• Title/Summary/Keyword: AEC Appropriate Technology

Search Result 5, Processing Time 0.017 seconds

A Study on the Using of Automatic Exposure Control in the Chest Radiography (흉부 방사선검사에서 자동노출제어 사용에 관한 연구)

  • Choi, Sung-Sik;Lim, Cheong-Hwan;Jung, Sung-Hoon
    • Journal of radiological science and technology
    • /
    • v.42 no.1
    • /
    • pp.19-24
    • /
    • 2019
  • For general radiological examinations, even in the same area and the same test, the test conditions must be set differently according to the patient. However, since it is impossible to consider the body shape and conditions of patients every time in medical institutions where various patients visit, the tests are conducted by setting the AEC which automatically sets the test conditions. AEC is most commonly used in chest radiography. Therefore, the purpose of this study is to propose the improvement plans for using AEC by measuring the exposure dose and evaluating the image quality according to whether the AEC is used or not, and to provide basic data for AEC research. In the present study, images were acquired while varying tube voltage and test distance according to the use of AEC in chest radiography. The radiation dose was measured by placing the dosimeter in front of the chest phantom, and the CNR and SNR of acquired images were analyzed using Image J. The t-test was conducted for the statistical analysis and the significance was determined at the level of 95%(p<.05). As a result of this study, in the inspection distance (100cm, 140cm, 180cm) according to the use of AEC, high doses were observed when the AEC was used and there was statistically significant difference(p<.05). In the t-test to determine the difference between CNR and SNR depending on whether AEC was used or not, there was no significant difference according to the use of AEC(p>.05). Therefore, when performing chest radiography, if the radiologist establishes the appropriate examination conditions and conducts the examination by not just relying solely on AEC, it may be possible to reduce unnecessary radiation exposure to the patient.

A Study on E-business Possibility through the Characteristic Analysis of Smart Phone Market in South Asia : Focusing on Vietnam

  • Kim, Dong-Hwa;Sung, Seo-Dae
    • East Asian Journal of Business Economics (EAJBE)
    • /
    • v.5 no.3
    • /
    • pp.33-40
    • /
    • 2017
  • Purpose - This paper suggests approaching methods for a way of strategies for traditional market extend and new ebusiness, market development, and plan of new product in the future and develop a way of method for cooperation through analysis on the smart phone market trend in different culture, effectively. Research design, data, methodology - As research design, data, and methodology, this paper suggests new idea and approaches from comparing characteristics analysis of smart phone market in different culture in AEC. This paper takes data to analysis from ITU, World Bank, AEC, and IMF. These organizer's data can be trusted as official society in the world. This paper can prove market and the characteristics of society through the corresponding results. Results - This paper can suggest the novel idea on market development and the big possibility depend on ACE country and can describe the possibility on new market because of low smart phone market penetration and low digital market penetration. Conclusions - This paper concludes to develop e-business, culture friendly ship, linking with education, development of appropriate technology depend on country, and should develop new strategy for market extend to low penetration.

The Influence of the Change of Patient Radiation Exposure Dose Distribution on the Grid Condition and Detector Acquisition Dose on the Exposure Distance in the Use of Amorphous Silicon Thin Film Transistor Detector with AEC (자동노출제어장치를 이용한 비정질 실리콘 평판형 검출기에서 격자의 조건에 따른 환자선량 변화와 촬영 거리의 변화가 검출기 획득선량에 미치는 영향)

