• 제목/요약/키워드: AC source

검색결과 723건 처리시간 0.034초

마이크로소스 인덕터 크기 결정에 관한 기초연구 (Study on Micro-Sources Modeling and optimal series inductance size)

  • 김영섭;손광명
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.137-139
    • /
    • 2003
  • Micro-Sources arc emerging as a providing environmentally friendly and reliable and effective solution. Micro-Source converter DC voltage of prime mover to AC voltage using voltage source inverter for interjecting with AC grid system. This paper studies optimal series inductance size for interjecting with AC grid system.

  • PDF

교류전원 구동방식에 의한 형광 OLED의 발광 특성 (Emission Characteristics of Fluorescent OLED with Alternating Current Power Source Driving Method)

  • 서정현;김지현;주성후
    • 한국전기전자재료학회논문지
    • /
    • 제27권2호
    • /
    • pp.104-109
    • /
    • 2014
  • To operate organic light emitting device (OLED) with alternating current (AC) power source without AC/DC(direct current) converter, we fabricated the fluorescent OLED and measured the emission characteristics with AC and DC. The OLED operated by AC showed higher maximum current efficiency of 8.2 cd/A and maximum power efficiency of 8.3 lm/W. But current efficiency and power efficiency of AC driven OLED showed worse than DC driven OLED at high voltage above 10 V. This result can be explained by the peak voltage of AC was $\sqrt{2}$ times than DC, In case of low driving voltage the emission characteristics were improved by the peak voltage of AC, but in case of high driving voltage the emission efficiencies were decreased by the roll off phenomena. Finally, serial OLED arrays using twelve OLEDs driven by AC 110 V showed average voltage of 9.17 V, voltage uniformity of 99.0%, average luminance of $1,175cd/m^2$, luminance uniformity of 94.4%.

4-레그 PWM 컨버터/인버터와 AC 리액터를 사용한 새로운 3상 라인 인터렉터브 무정전전원장치의 개발 (Development of Novel 3-Phase Line-interactive UPS System using 4-leg PWM Converter/Inverter and AC Reactor)

  • 지준근;김효성;설승기;김경환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.77-81
    • /
    • 2004
  • In this paper a novel line interactive UPS (Uninterruptible Power Supply) using the two 4-leg VSCs and AC line reactor is proposed. The 4-leg Voltage Source Converter(VSC) can use the DC link voltage effectively by the 3-D SVPWM method. Hence the DC battery voltage can be reduced by $15\%$ in comparison to that of the conventional line-interactive UPS system. One VSC is in parallel with the AC line reactor of the power source side, and the other is in series with the load. The parallel 4-leg voltage source inverter controls three-phase line voltage independently in order to control the line reactor current indirectly. It eliminates the neutral line current and the active ripple power of the source side using the pqr theory so that unity power factor and the sinusoidal source current can be achieved even though both the source and the load voltages have zero sequence components. The series 4-leg voltage source inverter compensates the line voltage and allows the load voltage to be balanced and harmonic-free. Both of parallel and series 4-leg voltage source inverters always act as independently controllable voltage sources, so that three-phase output voltage shows a seamless transition to the backup mode. The feasibility of the proposed UPS system has been investigated and verified through computer simulation results.

  • PDF

Three-Phase Soft Switching Sinewave Inverter with Bridge Power Module Package Configurated Auxiliary Resonant AC Link Snubber

  • Iyomori Hisashi;Nagai Shin-ichiro;Shiraishi Kazuhiro;Ahmed Tarek;Eiji Hiraki;Mutsuo Nakaoka
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.507-510
    • /
    • 2003
  • This paper presents a novel prototype of tile three-phase bridge power block module type a auxiliary resonant AC link snubber circuit, which is effectively used for the three-phase voltage source type sinewave soft switching PWM inverter using IGBTs. Its operating principle Is described for current source load model, along with its practical design approach based on the simulation data. The performance evaluation of the three-phase voltage source type snewave soft switching PWM inverter incorporating a single three-phase bridge mo여le of active auxiliary resonant AC link snubber treated here Is illustrated, which is concerned with power duality efficiency power loss analysis. This inverter is discussed as compared with those of tile three-phase voltage source type sinewave hard switching PWM inverter. The power loss analysis of this soft switching PWM Inverter using IGBT power modules is evaluated on the basis of the measured v-i characteristics and switching power losses of IGBT, and antiparaliel diodes. The practical effectiveness of this inverter is proven by the power loss analysis for distributed power supply.

  • PDF

단상 Quasi Z-소스 동적전압보상기(DVR) (A Single-Phase Quasi Z-Source Dynamic Voltage Restorer(DVR))

  • 이기택;정영국;임영철
    • 전력전자학회논문지
    • /
    • 제15권4호
    • /
    • pp.327-334
    • /
    • 2010
  • 본 논문에서는 새로운 quasi Z-소스 토폴로지의 동적전압보상기를 제안한다. 제안된 시스템은 quasi Z-소스 PWM 교류-교류 컨버터를 기반으로 하고 있으며, 입력단과 출력단은 공통 접지이고, 연속적인 입력전류 모드(CCM)로 동작하는 특징을 가지고 있다. 전원 전압의 sag와 swell을 검출하기 위하여, 피크치 전압 검출기법이 사용되었으며, 제안된 시스템의 동작 원리를 제시하고 회로 해석을 하였다. 제안된 시스템은 30% 전압 swell과 60%의 심한 전압 sag가 발생하여도 과전압과 부족전압에 대하여 순간적으로 보상을 하였으며, 부하전압을 정현파의 정격전압으로 유지할 수 있었다. PSIM 시뮬레이션과 실험결과를 통하여 본 연구의 타당성을 입증하였다.

