• Title/Summary/Keyword: ACR팬텀

Search Result 18, Processing Time 0.018 seconds

Analysis of the Dental Implants MRI Artifacts by Using the ACR Phantom (ACR 팬텀을 이용한 치아 임플란트 자기공명영상 인공물 분석)

  • Shin, Woon-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.629-635
    • /
    • 2016
  • ACR phantom for quality control of magnetic resonance imaging equipment can evaluate magnetic resonance imaging picture quality through various structures within the phantom. In this study, percent Signal Ghosting and Slice position accuracy of imaging could be analyzed by attaching implant and the wire for correction of tooth using ACR phantom in Head coil of 3.0T equipment. In the T1 weighted imaging of the first slice and the eleventh slice of implant, the slice position accuracy appeared to be good in ingress bandwidth 300, and it was good in ingress bandwidth 130 when wire for correction was attached. Percent Signal Ghosting in the seventh slice of SE T1 weighted imaging, implant and wire for correction added all appeared to be good when ingress bandwidth was 230. It is thought that in case of implant dental prosthesis patients in brain exam using magnetic resonance imaging, optimum image can be obtained by changing ingress bandwidth.

Evaluation of the Noise Power Spectrum by Using American College of Radiology Phantom for Magnetic Resonance Imaging (자기공명영상에서 ACR 팬텀을 이용한 잡음전력스펙트럼 평가)

  • Jung-Whan Min;Hoi-Woun Jeong
    • Journal of radiological science and technology
    • /
    • v.47 no.1
    • /
    • pp.21-28
    • /
    • 2024
  • This study was purpose to quantitative evaluation of comparison of the image intensity uniformity and noise power spectrum (NPS) by using American college of radiology (ACR) phantom for magnetic resonance imaging (MRI). The MRI was used achiva 3.0T MRI and discovery MR 750, 3.0T, the head and neck matrix shim SENSE head coil were 32 channels receive MR coil. The MRI was used parameters of image sequence for ACR standard and general hospital. NPS value of the ACR standard T2 vertical image in GE equipment was 7.65E-06 when the frequency was 1.0 mm-1. And the NPS value of the ACR hospital T1 region of interest (ROI) 9 over all vertical image in Philips equipment was 9E-08 when the frequency was 1.0 mm-1 and the NPS value of the hospital T2 ROI 9 over all vertical image in Philips equipment was 1.06E-07 when the frequency was 1.0 mm-1. NPS was used efficiently by using a general hospital vertical sequence more than the standard vertical sequence method by using the ACR phantom. Furthermore NPS was the quantitative quality assurance (QA) assessment method for noise and image intensity uniformity characteristics was applied mutatis mutandis, and the results values of the physical imaging NPS of the 3.0T MRI and ACR phantom were presented.

Evaluation of Image Quality according to Insert Position and Thickness Change by Fabricating Modified ACR Phantom in Mammography (유방엑스선검사에서의 변형된 ACR 팬텀 제작을 통한 모조병소의 위치와 두께 변화에 따른 영상의 품질 평가)

  • Uhm, Hyon-Ja;Park, Chanrok
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.103-109
    • /
    • 2022
  • To maintain improved image quality in mammography, the quality control process is performed using the ACR (American college of radiology) phantom. In addition, many studied were performed by fabricating the customized breast phantom to provide more information in mammography. Thus, the purpose of this study was to evaluate the image quality by designing the modified ACR phantoms. The five modified acrlylic ACR phantoms were designed by considering insert position and phantom thickness. The phantoms were consisted of 4.5, 3.0, and 1.5 cm in terms of phantom thickness, and 3.0, 2.0, and 0.5 cm in terms of insert position, respectively. The acquired images were evaluated by PSNR (peak signal to noise ratio), RMSE (root mean square error), CC (correlation coefficient), CNR (contrast to noise ratio), and COV (coefficient of variation). Based on the similarity analysis, the result is suitable between conventional and new designed phantoms. In addition, the CNR and COV results in terms of insert position showed that image quality for 0.5 cm was 2.3 and 27.4% improved compared with 2 and 3 cm, respectively. According to phantom thickness results, the CNR result for 1.5 cm and COV result for 4.5 cm were 50.1 and 62.7% improved compared with that those conditions. In conclusion, we confirmed that the image quality depends on the breast size and thickness through modified ACR phantom study.

