A Study on the High-Efficiency. High-Power-Factor AC/DC Boost Converter Using Energy Recovery (에너지 회생 스너버를 적용한 고효률, 고역률 AC/DC Boost 컨버터에 관한 연구)

  • Ryu, Chang-Gyu;Kim, Yong;Bae, Jin-Yong;Baek, Soo-Hyun;Choi, Geun-Soo;Gye, Sang-Bum
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.160-163
    • /
    • 2004
  • A passive lossless turn-on/turn-off snubber network is proposed for the boost PWM converter. Previous AC/DC PFC Boost Converter perceives feed forward signal of output for average current-mode control. Previous Boost Convertor, the Quantity of input current will be decreased by the decrease of output current in light load, and also Power factor comes to be decreased. Also the efficiency of converter will be decreased by the decrease of power factor. The proposed converter presents the good PFC, low line current harmonic distortions and tight output voltage regulations using energy recovery circuit. All of the semiconductor devices in the converter are turned on under exact or near zero voltage switching(ZVS). No additional voltage and current stresses on the main switch and main diode occur. To show the superiority of this converter is verified through the experiment with a 640W, 100kHz prototype converter.

  • PDF

Current THD Improvement of Valley-Fill Rectifier (밸리-필 정류기의 전류 THD 개선)

  • Lee, Chi-Hwan;Choi, Nam-Yerl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.87-94
    • /
    • 2008
  • A method for improving current THD of Valley-fill rectifier is proposed in this paper. The proposed topology combines a boosting inductor with Valley-fill rectifier which carry out AC/DC conversion and PFC simultaneously The boosting effect by PWM switching makes low THD current and improve of Valley-fill rectifier. The operation modes and THD of input current are analyzed as applied the boosting inductor, and the optimum value of boosting inductor is determined A 100[W] single-stage converter has been designed and tested. Experimental results are resented to verify the validity of the proposed method.

A Utility Interactive Photovoltaic Generation System Using PWM Converter (PWM 컨버터를 이용한 계통연계형 태양광발전 시스템)

  • Chung, J.H.;Jho, J.M.;Jeon, K.Y.;Lee, S.H.;Oh, B.H.;Kim, S.N.;Kim, Y.J.;Han, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1253-1255
    • /
    • 2003
  • Since the residential load is an AC load and the output of solar cell is a DC Power, the photovoltaic system needs the DC/AC converter to utilize solar cell. In case of driving to interact with utility line, in order to operate at unity power factor, converter must provide the sinusoidal wave current and voltage with same phase of utility line. Since output of solar cell is greatly fluctuated by insolation. it is necessary that the operation of solar cell output in the range of the vicinity of maximum power point. In this paper DC/AC converter is three phase PWM converter with smoothing reactor. And then, feedforward control used to obtain a superior characteristic for current control and digital PLL circuit used to detect the phase of utility line.

  • PDF

Analysis of Capacitor Voltage and Boost Vector in Neutral-Point-Clamped and H-Bridge Converter (NPC와 H-Bridge 컨버더의 부스트 벡터와 커패시터 전압의 해석)

  • 김정균;김태진;강대욱;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.274-284
    • /
    • 2003
  • Multi-level converter that is high-capacity electric power conversion system is used widely to electric motor drive system and FATCs(Flexible AC Transmission Systems). H-Bridge converter has been prevalently applied to shunt-type system because it can be easily expanded to the multi-level. In steady states, converter is normally operated in the range of 0.7∼0.8 of modulation Index. Even though zero vectors are not imposed to high modulation index, DC-Link voltage Is constant. It means that converter has another boost vector except for zero vectors among several vectors in 3-level converter. This paper has examined the principle of boost vector and investigated the difference between another boost vector and zero vectors in 3-level converter. In addition, this paper has analysed and compared the charging currents and the capacitor voltages of two topologies. The currents and voltages are related to reference voltage. Therefore, it proposed the calculation method for the voltage ripple and the charging current of each capacitor and compared various DC-Link voltage control methods through the simulation.

Practical Design and Implementation of a Power Factor Correction Valley-Fill Flyback Converter with Reduced DC Link Capacitor Volume (저감된 DC Link Capacitor 부피를 가지는 역률 개선 Valley-Fill Flyback 컨버터의 설계 및 구현)

  • Kim, Se-Min;Kang, Kyung-Soo;Kong, Sung-Jae;Yoo, Hye-Mi;Roh, Chung-Wook
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.4
    • /
    • pp.277-284
    • /
    • 2017
  • For passive power factor correction, the valley fill circuit approach is attractive for low power applications because of low cost, high efficiency, and simple circuit design. However, to vouch for the product quality, two dc-link capacitors in the valley fill circuit should be selected to withstand the peak rectified ac input voltage. The common mode (CM) and differential mode (DM) choke should be used to suppress the electromagnetic interference (EMI) noise, thereby resulting in large size volume product. This paper presents the practical design and implementation of a valley fill flyback converter with reduced dc link capacitors and EMI magnetic volumes. By using the proposed over voltage protection circuit, dc-link capacitors in the valley fill circuit can be selected to withstand half the peak rectified ac input voltage, and the proposed CM/DM choke can be successfully adopted. The proposed circuit effectiveness is shown by simulation and experimentally verified by a 78W prototype.

