• Title/Summary/Keyword: ACCURACY

Search Result 34,318, Processing Time 0.065 seconds

Retrieval of Sulfur Dioxide Column Density from TROPOMI Using the Principle Component Analysis Method (주성분분석방법을 이용한 TROPOMI로부터 이산화황 칼럼농도 산출 연구)

  • Yang, Jiwon;Choi, Wonei;Park, Junsung;Kim, Daewon;Kang, Hyeongwoo;Lee, Hanlim
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.6_3
    • /
    • pp.1173-1185
    • /
    • 2019
  • We, for the first time, retrieved sulfur dioxide (SO2) vertical column density (VCD) in industrial and volcanic areas from TROPOspheric Monitoring Instrument (TROPOMI) using the Principle component analysis(PCA) algorithm. Furthermore, SO2 VCDs retrieved by the PCA algorithm from TROPOMI raw data were compared with those retrieved by the Differential Optical Absorption Spectroscopy (DOAS) algorithm (TROPOMI Level 2 SO2 product). In East Asia, where large amounts of SO2 are released to the surface due to anthropogenic source such as fossil fuels, the mean value of SO2 VCD retrieved by the PCA (DOAS) algorithm was shown to be 0.05 DU (-0.02 DU). The correlation between SO2 VCD retrieved by the PCA algorithm and those retrieved by the DOAS algorithm were shown to be low (slope = 0.64; correlation coefficient (R) = 0.51) for cloudy condition. However, with cloud fraction of less than 0.5, the slope and correlation coefficient between the two outputs were increased to 0.68 and 0.61, respectively. It means that the SO2 retrieval sensitivity to surface is reduced when the cloud fraction is high in both algorithms. Furthermore, the correlation between volcanic SO2 VCD retrieved by the PCA algorithm and those retrieved by the DOAS algorithm is shown to be high (R = 0.90) for cloudy condition. This good agreement between both data sets for volcanic SO2 is thought to be due to the higher accuracy of the satellite-based SO2 VCD retrieval for SO2 which is mainly distributed in the upper troposphere or lower stratosphere in volcanic region.

Comparison of PCR-RFLP and Real-Time PCR for Allelotyping of Single Nucleotide Polymorphisms of RRM1, a Lung Cancer Suppressor Gene (폐암 억제유전자 RRM1의 단일염기다형성 검사를 위한 PCR-RFLP법과 Real-Time PCR법의 유용성 비교)

  • Jeong, Ju-Yeon;Kim, Mi-Ran;Son, Jun-Gwang;Jung, Jong-Pil;Oh, In-Jae;Kim, Kyu-Sik;Kim, Young-Chul
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.5
    • /
    • pp.406-416
    • /
    • 2007
  • Background: Single nucleotide polymorphisms (SNPs), which consist of a substitution of a single nucleotide pair, are the most abundant form of genetic variations occurring with a frequency of approximately 1 per 1000 base pairs. SNPs by themselves do not cause disease but can predispose humans to disease, modify the extent or severity of the disease or influence the drug response and treatment efficacy. Single nucleotide polymorphisms (SNPs), particularly those within the regulatory regions of the genes often influence the expression levels and can modify the disease. Studies examining the associations between SNP and the disease outcome have provided valuable insight into the disease etiology and potential therapeutic intervention. Traditionally, the genotyping of SNPs has been carried out using polymerase chain reaction-restriction fragment length polymorphism(PCR-RFLP), which is a low throughput technique not amenable for use in large-scale SNP studies. Recently, TaqMan real-time PCR chemistry was adapted for use in allelic discrimination assays. This study validated the accuracy and utility of real-time PCR technology for SNPs genotyping Methods: The SNPs in promoter sequence (-37 and -524) of lung cancer suppressor gene, RRM1 (ribonucleotide reductase M1 subunit) with the genomic DNA samples of 89 subjects were genotyped using both real-time PCR and PCR-RFLP. Results: The discordance rates were 2.2% (2 mismatches) in -37 and 16.3% (15 mismatches) in -524. Auto-direct sequencing of all the mismatched samples(17 cases) were in accord with the genotypes read by real-time PCR. In addition, 138 genomic DNAs were genotyped using real-time PCR in a duplicate manner (two separated assays). Ninety-eight percent of the samples showed concordance between the two assays. Conclusion: Real-time PCR allelic discrimination assays are amenable to high-throughput genotyping and overcome many of the problematic features associated with PCR-RFLP.

