• Title/Summary/Keyword: ACPD

Search Result 17, Processing Time 0.027 seconds

Determinants of Corporate Anti-Corruption Practice Disclosure: Evidence from Chinese Firms

  • Yin, Hong;Zhang, Ruonan
    • The Journal of Industrial Distribution & Business
    • /
    • v.10 no.3
    • /
    • pp.7-16
    • /
    • 2019
  • Purpose - The purpose of this paper is to investigate the determinants of corporate anti-corruption practice disclosure (ACPD) from the perspective of rent-seeking theory. Research design, data, and methodology - Data are hand-collected from corporate social responsibility reports (CSRR) issued by 724 A-share listed firms in China. This paper provides an empirical analysis of the relationship between ownership structure and corporate ACPD as well as its moderating role in the institutional environment. Results - Our findings indicate that rent-seeking is a key factor in influencing corporate ACPD. State-owned enterprises disclose significantly more anti-corruption information than private ones in order to achieve personal promotion of top executives. Monopoly enterprises reported significantly less anti-corruption information than enterprises in competitive industries due to their rent-seeking behavior. The reduction of government intervention and improvement of legal environment are helpful to curb corporate rent-seeking activities and enhance the level of corporate ACPD. Conclusions - Rent-seeking is an important factor in explaining corporate voluntary disclosure in emerging countries. Institutional environment also plays a moderating role in the relationship between ownership structure and corporate voluntary disclosure. Our results are of interest to policy makers, regulators and market participants that are interested in corporate voluntary disclosure and corruption prevention.

The Nature of Controlling Shareholders, Political Background and Corporate Anti-Corruption Practice Disclosure

  • Yin, Hong;Zhang, Ruonan
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.6 no.1
    • /
    • pp.47-58
    • /
    • 2019
  • The purpose of this paper is to examine the relationship between the nature of controlling shareholders and corporate anti-corruption practice disclosure (ACPD) as well as the mediating role of political background of the chairman or CEO of the firm on the relationship between the two. The content analysis was conducted to extract ACPD from standalone corporate social responsibility reports (CSRR) of 703 China's A-share listed companies. A dummy variable was constructed according to whether a firm disclosed ACPD or not. Logistic regression analysis was used then. Results show that the nature of controlling shareholders has a significant impact on corporate ACPD, with central enterprises disclosing the most frequently, local state-owned enterprises the second and private enterprises the least. Political background of the chairman or CEO has a negative impact on corporate ACPD of state-owned enterprises. These findings have some useful insights in understanding the rent-seeking behavior and information disclosure behavior of corporates in emerging markets. In order to curb the serious corruption problem which is commonplace in developing countries like China, the government should exert certain pressure to strengthen the supervision of information disclosure of listed firms and improve information transparency.

Effective Way of Measuring $K_I$ by Means of ACPD Technique (교류전위차법을 이용한 효과적인 응력확대계수의 측정 방법)

  • Lee, Jeong-Hee
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.1
    • /
    • pp.8-15
    • /
    • 1999
  • In order to develop an effective way of measuring the mode I stress intensity factor, $K_I$, by the technique based on the alternating current potential drop (ACPD), the effect of the magnetic flux in the air on the change in potential drop due to load for both ferromagnetic and paramagnetic materials containing a two-dimensional surface crack was investigated. Additionally the effects of the demagnetization and the crack length on the change in potential drop were examined. In the case that the measuring system was designed to induce a large amount of electromotive force, the amount of the change in potential drop due to load was shown to increase largely Also the relationship between the change in potential drop and that in $K_I$ was indicated to be linear without any treatment and it was shown that the demagnetization had almost no effect on the change in potential drop. The change in potential drop did not depend on the crack length but on the measuring system. For the application of the ACPD technique to determine $K_I$.

