• 제목/요약/키워드: AE monitoring

검색결과 492건 처리시간 0.027초

Crack source location by acoustic emission monitoring method in RC strips during in-situ load test

  • Shokri, Tala;Nanni, Antonio
    • Smart Structures and Systems
    • /
    • 제13권1호
    • /
    • pp.155-171
    • /
    • 2014
  • Various monitoring techniques are now available for structural health monitoring and Acoustic Emission (AE) is one of them. One of the major advantages of the AE technique is its capability to locate active cracks in structural members. AE crack locating approaches are affected by the signal attenuation and dispersion of elastic waves due to inhomogeneity and geometry of reinforced concrete (RC) members. In this paper, a novel technique is described based on signal processing and sensor arrangement to process multisensory AE data generated by the onset and propagation of cracks and is validated with experimental results from an in-situ load test. Considering the sources of uncertainty in the AE crack location process, a methodology is proposed to capture and locate events generated by cracks. In particular, the relationship between AE events and load is analyzed, and the feasibility of using the AE technique to evaluate the cracking behavior of two RC slab strips during loading to failure is studied.

AE신호를 이용한 micro-grooving의 상태감시 (State Monitoring of Micro-Grooving using AE Signal)

  • 이희석;손성민;김성렬;안중환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.332-335
    • /
    • 1997
  • With the advance of precision technique, the optical system is more precise and complex and the machining method of optical element which is composed of micro-grooves is developed. Especially, the method of micro-grooving using diamond tool is used widely owing to many merit, but has problems of damage of surface roughness due to tool wear and tool fracture. This paper deals with state monitoring using AE RMS in the micro-grooving. The change of AE RMS is very small with increment of cutting velocity and depth of cut. In spite of constance magnitude of principal force in machining using diamond tool of tool wear and tool fracture, AE RMS is highly fluctuated. Because changing of cutting state has relevance to surface roughness profile, surface toughness profile is expected using AE RMS.

  • PDF

AE신호 분석을 통한 비자성체의 자기연마 모니터링에 관한 연구 (A Study on Monitoring of the MAP for Non-magnetic Material by AE Signal Analysis)

  • 이성호;김상오;곽재섭
    • 한국생산제조학회지
    • /
    • 제20권3호
    • /
    • pp.304-309
    • /
    • 2011
  • A monitoring system for magnetic abrasive polishing process is necessary to ensure the polishing products the high quality and integrity. Acoustic emission (AE) signal is known to reflect the material removal phenomena in other machining processes. In a case of the magnetic abrasive polishing of non-magnetic materials, application of AE method is very difficult because of lower machining force on the surface of workpiece and the level of AE signal is extremely lower. In this study, AE sensor-based monitoring system is applied to the magnetic abrasive polishing. The relation between the level of the AE RMS and the surface roughness during the magnetic abrasive polishing of magnesium alloy steel is investigated.

이종강관 마찰용접의 소성변형 중 발생된 초기 AE양이 용접품질 제어에 미치는 영향에 관한 연구 (Effects of Initial AE Counts During Plastic Deformation in Friction \elding of Dissimilar Steel Tubes on the Weld Quality Control)

  • 오세규;김동조;정락기
    • Journal of Welding and Joining
    • /
    • 제1권2호
    • /
    • pp.69-75
    • /
    • 1983
  • Both in-process quality control and reliability of the weld is one of the major concerns is applying friction welding. No reliable nondestructive monitoring method is available at present to determine the weld quality particularly in process of production. So that, this paper presents an experimental examination and quantitative analysis for the effects of initial acoustic emission(AE) counts on the weld strength relating to the rotating speed as a new approach which attempts finally to develop an on-line quality monitoring system design for friction welds using AE techniques. As one of the important results, it was well confirmed that the initial AE counts occurring during plastic deformation period of welding were quantitatively correlated with reliability at 95% confidence level to the joint strength of welds, tube-to-tube (SM 20 C to STS 304) and then an AE technique using the initial AE counts can be reliably applied to in-process strength monitoring of the weld.

  • PDF

고속태핑에서 AE센서를 이용한 소구경 탭의 파손감시의 가능성 연구 (Feasibility Study on Monitoring of Small-Diameter Tap Breakage with AE Sensor in High-Speed Tapping)

  • 이돈진;김선호;안중환
    • 한국정밀공학회지
    • /
    • 제20권10호
    • /
    • pp.41-46
    • /
    • 2003
  • This paper deals with the possibility of tap breakage detection by AE sensor. AE signals in the tapping were not seldom generated in low speed but reflected the tapping process exactly in high speed. Using AE raw signals sampled in 500kHz, AE RMS and AE count rate was computed in software. When the converting time of AE RMS is less than 10ms, we could distinguish between normal cutting and tap breakage. And AE count rate was more exact when the converting time is greater than 1ms. When two methods were compared to each other, AE count rate was more accurate.