  • Yoon, Seok-Hwan;Choi, Jun-Gu;Han, Dong-Kyoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.23-30
    • /
    • 2007
  • This study attempts to propose an appropriate method of using digital medical imaging equipments, by studying the effects of automatic exposure control(AEC), grid ratio and the change of radiography distance on the patient dose and detertor acquisition dose during the procedure of acquiring image through a digital medical imaging detector. The change of dose following the change of grid ratio's exposure and radiography distance was measured, by using an abdominal phantom organized with tissue equivalent materials in an amorphous silicon thin film transistor detecter installed with AWC. The case to use grid ratio 12 : 1, focal distance 180cm to radiography distance 110cm in AEC, the patient dose increased rather when we used grid ration 10 : 1, focal distance 110cm. When AEC was not used,the dose necessary for image acquisition decreased as the grid ratio became higher and the distance became further. but detector acquisition dose was not reduced when in applied AEC. When purchasing digiral medical imaging equipments, optional items such as AEC and grid shall be accurately selected to satisfy the use of the equipments. Radiography error made by radiation technologist and unnenessary patient dose can be reduced by selecting equipments with a radiography distance marker equipment when it did not apply AEC. These equipments can also be helpful in maintaining high imaging quality, one of the merits of digital detectors.

  • PDF

Correlation Analysis of Control Factors in Automatic Exposure Control of Digital Radiography System Based on Fine Contrast Images (미세 대조도 영상을 기반한 디지털 방사선 영상 시스템의 자동노출제어 조절인자 간의 상관관계 분석)

  • Lim, Se-Hun;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.44 no.1
    • /
    • pp.1-8
    • /
    • 2021
  • The purpose of this study was to analyze the effect of automatic exposure control (AEC) control factors in digital radiography systems based on the fine contrast images using coin phantoms. The AEC control factors were targeted at the range of dominent zone, sensitivity, and density. The dominent zone was divided into cases where a single coin was used to cover the field configuration, and cases where seven coins were used to cover the field configuration. The sensitivity was classified into three stages (200, 400, 800) and the density was classified into three stages (2.5, 0, 2.5). Image quality was evaluated by signal to noise ratio (SNR) and contrast to noise ratio (CNR). Then, the automatically exposed tube current was measured. As a result, the X-ray image of seven coins obtained a result value of about 1.2 times higher for SNR and 1.9 times higher for CNR than the X-ray image for one coin. The tube current was also about 1.6 times higher. In conclusion, In AEC, the higher the field configuration and dominent zone are matched and the higher the density, the lower the sensitivity, which increases the tube current and CNR, which increases the image quality. Therefore, it is judged that the appropriate setting of the range of dominent zone, sensitivity, and density of the control, which is the AEC control factor, could improve the fine contrast of images.

Radiation Dose Comparison according to Different Organ Characteristics at Same Scan Parameters Using CareDose 4D: An Adult and Pediatric Phantom Evaluation (CareDose 4D 사용 시 동일한 스캔조건에서 조직기반설정을 다르게 적용함에 따른 선량 비교: 성인과 소아팬텀 연구)

  • Kong, Hyo-Geum;Lee, Ki-Baek
    • Journal of radiological science and technology
    • /
    • v.42 no.4
    • /
    • pp.271-277
    • /
    • 2019
  • CareDose 4D which is the Siemens's Automatic Exposure Control (AEC) can adjust the level of radiation dose distribution which is based on organ characteristic unlike other manufacturer's AEC. Currently, a wide scan range containing different organs is sometimes examined at once (defined as one scan). The purpose of this study was to figure out which organ characteristic option is suitable when one scan method is utilized. Two types of anthropomorphic phantoms were scanned in the same range which were from frontal bone to carina level according to three different organ characteristics such as Thorax, Abdomen, and Neck. All scans and image reconstruction parameters were equally applied and radiation dose were compared. Radiation dose with Thorax organ characteristic was lower than that with Neck. Also, that with Abdomen oran characteristic was lower than Thorax. There were significant differences in radiation dose according to different organ characteristics at the same parameters (P<0.05). Usage of Neck organ characteristic had a result of the highest radiation dose to all phantom. On the other hand, utilization of Abdomen organ characteristic showed the lowest radiation dose. As a result, it is desirable to set appropriate organ characteristic according to examined body part when you checkup patients. Also, when you implement one scan method, selection of Abdomen-based organ characteristic has reduced more radiation dose compared with two different organ characteristic.