• Title/Summary/Keyword: AE Parameters

Search Result 419, Processing Time 0.024 seconds

Multivariate Congestion Prediction using Stacked LSTM Autoencoder based Bidirectional LSTM Model

  • Vijayalakshmi, B;Thanga, Ramya S;Ramar, K
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.1
    • /
    • pp.216-238
    • /
    • 2023
  • In intelligent transportation systems, traffic management is an important task. The accurate forecasting of traffic characteristics like flow, congestion, and density is still active research because of the non-linear nature and uncertainty of the spatiotemporal data. Inclement weather, such as rain and snow, and other special events such as holidays, accidents, and road closures have a significant impact on driving and the average speed of vehicles on the road, which lowers traffic capacity and causes congestion in a widespread manner. This work designs a model for multivariate short-term traffic congestion prediction using SLSTM_AE-BiLSTM. The proposed design consists of a Bidirectional Long Short Term Memory(BiLSTM) network to predict traffic flow value and a Convolutional Neural network (CNN) model for detecting the congestion status. This model uses spatial static temporal dynamic data. The stacked Long Short Term Memory Autoencoder (SLSTM AE) is used to encode the weather features into a reduced and more informative feature space. BiLSTM model is used to capture the features from the past and present traffic data simultaneously and also to identify the long-term dependencies. It uses the traffic data and encoded weather data to perform the traffic flow prediction. The CNN model is used to predict the recurring congestion status based on the predicted traffic flow value at a particular urban traffic network. In this work, a publicly available Caltrans PEMS dataset with traffic parameters is used. The proposed model generates the congestion prediction with an accuracy rate of 92.74% which is slightly better when compared with other deep learning models for congestion prediction.

An experimental study on triaxial failure mechanical behavior of jointed specimens with different JRC

  • Tian, Wen-Ling;Yang, Sheng-Qi;Dong, Jin-Peng;Cheng, Jian-Long;Lu, Jia-wei
    • Geomechanics and Engineering
    • /
    • v.28 no.2
    • /
    • pp.181-195
    • /
    • 2022
  • Roughness and joint inclination angle are the important factors that affect the strength and deformation characteristics of jointed rock mass. In this paper, 3D printer has been employed to make molds firstly, and casting the jointed specimens with different joint roughness coefficient (JRC), and different joint inclination angle (α). Conventional triaxial compression tests were carried out on the jointed specimens, and the influence of JRC on the strength and deformation parameters was analyzed. At the same time, acoustic emission (AE) testing system has been adopted to reveal the AE characteristic of the jointed specimens in the process of triaxial compression. Finally, the morphological of the joint surface was observed by digital three-dimensional video microscopy system, and the relationship between the peak strength and JRC under different confining pressures has been discussed. The results indicate that the existence of joint results in a significant reduction in the strength of the joint specimen, JRC also has great influence on the morphology, quantity and spatial distribution characteristics of cracks. With the increase of JRC, the triaxial compressive strength increase, and the specimen will change from brittle failure to ductile failure.

Low Skeletal Muscle Mass and Clinical Outcomes in Chronic Obstructive Pulmonary Disease

  • Yong Jun Choi;Hye Jung Park;Jae Hwa Cho;Min Kwang Byun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.86 no.4
    • /
    • pp.272-283
    • /
    • 2023
  • Background: In patients with chronic obstructive pulmonary disease (COPD), decreased muscle mass is a frequently encountered comorbidity in clinical practice. However, the evaluation of muscle mass in patients with COPD in real-world practice is rare. Methods: We retrospectively reviewed the electronic medical records of all patients with COPD who underwent bioelectrical impedance analysis at least once between January 2011 and December 2021 in three hospitals. Then, we analyzed the performance rate of muscle mass measurement in the patients and the correlation between muscle mass, clinical parameters, and COPD prognosis. Results: Among the 24,502 patients with COPD, only 270 (1.1%) underwent muscle mass measurements. The total skeletal muscle mass index was significantly correlated with albumin, alanine transaminase, and creatinine to cystatin C ratio in patients with COPD (r=0.1614, p=0.011; r=0.2112, p=0.001; and r=0.3671, p=0.001, respectively). Acute exacerbation of COPD (AE COPD) was significantly correlated with muscle mass, especially the truncal skeletal muscle mass index (TSMI) in males (r=-0.196, p=0.007). In the multivariate analysis, TSMI and cystatin C were significant risk factors for AE COPD (hazard ratio, 0.200 [95% confidence interval, CI, 0.048 to 0.838] and 4.990 [95% CI, 1.070 to 23.278], respectively). Conclusion: Low muscle mass negatively affects the clinical outcomes in patients with COPD. Despite its clinical significance, muscle mass measurement is performed in a small proportion of patients with COPD. Therefore, protocols and guidelines for the screening of sarcopenia in patients with COPD should be established.

