• Title/Summary/Keyword: AE sensors

Search Result 151, Processing Time 0.024 seconds

Reliability of joint angle during sit-to-stand movements in persons with stroke using portable gait analysis system based wearable sensors

  • An, Jung-Ae;Lee, Byoung-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.8 no.3
    • /
    • pp.146-151
    • /
    • 2019
  • Objective: The purpose of this study was to investigate the test-retest reliability and concurrent validity of the joint angle of the lower extremities during sit-to-stand movements with wearable sensors based on a portable gait analysis system (PGAS), and the results were compared with a analysis system (MAS) to predict the clinical potential of it. Design: Cross-sectional study. Methods: Sixteen persons with stroke (9 males, 7 females) participated in this study. All subjects had the MAS and designed PGS applied simultaneously and eight sensor units of designed PGAS were placed in a position to avoid overlap with the reflexive markers from MAS. The initial position of the subjects was 90º of hip, knee, and ankle joint flexion while sitting on a chair that was armless and backless. The height of the chair was adjusted to each individual. After each trial, the test administrator checked the quality of data from both systems that measured sit-to-stand for test-retest reliability and concurrent validity. Results: As a result, wearable sensor based designed PGAS and MAS demonstrated reasonable test-retest reliability for the assessment of joint angle in the lower extremities during sit-to-stand performance. The intra-class correlation coefficients (ICCs) for wearable sensor based designed PGAS showed an acceptable test-retest reliability, with ICCs ranging from 0.759 to 0.959. In contrast, the MAS showed good to excellent test-retest reliability, with ICCS ranging from 0.811 to 0.950. In concurrent validity, a significant positive relationship was observed between PGAS and MAS for variation of joint angle during sit-to-stand movements (p<0.01). A moderate to high relationship was found in the affected hip (r=0.665), unaffected hip (r=0.767), affected knee (r=0.876), unaffected knee (r=0.886), affected ankle (r=0.943) and unaffected ankle (r=0.823) respectively. Conclusions: The results of this study indicated that wearable sensor based designed PGAS showed acceptable test-retest reliability and concurrent validity in persons with stroke for sit-to-stand movements and wearable sensors based on developed PGAS may be a useful tool for clinical assessment of functional movement.

Multi-Label Activity Recognition based on Inertial Sensors (관성 센서에 기반한 멀티 레이블 행위 인지)

  • Hur, Taeho;Kim, Seong-Ae;Lee, Sungyoung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2017.04a
    • /
    • pp.181-182
    • /
    • 2017
  • 관성 센서 기반 행위인지는 스마트폰과 웨어러블 밴드 등의 출현으로 보다 간편한 방법으로 행위인지가 가능해졌다. 현재 대부분의 행위인지 서비스나 연구들은 단일 행위의 결론만을 도출하고 있으나, 이러한 방식은 한 행위에서 한 가지 동작밖에 취할 수 없는 경우에는 문제가 없지만 두 가지 이상의 동작이 합쳐진 경우에 어떤 행위를 최종 결론으로 도출해야 하는지에 대한 문제점을 내포한다. 따라서 본 논문에서는 이러한 문제점을 해결하기 위해 세 개의 센서 기기 (스마트폰, 스마트워치, 웨어러블 센서)를 이용한 멀티 레이블 행위인지를 제안한다. 스마트폰은 신체 전반적인 움직임 탐지를 위하여 소지위치가 정해지지 않은 비고정식 센서의 보조적인 역할을 수행한다. 스마트워치는 사용자가 주로 사용하는 손의 손목, 그리고 웨어러블 센서는 사용자의 허벅지에 부착되어 각각 상하체의 움직임을 파악한다. 이후 각 기기에서 도출된 결론에 Majority Weighted Voting 기법을 적용하여 단일 혹은 멀티 레이블의 최종 행위를 도출한다.

Diagonoses of Power Transformer Using Acoustic Emission Techniques (음향기술을 이용한 전력용 변압기 예방진단)

  • Hwang, S.J.;Kwak, H.R.;Jeon, H.J.;Kim, J.C.;Park, J.W.;Choi, S.A.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.938-941
    • /
    • 1992
  • This paper presents an acoustic emission(AE) technique using ultrasonic sensors to diagonize power transformers. Conventional methods detect and measure the electrical signal of the partial discharge(PD) of transformers in operation. The proposed techniques measures the acoustic signal generated by the partial discharge, and counts the number of the waveforms above a threshold to diagonize transformers. Experiments showed that the proposed method improved diagonosis capability over the conventional PD method.

  • PDF

Characteristics of Elastic Waves Generated by Fatigue Crack Penetration and Growth in an Aluminum Plate

  • Ahn, Seok-Hwan;Nam, Ki-Woo
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.11
    • /
    • pp.1599-1607
    • /
    • 2003
  • The characteristics of elastic waves emanated from crack initiation in 6061 aluminum alloy subjected to fatigue loading are investigated through experiments. The objective of the study is to determine the differences in the properties of the signals generated from fatigue test and also to examine if the sources of the waves could be identified from the temporal and spectral characteristics of the acoustic emission (AE) waveforms. The signals are recorded using nonresonant, flat, broadband transducers attached to the surface of the alloy specimens. The time dependence and power spectra of the signals recorded during the tests were examined and classified according to their special features. Six distinct types of signals were observed. The waveforms and their power spectra were found to be dependent on the crack propagation stage and the type of fracture associated with the signals. The potential application of the approach in health monitoring of structural components using a network of surface mounted broadband sensors is discussed.

