• 제목/요약/키워드: ACCURACY

검색결과 33,818건 처리시간 0.055초

폐암의 병기결정시 임파절의 조직학적 소견과 전산화단층활영의 정확도에 관한 고찰 (Accuracy of Preoperative Computed Tomography in Comparison with Histopathologic Findings in Staging of Lung Cancer)

  • 박기진;김대영
    • Journal of Chest Surgery
    • /
    • 제29권1호
    • /
    • pp.52-58
    • /
    • 1996
  • Sixty six patients who were operated as lung cancer during the period from Mar. 1991 to Sep. 1993 at the department of Thoracic and cardiovascular surgery, were reviewed retrospectively and the accuracy of regional lymph node in preoperative CT were compared with histopathologlc report obtained from operation. The age ranged from 30 to 72 years old (mean age : 56.5), and 51 patients were male and 15 patients were female. The author analysed the true positive, true negative, false positive and false negative and sensitivity, specificity, positive predictive index, negative predictive index and accuracy of each nodes. The result is that there were differences between seven nodal groups in specificity, sensitivity, positive predictive Index, negative predictive index and accuracy. The range of each nodal group is from 81.7 to 98.3% The nodes of the most poor accuracy are aortopulmonary area and hilar area.

  • PDF

열탈착/GC/FID를 이용한 B, T, X 분석의 정확도 및 정밀도 평가 (A Study on Evaluation of Accuracy and Precision on B, T, X Analysis Using Thermal Desorption/Gas Chromatograph/Flams Ionization Detector)

  • 박정근;유기호
    • 한국대기환경학회지
    • /
    • 제16권3호
    • /
    • pp.265-275
    • /
    • 2000
  • By using thermal desorption/gas chromatograph/flame ionization detector(TD/GC/FID), this study was carried out to evalute an accuracy and a precision on Benzene(B), Toluene(T), o-Xylene(X) analysis in an industrial hygiene laboratory. Limits of detection of TD/GC/FID on B, T, X were showed 13.75ng/sample or less. For the accuracy of the method by concentration levels, overall bias was showed 7.7% as an absolute value, and the pooled coefficient of variation showed 3.51%. For the precision on repeatability of peak area and retention time between within-run and between-run of analytical system, it is showed the results of within-run gave better than those of between-run. Also the accuracy by sorbents(Tenax TA and Chromosorb 106)was evaluated, and the precision on reproducibility between MDHS72 and this study was compared. It is showed it is possible for TD/GC/FID to evaluate accurately B, T, X concentration levels of less than 1ppm at indoor or outdoor of workplaces in Korea.

  • PDF

항공용 전자전장비의 방향탐지 정확도 분석기법 (A Study on Direction Finding Accuracy Analysis for Airborne ESM)

  • 이영중;김인선;박주래
    • 한국군사과학기술학회지
    • /
    • 제11권6호
    • /
    • pp.63-73
    • /
    • 2008
  • The helicopter position, heading data and the direction finding data of ESM are essentially required to compensate the parallax and analyze the direction finding accuracy of heliborne ESM in flight test phase. In the case of the long test range compared with small platform like as LYNX helicopter and Jisim Island test site, the parallax compensation for direction finding accuracy calculation and GPS position error can be neglected. In this paper, the direction finding accuracy on the basis of helicopter propeller was calculated by coordinate changing between helicopter and transmitting antenna from WGS84 coordinate to navigation coordinate using helicopter position and direction finding data.

On the Accuracy of RFID Tag Estimation Functions

  • Park, Young-Jae;Kim, Young-Beom
    • Journal of information and communication convergence engineering
    • /
    • 제10권1호
    • /
    • pp.33-39
    • /
    • 2012
  • In this paper, we compare the accuracy of most representative radio frequency identification (RFID) tag estimation functions in the context of minimizing RFID tag identification delay. Before the comparisons, we first evaluate the accuracy of Schoute's estimation function, which has been widely adopted in many RFID tag identification processes, and show that its accuracy actually depends on the number of tags to be identified and frame size L used for dynamic frame slotted Aloha cycles. Through computer simulations, we show how the accuracy of estimation functions is related to the actual tag read performance in terms of identification delay.

Oil Spill Detection from RADARSAT-2 SAR Image Using Non-Local Means Filter

  • Kim, Daeseong;Jung, Hyung-Sup
    • 대한원격탐사학회지
    • /
    • 제33권1호
    • /
    • pp.61-67
    • /
    • 2017
  • The detection of oil spills using radar image has been studied extensively. However, most of the proposed techniques have been focused on improving detection accuracy through the advancement of algorithms. In this study, research has been conducted to improve the accuracy of oil spill detection by improving the quality of radar images, which are used as input data to detect oil spills. Thresholding algorithms were used to measure the image improvement both before and after processing. The overall accuracy increased by approximately 16%, the producer accuracy increased by 40%, and the user accuracy increased by 1.5%. The kappa coefficient also increased significantly, from 0.48 to 0.92.

