다, 이를 위하여 시멘트 고화체 중 50% 가까이 함유되어 있는 칼슘 량을 반 정량적으로 알아내기 위한 방법을 확립하였다.

  • PDF

Pull-out 시험 후의 표면분석 : 갈색산화물 (Analyses of Fracture Surfaces after Pull-out Test: Brown Oxide)

  • Lee, H.Y.;Kim, S.R.
    • 한국표면공학회지
    • /
    • 제34권2호
    • /
    • pp.142-150
    • /
    • 2001
  • Due to naturally formed copper oxides, the adhesion strength between copper and epoxy resin is often very poor. To improve the adhesion strength between copper and epoxy resin, Cu-based leadframe sheets were oxidized in a brown-oxide forming solution. Then the effect of brown-oxide formation on the adhesion strength of leadframe to epoxy molding compound (EMC) was studied using pull-out specimens. After the pull-out test, fracture surfaces were analyzed using SEM, AES and EDS to determine failure path. The results showed that the failure path lay over inside the CuO and inside the EMC irrespective of the pull strength.

  • PDF

옻나무 경사핑거접합재의 휨강도와 AE 특성 (The Bending Strength and Acoustic Emissions Properties of Sloped Finger-Jointed Rhus Verniciflua)

  • 변희섭;김사익
    • 한국가구학회지
    • /
    • 제10권2호
    • /
    • pp.73-78
    • /
    • 1999
  • This paper describes the relationship between the bending strength properties of sloped finger-jointed woods and the acoustic emissions(AEs) generated during the test. Rhus verniciflua pieces were cut in sloped-finger types and glued with three kinds of adhesives(polyvinyl acetate, polyvinyl-acryl acetate and oilic urethane resin). The slope ratios of finger joints were 0, 1.0, 1.5, and 2.0. The AE cumulative event count and cumulative count were measured during the bending test. The results were as follows: The lower the bending strength(load) was, the generation time of AE event count got and the higher the increasing rate of AE event count became in the sloped finger-jointed specimens bonded with polyvinyl acetate, polyvinyl-acryl acetate oilic urethane resin adhesives. Therefore, the slope from load-AE cumulative event count was very steep. The patterns of AE event count and count were very similar. The relationship between the MOR and the AE parameter from load and AE cumulatve event count in the early stage of the sloped finger-jointed specimens bonded with polyvinyl acetate, polyvinyl-acryl and oilic urethane resin adhesives was much greater than that between the MOE and the MOR. Therefore, the AE signals obtained during bending test are useful for estimating the strength of sloped finger-jointed Rhus verniciflua specimens.

  • PDF

양.음이온교환 크로마토그래피와 유도결합플라스마 원자방출분광법을 이용한 모의 사용후핵연료 중 핵분열생성물 분석 (Determination of Fission Products in Simulated Nuclear Spent Fuels by Cation.Anion Exchange Chromatography and Inductively Coupled Plasma Atomic Emission Spectrometry)

  • 최광순;손세철;표형렬;서무열;김도양;박양순;지광용
    • 분석과학
    • /
    • 제13권4호
    • /
    • pp.446-452
    • /
    • 2000
  • 질산에 잘 녹지 않는 백금족 원소를 포함하고 있는 모의 사용후핵연료(SIMfUEL)를 고압산분해 방법으로 녹였다. 핵분열생성물 원소들은 우라늄과 분리한 다음 유도결합플라스마 원자방출분광법 (ICP-AES)으로 분석하였다. 핵분열생성물 원소들의 피크가 우라늄 스펙트럼으로부터 분광학적 간섭을 받으므로 Mo, Pd, Rh 및 Ru은 양이온교환수지로 Ba, Ce, La, Nd, Rh, Sr, Y 및 Zr는 음이온교환수지로 우라늄과 원소들을 군분리하였다. 사용후핵연료의 조성과 비슷한 모의 핵연료용액을 만들어 양이온 교환수지로 분리한 다음 측정한 회수율은 99-103%이고, 음이온교환수지로 분리하고 측정한 회수율은 이트륨을 제외하고 96.5-107%이었다. 이 방법을 금속원소의 농도가 수백에서 수천 ppm 존재하는 SIMFUEL에 적용하여 측정한 상대표준편차는 1.3-6.7%이었다.

