• Title/Summary/Keyword: ACOUSTIC TOMOGRAPHY

Search Result 53, Processing Time 0.027 seconds

Numerical Experiments of Ocean Acoustic Tomography in the East Sea of Korea

  • Han, Sang-Kyu;Na, Jung-Yul;Lee, Jae-Hak
    • Journal of the korean society of oceanography
    • /
    • v.31 no.2
    • /
    • pp.64-74
    • /
    • 1996
  • Numerical experiments of OAT (Ocean Acoustic Tomography) are carried out in the East Sea of Korea where the canonical ocean has been perturbed by a mesoscale warm eddy and a thermal front. In order to estimate the horizontal and vertical structure of water temperature of the perturbed ocean, the experimental area is divided into 16 cells with 8 pairs of sources and receivers for a horizontal slice and the water column is divided into 8 layers for a vertical slice. The inversely estimated temperature field by using SVD (Singular Value Decomposition) method reveals the eddy and frontal structure clearly. The rms errors of the two horizontal slices are less than $0.4^{\circ}C$ and $1.7^{\circ}C$ at 400 m and 200 m depths, respectively, while the error in the vertical slice is less than $1.0^{\circ}C.$ For better estimation of temperature by OAT method, particularly for the East Sea, a range-dependent ray model should be used to solve the forward problem. At the same time, improvement in computing the refracted ray path between vertical layers is required to obtain more accurate travel time information. The results of the present experiment give rise to a possibility of application of OAT in remote sensing of the ocean thermal structure.

  • PDF

Temporal Variability of Acoustic Arrivals in the East Sea of Korea Using Tomographic Method (한국 동해에서 토모그래피용 신호를 이용한 음파 도달시간의 시변동성)

  • 오선택;나정열;오택환;박정수;나영남;김영규
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.92-99
    • /
    • 2001
  • To measure temporal variability of long- range transmission in northern part of the East Sea of Korea, low frequency acoustic sources were deployed on the continental shelf 0.4km south of Cape Shultz near the port of Vladivostok during October 1999. The transmissions of the phase modulated signals were recorded by VLA moored on the northern slope of Ulleung-do. The measured signals were processed for the acoustic arrivals and their variability in time. The temporal signal processing involves pulse compression of the phase-encoded signal, time spread and temporal coherence processing. Variability of the ocean sound speed field in time scales of short period seems to be dominated by random fluctuations caused by sound speed perturbation due to the vertical displacements associated with internal waves.

  • PDF

Multi-Parameter Lamb Wave Tomography

  • Choi, Jae-Seung;Kline, Ronald A.
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.1-10
    • /
    • 2000
  • This work shows that it is possible to obtain information about more than one parameter from acoustic field information. A variety of ultrasonic Lamb wave modes were utilized to reconstruct thickness and density of an isotropic plate. An image reconstruction of one parameter (thickness of a plate) was carried out for four cases, i.e., the lowest symmetrical and anti symmetrical modes, and the fastest symmetrical and anti symmetrical Lamb waves among multiple modes. For two parameter reconstructions (thickness and density), the image processing was performed using the lowest symmetrical and antisymmetrical modes simultaneously. In this work, a modified version of algebraic reconstruction technique (ART), which is a form of finite-series expansion method, was employed to reconstruct the ultrasonically computed tomographic images. Results from several sample geometries are presented.

  • PDF

Wavelet-based Time Delay Estimation in Tomographic Signals (웨이브렛을 이용한 해양음향 토모그래피 음파 도달시간 분석)

  • 오선택;조환래;나정열;김대경
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.2
    • /
    • pp.153-161
    • /
    • 2003
  • In this paper, we propose a wavelet-based detection method to identify efficiently the time-delay or multipath channel of ocean acoustic signals due to complex ocean medium and boundary layers. Our proposed method employs wavelet packet transform to analyze the received broadband acoustic signals and applies the matched filter to determine the time region of interest. Also, we present numerical testing that results on both the simulated and real data revealed the efficiency of this method in time-delay estimation and moreover its capability in estimating the time-delay of individual path in multipath channel, in which the arrival patterns are too close to be separated by the matched filter method.