  • PDF

Analysis of Adaptive Cycle Packet Drop and Non-Adaptive Cycle Packet Drop for Congestion Control in Internet (인터넷에서 혼잡제어를 위한 적응적 사이클 패킷 폐기 기법과 비적응적 사이클 패킷 폐기 기법의 분석)

  • Kim, Su-Yeon;Kahng, Hyun-Kook
    • The KIPS Transactions:PartC
    • /
    • v.9C no.5
    • /
    • pp.783-788
    • /
    • 2002
  • Adaptive Cyclic Packet Dropping algorithm (ACPD), and Non-adaptive Cyclic Packet Dropping algorithm (NCPD) are applying stricter drop precedence than that of RIO algorithm. Especially, the ACPD algorithm drops adaptively packets for the congestion control, as predicting traffic pattern between each cycle. Therefore the ACPD algorithm makes up for the drawback of RIO algorithm and minimizes the wastes of the bandwidth being capable of predicting in the NCPD algorithm. And we executed a simulation and analyzed the throughput and packet drop rate based on Sending Priority changing dynamically depending on network traffic. In this algorithm, applying strict drop precedence policy, we get better performance on priority levels. The results show that the proposed algorithms may provide more efficient and stricter drop precedence policy as compared to RIO independent of traffic load. The ACPD algorithm can provide better performance on priority levels and keep stricter drop policy than RIO and the NCPD algorithm.

Electromagnetic Analysis of ACPD Method Using Eddy Current Induction (와전류를 이용한 교류전위강하법의 전자기적 해석)

  • Lim, Geon-Gyu;Lee, Hyang-Beom;Lee, Dal-Ho
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.231-234
    • /
    • 2007
  • 와전류를 이용한 전위강하법은 시험체에 와전류를 비 접촉식으로 발생 시킬 수 있어 기존의 방식에 비해 결함 검출시 발생하는 오차를 줄일 수 있고 물체의 결함 검출신호의 신뢰성을 향상 시킬 수 있다. 본 논문에서는 와전류를 이용한 전위강하법의 전자기 유한요소해석을 수행하였다. 3차원 유한요소해석과정에서 해석시간을 단축시키기 위해 각 영역별로 MVP, ESP, RMSP, TMSP의 미지수 변수를 부여하여 유한요소해석을 수행하였다. 기존의 전위강하법에 와전류의 개념을 적용하기 위해서 주파수에 대한 결함 깊이의 영향과 결함에 대한 주파수에 대한 영향을 검토해본 결과 결함의 깊이가 깊어질수록 또한 높은 주파수에서 신호의 크기가 선형적으로 증가하는 패턴을 보였다. 연구결과 와전류를 이용하여 ACPD법을 시행할 경우 데이터 처리 과정과 실험 장비를 단순화 시킬 수 있어 결함 검사를 손쉽게 할 수 있을 것이라 예상된다.

  • PDF

Comparison and Analysis of Cycling Packet Drop Algorithms and RIO as Packet Drop for the Congestion Control (혼잡제어용 패킷 폐기를 위한 사이클링 패킷 폐기 기법과 RIO 알고리즘의 비교 분석)

  • Kim, Su-Yeon;Gang, Hyeon-Guk
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.39 no.2
    • /
    • pp.59-68
    • /
    • 2002
  • In this paper, we compared and analyzed two new models of cyclic packet dropping algorithm, Adaptive Cyclic Packet Dropping algorithm (ACPD), and Non-adaptive Cyclic Packet Dropping algorithm (NCPD) with RIO. The ACPD algorithm drops adaptively packets for the congestion control, as predicting traffic pattern between each cycle. Therefore the ACPD algorithm makes up for the drawback of RIO algorithm and minimizes the wastes of the bandwidth being capable of predicting in the NCPD algorithm. We modelled two cyclic packet drop algorithms and executed a simulation and analyzed the throughput and packet drop rate based on Sending Priority changing dynamically depending on network traffic. In this algorithm, applying the strict drop precedence policy, we get better performance on priority levels. The results show that two new algorithms may provide more efficient and stricter drop precedence policy as compared to RIO independent of traffic load. The ACPD algorithm can provide better performance on priority levels and keep stricter drop policy than other algorithms.