Evaluation of the Resolution Characteristics by Using American College of Radiology Phantom for Magnetic Resonance Imaging (자기공명영상에서 ACR 팬텀을 이용한 해상력 특성 평가)

  • Min, Jung-Whan;Jeong, Hoi-Woun;Han, Ji-Hyun;Lee, Si-Nae;Kim, Min-Ji;Kim, Seung-Chul
    • Journal of radiological science and technology
    • /
    • v.45 no.1
    • /
    • pp.11-17
    • /
    • 2022
  • This study was purpose to quantitative assessment of the resolution characteristics by using American college of radiology(ACR) phantom for magnetic resonance imaging (MRI). The MRI equipment was used (Achiva 3.0T MRI, Philips system, Netherlands) and the head/neck matrix shim SENSE head coil were 32 channels(elements) receive MR coil. And the MRI equipment was used (Discovery MR 750, 3.0T MRI, GE medical system, America) and the head/neck matrix shim MC 3003G-32R 32-CH head coil were receive MR coil. As for the modulation transfer function(MTF) comparison result by using ACR magnetic resonance imaging phantom, the MTF value of the ACR standard T2 image in GE equipment is 0.199 when the frequency is 1.0 mm-1 and the MTF value of the hospital T2 image in Philips equipment is 0.528. It was used efficiently by using a general sequence more than the standard sequence method using the ACR phantom. In addition it is significant that the quantitative quality assurance evaluation method for resolution characteristics was applied mutatis mutandis, and the result values of the physical image characteristics of the 3.0T MRI device were presented.

A Study on the Application of Deep Learning Model by Using ACR Phantom in CT Quality Control (CT 정도관리에서 ACR 팬텀을 이용한 딥러닝 모델 적용에 관한 연구)

  • Eun-Been Choi;Si-On Kim;Seung-Won Choi;Jae-Hee Kim;Young-Kyun Kim;Dong-Kyun Han
    • Journal of radiological science and technology
    • /
    • v.46 no.6
    • /
    • pp.535-542
    • /
    • 2023
  • This study aimed to implement a deep learning model that can perform quantitative quality control through ACTS software used for quantitative evaluation of ACR phantom in CT quality control and evaluate its usefulness. By changing the scanning conditions, images of three modules of the ACR phantom's slice thickness (ST), low contrast resolution (LC), and high contrast resolution (HC) were obtained and classified as ACTS software. The deep learning model used ResNet18, implementing three models in which ST, HC, and LC were learned with epoch 50 and an integrated model in which three modules were learned with Epoch 10, 30, and 50 at once. The performance of each model was evaluated through Accuracy and Loss. When comparing and evaluating the accuracy and loss function values of the deep learning models by ST, LC, and HC modules, the Accuracy and Loss of the HC model were the best with 100% and 0.0081, and in the integrated model according to the Epoch value, Accuracy and Loss with epoch 50 were the best with 96.29% and 0.1856. This paper showed that quantitative quality control is possible through a deep learning model, and it can be used as a basis and evidence for applying deep learning to the CT quality control.

Comparative Analysis of Cartesian Trajectory and MultiVane Trajectory Using ACR Phantom in MRI : Using Image Intensity Uniformity Test and Low-contrast Object Detectability Test (ACR 팬텀을 이용한 Cartesian Trajectory와 MultiVane Trajectory의 비교분석 : 영상강도 균질성과 저대조도 검체 검출률 test를 사용하여)

  • Nam, Soon-Kwon;Choi, Joon-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.1
    • /
    • pp.39-46
    • /
    • 2019
  • This study conducted a comparative analysis of differences between cartesian trajectory in a linear rectangular coordinate system and MultiVane trajectory in a nonlinear rectangular coordinate system axial T1 and axial T2 images using an American College of Radiology(ACR) phantom. The phantom was placed at the center of the head coil and the top-to-bottom and left-to-right levels were adjusted by using a level. The experiment was performed according to the Phantom Test Guidance provided by the ACR, and sagittal localizer images were obtained. As shown in Figure 2, slices # 1 and # 11 were scanned after placing them at the center of a $45^{\circ}$ wedge shape, and a total of 11 slices were obtained. According to the evaluation results, the image intensity uniformity(IIU) was 93.34% for the cartesian trajectory, and 93.19% for the MultiVane trajectory, both of which fall under the normal range in the axial T1 image. The IIU for the cartesian trajectory was 0.15% higher than that for the MultiVane trajectory. In axial T2, the IIU was 96.44% for the cartesian trajectory, and 95.97% for the MultiVane trajectory, which fall under the normal range. The IIU for the cartesian trajectory was by 0.47% higher than that for the MultiVane trajectory. As a result, the cartesian technique was superior to the MultiVane technique in terms of the high-contrast spatial resolution, image intensity uniformity, and low-contrast object detectability.

Suggestion of The Manual Exposure Condition Guideline for Reducing Patient Dose in Digital Breast Tomosynthesis (디지털 유방단층촬영의 피폭선량 경감을 위한 수동 촬영조건의 가이드라인 제시)

  • Hong, Eun-Ae;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.483-491
    • /
    • 2016
  • The conditions after exposure to digital mammography and digital breast tomosynthesis were analyzed. The examinations for the ACR phantom were done using manual exposure, not auto exposure, to examine image discrimination and patient dose. As a result, the following results were derived: In the CC exposure, the kVp was 2kVp higher while mAs decreased to 58.6% for the 3D tomography. Such result showed an approximate decrease of 60mAs. At that time, the patients' Average Glandular Dose (AGD) was 1.65mGy in 2D and 1.87mGy in 3D; thus, AGD of 3D was shown to have about 1.13times higher. The result of the manual exposure revealed a reduced mAs of up to 80%; there was no effect in the assessment standard in terms of image discrimination, resulting in more than 10 points. When mAs was reduced to 80% in the manual exposure for ACR phantom, AGD was decreased to 0.66mGy. The diagnostic values of images were maintained and patients dose was reduced in the manual exposure in the AEC condition for 3D. Since the use of 3D has recently increased, using the manual exposure has been recommended in this study to improve the diagnostic value, while, simultaneously reducing patients dose.