발전용 밸브누설 음향 진단 및 감시시스템 (Acoustic Valve Leak Diagnosis and Monitoring System for Power Plant Valves)

  • 이상국
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.425-430
    • /
    • 2008
  • To verify the system performance of portable AE leak diagnosis system which can measure with moving conditions, AE activities such as RMS voltage level, AE signal trend, leak rate degree according to AE database, FFT spectrum were measured during operation on total 11 valves of the secondary system in nuclear power plant. AE activities were recorded and analyzed from various operating conditions including different temperature, type of valve, pressure difference, valve size and fluid. The results of this field study are utilized to select the type of sensors, the frequency band for filtering and thereby to improve the signal-to-noise ratio for diagnosis for diagnosis or monitoring of valves in operation. As the final result of application study above, portable type leak diagnosis system by AE was developed. The outcome of the study can be definitely applied as a means of the diagnosis or monitoring system for energy saving and prevention of accident for power plant valve. The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the major valves at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized temperature water and steam flowed through glove valve(main steam dump valve) and check valve(main steam outlet pump check valve) on the normal size of 12 and 18 ". The valve internal leak monitoring system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, frequency analysis, voltage analysis and amplitude analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

AE에 의한 평면연삭의 가공특성 감시 및 이상진단 (Detection of abnormal conditions and monitoring of surface ginding characteristics by acoustic emission)

  • Lim, Y.H.;Kwon, D.H.;Choi, M.Y.;Lim, S.J.
    • 한국정밀공학회지
    • /
    • 제12권4호
    • /
    • pp.100-110
    • /
    • 1995
  • This paper aims at reviewing the possibility of application over normal or abnormal, detection used by AE, and the characteristics of grinding processes. In this study, when WA-vitri-fied ' resinoid bond grinding wheels:36 kinds of grinding wheel and grinding depth were tuned at the surface grinding, the zone of AE signal generation is theoretically modelled and reviewed by grinding processes. The variation of grinding resistance( F$n^{9}$ $F_{t}$) and AE signal is detected in-process by the use of AE measuring system. The tests are carried out in accordance with grain size and grade of grinding wheels, and work-pieces-STD11 and STD61. According to the experiment's results, the following can be expected;as grinding time passes by, the relation of grinding depth and quantity of AE signal, observing on AE signal and grinding burn suggest the characteristics of grinding processes and evalution on the possibility of control of grinding machine, and monitoring abnormal conditions.e, and monitoring abnormal conditions.

  • PDF

Acoustic emission localization in concrete using a wireless air-coupled monitoring system

  • Yunshan Bai;Yuanxue Liu;Guangjian Gao;Shuang Su
    • Smart Structures and Systems
    • /
    • 제32권4호
    • /
    • pp.195-205
    • /
    • 2023
  • The contact acoustic emission (AE) monitoring system is time-consuming and costly for monitoring concrete structures in large scope, in addition, the great difference in acoustic impedance between air and concrete makes the detection process inconvenient. In this work, we broaden the conventional AE source localization method for concrete to the non-contact (air-coupled) micro-electromechanical system (MEMS) microphones array, which collects the energy-rich leaky Rayleigh waves, instead of the relatively weak P-wave. Finite element method was used for the numerical simulations, it is shown that the propagation velocity of leaky Rayleigh waves traveling along the air-concrete interface agrees with the corresponding theoretical properties of Lamb wave modes in an infinite concrete slab. This structures the basis for implementing a non-contact AE source location approach. Based on the experience gained from numerical studies, experimental studies on the proposed air-coupled AE source location in concrete slabs are carried out. Finally, it is shown that the locating map of AE source can be determined using the proposed system, and the accuracy is sufficient for most field monitoring applications on large plate-like concrete structures, such as tunnel lining and bridge deck.

AE 감시 장치를 이용한 센터리스 연삭 공적의 감시 (Process Monitoring of Centerless Grinding Using an AE Monitoring Unit)

  • 김성렬;김화영;김선호;안중환
    • 한국정밀공학회지
    • /
    • 제16권1호통권94호
    • /
    • pp.108-115
    • /
    • 1999
  • Since grinding is a more complicated process than any other machining process, it is hard for operators to setup a grinding machine properly and to find out correctly abnormal grinding states resulting in damages to products. Abnormalities would be caused by improper setup, improper dressing/grinding conditions which are likely to be occurred without skilled operators' attention. In this study, an AE monitoring unit is developed to help operators conduct with ease setup, and set properly dressing/grinding conditions. AErms(root-mean-square) signal being monitored, on-going process states during grinding and dressing is visualized for machine operators to judge whether the processes are in good condition. Evaluation tests are carried out on centerless grinding machines-both cylindrical and internal. The developed AE monitoring system is verified to be useful to check grinding/dressing states in process even in the centerless grinding of which process is most unknown among various grinding methods because of the complex structure.

  • PDF