A Multimodal Profile Ensemble Approach to Development of Recommender Systems Using Big Data (빅데이터 기반 추천시스템 구현을 위한 다중 프로파일 앙상블 기법)

  • Kim, Minjeong;Cho, Yoonho
    • Journal of Intelligence and Information Systems
    • /
    • v.21 no.4
    • /
    • pp.93-110
    • /
    • 2015
  • The recommender system is a system which recommends products to the customers who are likely to be interested in. Based on automated information filtering technology, various recommender systems have been developed. Collaborative filtering (CF), one of the most successful recommendation algorithms, has been applied in a number of different domains such as recommending Web pages, books, movies, music and products. But, it has been known that CF has a critical shortcoming. CF finds neighbors whose preferences are like those of the target customer and recommends products those customers have most liked. Thus, CF works properly only when there's a sufficient number of ratings on common product from customers. When there's a shortage of customer ratings, CF makes the formation of a neighborhood inaccurate, thereby resulting in poor recommendations. To improve the performance of CF based recommender systems, most of the related studies have been focused on the development of novel algorithms under the assumption of using a single profile, which is created from user's rating information for items, purchase transactions, or Web access logs. With the advent of big data, companies got to collect more data and to use a variety of information with big size. So, many companies recognize it very importantly to utilize big data because it makes companies to improve their competitiveness and to create new value. In particular, on the rise is the issue of utilizing personal big data in the recommender system. It is why personal big data facilitate more accurate identification of the preferences or behaviors of users. The proposed recommendation methodology is as follows: First, multimodal user profiles are created from personal big data in order to grasp the preferences and behavior of users from various viewpoints. We derive five user profiles based on the personal information such as rating, site preference, demographic, Internet usage, and topic in text. Next, the similarity between users is calculated based on the profiles and then neighbors of users are found from the results. One of three ensemble approaches is applied to calculate the similarity. Each ensemble approach uses the similarity of combined profile, the average similarity of each profile, and the weighted average similarity of each profile, respectively. Finally, the products that people among the neighborhood prefer most to are recommended to the target users. For the experiments, we used the demographic data and a very large volume of Web log transaction for 5,000 panel users of a company that is specialized to analyzing ranks of Web sites. R and SAS E-miner was used to implement the proposed recommender system and to conduct the topic analysis using the keyword search, respectively. To evaluate the recommendation performance, we used 60% of data for training and 40% of data for test. The 5-fold cross validation was also conducted to enhance the reliability of our experiments. A widely used combination metric called F1 metric that gives equal weight to both recall and precision was employed for our evaluation. As the results of evaluation, the proposed methodology achieved the significant improvement over the single profile based CF algorithm. In particular, the ensemble approach using weighted average similarity shows the highest performance. That is, the rate of improvement in F1 is 16.9 percent for the ensemble approach using weighted average similarity and 8.1 percent for the ensemble approach using average similarity of each profile. From these results, we conclude that the multimodal profile ensemble approach is a viable solution to the problems encountered when there's a shortage of customer ratings. This study has significance in suggesting what kind of information could we use to create profile in the environment of big data and how could we combine and utilize them effectively. However, our methodology should be further studied to consider for its real-world application. We need to compare the differences in recommendation accuracy by applying the proposed method to different recommendation algorithms and then to identify which combination of them would show the best performance.

Improvement of analytical methods for arsenic in soil using ICP-AES (ICP-AES를 이용한 토양 시료 중 비소 분석 방법 개선)

