• Title/Summary/Keyword: AC-to-DC converter

Search Result 798, Processing Time 0.033 seconds

Pspice ABM MOSFET Model for Conducted EMI Analysis (전도 전자파 장애 분석을 위한 Pspice ABM MOSFET 모델)

  • Lee, J.H.;Lee, D.Y.;Cho, B.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.1876-1878
    • /
    • 1998
  • For an analysis and simulation of the conducted EMI of switching converters, an accurate simulation model for MOSFET is needed. This paper presents a new modeling approach, which incorporates DC output characteristics and AC dynamics especially the parasitic capacitances. It uses Pspice ABM(Analog Behavioral Model) and the MOSFET parameters can be obtained from the Data sheet in the frequency range of interest for EMI analysis. The model verified with an experimental setup and the EMI for a test converter is analyzed with respect to the MOSFET switching waveforms.

  • PDF

자기공명영상에서 신호의 dynamic range와 quantization noise 분석

  • 안창범;이정선;김휴정;이흥규
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.75-75
    • /
    • 2002
  • 목적: 고자장 자기공명영상 시스템 등으로 신호대잡음비가 향상됨에 따라 데이터 측정에서 analog-to-digital converter (ADC)의 quantization noise 가 중요한 시스템 사양으로 부각되고 있다. 특히 자기공명영상은 공간주파수 영역에서 데이터를 측정하기 때문에 dc와 ac간의 신호 차이가 매우 크며, 이러한 dynmic range는 3-D 영상에서 더욱 커진다. 본 연구에서는 다양한 자기총명 영상기법 및 실험 파라미터에 따른 신호의 dynamic range와 ADC의 bit 수에 따른 quantization noise를 살펴봄으로써, 주어진 시스템에 적합한 ADC의 bit 수를 분석하고자 한다. 대상 및 방법: 펄스 시퀀스의 종류, 파라미터, 2D/3D 등에 따른 각 신호의 크기를 수학적으로 모델링하여 신호의 크기를 예측하였다. 또한 whole body MRI 시스템에서 실험을 통하여 신호의 크기를 비교하였다. ADC의 quantization noise를 실험과 시뮬레이션을 통하여 살펴보았다. 시뮬레이션은 test 영상을 Inverse FFT 하여 spatial frequency domain data를 만든 후, 다양한 bit 수의 ADC로 quantization을 한 후 다시 영상을 재구성하였다. 재구성된 영상과 원영상 간의 error가 quantization noise가 된다. 또한 이러한 error가 주파수 영역에서의 error 값과 일치하는지를 확인하였다.

  • PDF

A Study on EMI Filters' construction of 150W Electrodeless fluorescent lamp UTLRA's Ballasts (무전극형광램프 ULTRA 150W용 EMI 필터에 대한 연구)

  • Park, S.;Han, S.;Yu, S.;Song, Y.;Jeong, H.;Jung, B.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.217-221
    • /
    • 2006
  • Offline switching Power supplies have high voltage and high current switching waveforms that generate Electromagnetic Interference(EMI) in the form of both conducted and radiated emissions. Consequently, all off-line power supplies must be designed to attenuate or suppress EMI emissions below commonly acceptable limits. Electrodeless fluorescent lamp's ballasts have AC/DC flyback converter, so we must control the EMI emissions.

  • PDF

Power imbalance analysis of AC electric railway using back-to-back converter (백투백 컨버터를 이용한 교류전기철도의 전력 불평형 현상 분석)

  • Song, Shengli;Woo, Jehun;Jo, Jongmin;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.286-287
    • /
    • 2020
  • 본 논문은 단상 전기철도 시스템의 불평형 부하 특성으로 인한 3상 계통의 전력 불평형을 보상하기 위해 백투백 컨버터를 적용하였으며, 실험을 통해 전력 불평형 성능 개선 특성을 검증하였다. 3상 전압은 스코트 변압기를 통해 2개의 M-T상 전압으로 출력되며, 전력 불평형 개선을 위해 적용된 백투백 컨버터는 DC 링크를 공유하며 각각 M-T상에 연계된다. 백투백 컨버터는 M-T상에 연계된 부하용량 차이에 따른 불평형 조건에 관계없이 M상과 T상 계통 라인에 동일한 전력이 공급되도록 제어하는 역할을 수행하며, 제어 알고리즘은 동기좌표계에서 구현하였다. 백투백 컨버터의 프로토 타입은 3레벨 NPC 컨버터로 설계하였으며, M상 5kW, T상 1kW 부하에서 전력보상 장치가 동작하고 있음에도 완전히 해결되지 않은 불평형 현상에 대해 분석한다.

  • PDF

A High-efficiency Single-phase Photovoltaic Inverter for High-voltage Photovoltaic Panels (고전압 태양광 패널용 고효율 단상 태양광 인버터)

  • Hyung-Min, Ryu
    • Journal of IKEEE
    • /
    • v.26 no.4
    • /
    • pp.584-589
    • /
    • 2022
  • For DC-AC power conversion from a high-voltage photovoltaic panel to a single-phase grid, the two-stage transformerless inverter with a buck-boost converter followed by a full-bridge inverter is widely used. To avoid an excessive leakage current due to the large parasitic capacitance of the photovoltaic panel, the full-bridge inverter can only adopt the bipolar PWM which results in much higher power loss compared to the unipolar PWM. In order to overcome such a poor efficiency, this paper proposes a new topology in which an IGBT and a diode for circuit isolation are added to the buck-boost converter. The proposed circuit isolation method allows the unipolar PWM in the full-bridge inverter without any increase in the leakage current so that the overall efficiency can be improved. The validity of the proposed solution is verified by computer simulation and power loss calculation.