AC SSCB를 이용한 새로운 3상 Static Transfer Switch (New Three-Phase Static Transfer Switch using AC SSCB)

  • 송승민;김진영;김인동
    • 전기학회논문지
    • /
    • 제67권5호
    • /
    • pp.626-634
    • /
    • 2018
  • These days, widespread use of sensitive loads and distributed generators makes static transfer switch (STS) an essential component in power circuits to achieve a good power quality for AC Grids. In case of a short-circuit fault, previous STS cannot break the fault current. However, the proposed STS has the capability of breaking it quickly as a circuit breaker. Also if there are power quality problems such as Sag/Swell, the proposed STS can quickly transfers the load to the good quality source. Furthermore it is proved that the transfer time of the proposed STS is within one half of period of 3-phase source frequency regardless of the type of load. It is anticipated that the proposed STS may be utilized to realize many stable and reliable AC grid systems.

AC/HVDC 시스템의 조류계산 및 EMTP 시뮬레이션 (Load Flow Calculation and EMTP Simulation of AC/HVDC System)

  • 김진하;정교범;오성철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.432-434
    • /
    • 1997
  • In order to find the steady-state operating condition of HVDC system interacting with AC power system, the load flow calculation of AC/HVDC system is performed. For the calculation, each generating unit is modeled by an equivalent voltage source and coupled impedance. The rectifier station is modeled by a controlled DC voltage source. EMTP simulation of the AC/HVDC system is also performed to verify the result of the load flow calculation.

  • PDF

교류전압 보상 기능을 갖는 독립형 단상 연료전지 마이크로 소스 (Stand-Alone Type Single-Phase Fuel Cells Micro-Source with ac Voltage Compensation Capability)

  • 정영국
    • 전기학회논문지
    • /
    • 제58권1호
    • /
    • pp.35-41
    • /
    • 2009
  • This paper proposes a stand alone type single-phase fuel cells micro-source with a voltage sag compensator for compensating the ac output voltage variations (sag or swell) of micro-source. The proposed micro-source is consist of a PEM(polymer electrolyte membrane) fuel cells simulator, a full bridge de converter, a 60Hz PWM(pulse width modulation) VSI(voltage source inverter), and a voltage sag compensator. Voltage sag compensator is similar to the configuration of hybrid series active power filter, and it is directly connected to micro-source through the injection transformer. Compensation algorithm of a voltage sag compensator adopts a single phase p-q theory. Effectiveness of the proposed the system is verified by the PSIM(power electronics simulation tool) simulation in the steady state and transient state which the proposed system is able to simultaneously compensate the harmonic current and source voltage sag or swell.

A Ringing Surge Clamper Type Active Auxiliary Edge-Resonant DC Link Snubber-Assisted Three-Phase Soft-Switching Inverter using IGBT-IPM for AC Servo Driver

  • Yoshitsugu, Junji;Yoshida, Masanobu;Hiraki, Eiji;Inoue, Kenji;Ahmed, Tarek;Nakaoka, Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제2B권3호
    • /
    • pp.115-124
    • /
    • 2002
  • This paper presents an active auxiliary edge-resonant DC link snubber with a ringing surge damper and a three-phase voltage source type zero voltage soft-switching inverter with the resonat snubber treated here for the AC servo motor driver applications. The operation of the active auxiliary edge-resonant DC link snubber circuit with PWM voltage is described, together with the practical design method to select its circuit parameters. The three-phase voltage source type soft-switching inverter with a single edge-resonant DC link snubber treated here is evaluated and discussed for the small-scale permanent magnet (PM) type-AC servo motor driver from an experimental point of view. In addition to these, the AC motor stator current and its motor speed response for the proposed three-phase soft-switching inverter employing Intelligent Power Module(IPM) based on IGBTS are compared with those of the conventional three-phase hard-switching inverter using IPM. The practical effectiveness of the three-phase soft-switching inverter-fed permanent magnet type AC motor speed tracking servo driver is proven on the basis of the common mode current in a novel type three-phase soft-switching inverter-fed AC motor side and the conductive noise on the mains terminal interface voltage as compared with those of the conventional three-phase hard-switching inverter-fed permanent magnet type AC servo motor driver for the speed tracking applications.

단일 Quasi Z-소스 AC-AC 컨버터에 의한 4상한 출력 AC전압 제어 (Four quadrant output AC voltage control using a single quasi Z-source AC-AC converter)

  • 엄준현;박홍순;정영국;임영철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 추계학술대회 논문집
    • /
    • pp.141-142
    • /
    • 2013
  • 본 논문에서는 단일 Quasi Z-소스 AC-AC 컨버터에 의한 4상한 출력 AC전압 제어를 제안하였다. 제안된 듀티비 제어방법을 통하여 한 대의 Quasi Z-소스 AC-AC 컨버터로도 동상의 벅-부스트 모드와 역상의 벅-부스트 모드를 모두 출력하는 4상한 출력 AC전압 제어를 하였다. 한 대의 Quasi Z-소스 AC-AC 컨버터만으로 종전의 듀티비 제어에 의해 동상의 부스트 모드와 역상의 벅-부스트 모드의 출력 전압이 발생되며, 제안한 듀티비 제어에 의해 동상의 벅 모드가 출력되는 4상한 출력 AC전압 제어법을 PSIM시뮬레이션에 의하여 입증하였다.

  • PDF