• 제목/요약/키워드: AE Technique

검색결과 533건 처리시간 0.029초

치근단 농양에 의해 발생된 급성 중증 안구주위부종 1례 (Acute Severe Periocular Swelling Caused by Periapical Abscess in a Dog)

  • 박영우;박신애;김원태;김세은;김태현;안재상;윤정희;서강문
    • 한국임상수의학회지
    • /
    • 제26권5호
    • /
    • pp.483-485
    • /
    • 2009
  • A 10-year-old, intact female Yorkshire terrier was presented with right side facial swelling for 3 days and periocular swelling had progressed over the last 24 hours. On physical examination, periocular and infraorbital swelling were observed around right maxillary region. Severe ocular discharge and protrusion of the 3rd eyelid were observed. The patient was diagnosed as periapical abscess around the root of right upper first molar based on the skull radiography. Affected tooth was extracted using closed technique. Systemic corticosteroid and antibiotic were administrated and topical corticosteroid/antibiotic combination was applied to the right eye six times a day for 10 days. Ten days after tooth extraction, clinical signs were disappeared completely.

The electronic structure of the ion-beam-mixed Pt-Cu alloys by XPS and XANES

  • Lim, K.Y.;Lee, Y.S.;Chung, Y.D.;Lee, K.M.;Jeon, Y.;Whang, C.N.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1998년도 제14회 학술발표회 논문개요집
    • /
    • pp.133-133
    • /
    • 1998
  • In the thin film alloy formation of the transition metals ion-beam-mixing technique forms a metastable structure which cannot be found in the arc-melted metal alloys. Sppecifically it is well known that the studies about the electronic structure of ion-beam-mixed alloys pprovide the useful information in understanding the metastable structures in the metal alloy. We studied the electronic change in the ion-beam-mixed ppt-Ct alloys by XppS and XANES. These analysis tools pprovide us information about the charge transfer in the valence band of intermetallic bonding. The multi-layered films were depposited on the SiO2 substrate by the sequential electron beam evapporation at a ppressure of less than 5$\times$10-7 Torr. These compprise of 4 ppairs of ppt and Cu layers where thicknesses of each layer were varied in order to change the alloy compposition. Ion-beam-mixing pprocess was carried out with 80 keV Ae+ ions with a dose of $1.5\times$ 1016 Ar+/cm2 at room tempperature. The core and valence level energy shift in these system were investigated by x-ray pphotoelectron sppectroscoppy(XppS) pphotoelectrons were excited by monochromatized Al K a(1486.6 eV) The ppass energy of the hemisppherical analyzer was 23.5 eV. Core-level binding energies were calibrated with the Fermi level edge. ppt L3-edge and Cu K-edge XANES sppectra were measured with the flourescence mode detector at the 3C1 beam line of the ppLS (ppohang light source). By using the change of White line(WL) area of the each metal sites and the core level shift we can obtain the information about the electrons pparticippating in the intermetallic bonding of the ion-beam-mixed alloys.

  • PDF

현대의 전통한복에 사용된 장식기법에 관한 연구[제 I 보] - 2001~2005년도 여자한복을 중심으로 - (A Study on Decoration Techniques Applied to the Korean Traditional Costume of Contemporary Style[Part I] - Focusing on Korean Traditional Costumes for Women which were Delivered between 2001 and 2005 -)

  • 김순구;이영애
    • 한국의류산업학회지
    • /
    • 제12권5호
    • /
    • pp.564-573
    • /
    • 2010
  • The purpose of this study is to investigate decoration techniques applied to the Korean traditional costume of modern style which are shown in special monthly magazines relevant to the traditional magazine. Findings of the study can be summarized as follows. The types of decoration techniques applied to the Korean traditional costume are largely classified into single and composite types. In the traditional costume of the former type, a quite many of gold and silver foils and embroideries are found. While, in that of the latter type, a combination of two different decorations, embroideries and seonchigi or multi-colored stripes and seonchigi is often used. These decoration techniques are usually applied to some parts of the costume like git, kkeutdong or cuffs, somae or sleeves, seop, goreum or coat strings, jacket or jeogori, the lower hem of the skirt and between joined parts in the skirt. Used together with the techniques, patterns are usually applied onto embroideries and gold or silver foils. Most of the patterns are flower in shape. The main material of the Korean traditional costume is fabrics that have no pattern on the surface and are commercially available irrespective of season. Git used for jeogori is largely classified into dangko git and donggrae git in type. Its color is in most cases same as the main color of jeogori. Keutdong for jeogori is usually 4 to 5.5 cm in breadth, classified as type II. Its color is in most cases white. Goreum for jeogori is usually large in length. Its color is most cases same as that of jegori or reddish purple or blackish red purple.