Predicting Migration of a Heavy Metal in a Sandy Soil Using Time Domain Reflectometry (TDR을 이용한 사질토양에서의 중금속 이동 추정)

  • Dong-Ju Kim;Doo-Sung Baek;Min-Soo Park
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.1
    • /
    • pp.109-118
    • /
    • 1999
  • Recently, transport parameters of conservative solutes such as KCl in a porous medium have been successfully determined using time domain reflectometry (TDR) . This study was initiated to Investigate the applicability of TDR technique to monitoring the fate of a heavy metal ion in a sandy soil and the distribution of its concentration along travel distance with time. A column test was conducted in a laboratory that consists of monitoring both resident and flux concentrations of $ZnCl_2$in a sandy soil under a breakthrough condition. A tracer of $ZnCl_2$(10 g/L) was injected onto the top surface of the sample as pulse type as soon as a steady-state condition was achieved. Time-series measurements of resistance and electrical conductivity were performed at 10 cm and 20 cm of distances from the inlet boundary by horizontal-positioning of parallel TDR metallic rods and using an EC-meter for the effluent exiting the bottom boundary respectively. In addition. Zn ions of the effluent were analyzed by ICP-AES. Since the mode and position of concentration detected by TDR and effluent were different, comparison between ICP analysis and TDR-detected concentration was made by predicting flux concentration using CDE model accommodating a decay constant with the transport parameters obtained from the resident concentrations. The experimental results showed that the resident concentration resulted in earlier and higher peak than the flux concentration obtained by EC-meter, implying the homogeneity of the packed sandy soil. A close agreement was found between the predicted from the transport parameters obtained by TDR and the measured $ZnCl_2$concentration. This indicates that TDR technique can also be applied to monitoring heavy metal concentrations in the soil once that a decay constant is obtained for a given soil.

  • PDF

Development of CRS-Korea II and its Application to Setting the Priority of Toxic Chemicals for Local Provinces (개선된 화학물질 우선순위 선정 기법(CRS-Korea II)과 그 활용을 통한 지역별 유독물 우선순위의 도출)

  • Choi Seung Pil;Park Hoa Sung;Lee Dong Soo;Shin Yong Seung;Kim Ye Shin;Shin Dong Chun
    • Environmental Analysis Health and Toxicology
    • /
    • v.20 no.4 s.51
    • /
    • pp.311-325
    • /
    • 2005
  • A chemical ranking and scoring system, CRS - Korea, has recently been developed and proposed to use to prioritize on a screening level the toxic chemicals for monitoring and risk assessment. As CRS-Korea requires rigorous assessments prior to its wide application, an assessment was conducted in this study by examining the contribution of individual parameter score to the final chemical score or ranking. The sensitivity of the system to the default values for various parameters of missing data was also tested. The chemical ranking/score was round to depend primarily on the score of a single parameter, i. e., the chemical release, while toxicity scores show little correlation with the priority Further analysis indicated that the dominating effect of the chemical release results from i) its multiplicative relationship with the other two exposure parameters (biodegradation and persistent) and ii) the fact that a maximum score of 10 was assigned to the chemical release parameter while 5 was assigned for all others. AE the fraction of the data that are missing exceeded $70\%$ for various toxicity parameters at compared to less than $10\%$ for exposure parameters, the sensitivity of the ranking to the default value was not significant (rank correlation coefficient = 0.98) for toxicity parameters. Bated on this assessment, an improved CRS system (CRS - Korea II) was proposed in which the impact of the chemical release was properly adjusted by changing the multiplicative relationship to additive one and the maximum score to 5. Chemical priority was derived for each of 16 provinces by using CRS-Korea II. The chemical priority was found to significantly vary among the provinces. It was concluded that not only the national chemical priority but the local chemical priority should be taken into account in setting the nationwide chemical monitoring and risk assessment strategy.

