• Title/Summary/Keyword: AC7A

Search Result 878, Processing Time 0.029 seconds

Effect of Diameter on Spreading Flame over Electrical Wire with Applied AC Electric Fields (교류전기장이 인가된 상태에서 전선을 통해 전파하는 화염에 대한 전선직경의 영향)

  • Park, S.H.;Lim, S.J.;Kwon, O.B.;Park, J.;Chung, S.H.
    • Journal of the Korean Society of Combustion
    • /
    • v.22 no.3
    • /
    • pp.1-7
    • /
    • 2017
  • An experimental study on spreading flame over electrical wire, which was insulated by Polyethylene(PE) and had different diameters, was conducted with applied AC electric field. The result showed that the flame spread rate decreased in increase of the diameter of insulator at a fixed electric field. The flame spread rate exhibited increase or decrease tendency with applied AC electric field, having three distinct regimes depending on applied voltage and frequency. In each regime, the flame spread rate was characterized by physical parameters of applied electric fields and wire dimensions, and the behaviors could be explained by a thermal balance mechanism.

Activated Carbon-Nickel (II) Oxide Electrodes for Capacitive Deionization Process

  • Gandionco, Karl Adrian;Kim, Jin Won;Ocon, Joey D.;Lee, Jaeyoung
    • Applied Chemistry for Engineering
    • /
    • v.31 no.5
    • /
    • pp.552-559
    • /
    • 2020
  • Activated carbon-nickel (II) oxide (AC-NiO) electrodes were studied as materials for the capacitive deionization (CDI) of aqueous sodium chloride solution. AC-NiO electrodes were fabricated through physical mixing and low-temperature heating of precursor materials. The amount of NiO in the electrodes was varied and its effect on the deionization performance was investigated using a single-pass mode CDI setup. The pure activated carbon electrode showed the highest specific surface area among the electrodes. However, the AC-NiO electrode with approximately 10 and 20% of NiO displayed better deionization performance. The addition of a dielectric material like NiO to the carbon material resulted in the enhancement of the electric field, which eventually led to an improved deionization performance. Among all as-prepared electrodes, the AC-NiO electrode with approximately 10% of NiO gave the highest salt adsorption capacity and charge efficiency, which are equal to 7.46 mg/g and 90.1%, respectively. This finding can be attributed to the optimum enhancement of the physical and chemical characteristics of the electrode brought by the addition of the appropriate amount of NiO.

Operation Characteristic and Harmonic Analysis of 200-MW Modulator (200-MW 모듈레이터의 동작 특성 및 고조파 해석)

  • Park, S.S.;Oh, J.S.;Cho, M.H.;NamKumg, W.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1577-1579
    • /
    • 1994
  • 200-MW pulse modulators(total 11units) for the PLS linac employ the SCR phase control circuit. It controls 3-phase AC line voltage for the high-voltage DC power supply (DCPS, maximum of 25kVDC, 4.2A) which charges the pulse forming network(PFN). The PFN delivers 400kV, 500A, ESW $7.5{\mu}s$ pulse power to the 80-MW klystron amplifier tube. The SCR regulates 3-phase AC power and feeds to the high voltage transformer. Two different types of the transformer configurations namely ${\Delta}-{\Delta}$ and ${\Delta}-Y$, are alternatively installed to 11 modulator units for the suppression of harmonic noises. RC filters and reactors are also installed. Currently, approximately 110-kW of average AC power per unit is consumed at the normal operation level of the modulator with 30pps. This paper presents the operational characteristics of the high power pulse modulator, especially the experimental results of the AC line harmonic components generated by the operation of the high power pulse modulator to suppress the switching noises from the SCR and rectifying diode arrays.

  • PDF

Estimation of Thermal Stability for DGEBA/MDA/PGE-AcAm/CTBN System by TG Analysis (열중량 분석에 의한 DGEBA/MDA/PGE-AcAm/CTBN계의 열적 안정성 평가)

  • Lee, Jae-Yeong;Choe, Hyeong-Gi;Sim, Mi-Ja;Kim, Sang-Uk
    • Korean Journal of Materials Research
    • /
    • v.7 no.3
    • /
    • pp.229-233
    • /
    • 1997
  • Estimation of thermal stability for diglycidy1 ether of bisphenol A(DGEMA)/4, 4'-methylene dianiline (MDA)/pheny1 glycidy1 ether(PGE)-acetamide(AcAm)/carboxy1-terminated acrylonitrile butadiene copolymer (CTBN) system was studied by thermogravimetry(TG) analysis. To get activation energy for thermal degradation, Freeman & Carroll, Kissinger, and Flynn & Wall expressions were used. The activation energy of Freeman & Wall expression was 112.9kj/mol, that of Kissinger expression was 151.5 kj/mol and that of Flynn & Wall was 168.3kj/mol.