PGE1-ethyl Ester함유 발기부전 치료용 요도주입 액제의 제조 및 평가 (Preparation and Evaluation of PGE1-ethyl Ester Intraurethral Solutions for Erectile Dysfunction)

  • 최한곤;유봉규;이종달;김정애;권태협;우종수;용철순
    • Journal of Pharmaceutical Investigation
    • /
    • 제36권4호
    • /
    • pp.223-229
    • /
    • 2006
  • [ $PGE_1$ ]-ethyl ester intraurethral solutions were prepared in ethanol/propylene glycol mixture with penetration enhancer and viscosity-enhancing agent. The stability of $PGE_1$-ethyl ester in intraurethral solution was investigated at various temperature. Simultaneous determination of $PGE_1$-ethyl ester and $PGE_1$ was performed using a validated HPLC technique. In pentobarbital anesthetized cats, increase in intracavernous pressure(ICP), increase in penile length and duration of erectile response were determined after intraurethral application of $PGE_1$-ethyl ester solutions. $PGE_1$-ethyl ester solutions, when instilled into the eyes of rabbits, produces no noticeable irritation, or slight transient conjunctival irritation. From these results, ocular irritation of this solutions was judged as practically non-irritating. The stability study indicates that the therapeutically effective content in solution is well maintained for 46 weeks or longer when they are stored at $4^{\circ}C$. After intraurethral application of $PGE_1$-ethyl ester, ICP was increased and penile erection was induced. $PGE_1$-ethyl ester intraurethral solutions for erectile dysfunction could be developed and evaluated by employing feline erection model.

Drosophila single P[en-lacZ] element mutagenesis를 이용한 발생 관련 돌연변이체 작성 (Screening and Characterization of Drosophila Development Mutants Using Single P[en-lacZ] Element Mutagenesis)

  • 하혜영;이희정;박순희;유미애;이원호
    • 생명과학회지
    • /
    • 제7권1호
    • /
    • pp.49-58
    • /
    • 1997
  • Engralied 5.7kb upstream sequence와 E. colilacZ의 융합 유전자를 가진 P[en-lacZ] 인자를 jumpstart 기법을 이용하여, ryXho25 strain의 초파리 48A 염색체 위치로부터 새로운 위치로 삽입하였다. 총 3315의 유전적 교배를 통해서, P[en-lacZ] 가 다른 염색체 상으로 삽인된 113 계통을 얻었다. X-gal 염색으로 이들 113 계통의 3령기 유충 조직에서의 $\beta$-galactosidase 발현을 조사하였다. 도한 113 계통 중 7계통이 열성치사돌연변이인 것으로 동정되었다. 이들 7 계통 중 초기 배발생 과정에서 치사하는 것으로 조사된 #1119의 초기 배발생 과정에서의 ${\beta}$-galactosidase 발현과 핵의 이동 및 세포화 양상을 조사하였다. 본 연구에서 얻어진 P[en-lacZ] 삽입 돌연변이체들은 앞으로 Drosophila 발생에 관련된 유전자들의 구조와 기능을 연구하는데 활용될 수 있을 것이다.