A Comparison of Acoustic Parameters between Vocal Fold Bowing and Vocal Fold Polyp (궁형성대와 성대폴립 간의 음성 비교)

  • Kang, Young-Ae;Yoon, Yeo-Hoon;Yoon, Kyu-Chul;Seong, Cheol-Jae
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.22 no.1
    • /
    • pp.40-46
    • /
    • 2011
  • Background and Objectives : Vocal fold bowing is an organic voice disorder that is associated with an abnormal structure of the vocal folds whereas vocal fold polyp is a functional voice disorder caused by an abnormal use of the vocal folds. Both types of vocal folds share a common property in that they make one's voice breathy or strained. The purpose of this study is to compare voice from two types of vocal folds and to offer information of clinical importance. Materials and Method: Vocal fold bowing and vocal fold polyp groups consisted of 7 male subjects, respectively. All subjects recorded /a/ in the state of measuring MPT (maximum phonation time), repeating 3 times, by a voice recorder (48 kHz sampling rate; 24 bit quantization). They answered the questions of K-VHI. Time domain parameters (such as perturbation parameters including HNR, Jitter, etc.) were calculated for the whole duration of /a/ and those of the frequency domain were measured in initial 40 ms and stable 40 ms of /a/, respectively. Mann-Whitney V-test was used for the time domain parameters and K-VHI survey, and Wilcoxon signed rank test was applied to the frequency domain parameters (H1, H2, H1-H2). Results: For K-VHI survey and the time domain analysis, there was no significant difference between bowing and polyp group. For frequency domain analysis, H1 and H2 showed a significantly different result between two groups. Vocal fold bowing group has longer duration and lower intensity than that of vocal fold polyp group in the 'aspirated interval', which could be observable prior to ordinary vowel oscillation. Conclusion: Both groups seem to show breathy voice. This could be referred on the basis of the value of H1-H2. The K-VHI survey says that subjects with vocal fold bowing feel more uncomfortable than subjects with vocal fold polyp.

  • PDF

A SPECTROPHOTOMETRIC STUDY ON DISCOLORATION OF RESTORATIVE COMPOSITE RESINS IN COFFEE AND ARTIFICIAL SALIVA (분광광도계를 이용한 커피와 인공타액에서의 수복용 복합레진의 변색에 대한 연구)

  • Eom, Seung-Hee;Cho, Hyo-Sun;Lee, Chung-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.2
    • /
    • pp.530-545
    • /
    • 1996
  • The purpose of this study was to investigate by spectrophotometry the changes in color parameters of composite resins after exposure to distilled water, filtered coffee, and artificial saliva. Five kinds of fine particle composite resin in experiment 1, and six kinds of composite resin in experiment 2 were used. In experiment 1, each group of composite resin was stored in distilled water at $4^{\circ}C$, $50^{\circ}C$, and filtered coffee solution at $4^{\circ}C$, $50^{\circ}C$. And then each specimen was measured by spectrophotometer. Measurements were repeated in 1 hour, 2 hours, 4 hours, 8 hours, 16 hours, 24 hours, and 48 hours. In experiment 2, all specimens of each brand were stored in distilled water at $37^{\circ}C$, artificial saliva not contained mucin at $37^{\circ}C$, and artificial saliva contained mucin at $37^{\circ}C$. All specimens of each brand were measured by spectrophotormeter in 1 week, 2 weeks, 4 weeks, 8 weeks, and up to 12 weeks. The results were as follows : 1. In cold coffee, five of fine particle composite resins showed ${\Delta}E{^*}_{ab}$ values less than 2. However, in hot coffee ${\Delta}E{^*}_{ab}$ values of Amelogen Universal and Prisma TPH were higher than those of Conquest Crystal, ${\AE}$litefil and Z100. 2. Z100 and ${\AE}$litefil had better cleansibility of extrinsic coffee staining than Amelogen Universal, Conquest Crystal and Prisma TPH. 3. In distilled water and artificial saliva not contained mucin, five of fine particle composite resin showed ${\Delta}E{^*}_{ab}$ values less than 2 up to 12 weeks. However, Silux Plus showed higher than ${\Delta}E{^*}_{ab}$ values of fine particle composite resin. 4. As an immersion solution for discoloration experiment, artificial saliva not contained mucin showed similar appearance as distilled water. However, artificial saliva contained mucin had different appearance from the others. 5. In artificial saliva contained mucin, ${\AE}$litefil, Prisma TPH and Z100 showed ${\Delta}E{^*}_{ab}$ values less than 1 up to 12 weeks. However, Silux Plus, Amelogen Universal and Conquest Crystal showed ${\Delta}E{^*}_{ab}$ values more than 1 up to 12 weeks. But, Conquest Crystal showed different characteristics of chromacity difference value(less chromatic) and lightness difference value(lighter) from Silux Plus and Amelogen Universal.