A Effectiveness of Multi-Transmit Parallel Technique on Magnetic Resonance Imaging of FOV Less Than 26cm (자기공명영상검사 시 26cm 이하 영상영역의 Multi-Transmit 기법의 유용성)

  • Son, Soon-Yong;Choi, Kwan-Woo;Park, Kyeong-Jin;Lee, Jong-Seok;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.429-435
    • /
    • 2015
  • The purpose of this study was to prospectively estimate the effectiveness of multi-transmit parallel technique in reduced FOV(Field of View) less than 26 cm. Homogeneity, SNR(signal to noise ratio) and acquisition time were measured and compared by setting FOV less than 26cm on the T1 and T2 weighted images using ACR phantom. The multi-transmit parallel technique resulted in significantly faster image acquisition by 46.8 % in T1 weighted images and 18.9% in T2 weighted images. The homogeneity and SNR values had no significant difference between pre and post application of the multi-transmit parallel technique. In conclusion, this study demonstrates the feasibility of multi-transmit parallel technique in FOV less than 26cm with a rapid acquisition and maintained image quality.

A Comparative Study on Image Quality of Breast Image Tests using ACR Phantom (ACR 팬텀을 이용한 시스템별 유방검사 영상의 비교 연구)

  • Hong, Dong-Hee;Jung, Hong-Ryang;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.241-247
    • /
    • 2006
  • Recently, interests and utilization on Computed Radiography(CR) and Digital Radiography(DR) tends to increase owing to an introduction of Picture Archiving and Communication System(PACS) and an accuracy control of special medical equipment for a breast imaging examination. This study was intended to compare and analyze a detector's imaging quality by each system to be used for the breast imaging examination by using ACR Phantom used at the accuracy control. As an evaluation method, a significance and reliability of image's value using the ACR Phantom was analyzed by using SPSS program. The results are followed. 1. For the fiber, there was 3.9 score in Screen-Film, 4.2 score in CR($50{\mu}m$), 3.2 score in CR($100{\mu}m$), and 4.2 score in DR. There was the high score in the order of CR($50{\mu}m$), DR, Screen-Film, and CR($100{\mu}m$)(P<0.05). 2. For the calcification, there was 2.7 score in Screen-Film, 2.5 score in CR($50{\mu}m$), 2.0 score in CR($100{\mu}m$), and 2.9 score in DR. There was the high score in the order of DR, Screen-Film, CR($50{\mu}m$), and CR($100{\mu}m$).(0.025(P<0.05). 3. For Mass, there was 3.8 score in Screen-Film, 3.8 score in CR($50{\mu}m$), 3.6 score in CR($100{\mu}m$), and 4.5 score in DR. There was the high score in the order of DR, CR($50{\mu}m$), Screen-Film, and CR($100{\mu}m$) (P<0.1). 4. As the total score, there was 10.4 score in Screen-Film, 10.6 score in CR($50{\mu}m$), 8.7 score in CR($100{\mu}m$), and 11.3 score in DR. There was the high score in the order of DR, $CR(50{\mu}m$), Screen-Film, and $CR(100{\mu}m$). As shown in the above results, it can be known that DR and Screen-Film System has higher image quality than CR. But, DR has unstability caused by element, and Screen-Film has the low image quality caused by artifact as disadvantages. When Dual-Side CR($50{\mu}m$) was used among CR systems which had the problem of low image quality, it was indicated that there was no difference with Screen-Film System. Because the radiation imaging examination tends to become digitalized, each system for the breast imaging examination will need to be developed and supplemented.

  • PDF

Effect of Antibacterial Film Containing Silver Ions on MRI (은(Ag)이온이 함유된 항균필름이 MRI에 미치는 영향)

  • Shin, Byeong Geun;Kim, Seong Hu;Ahn, Seong Min
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.219-224
    • /
    • 2021
  • The purpose of these experiments is often to scan infected patients with MRI. Therefore, it is to investigate whether the antibacterial film containing silver ions, which is a non-magnetic substance, affects magnetic resonance imaging. In this experiment, the ACR phantom was used, not the patient. The ACR phantom was wrapped in an antibacterial film and the SNR, CNR, sagittal localization image, and geometrical accuracy were compared before and after. The experiment was performed 10 times and the averaged values were compared. There were no significant differences in the results of all experiments. The FDA recommends removing metal and antibacterial film masks during MRI scans. The reason is that there was one case of injury with facial burns. When I touched the antibacterial film to check the fever during the 2 hour experiment, I did not feel any particular fever. In light of the experimental results, it would be helpful to use an antibacterial film when testing an infected patient. The reason is that there isn't a difference before and after the experiment of SNR, CNR, and sagittal localization images.