  • PDF

Comparative Analysis of the Physical and Biochemical Properties of Light-cure Resin-modified Pulp Capping Materials

  • Tae Gyeom Kim;Jongsoo Kim;Joonhaeng Lee;Jisun Shin;Mi Ran Han;Jongbin Kim;Yujin Kim;Jae Hee Park
    • 대한소아치과학회지
    • /
    • 제51권2호
    • /
    • pp.149-164
    • /
    • 2024
  • This study compared the solubility, water absorption, dimensional stability, release of various ions (hydroxyl, calcium, sulfur, strontium, and silicon), and cytotoxicity of light-cured resin-modified pulp-capping materials. Resin-modified calcium hydroxide (Ultra-blendTM plus, UBP), light-cured resin-modified calcium silicate (TheraCal LCTM, TLC), and dual-cure resin-modified calcium silicate (TheraCal PTTM, TPT) were used. Each material was polymerized; solubility, 24-hour water absorption, and 30- day dimensional stability experiments were conducted to test its physical properties. Solubility was assessed according to the ISO 6876 standard, and 24 hours of water absorption, 30 days of dimensional stability were assessed by referring to the previous protocol respectively. Eluates at 3 and 24 hours and on 7, 14, and 28 days were analyzed according to the ISO 10993-12 standard. And the pH, Ion-releasing ability, cell proliferation rate, and cell viability were assessed using the eluates to evaluate biochemical characteristics. pH was measured with a pH meter and Ion-releasing ability was assessed using inductively coupled plasma atomic emission spectrometry (ICP-AES). Cell proliferation rate and cell viability were assessed using human dental pulp cells (hDPCs). The former was assessed by an absorbance assay using the CCK-8 solution, and the latter was assessed by Live and Dead staining. TPT exhibited lower solubility and water absorption than TLC. UBP and TPT demonstrated higher stability than TLC. The release of sulfur, strontium, calcium, and hydroxyl ions was higher for TLC and TPT than for UBP. The 28-day release of hydroxyl and silicon ions was similar for TLC and TPT. TLC alone exhibited a lower cell proliferation rate compared to the control group at a dilution ratio of 1 : 2 in cell proliferation and dead cells from Live and Dead assay evaluation. Thus, when using light-cure resin-modified pulp-capping materials, calcium silicate-based materials can be considered alternatives to calcium hydroxide-based materials. Moreover, when comparing physical and biochemical properties, TPT could be prioritized over TLC as the first choice.

중금속이온 흡착분리를 위한 킬레이트수지의 합성과 특성에 관한 연구 : 1. (A Study on the Synthesis and Characterization of Chelate Resin for Removal of Heavy Metal Ions: 1.)

  • 신대윤;육경창;이내택
    • 한국환경보건학회지
    • /
    • 제18권2호
    • /
    • pp.106-116
    • /
    • 1992
  • In order to examine the influences of diluent, DVB, and ligand content, in the adsorption velocities and capacities of chelating resins to heaw metal ions, the chelating resins containing the PO$_3$H, amide, and PO$_3$H+amide were prepared from AN-STR-DVB copolymer. The adsorption capacities of chelating resins were measured by ICP-AES. The major results of the studies are as follows: The optimized compositions of the chelating resins having the highest adsorptivity for the heavy metal ions were found to be DVB=7 wt%, toluene= 100 vol%. The adsorption rate of the chelating resins to the heaw metal ions was PO$_3$H > PO$_3$H+Amide > Amide in order.

  • PDF

유도결합플라스마 원자방출분광법을 이용한 모의 사용후핵연료 중 몰리브덴 분석 (Direct Determination of Molybdenum in Simulated Nuclear Spent Fuels by Inductively Coupled Plasma Atomic Emission Spectrometry)

  • 최광순;이창헌;박순달;박양순;조기수
    • 분석과학
    • /
    • 제13권3호
    • /
    • pp.291-296
    • /
    • 2000
  • 사용후핵연료와 조성이 비슷한 모의 사용후핵연료를 고압 산분해법으로 용해시킨 후 우라늄 매질로부터 몰리브덴을 분리하지 않고 유도결합플라스마 원자방출분광기(ICP-AES)로 바로 정량할 수 있는 분석조건을 검토하였다. 몰리브덴 분석에 미치는 우라늄의 분광학적 간섭 정도를 각각의 스펙트럼으로부터 비교, 평가한 결과 202.030과 203.844 nm의 파장이 분석선으로서 가장 적합하였으며, 보다 정확하고 정밀한 분석 결과를 얻기 위하여 표준물 첨가법을 적용하였다. 우라늄 매질로부터 몰리브덴을 양이온 교환수지(Bio-Rad AG 50W-X8)로 분리한 다음 ICP-AES로 분석한 결과와 직접 분석한 결과를 비교한 결과, 상대편차는 5% 범위 내에서 잘 일치하는 결과를 얻었다. 따라서 본 방법은 모의 사용후핵연료 용해용액 내에 함유되어 있는 몰리브덴을 바로 분석할 수 있을 뿐만 아니라 몰리브덴의 함량이 수 퍼센트인 우라늄-몰리브덴 합금중 몰리브덴 정량에도 적용할 수 있었다.

  • PDF