Harmonics and Power Factor Controller for Single-Phase PWM Converter Using Two Input Sensors (2개의 입력센서를 갖는 단상 PWM 컨버터용 고조파 및 역률 제어기)

  • Jeon Young-Soo;Lee Kyung-Bin;Han Byung-Moon;Han Hoo-Sek
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.10
    • /
    • pp.618-624
    • /
    • 2004
  • In this paper, a new controller for a single-phase PWM converter is described, which requires only two input parameters, the dc voltage and the ac current. Detail simulation model with EMTDC(Electro-Magnetic Transient program for DC transmission) including power circuit and controller was developed to verify the operation of proposed controller. The application feasibility of the proposed controller was verified through experimental works with a prototype. The proposed controller has a simple structure in the point of hardware implementation, and shows excellent performance in normal operation as well as in sudden load change.

A New PWM Strategy for reducing Common Mode Voltage in PWM boost Converter/lnverter Fed ac Motor Drives. (PWM 승압형 컨버터/인버터를 시스템에서 커먼 모드 전압 저감을 위한 새로운 PWM 기법)

  • Lee, Hyeoun-Dong;Sul, Seung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2484-2486
    • /
    • 1999
  • 본 논문에서는 PWM 승압형 컨버터/인버터를 사용한 교류전동기 구동시스템에서 커먼 모드 전압의 크기를 dc 버스 전압 1/3이하로 제한시키는 새로운 공간전압벡터 PWM 기법을 제안한다. Dc 버스 전압의 2/3에 해당하는 커먼 모드 전압 펄스가 발생하는 경우에 대하여 고찰하고 각각의 경우에 대한 인버터 스위칭 시점의 이동을 통한 제거 방법을 제안한다. 제안된 방법은 부가의 하드웨어를 요구하지 않고 소프트웨어적으로 손쉽게 구현될 수 있으며, 전력변환기의 제어성능에 영향을 미치지 않는다는 장점을 가진다.

  • PDF

Preliminary Design of AC/DC Converters for ITER Superconducting Magnet (ITER 초전도자석 전원공급장치의 예비설계)

  • Choi, J.;Oh, J.S.;Suh, J.H.;Lee, S.;Jo, S.;Jung, W.;Park, H.;Chung, I.;Hwang, K.;Liu, H.
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.245-246
    • /
    • 2012
  • ITER 초전도자석 전원공급장치의 예비설계가 실제 크기 6펄스 R&D 컨버터의 제작 및 시험결과를 기반으로 수행되었다. ITER 컨버터는 자체적으로 지지되는 알루미늄 버스바 구조로 제작되며, 이 버스바에 양면 클램핑 방식으로 조립되는 Thyristor 스위치는 4인치 규격으로써 컨버터의 종류에 따라 한 개의 암 당 8 - 16 개의 소자가 병렬로 구성된다. ITER 컨버터 예비설계는 알루미늄 버스바 구조설계, 컨버터 냉각설계, 컨버터 전기회로 설계, 컨버터 고장해석 및 보호설계, 시험절차 및 요건 등을 포함하며, 본 논문에서 그 설계결과를 기술한다. ITER 컨버터는 예비설계 결과를 기반으로 상세설계 및 제작설계를 거친 후 제작된다.

  • PDF

Characteristics and Implementation of LCL Type DC-DC Converter for Constant Voltage Power supply (LCL형 전압형 컨버터의 특성 분석 및 구현)

  • Park, Sangeun;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.260-267
    • /
    • 2015
  • An LCL-type isolated dc-dc converter is analyzed, using ac approximation. Analyses to express characteristics on the proposed converter are derived under steady and ideal elements conditions in this paper. The two operating modes can be identified from the analysis results representing different device conduction sequences. This converter is capable of achieving required output voltage(step up or down) operations with inductance ratio while operated at fixed frequency with constant duty ratio-50%. Experimental results show that the designed converter based on Q has zero voltage switching and constant output voltage at different load variations to verify the analysis.

Operational Characteristic Analysis of DC Micro-grid with Detail Model of Distributed Generation (분산전원 세부모델을 적용한 DC Micro-grid의 동작특성 분석)

  • Lee, Ji-Heon;Kwon, Ki-Hyun;Lee, Hye-Yeon;Han, Byung-Moon
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.151-153
    • /
    • 2008
  • DC 마이크로그리드는 태양광과 연료전지와 같은 DC 출력의 분산전원, 풍력이나 가스엔진과 같은 AC 출력의 분산전원이 이차전지나 수퍼커패시터와 같은 에너지 저장장치와 직류로 결합되어 있는 구조로, 최근 급증하고 있는 디지털부하에 고품질, 고신뢰도 전력을 공급하는 새로운 직류배전시스템이다. 본 연구에서는, 먼저 DC 마이크로그리드의 한 시스템 구성을 가정하고, 이들 분산전원과 에너지저장의 컨버터를 제어하는 기법을 제안하였다. 또한 PSCAD/EMTDC 소프트웨어를 사용하여 각각의 분산전원의 세부모델을 구현하고, 이를 DC 마이크로그리드로 구성한 후 분산전원의 생산량, 에너지저장의 저장량, 부하의 소모량, 연계 계통의 공급량을 타당한 시나리오로 가정하여 전체 마이크로그리드의 동작을 분석하였다.

  • PDF