A Study of Combustion Instability Mode in Dual Swirl Gas Turbine Combustor by PLIF and Chemiluminescence Measurement (PLIF 및 자발광 계측을 이용한 이중선회 가스터빈 연소기에서 연소불안정 모드 연구)

  • Choi, Inchan;Lee, Keeman;Juddoo, Mrinal;Masri, A.R.
    • Journal of the Korean Society of Combustion
    • /
    • v.19 no.1
    • /
    • pp.29-38
    • /
    • 2014
  • This paper described an experimental investigations of combustion instability mode in a lean premixed dual swirl combustor for micro-gasturbine system. When such the instability occurs, a strong coupling between pressure oscillations and unsteady heat release excites a self-sustained acoustic wave which results in a loud, annoyed sound and may also lead a structural damage to the combustion chamber. The detailed period of flame behavior and heat release in combustion instability mode have been examined with high speed OH and CH-PLIF system and $CH^*$ chemiluminescence measurement, flame tomography with operated at 10 kHz and 6 kHz each. Experiment results suggest that unstable flame behavior has a specific frequency with 200 Hz and this frequency is accords with about 1/2 sub-harmonic of combustor resonance frequency, not fundamental frequency. This is very interesting phenomenon that have not reported yet from other previous works. Therefore, when a thermo-acoustic instability with Rayleigh criterion occurs, the fact that the period of heat release and flame behavior are different each other was proposed for the first time through this work.

Current measurements by using ocean acoustic tomography of reciprocal sound transmission (쌍방향 음파전파의 해양음향 토모그래피를 이용한 유속측정)

  • 변상경
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06c
    • /
    • pp.491-494
    • /
    • 1998
  • 해양음향 토모그래피는 해수중을 전파하는 음파의 전파시간을 측정하여 이것으로부터 수온 및 유속의 분포를 구하는 새로운 관측기법이다. 해양음향 토모그래피에 의한 실시간 유속측정 시스템을 구축하기 위한 기초실험으로서 해양음향 토모그래피의 유속측정 유효성을 검증하기 위하여 쌍방향 음파전파의 해양음향 토모그래피 실험을 1997년 4월중에 거제도 남쪽해역에서 실시하였다. 실험시의 해양물리 환경을 고찰하고 토모그래피에 의한 유속측정 결과를 초음파 유속계(ADCP)에 의한 유속측정 결과와 비교 분석하였다. 그 결과 토모그래피에 의한 유속측정은 매우 양호하게 나타나, 향후 유속측정법으로 활용성이 크리라 기대되었다.

  • PDF

Acoustic 2-D Full-waveform Inversion with Initial Guess Estimated by Traveltime Tomography (주시 토모그래피와 음향 2차원 전파형 역산의 적용성에 관한 연구)

  • Han Hyun Chul;Cho Chang Soo;Suh Jung Hee;Lee Doo Sung
    • Geophysics and Geophysical Exploration
    • /
    • v.1 no.1
    • /
    • pp.49-56
    • /
    • 1998
  • Seismic tomography has been widely used as high resolution subsurface imaging techniques in engineering applications. Although most of the techniques have been using travel time inversion, waveform method is being driven forward owing to the progress of computational environments. Although full-waveform inversion method has been known as the best method in terms of model resolving power without high-frequency restriction and weak scattering approximation, it has practical disadvantage that it is apt to get stuck in local minimum if the initial guess is far from the actual model and it consumes so much time to calculate. In this study, 2-D full-waveform inversion algorithm in acoustic medium is developed, which uses result of traveltime tomography as initial model. From the application on synthetic data, it is proved that this approach can efficiently reduce the problem of conventional approaches: our algorithm shows much faster convergence rate and improvement of model resolution. Result of application on physical modeling data also shows much improvement. It is expected that this algorithm can be applicable to real data.

  • PDF

The Importance of Septoplasty in The Treatment of Nasal Bone and Grade I Septal Fracture: Estimation with Acoustic Rhinometry (비중격 골절을 동반한 단순 비골 골절의 치료에 있어 비중격 교정술의 중요성: 비강 통기도 검사를 이용한 평가)