협력적 필터링 추천 시스템의 정확도 향상 (Accuracy improvement of a collaborative filtering recommender system)

  • 이석환;박승현
    • 대한안전경영과학회지
    • /
    • 제12권1호
    • /
    • pp.127-136
    • /
    • 2010
  • In this paper, the author proposed following two methods to improve the accuracy of the recommender system. First, in order to classify the users more accurately, the author used a EMC(Expanded Moving Center) heuristic algorithm which improved clustering accuracy. Second, the author proposed the Neighborhood-oriented preference prediction method that improved the conventional preference prediction methods, so the accuracy of the recommender system is improved. The test result of the recommender system which adapted the above two methods suggested in this paper was improved the accuracy than the conventional recommendation methods.

초정밀위치결정을 위한 델타스테이지의 최적 설계 및 컴퓨터 시뮬레이션에 관한 연구 (A Study on the Optimal Structural Design and Computer Simulation of Delta Stage for ultra Precision Positioning)

  • 김재열;김영석;송찬일;곽이구;한재호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.221-225
    • /
    • 2001
  • Recently, high accuracy and high precision are required in various industrial fields that are composed of semiconductor manufacturing apparatus and ultra precision positioning apparatus and information system and so on. The positioning technology is a very important one among them. This technology has been rapidly developed, its field needs for positioning accuracy to high as submicron. It is expected that accuracy with 10 nm in precision working and accuracy with 1 nm in ultra precision working are reached at the beginning of 2000s. Recently, to accomplish this positioning technology, many researches are concerned about it and make efforts it. This paper contain design technology of ultra precision 2-axis(X-Y Delta) stage for materialize to positioning accuracy with submicron, where, Delta stage is design as optimum against load and disturbance. And computer simulation is performed for stability and dynamic characteristic of Delta stage.

  • PDF

엔드밀 가공에서 형상 정밀도 향상을 위한 절삭 조건 선정 (Cutting Condition Selection for Geometrical Accuracy Improvement in End Milling)

  • 류시형;최덕기;주종남
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1784-1788
    • /
    • 2003
  • For the improvement of geometrical accuracy in end milling, cutting method and cutting condition selection are investigated in this paper. As machining processes are composed of several steps such as roughing, semi-finishing. and finishing, cutting forces and tool deflection are calculated considering surface shape generated by the previous cutting. The effects of tool teeth numbers, tool geometry, and cutting conditions on the form error are analyzed. Using the from error prediction method from tool deflection, cutting condition for geometrical accuracy improvement is discussed. The characteristics and the difference of generated surface shape in up and down milling are dealt with and over-cut free condition in up milling is presented. The form error reduction method by alternating up and down milling is also suggested. The effectiveness of the presented method is examined from a set of cutting tests under various cutting conditions. This research contributes to cutting process optimization for the geometrical accuracy improvement in die and mold manufacture.

  • PDF

선박의 조종성능 추정에 있어서 시스템식별법을 이용한 PMM 시험 기법에 대한 연구 (A Study on Practical PMM Test Technique for Ship Maneuverability Using System Identification Method)

  • 이태일;권순홍
    • 한국해양공학회지
    • /
    • 제16권6호
    • /
    • pp.25-31
    • /
    • 2002
  • A system identification method is introduced to increase the prediction accuracy of a ship's maneuverability in PMM test, analysis. To improve the accuracy of linear hydrodynamic coefficients, the analysis techniques of pure sway and yaw tests are developed, and confirmed. In the analysis of sway tests, accuracy to linear hydrodynamic coefficients depends on the frequency of sway motion. To obtain nonlinear hydrodynamic coefficients for large drift angles, a combined yaw test is introduced. Using this system identification method, runs of PMM test can be reduced while retaining sufficient accuracy, compared to the Fourier integration method. Through the comparisons with sea trial results and the Fourier integration method, the accuracy and efficiency of the newly proposed system identification method, based on least square method, has been validated.

정신훈련이 운동과제 수행시 정확도에 미치는 효과 (The Effect of Mental Practice on Motor Task Performance Accuracy)

  • 이경숙;정유진;천명순;구애련
    • 한국전문물리치료학회지
    • /
    • 제2권2호
    • /
    • pp.40-45
    • /
    • 1995
  • The purpose of this study was to investigate the effectiveness of mental practice in increasing accuracy of performance during motor task. Forty healthy students aged 17 years were randomly assigned to two groups. The experimental group(n=20) performed mental practice; the control group(n=20) performed nothing. The task was dotting. No significant change was seen between pre and post test subtest results following mental practice sessions(p>0.05). The experimental group's accuracy improved a little but this was not valuable statistically(p>0.05). We could not prove that mental practice was effective in increasing accuracy of motor task performance.

  • PDF