  • PDF

A Study of the Lesional Grade Discrimination Model for Vocal Fold Nodules and Polyps (성대 결절 및 폴립 병변 판별 예측모형에 대한 연구)

  • Park, Soo-Jung;Shim, Hyun-Sup;Chung, Sung-Min;Kim, Han-Soo;Park, Ae-Kyung
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.15 no.2
    • /
    • pp.112-117
    • /
    • 2004
  • Background and Objectives : This study is purposed to investigate the statistically significant discrimination model for predicting vocal fold nodule and polyp's lesional grade, with patients' background data and objective voice evaluation parameters. Materials and Method : The retrospective research was carried out at the Ewha Womans University Hospital. 122 patients' voice examination data had been selected, and lesion screening (Grade I, II, and III) was conducted by 2 ENT specialists, with each patient's vocal fold pictures achieved during the laryngoscopy examination. Results : The Lesional Grade Discrimination Model with which the lesional grade of vocal fold nodules and polyps could be predicted was derived by the ordinal logistic regression analysis (using SPSS 10.0). With this model the lesional grades of 73 out of 122 patients(59.8%) were correctly predicted to their formerly screened ones. Conclusion : This model applied the multivariate approach, which statistically combined these currently used parameters, Jitter, Shimmer, MFR, MPT, and patient's background data such as gender and dysphonia period. It might explain the status of benign lesion of vocal folds, and furthermore expect the physiological function of vocal folds.

  • PDF

The effects of black garlic (Allium satvium) extracts on lipid metabolism in rats fed a high fat diet

  • Ha, Ae Wha;Ying, Tian;Kim, Woo Kyoung
    • Nutrition Research and Practice
    • /
    • v.9 no.1
    • /
    • pp.30-36
    • /
    • 2015
  • BACKGROUD/OBEJECTIVES: The mechanism of how black garlic effects lipid metabolism remains unsolved. Therefore, the objectives of this study were to determine the effects of black garlic on lipid profiles and the expression of related genes in rats fed a high fat diet. MATERIALS/METHODS: Thirty-two male Sqrague-Dawley rats aged 4 weeks were randomly divided into four groups (n=8) and fed the following diets for 5 weeks: normal food diet, (NF); a high-fat diet (HF); and a high-fat diet + 0.5% or 1.5% black garlic extract (HFBG0.5 or HFBG1.5). Body weights and blood biochemical parameters, including lipid profiles, and expressions of genes related to lipid metabolism were determined. RESULTS: Significant differences were observed in the final weights between the HFBG1.5 and HF groups. All blood biochemical parameters measured in the HFBG1.5 group showed significantly lower values than those in the HF group. Significant improvements of the plasama lipid profiles as well as fecal excretions of total lipids and triglyceride (TG) were also observed in the HFBG1.5 group, when compared to the HF diet group. There were significant differences in the levels of mRNA of sterol regulatory element binding protein-1c (SREBP-1c), acetyl-CoA carboxylase (ACC), fatty acid synthase (FAS), and glucose-6-phosphate dehydrogenase (G6PDH) in the HFBG1.5 group compared to the HF group. In addition, the hepatic expression of (HMG-CoA) reductase and Acyl-CoA cholesterol acyltransferase (ACAT) mRNA was also significantly lower than the HF group. CONCLUSIONS: Consumption of black garlic extract lowers SREBP-1C mRNA expression, which causes downregulation of lipid and cholestrol metahbolism. As a result, the blood levels of total lipids, TG, and cholesterol were decreased.

Study of different flexible aeration tube diffusers: Characterization and oxygen transfer performance

  • Hongprasith, Narapong;Dolkittikul, Natchanok;Apiboonsuwan, Kamolnapach;Pungrasmi, Wiboonluk;Painmanakul, Pisut
    • Environmental Engineering Research
    • /
    • v.21 no.3
    • /
    • pp.233-240
    • /
    • 2016
  • The research aims to study the different flexible rubber tube diffusers used in urban wastewater treatment processes and aquaculture systems. The experiment was conducted in small-scale aeration tank with different physical properties of the tubes that were used as aerators. The volumetric mass transfer coefficient ($k_La$), oxygen transfer efficiency (OTE) and aeration efficiency (AE) were measured and determined to compare the diffusers. Moreover, the bubble hydrodynamic parameters were analyzed in terms of bubble diameter ($d_B$) and rising velocity ($U_B$) by a high speed camera (2,000 frames/s). Then the interfacial area (a) and liquid-side mass transfer coefficient ($k_L$) can be calculated. The physical properties (tube wall thickness, tensile strength, orifice size, hardness and elongation) have been proven to be the key factor that controls the performance (kLa and OTE). The effects of hardness and elongation on bubble formation, orifice size and a-area were clearly proved. It is not necessary to generate too much fine bubbles to increase the a-area: this relates to high power consumption and the decrease of the kL. Finally, the wall thickness, elongation and hardness associated of the flexible tube diffuser (tube No. 12) were concluded, to be the suitable properties for practically producing, in this research.