  • PDF

Control of Fungal Diseases with Antagonistic Bacteria, Bacillus sp. AC-1

  • Park, Yong-Chul-
    • Proceedings of the Korean Society of Plant Pathology Conference
    • /
    • 1994.06a
    • /
    • pp.50-61
    • /
    • 1994
  • Biological control of important fungal diseases such as Phytophthora blight of red pepper, gary mold rot of vegetables, and powdery mildew of many crops was attempted using an antagonistic bacterium, Bacillus sp. AC-1 in greenhouses and fields. The antagonistic bacterium isolated from the rhizosphere soils of healthy red pepper plant was very effective in the inhibition of mycelial growth of plant pathogenic fungi in vitro including Phytophthora capsici, Rhizoctonia solani, Pyricularia oryzae, Botrytis cinerea, Valsa mali, Fusarium oxysporum, Pythium ultimum, Alternari mali, Helminthosporium oryzae, and Colletotrichum gloeosporioides. Culture filtrate of antagonistic Bacillus sp. AC-1 applied to pot soils infested with Phytophthora capsici suppressed the disease occurrence better than metalaxyl application did until 37 days after treatment in greenhouse tests. Treatments of the bacterial suspension on red pepper plants also reduced the incidence of Phytophthora blight in greenhouse tests. In farmers' commercial production fields, however, the controlling efficacy of the antagonistic bacteria was variable depending on field locations. Gray mold rot of chinese chives and lettuce caused by Botrytis cinerea was also controlled effectively in field tests by the application of Bacillus sp. AC-1 with control values of 79.7% and 72.8%, respectively. Spraying of the bacterial suspension inhibited development of powdery mildew of many crops such as cucumber, tobacco, melon, and rose effectively in greenhouse and field tests. The control efficacy of the bacterial suspension was almost same as that of Fenarimol used as a chemical standard. Further experiments for developing a commercial product from the antagonistic bacteria and for elucidating antagonistic mechanism against plant pathogenic fungi are in progress.

  • PDF

Comparison of Electrical Characteristics of The Solenoid Coils made of YBCO wire and BSCCO wire (BSCCO 선재와 YBCO 선재의 솔레노이드 코일의 전기적 특성 비교)

  • Lim, H.;Lee, D.M.;Lee, Ji-Kwang;Choi, H.;Cha, G.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.43-46
    • /
    • 2007
  • Solenoid coil is one of the commonly used one in superconducting power machines because it can produce uniform magnetic field at the center of the coil. Most of the AC loss in a solenoid coil is magnetization loss which is generated by the perpendicular magnetic field. This paper compares the electrical characteristics of two solenoid coils made of YBCO wire and BSCCO wire. We made and tested the BSCCO solenoid coil and YBCO solenoid coil which had the same number of turns and inner diameter. Number of turns and inner diameter of both coils were 30 turns and 10cm, respectively. AC loss of both coils were calculated by using the finite element method. Result shows that AC loss of YBCO coil was about 1/7 of that of the BSCCO coil when the current was 40A.

Relationship Between Subjective Symptoms with Near Work and Binocular Function (근업시 자각 증상과 양안시 기능의 관계)

  • Shin, Jin-Ah;Lee, Ok-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.125-130
    • /
    • 2007
  • The aim of this work was to study the relationship between subjective symptoms and binocular function during near work in forty one(12-17yr) schoolchildren. CISS symptom survey, amplitude of accommodation, accommodative facility, neagative relative accommodation(NRA)/positive relative accommodation(PRA) near point of convergence(NPC), heterophoria, AC/A ratios were measured. The results of measurement were compared with normal expected value of each test and classified into normal and abnormal group. Accommodative insufficiency was more general than convergence insufficiency and esophoria was greater than exophoria. NRA/PRA showed very high and AC/A ratios were very low compare with normal expected value. The results of CISS was as follows; most frequent symptom was tired, mean score was $16.63{\pm}7.49$, mean number of symptoms were $10.07{\pm}3.04$, and mean number of serious symptoms were $1.98{\pm}2.13$. After classified into 4 groups according to score of symptoms, number of symptoms, and degree of symptoms and then analyze the correlation compare with binocular vision test results. NRA was most correlated with group comparison, accommodative facility was most correlated with score of symptoms, NRA was most correlated with number of symptoms, and near horizontal phorias were most correlated with serious symptoms. NRA showed most correlative relation with near symptoms.