  • Lee, Hong-gil;Kim, Ji In;Kim, Rog-young;Ko, Hyungwook;Kim, Tae Seung;Yoon, Jeong Ki
    • Analytical Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.409-416
    • /
    • 2015
  • ICP-AES has been used in many laboratories due to the advantages of wide calibration range and multi-element analysis, but it may give erroneous results and suffer from spectral interference due to the large number of emission lines associated with each element. In this study, certified reference materials (CRMs) and field samples were analyzed by ICP-AES and HG-AAS according to the official Korean testing method for soil pollution to investigate analytical problems. The applicability of HG-ICP-AES was also tested as an alternative method. HG-AAS showed good accuracies (90.8~106.3%) in all CRMs, while ICP-AES deviated from the desired range in CRMs with low arsenic and high Fe/Al. The accuracy in CRM030 was estimated as below 39% at the wavelength of 193.696 nm by ICP-AES. Significant partial overlaps and sloping background interferences were observed near to 193.696 nm with the presence of 50 mg/L Fe and Al. Most CRMs were quantified with few or no interferences of Fe and Al at 188.980 nm. ICP-AES properly assessed low and high level arsenic for field samples, at 188.980 nm and 193.696 nm, respectively. The importance of the choice of measurement wavelengths corresponding to relative arsenic level should be noted. Because interferences were affected by the sample matrix, operation conditions and instrument figures, the analysts were required to consider spectral interferences and compare the analytical performance of the recommended wavelengths. HG-ICP-AES was evaluated as a suitable alternative method for ICP-AES due to improvement of the detection limit, wide calibration ranges, and reduced spectral interferences by HG.

A Study on Horizontal Reference Planes in Lateral Cephalogram in Korean Children (한국 아동의 측모두부 수평 기준선에 관한 연구)

  • Kim, Kyung-Ho;Choy, Kwang-Chul;Lee, Ji-Yeon
    • The korean journal of orthodontics
    • /
    • v.29 no.2 s.73
    • /
    • pp.251-265
    • /
    • 1999
  • Various types of horizontal reference planes are used for diagnosis, treatment planning and evaluation of treatment results. But these reference Planes lack accuracy and repro-ducibility, and are mainly for Caucasian. Unlike the adult patients who have completed growth, the horizontal reference planes for growing children may change continuously during growth. Therefore this must be considered in selecting the horizontal reference plane. The purpose of this study was to Investigate the angle formed by the Sella-Nasion(SN) plane and Frankfort-Horizontal(FH) plane and evaluate the angle formed by FH plane and other horizontal reference planes in relation to different skeletal maturity and malocclusion types. 540 subjects with no orthodontic treatment history were chosen, and hand -wrist X-rays and lateral cephalometric X-rays were taken. According to SMA(Skeletal Maturity Assessment) of hand-wrist X-rays, the subjects were classified into 3 skeletal maturity groups : SMI 1-4 for group A, SMI 5-7 for group B and SMI 8-11 for group C. A second classification was made according to cephalometric analysis of lateral cephalograms. The subjects were classified into 3 malocclusion groups : Skeletal Class I, II and III malocclusion group. 10 measurements were evaluated. The results were as follows. 1. The angle formed by the SN plane and FH plane showed no difference among skeletal maturity groups, malocclusion groups, and between .sexes. 2. The angles formed by the SN plane and FH plane were $8.27^{\circ}{\pm}2.31^{\circ}$ for males and $8.59^{\circ}{\pm}2.24^{\circ}$ for females. The average value for females and males was $8.42^{\circ}{\pm}2.28^{\circ}$. 3. The angle formed by the FH plane and palatal plane was almost constant showing no difference among skeletal maturity groups, malocclusion groups, and between sexes($1.09^{\circ}{\pm}3.21^{\circ}$).

  • PDF

IN VITRO EVALUATION OF THE CONSISTENCY OF TWO ELECTRONIC APEX LOCATORS (2종 전자근관장측정기의 일관성에 관한 in vitro 연구)

  • Hwang, Gyu-Young;Roh, Byoung-Duck;Kim, Eui-Sung;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.1
    • /
    • pp.20-27
    • /
    • 2008
  • The purpose of this study was to evaluate the consistency of two electronic apex locators in vitro model. Materials consisted of fifty two extracted premolars and two electronic apex locators; Root ZX (J. Morita, Osaka, Japan) and E-Magic Finder Deluxe (S-Denti. Cheonan, Korea). After access preparation, the teeth were embedded in a saline-mixed alginate model. Canal lengths of each tooth were measured at "0.5" and "Apex" mark of the apex locators, respectively so that each tooth had two measurements from 0.5 and Apex points. The file was fixed at final measurement using a glass ionomer cement. The apical 4 mm from the apex was exposed to measure the distance from the file tip to the major apical foramen of each tooth. Average distances and standard deviations were used to evaluate the consistency. Results showed that all measurements of both Root ZX and E-Magic Finder located the major foramen the range of ${\pm}0.5\;mm$ level. Both apex locators showed better consistency at Apex mark than at 0.5 mark. The average distance of file tip-major foramen was - 0.18 mm at 0.5 mark and - 0.07 mm at Apex mark in Root ZX, - 0.25 mm at 0.5 mark and - 0.02 mm at Apex mark in E-Magic Finder. Standard deviation was 0.21 at 0.5 mark and 0.12 at Apex mark in Root ZX, 0.12 at 0.5 mark and 0.09 at Apex mark in E-Magic Finder.