  • Kim, Jun-Hyung;Shin, Dong-Woo;Choi, Tae-Hyun;Son, Dae-Gu;Han, Ki-Hwan
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.626-632
    • /
    • 2010
  • Purpose: Nasal bone fractures are often classified as minor injury. However, the incidence of posttraumatic nasal deformity remains alarmingly high. It is because of unnoticed septal fracture. This study was conducted to determine the necessity of septoplasty for patients with nasal bone fracture accompanying grade I septal fractures. Methods: Among 105 patients with nasal bone fractures, 52 who had grade I septal fracture were diagnosed based on physical examination and computed tomography. Patients' age ranged from 14 to 65 years (mean 29.25 years), and 35 were male and 17 female. Patients were divided into 2 groups according to surgical treatment methods: patients who underwent closed reduction only (group 1, n=28) and those who underwent simultaneous closed reduction and septoplasty (group 2, n=24). The treatment outcomes were evaluated by comparing changes in nasal airway volume measured by acoustic rhinometry before the surgery, 3 months and 6 months after the surgery according to the timing of surgical repair and surgical treatment methods. Results: Nasal airway volume increased after the surgery by 17.8% in 3 months after the surgery, 25.2% in 6 months in group 1 and by 22.7% in 3 months, 35.8% in 6 months in group 2. The increase in airway volume after the surgery by 26.3% in 3 months after the surgery, 34.2% in 6 months after the surgery in operation within 1 week after trauma and by 12.1% in 3 months, 22.2% in 6 months after the operation later 1 week after trauma. The difference was statistically significant. Three patients in group 1 complained of intermittent nasal obstruction, two of whom showed a decrease in nasal airway volume by acoustic rhinometry. Conclusion: Most patients with nasal bone fractures accompanying grade I septal fractures have been treated with closed reduction in clinical settings. However, the results of this study suggest that septoplasty be performed after a correct diagnosis of septal fracture is made through comprehensive physical examination and computed tomography. Septoplasty is important to obtain more favorable outcomes and reduce complication.

Transducer Combination for High-Quality Ultrasound Tomography Based on Speed of Sound Imaging (속도 분포 기반 단층촬영을 위한 최적의 트랜스듀서의 조합)

  • Kim, Young Hun;Park, Kwan Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.1
    • /
    • pp.27-34
    • /
    • 2016
  • The type of ultrasound transducer used influences the quality of a reconstructed ultrasound image. This study analyzed the effect of transducer type on ultrasound computed tomography (UCT) image quality. The UCT was modeled in an ultrasound simulator by using a 5 cm anatomy model and a ring-shape 5 MHz 128 transducer array, which considered attenuation, refraction, and reflection. Speed-of-sound images were reconstructed by the Radon transform as the UCT image modality. Acoustic impedance images were also reconstructed by the delay-and-sum (DAS) method, which considered the speed of sound information. To determine the optimal combination of transducers in observation, point-source, flat, and focused transducers were tested in combination as trasmitters and receivers; UCT images were constructed from each combination. The combination of point-source/flat transducer as transmitting and receiving devices presented the best reconstructed image quality. In UCT implementation, the combination of a flat transducer for transmitting and a point transducer for receiving permitted acceptable image quality.

Factors Related to Successful Energy Transmission of Focused Ultrasound through a Skull : A Study in Human Cadavers and Its Comparison with Clinical Experiences

  • Jung, Na Young;Rachmilevitch, Itay;Sibiger, Ohad;Amar, Talia;Zadicario, Eyal;Chang, Jin Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.6
    • /
    • pp.712-722
    • /
    • 2019
  • Objective : Although magnetic resonance guided focused ultrasound (MRgFUS) has been used as minimally invasive and effective neurosurgical treatment, it exhibits some limitations, mainly related to acoustic properties of the skull barrier. This study was undertaken to identify skull characteristics that contribute to optimal ultrasonic energy transmission for MRgFUS procedures. Methods : For ex vivo skull experiments, various acoustic fields were measured under different conditions, using five non-embalmed cadaver skulls. For clinical skull analyses, brain computed tomography data of 46 patients who underwent MRgFUS ablations (18 unilateral thalamotomy, nine unilateral pallidotomy, and 19 bilateral capsulotomy) were retrospectively reviewed. Patients' skull factors and sonication parameters were comparatively analyzed with respect to the cadaveric skulls. Results : Skull experiments identified three important factors related skull penetration of ultrasound, including skull density ratio (SDR), skull volume, and incidence angle of the acoustic rays against the skull surface. In clinical results, SDR and skull volume correlated with maximal temperature (Tmax) and energy requirement to achieve Tmax (p<0.05). In addition, considering the incidence angle determined by brain target location, less energy was required to reach Tmax in the central, rather than lateral targets particularly when compared between thalamotomy and capsulotomy (p<0.05). Conclusion : This study reconfirmed previously identified skull factors, including SDR and skull volume, for successful MRgFUS; it identified an additional factor, incidence angle of acoustic rays against the skull surface. To guarantee successful transcranial MRgFUS treatment without suffering these various skull issues, further technical improvements are required.