Loading Effect on ACPD of a Crack in Paramagnetic Material (균열을 가진 상자성체의 교류전위차에 미치는 하중의 영향)

  • Lee, Jeong-Hee
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.1
    • /
    • pp.1-7
    • /
    • 1999
  • In order to determine the mode I stress intensity factor ($K_I$) by means of the alternating current potential drop(ACPD) technique, the change in potential drop due to load for a paramagnetic material containing a two-dimensional surface crack was examined. The cause of the change in potential drop and the effects of the magnetic flux and the demagnetization on the change in potential drop were clarified by using the measuring systems with and without removing the magnetic flux from the circumference of the specimen. The change in potential drop was linearly decreased with increasing the tensile load and was caused by the change in conductivity near the crack tip. The reason of decreasing the change in potential drop with increasing the tensile load was that the increase of the conductivity near the crack tip due to the tensile load caused the decreases of the resistance and internal inductance of the specimen The relationship between the change in potential drop and the change in $K_I$ was not affected by demagnetization and was independent of the crack length.

  • PDF

Modulation of Amygdala Synaptic Transmission by Metabotropic Glutamate Receptors

  • Kim, Jung-Hyun;Park, Eun-Jin;Chang, Duk-Jin;Choi, Suk-Woo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.7 no.6
    • /
    • pp.303-306
    • /
    • 2003
  • Metabotropic glutamate receptors (mGluRs), classified into three groups (group I, II, III), play a critical role in modulation of synaptic transmission at central and peripheral synapses. In the present study, extracellular field potential recording techniques were used to investigate effects of mGluR agonists on excitatory synaptic transmission at thalamic input synapses onto the lateral amygdala. The non-selective mGluR agonist t-ACPD ($100{\mu}M$) produced reversible, short-term depression, but the group III mGluR agonist L-AP4 ($50{\mu}M$) did not have any significant effects on amygdala synaptic transmission, suggesting that group I and/or II mGluRs are involved in the modulation by t-ACPD. The group I mGluR agonist DHPG ($100{\mu}M$) produced reversible inhibition as did t-ACPD. Unexpectedly, the group II mGluR agonist LCCG-1 ($10{\mu}M$) induced long-term as well as short-term depression. Thus, our data suggest that activation of group I or II mGluRs produces short-term, reversible depression of excitatory synaptic transmission at thalamic input synapses onto the lateral amygdala. Considering the long-term effect upon activation of group II mGluRs, lack of long-term effects upon activation of group I and II mGluRs may indicate a possible cross-talk among different groups of mGluRs.

Theoretical Analysis of Change in Magnetic Flux Density Due to Load for Measuring KI (응력확대계수측정을 위한 하중에 의한 자속밀도변화의 이론적 해석)

  • Lee, Jeong-Hee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.6 no.4
    • /
    • pp.367-371
    • /
    • 2003
  • In order to determine the effective way of measuring the Mode I stress intensity factor for a material containing a two-dimensional surface crack by means of the alternating current potential drop(ACPD) technique, the change in magnetic flux density between crack surfaces and above the specimen surface due to load was studied theoretically. The magnetic flux density in the air between crack surfaces is uniform and above the specimen surface is not changed by increasing the load in the material. Therefore, the change in potential drop due to load in a measuring system which was designed to induce a large amount of electro-motive force was caused by the change in internal inductance of material, the change in the mutual inductance between internal inductance of material and measuring system and the change in the mutual inductance between internal inductance of material and power supply line.

  • PDF

Experimental Research of Change in Magnetic Flux Density Due to Load for Measuring KI (응력확대계수측정을 위한 하중에 의한 자속밀도변화의 실험적 연구)

  • Lee, Jeong-Hee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.7 no.1
    • /
    • pp.129-132
    • /
    • 2004
  • In order to determine the effective way of measuring the Mode I stress intensity factor, $K_I$, by means of the alternating current potential drop(ACPD) technique for a material containing a two-dimensional surface crack, the change in magnetic flux density above the cracked specimen surface was studied experimentally. The change in magnetic flux in the air above the cracked specimen made of aluminum alloy is measured by changing the load by four-point bending. The magnetic flux in the air is almost not changed by increasing the load in teh specimen. The change in potential drop due to load is not caused by the change in electro-motive force induced in the coiled measuring system. This experimental result agree to the result of theoretical analysis in reference 7).

  • PDF