The Role and Efficacy of Diagnostic Laparoscopy to Detect the Peritoneal Recurrence of Gastric Cancer (복막 전이가 의심되는 위암 환자에서 진단적 복강경 검사의 의의와 역할)

  • Song, Sun-Choon;Lee, Sang-Lim;Cho, Young-Kwan;Han, Sang-Uk
    • Journal of Gastric Cancer
    • /
    • v.9 no.2
    • /
    • pp.51-56
    • /
    • 2009
  • Purpose: Peritoneal recurrence has been reported to be the most common form of recurrence of gastric cancer. Peritoneal recurrence can generally be suggested by several types of image studies and also if there is evidence of ascites or Bloomer's rectal shelf. It can be confirmed by explorative laparotomy, but diagnostic laparoscopy is a good alternative method and laparoscopic surgery has also been widely used. We reviewed and analyzed the ability of diagnostic laparoscopy to detect peritoneal recurrence or carcinomatosis, and especially for gastric cancer. Materials and Methods: We performed a retrospective review the 45 gastric cancer patients who were operated via diagnostic laparoscopy between 2004. 2. and 2009. 3. We analyzed the perioperative clinical characteristics and the accuracy of the diagnostic methods. Results: The study groups included 14 patients who had confirmed gastric cancer, but they suspected to have carcinomatosis, and 31 patients who had previously underwent gastric resection, but they suspected to have recurrence. The mean operation time was $44.1\pm26.9$ minutes and the mean postoperative hospital stay was $2.7\pm2.8$ days. There was one case of operation-related complication and no postoperative mortality occurred. The sensitivities for detecting peritoneal recurrence or carcinomatosis were 92.1% for diagnostic laparoscopy, 29.7% for detecting ascites and rectal shelf on the physical examination, 86.5% for abdominal computed tomography, 69.2% for PET CT and 18.8% for CEA. Conclusion: Diagnostic laparoscopy does not require a long operation time or a long hospital stay, and it showed a low complication rate in our study. It has high sensitivity for detecting peritoneal recurrence of gastric cancer. It can be an alternative diagnostic confirmative method and it is useful for deciding on further treatment.

  • PDF

Usefulness of High-B-value Diffusion - Weighted MR Imaging for the Pre-operative Detection of Rectal Cancers (B-values 변환 자기공명영상: 국소 직장암 수술 전 검출을 위한 적합한 b-value 유용성)

  • Lee, Jae-Seung;Goo, Eun-Hoe;Lee, Sun-Yeob;Park, Cheol-Soo;Choi, Ji-Won
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.683-690
    • /
    • 2009
  • The purpose of this study is to evaluate the usefulness of high-b-values diffusion weighted magnetic resonance imaging for the preoperative detection of focal rectum cancers. 60patients with diffusion weighted imaging were evaluated for the presence of rectal cancers. Forty were male and twenty were female, and their ages ranged from 38 to 71 (mean, 56) years. Used equipment was 1.5Tesla MRI((GE, General Electric Medical System, Excite HD). Examination protocols were used the fast spin echo T2, T1 weighted imaging. All examination protocols were performed by the same location with diffusion weighted imaging for accuracy detection. The b-values used in DWI were 250, 500, 750, 1000. 1500, 2000$(s/mm^2)$. The rectum, bladder to tumor contrast-to-noise ratio (CNR) of MR images were quantitativlely analyzed using GE software Functool tool, four experienced radiologists and three radiotechnologists qualitatively evaluated image quality in terms of image artifacts, lesion conspicuity and rectal wall. These data were analysed by using ANOVA and Freedman test with each b-value(p<0.05). Contrast to noise ratio of rectum, bladder and tumor in b-value 1000 were 27.21, 24.44, respectively(p<0.05) and aADC value was $0.73\times10^{-3}$. As a qualitative analysis, the conspicuity and discrimination from the rectal wall of lesions were high results as $4.0\pm0.14$, $4.4\pm0.16$ on b-value 1000(p<0.05), image artifacts were high results as $4.8\pm0.25$ on b-value 2000(p<0.05). In conclusion, DWI was provided useful information with depicting the pre-operative detection of rectal cancers, High-b-value 1000 image was the most excellent DWI value.