  • PDF

Parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an Asian population

  • Lee, Yoon Jae;Kim, SeongAe;Lee, Jisung;Chung, Joong Geel;Jun, Young Joon
    • Archives of Plastic Surgery
    • /
    • 제47권2호
    • /
    • pp.171-177
    • /
    • 2020
  • Background Infrabrow blepharoplasty has become a common surgical method used to rejuvenate aged upper eyelids in Asians. In this paper, we describe the parallel excision method for infrabrow blepharoplasty as a useful alternative to the conventional elliptical excision method. The authors' experience over a 3-year period is presented and reviewed. Methods A retrospective review of parallel excision infrabrow blepharoplasty cases at our hospital between 2014 and 2017 was performed. Three oculoplastic surgeons compared preoperative and postoperative photographs using the Strasser grading system. Results From the medical records of 123 patients, a total of 93 patients with moderate-to-severe bilateral dermatochalasis were selected as subjects. The exclusion criterion was levator function less than 8 mm. The total mean follow-up period was 2 years (range, 0.5-3.5 years). The mean skin excision height and width were 9.75 mm (range, 5-16 mm) and 58.51 mm (range, 42-75 mm), respectively. All patients who underwent surgery recovered without major complications, and all patients had high levels of satisfaction and improvements in their visual field. In the Strasser evaluation performed by the oculoplastic surgeons, most patients were found to have excellent results. Conclusions The parallel excision method for infrabrow blepharoplasty is a safe and effective technique that yields more natural- and youthful-looking eyelids than the conventional elliptical excision method. In our method, more effective manipulation of the orbicularis oculi muscle led to a reduction in frontalis compensation, resolution of sunken eyelids, and correction of lateral hooding.

효율적인 약물 방출 스텐트 제조를 위한 고분자 코팅물질 개발 (Development of Polymeric Coating Material for Effective Drug-eluting Stent)

  • 박태현;조은애;나건
    • 폴리머
    • /
    • 제35권5호
    • /
    • pp.483-487
    • /
    • 2011
  • 효율적 비혈관용 약물방출 스텐트 제조를 위해 풀루란 아세테이트(pullulan acetate, PA)가 테프론(poly-tetrafluorethylene; PTFE)으로 피막된 스텐트(PTFE-stent)의 코팅재료로 연구되었다. 파크리탁셀 함유 PA가 코팅된 PTFE-stent의 표면, 약물 방출 거동, 세포독성이 측정되었으며, 동물실험을 통해 이의 가능성이 검토되었다. 전자현미경으로 표면을 관찰한 결과 표면이 PTFE 피막에 비해 훨씬 매끄러웠고, 약물은 80일 동안 서방적 방출 거동을 보였다. PA와 함께 코팅된 파크리탁셀의 안정성을 annexin V 결합 염색법을 통하여 측정한 결과 apoptosis의 비율이 천연 파크리탁셀과 유사한 것으로 보아 봉입된 파크리탁셀의 변성이 없음을 알 수 있었다. 소동물 실험에서는 파크리탁셀이 봉입된 PA-PTFE가 고형암의 성장을 억제하였다. 위의 결과로 보아 PA는 효율적 비혈관계 약물방출 스텐트 개발에 매우 유용한 물질이라고 기대된다.

The first insight into the structure of the Photosystem II reaction centre complex at $6{\AA}$ resolution determined by electron crystallography

  • Rhee, Kyong-Hi
    • 한국식물학회:학술대회논문집
    • /
    • 한국식물학회 1999년도 Proceedings of the 17th Symposium on Plant Biology Environmental Stress and Photosynthesis
    • /
    • pp.83-90
    • /
    • 1999
  • Electron crystallography of two-dimensional crystalsand electron cryo-microscopy is becoming an established method for determining the structure and function of a variety of membrane proteins that are providing difficult to crystallize in three dimension. In this study this technique has been used to investigate the structure of a ~160 kDa reaction centre sub-core complex of photosystem II. Photosystem II is a photosynthetic membrane protein consisting of more than 25 subunits. It uses solar energy to split water releasing molecular oxygen into the atmosphere and creates electrochemical potential across the thylakoid membrane, which is eventually utilized to generate ATP and NADPH. Images were taken using Philips CM200 field emission gun electron microscope with an acceleration voltage of 200kW at liquid nitrogen temperature. In total, 79 images recorded dat tilt angles ranging from 0 to 67 degree yielded amplitudes and phases for a three-dimensional map with an in-plant resolution of 6$\AA$ and 11.4$\AA$ in the third dimension shows at least 23 transmembrane helices resolved in a monomeric complex, of which 18 were able to be assigned to the D1, D2, CP47 , and cytochrome b559 alfa beta-subunits with their associated pigments that ae active in electron transport (Rhee, 1998, Ph.D.thesis). The D1/D2 heterodimer is located in the central position within the complex and its helical scalffold is remarkably similar to that of the reaction centres not only in purple bacteria but also in plant photosystem I (PSI) , indicating a common evoluationary origin of all types of reaction centre in photosynthetic organism known today 9RHee et al. 1998). The structural homology is now extended to the inner antenna subunit, ascribed to CP47 in our map, where the 6 transmembrane helices show a striking structural similarity to the corresponding helices of the PSI reaction centre proteins. The overall arrangement of the chlorophylls in the D1 /D2 heterodimer, and in particular the distance between the central pair, is ocnsistent with the weak exciton coupling of P680 that distinguishes this reaction centre from bacterial counterpart. The map in most progress towards high resolution structure will be presented and discussed.