Study of Signal Characteristics of Matrix Cracks in Composites Using Wavelet Transform (웨이블릿 변환을 이용한 복합재 모재균열의 신호특성 분석)

  • 방형준;김대현;강동훈;홍창선;김천곤
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.151-154
    • /
    • 2002
  • The objective of this study is to find the change of signal characteristics of matrix cracks due to the different specimen shapes. As the concept of the smart structure, monitoring of acoustic emission (AE) can be applied to inspect the fracture of the structures in operating condition using built-in sensors. To understand the characteristics of matrix crack signals, we performed tensile tests by changing the thickness and width of the specimens. This paper describes the implementation of time-frequency analysis such as wavelet transform (WT) fur the quantitative evaluation of fracture signals. The experimental result shows the distinctive signal features in frequency domain due to the different specimen shapes.

  • PDF

Damage Detection of Fiber-Metal Laminates Under Axial and Indentation Load (섬유-금속 적층판의 인장 및 압입 하중에서의 손상감지)

  • Yang, Yoo-Chang;Han, Kyung-Seop
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.370-375
    • /
    • 2003
  • Optical fiber vibrations sensors (OFVSs) and extrinsic Fabry-Perot interferometer (EFPI) were used in damage monitoring of fiber-metal laminates(FML). The optical fiber vibration sensor and EFPI were applied in order to detect and evaluate the strain, damage and failure of FML. Damages in composites, such as matrix cracks, delamination and fiber breakage may occur as a result of excessive load, fatigue and low-velocity impacts. Tensile and indentation test was performed with the measurement of optical signal and acoustic emission (AE). The signals of the optical fiber vibration sensor due to damages were quantitatively evaluated by wavelet transform. It was found that damage information of comparable in quality to acoustic emission data could be obtained from the optical fiber vibration sensor signals.

  • PDF

Electroglottographic Spectral Tilt in Frequency Ranges of Vowel Sound (모음 주파수 범위에 따른 성문전도 스펙트럼 기울기)

  • Kim, Ji-Hye;Jang, Ae-Lan;Jung, Dong-Keun
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.247-251
    • /
    • 2015
  • In this study, electroglottographic spectral tilt (EST) was investigated for characterization of vocal cords vibration. EST was analyzed from the power spectrum of electroglottographic signals by dividing frequency analysis range as full range (0~4 octave), low range (0~2 octave), and high range (2~4 octave). EST of all ranges in female were greater than those in male. In female and male groups, EST of high range was higher than that of low range. This result suggests that EST has at least two components and dividing frequency range in analysis of EST is effective for investigating characteristics of vocal cords vibration.

Monitoring and machinability evaluation in high-speed machining of high hardness steel(SKD11) (고경도강(SKD11)의 고속가공에서 가공성 평가 및 감시)

  • 김전하;김경균;강영창;김정석;김기태
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.987-990
    • /
    • 2000
  • In modern manufacturing industry such as aerospace, vehicle and die/mold industry, the high hardness malarial which is remarkable in aspects of durability is effectively used. The high-speed and precision machining technology has been applied in these fields. In this study, efficient sensors in high-speed machining by observing similar tendency through comparing cutting force with AE signal, gap sensor signal and accelerometer signal are selected, and machinability of high-speed machining is experimentally evaluated. We performed a basic research for sensing system construction to monitor a machine tool and machining condition.

  • PDF

Development of Diagnostic Expert System for Rotating Machinery with Journal Bearing (저어널 베어링으로 지지된 회전축의 이상상태 진단을 위한 진단전문가 시스템의 개발)

  • 유송민;김영진;박상신
    • Tribology and Lubricants
    • /
    • v.17 no.3
    • /
    • pp.244-250
    • /
    • 2001
  • A rotating axis diagnostic system supported with journal bearing has been established that has been widely used in the industry. In order to measure the most sensitive signals that would be generated in the abnormal operation, sensors which measure AE(acoustic emission), gap and acceleration have been attached at the various location on the experimental apparatus. Data were obtained in the steady state operational condition of the system which was verified through the empirical measurement. Notable discrepancies were observed in RMS acceleration signal which could be utilized to predict the undesirable operational condition of the system.

Damage and Failure Detection of Fiber-Metal Laminates Under Indentation Load (섬유-금속 적층판의 압입 하중에서의 손상 및 파손 검출)

  • 양유창;한경섭
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.04a
    • /
    • pp.42-45
    • /
    • 2003
  • Optical fiber vibrations sensors (OFVSs) and extrinsic Fabry-Perot interferometer (EFPI) were used in damage monitoring of fiber-metal laminates(FML). The optical fiber vibration sensor and EFPI were applied in order to detect and evaluate the strain, damage and failure of FML. Damages in composites, such as matrix cracks, delamination and fiber breakage may occur as a result of excessive load, fatigue and low-velocity impacts. Indentation test was performed with the measurement of optical signal and acoustic emission (AE). The signals of the optical fiber vibration sensor due to damages were quantitatively evaluated by wavelet transform. It was found that damage information of comparable in quality to acoustic emission data could be obtained from the optical fiber vibration sensor signals.

  • PDF