Development of the 5kW Class Polymer Electrolyte Fuel Cell System for Residential Power Generation (5kW 급 주택용 고분자 연료전지 시스템)

  • Yang, Tae-Hyun;Park, Gu-Gon;Yoon, Young-Gi;Lee, Won-Yong;Yoon, Wang-Lai;Kim, Chang-Soo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.14 no.1
    • /
    • pp.35-45
    • /
    • 2003
  • Polymer electrolyte fuel cells(PEFC) have been considered to be a suitable candidate for residential, portable and mobile applications, due to their high efficiency and power density, even at low operating temperature. KIER developed a 5kW class PEFC system for residential application and operated the system for over 1,000 hours. To develop a 5kW PEFC system, performance of a cell was improved through successive tests of single cell of small and large area. Fabrication of three 2,5 kW class stacks, design and fabrication of natural gas reformer, design of auxiliary equipments such as DC/DC converter, DC/AC inverter and humidifying units were carried out along with integration of components, operation and evaluation of total system. During the development period from 1999 to 2001, MEA(membrane electrode assembly) fabrication technologies, design and fabrication technologies for separators, stacking technologies and so on were developed, thereby providing basis for developing stacks of higher efficiency and power density in the future. Experience of development of natural gas reformer opened possibilities to use various kinds of fuels. Main results obtained from the development of a 5kW class PEFC system for residential application are summarized.

On the Design of Power Supply System for Freight Train Reefer Container Based on Simulation

  • Kim, Joouk;Hwang, Sunwoo;Lee, Jae-Bum;Hwang, Jaemin;Chae, Uri
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.3
    • /
    • pp.249-257
    • /
    • 2022
  • In recent years, if we order food by easily accessing the online market with our smartphone, we can receive the product in a fresh state at dawn the next day. Cold chain is an industry that can create high added value because it has both the characteristics of general logistics and sensitivity to temperature. Based on the electrical specifications derived from the reefer container capacity requirement investigation, we proved that power supply to up to 33 reefer containers can be made by using three additional auxiliary power supplies which are applied for freight trains in Korea. In this paper, we conducted a research on a design of power supply system for freight train reefer container based on simulation as a basic research necessary for low-temperature distribution and cold chain construction based on the reefer container railroad. Consequently, the simulation was conducted using the three-phase inverter diagram in PSIM and the SVPWM (3-harmonic injection method) control technique, and it was verified that the required power voltage was satisfied with 622Vdc, which is lower than the input voltage of general SPWM of 718Vdc. The details of this paper could be used as a foundational study for constructing cold chains based on a reefer container dedicated to freight trains in the future.

A harmonic reduction scheme for 12-pulse diode rectifiers by auxiliary voltage supply (보조전원장치에 의한 12-펄스정류기의 고조파 저감)

  • Kim, Sung-Hwan;Kim, Jong-Su;Oh, Sae-Gin;Yoon, Kyoung-Kuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.7
    • /
    • pp.916-922
    • /
    • 2014
  • Diode rectifiers have been widely used for an AC to DC converter. But a big problem is that they include large harmonics components in the input currents. A 12-pulse configuration with phase shifting transformer is useful for reducing them. however, it still includes the ($12{\pm}1$)th (m; integer) harmonics in the input currents. In this paper, we propose a single-phase square wave auxiliary voltage supply which is inserted in the middle DC bus. It reduces harmonics especially the 11th and 13th and the harmonic characteristic becomes almost equivalent to a 24-pulse rectifier. Theoretical analysis of the combined 12-pulse diode rectifier with the auxiliary supply is presented and a control method of the auxiliary supply is proposed. The reduction in the input current harmonics is verified by simulation using software PSIM.

Maximum Power Point Tracking Controller Connecting PV System to Grid

  • Ahmed G. Abo-Khalil;Lee Dong-Choon;Choi Jong-Woo;Kim Heung-Geun
    • Journal of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.226-234
    • /
    • 2006
  • Photovoltaic (PV) generators have nonlinear V-I characteristics and maximum power points which vary with illumination level and temperature. Using a maximum power point tracker (MPPT) with an intermediate converter can increase the system efficiency by matching the PV systems to the load. This paper presents a maximum power point tracker based on fuzzy logic and a control scheme for a single-phase inverter connected to the utility grid. The fuzzy logic controller (FLC) provides an adaptive nature for system performance. Also the FLC provides excellent features such as fast response, good performance and the ability to change the fuzzy parameters to improve the control system. A single-phase AC-DC inverter is used to connect the PV system to the grid utility and local loads. While a control scheme is implemented to inject the PV output power to the utility grid at unity power factor and reduced harmonic level. The simulation results have shown the effectiveness of the proposed scheme.

A Study on Load Simulator for Traction system combined testing (전동차 조합시험을 위한 부하 시뮬레이터에 관한 연구)

  • Kim, Gil-Dong;Lee, Han-Min;Oh, Seh-Chan;Pak, Sung-Hyuk;Kim, Jong-Dae
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1643-1645
    • /
    • 2005
  • A newly-built inverter has to undergo a series of stress tests in the final stage of production line. This can be achieved by connecting it to a dynamometer consisting of a three-phase machine joined by a rigid shaft to a DC load machine. The latter is controlled to create some specific load characteristic needed for the test. In this paper a test method is proposed, in which no mechanical equipment is needed. The suggested test stand consists only of a inverter to be tested and a simulator converter. Both devices are connected back- to-back on the AC-side via smoothing reactors. The simulator operates in real-time as an equivalent load circuit, so that the device under test will only notice the behaviour of a three-phase machine under consideration of the load. In odor to wove rightness of the suggested test method, the simulation and actural experiment rallied out emulation for a 2.2kW induction motor.

  • PDF