  • PDF

Studies on Ion-exchange Chromatography of Elements in Special Nonferrous Alloys (비철특수합금에서 금속원소의 이온교환 크로마토그라프에 관한 연구)

  • Kyung Woong Lee;Young Jin Yoo
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.2
    • /
    • pp.178-182
    • /
    • 1985
  • The purpose of this study was to develop a separation method of Zn(II), Cu(II) and Mg(II), by ion exchange chromatography using cation exchange resion (Dowex 50w${\times}$8, 80-100 mesh) and anion exchange (Amberlite IRA-400). Ion exchange resions were packed into 25 ${\times}$ 2cm ID column and flow rate was controlled to 0.30 ml/min. Good eluents for separation of nonferrous metal ions such as Zn(II), Cu(II), Mg(II) were as follow: 0.5M $NaNO_3$ (pH 3.1), 0.2~0.5M HCl + 50~60% Acetone, and 1M HAc + 0.1M NaAcf(pH 3.7) aqueous solution. The mixed solution of 0.1M NaAc(pH 3.7), 0.5M HCl + 50% Acetone were found to be the best eluent for step elution. Analysis of metals were determined by atomic absorption spectrophotometer. In addition, separated Zn(II) fraction was obtained by eluted with 0.12N HCl and 1.5N $NH_4OH$ aqueous solution. This solution was titrated by the E. D. T. A.

  • PDF

A Study on the Disinfection of Coliform Group in the Effluent of Sewage Plant by High Voltage Electric Field Treatment (고전압 전기장을 이용한 하수처리장 방류수 중의 대장균군 소독에 관한 연구)

  • Lee, Min-Gyu;Chung, Geun-Sik;Kam, Sang-Kyu
    • Journal of Environmental Science International
    • /
    • v.17 no.7
    • /
    • pp.817-826
    • /
    • 2008
  • Using high voltage electric fields induced by high voltage AC (10-12 kV/cm, 20 kHz) and pulsed (20-30 kV/cm, 40 Hz) electric field generator as a semipermanent and environment-friendly disinfecting apparatus, the disinfection effect of coliform group in the effluent of sewage plant was investigated. The effects of electric field strength, treatment time, discharge area of a discharge tube, water quality factors (electric conductivity, pH and SS) on its death rate were examined. The death rate of coliform group was increased with increasing electric field strength and treatment time. For AC and pulsed electric field generator, the critical electric field strength was 6 kV/cm and 2 kV/cm, respectively, and the critical treatment time was 5 min and 2 min, respectively, regardless of electric field strength. Comparing the death rate of coliform group by AC and pulsed electric fields used in this study, its death rate was higher for the latter than the former, but did not increase linearly with increasing electric field strength. The results obtained for the effects of discharge area, electric conductivity, pH and SS on the death rate of coliform group using AC electric field (12 kV/cm, 20 kHz) were as follows: its death rate showed the trend to increase linearly with increasing discharge area; for the effect of electric conductivity, its death rate was increased with increasing electric conductivity, regardless of ionic species, increased with increasing cationic valency, but was similar between the same cationic valency; the pH $5{\sim}9$ used in this study did not affect its death rate; its death rate was decreased with increasing SS concentration.

Differential Expression of O-glycoprotein Glycans in Cholangiocarcinoma Cell Lines

  • Talabnin, Krajang;Talabnin, Chutima;Ishihara, Mayumi;Azadi, Parastoo;Wongkham, Sopit;Sripa, Banchob
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.2
    • /
    • pp.691-695
    • /
    • 2016
  • Protein glycosylation is the most common posttranslational modification in mammalian cells. Aberrant protein glycosylation has been reported in various diseases, including cancer. We identified and quantified the glycan structures of O-linked glycoprotein from cholangiocarcinoma (CCA) cell lines from different histological types and compared their profiles by nanospray ionization-linear ion trap mass spectrometry (NSI-$MS^n$). Five human CCA cell lines, K100, M055, M139, M213 and M214 were characterized. The results showed that the O-linked glycans of the CCA cell lines comprised tri- to hexa-saccharides with terminal galactose and sialic acids: NeuAc1Gal1GalNAc1, Gal2GlcNAc1GalNAc1, NeuAc2Gal1GalNAc1 NeuAc1Gal2GlcNAc1GalNAc1 and NeuAc2Gal2GlcNAc1GalNAc1 All five CCA cell lines showed a similar glycan pattern, but with differences in their quantities. NeuAc1Gal1GalNAc1 proved to be the most abundant structure in poorly differentiated adenocarcinoma (K100; 57.1%), moderately differentiated adenocarcinoma (M055; 42.6%) and squamous cell carcinoma (M139; 43.0%), while moderately to poorly differentiated adenocarcinoma (M214; 40.1%) and adenosquamous cell carcinoma (M213; 34.7%) appeared dominated by $NeuA_{c2}Gal_1GalNA_{c1}$. These results demonstrate differential expression of the O-linked glycans in the different histological types of CCA. All five CCA cell lines have abundant terminal sialic acid (NeuAc) O-linked glycans, suggesting an important role for sialic acid in cancer cells. Our structural analyses of glycans may provide important information regarding physiology of disease-related glycoproteins in CCA.