  • PDF

Simultaneous Detection of 10 Foodborne Pathogens using Capillary Electrophoresis-Based Single Strand Conformation Polymorphism

  • Oh, Mi-Hwa;Hwang, Hee-Sung;Chung, Bo-Ram;Paik, Hyun-Dong;Han, Sang-Ha;Kang, Sun-Moon;Ham, Jun-Sang;Kim, Hyoun-Wook;Seol, Kuk-Hwan;Jang, Ae-Ra;Jung, Gyoo-Yeol
    • 한국축산식품학회지
    • /
    • 제32권2호
    • /
    • pp.241-246
    • /
    • 2012
  • This report outlines the development of a rapid, simple, and sensitive detection system for pathogenic bacteria using a capillary electrophoresis-based, single strand conformation polymorphism (CE-SSCP) combined with PCR. We demonstrate that this method, used with primers targeting the V4 region of the16S rRNA gene, is capable of the simultaneous detection of 10 microbes that could be associated with foodborne illness, caused by animal-derived foods: Salmonella enterica, Listeria monocytogenes, Escherichia coli O157:H7, Campylobacter jejuni, Staphylococcus aureus, Bacillus cereus, Clostridium perfringens, Yersinia enterocolitica, Vibrio parahaemolyticus, and Enterobacter sakazakii. The traditional detection techniques are time-consuming and labor-intensive, due to the necessary task of separate cultivation of each target species. As such, the CE-SSCP-PCR method, that we have developed, has the potential to diagnose pathogens rapidly, unlike the traditional technique, in order to prevent foodborne illness in a much more efficient manner.

전악 치근단 방사선사진 촬영시 촬영조건에 따른 흡수선량 변화에 대한 연구 (COMPARISON OF ABSORBED DOSES RESULTING FROM VARIOUS INTRAORAL PERIAPICAL RADIOGRAPHY)

  • 강미애;박태원
    • 치과방사선
    • /
    • 제25권2호
    • /
    • pp.297-308
    • /
    • 1995
  • This study was designed to measure the absorbed dose to organs of special interest from full mouth with intraoral film(l4 films) and to compare the five periapical techniques. Thermoluminescent crystals(TLD-100 chip) were located in brain, orbit, bone marrow of mandibular ramus, bone marrow of mandibular body, bone marrow of 4th cervical spine, parotid gland, submandibular gland and thyroid gland. X -ray machine was operated at 70kVp and round collimating film holding device(XCP) and rectangular collimating film holding device(Precision Instrument) were used. The distance from the X-ray focus to the open end of the collimator was 8 inch, 12 inch and 16 inch. The results were as follows : 1. The absorbed dose was the highest in bone marrow of mandibular body(5.656mGy) and the lowest in brain (0.050mGy). 2. Generally, the lowest absorbed dose was measured from 16 inch cylinder, rectangular collimating film holding device with paralleling technique. But, in bone marrow of mandibular body and the floor of mouth, the highest absorbed dose was measured from 12 inch cylinder, rectangular collimating film holding device with paralleling techniques. 3. Comparing of five intraoral radiographic techniques, it was appeared statistically significant reduction of the absorbed doses measured with rectangular collimating film holding device compared to XCP film holding device (P<0.05). 4. No statistically significant reduction in the absorbed dose was found as cylinder length was changed(P>0.05).

  • PDF