(Image Analysis of Electrophoresis Gels by using Region Growing with Multiple Peaks) (다중 피크의 영역 성장 기법에 의한 전기영동 젤의 영상 분석)

  • 김영원;전병환
    • Journal of KIISE:Software and Applications
    • /
    • v.30 no.5_6
    • /
    • pp.444-453
    • /
    • 2003
  • Recently, a great interest of bio-technology(BT) is concentrated and the image analysis technique for electrophoresis gels is highly requested to analyze genetic information or to look for some new bio-activation materials. For this purpose, the location and quantity of each band in a lane should be measured. In most of existing techniques, the approach of peak searching in a profile of a lane is used. But this peak is improper as the representative of a band, because its location does not correspond to that of the brightest pixel or the center of gravity. Also, it is improper to measure band quantity in most of these approaches because various enhancement processes are commonly applied to original images to extract peaks easily. In this paper, we adopt an approach to measure accumulated brightness as a band quantity in each band region, which Is extracted by not using any process of changing relative brightness, and the gravity center of the region is calculated as a band location. Actually, we first extract lanes with an entropy-based threshold calculated on a gel-image histogram. And then, three other methods are proposed and applied to extract bands. In the MER method, peaks and valleys are searched on a vertical search line by which each lane is bisected. And the minimum enclosing rectangle of each band is set between successive two valleys. On the other hand, in the RG-1 method, each band is extracted by using region growing with a peak as a seed, separating overlapped neighbor bands. In the RG-2 method, peaks and valleys are searched on two vertical lines by which each lane is trisected, and the left and right peaks nay be paired up if they seem to belong to the same band, and then each band region is grown up with a peak or both peaks if exist. To compare above three methods, we have measured the location and amount of bands. As a result, the average errors in band location of MER, RG-1, and RG-2 were 6%, 3%, and 1%, respectively, when the lane length is normalized to a unit value. And the average errors in band amount were 8%, 5%, and 2%, respectively, when the sum of band amount is normalized to a unit value. In conclusion, RG-2 was shown to be more reliable in the accuracy of measuring the location and amount of bands.

Development of a Window Program for Searching CpG Island (CpG Island 검색용 윈도우 프로그램 개발)

  • Kim, Ki-Bong
    • Journal of Life Science
    • /
    • v.18 no.8
    • /
    • pp.1132-1139
    • /
    • 2008
  • A CpG island is a short stretch of DNA in which the frequency of the CG dinucleotide is higher than other regions. CpG islands are present in the promoters and exonic regions of approximately $30{\sim}60$% of mammalian genes so they are useful markers for genes in organisms containing 5-methylcytosine in their genomes. Recent evidence supports the notion that the hypermethylation of CpG island, by silencing tumor suppressor genes, plays a major causal role in cancer, which has been described in almost every tumor types. In this respect, CpG island search by computational methods is very helpful for cancer research and computational promoter and gene predictions. I therefore developed a window program (called CpGi) on the basis of CpG island criteria defined by D. Takai and P. A. Jones. The program 'CpGi' was implemented in Visual C++ 6.0 and can determine the locations of CpG islands using diverse parameters (%GC, Obs (CpG)/Exp (CpG), window size, step size, gap value, # of CpG, length) specified by user. The analysis result of CpGi provides a graphical map of CpG islands and G+C% plot, where more detailed information on CpG island can be obtained through pop-up window. Two human contigs, i.e. AP00524 (from chromosome 22) and NT_029490.3 (from chromosome 21), were used to compare the performance of CpGi and two other public programs for the accuracy of search results. The two other programs used in the performance comparison are Emboss-CpGPlot and CpG Island Searcher that are web-based public CpG island search programs. The comparison result showed that CpGi is on a level with or outperforms Emboss-CpGPlot and CpG Island Searcher. Having a simple and easy-to-use user interface, CpGi would be a very useful tool for genome analysis and CpG island research. To obtain a copy of CpGi for academic use only, contact corresponding author.