Steady State and Transient Analysis of Switched Reluctance Motor Drive Fed from a Controlled AC-DC Rectifier

  • Moussa, Mona Fouad
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1495-1502
    • /
    • 2017
  • The Theory of operation of switched reluctance motors (SRM) depends on the reluctance torque, where energy is transferred to stator winding only. Although its construction is simple, the electrical design is complex, due to the switching configuration needed to deliver power to stator coils. However, because of the nonlinearly of magnetic circuit, SRM has torque ripple. This paper proposes a new strategy to drive SRM from a single-phase AC supply. Each stator winding is connected to AC-DC or AC-AC converters, which is called branch. All branches are connected in parallel to a single-phase AC supply. A shaft encoder allows current production in stator winding during the positive torque production region and terminates it during the negative torque production region. A magnetic flux is produced between stator poles when current is supplied from AC supply to stator coil and repeats many cycles as long as the rate of change of stator inductance is positive. Different possibilities for the configurations of AC-AC or AC-DC converters are introduced to drive SRM from the single-phase AC supply. A case study is presented for a SRM fed from AC supply through semi-controlled AC-DC converter is presented. A simulation model is introduced and verified by experimental rig for two-phase SRM.

Improved Modification of the Closed-Loop-Controlled AC-AC Resonant Converter for Induction Heating

  • Dhandapani, Kirubakaran;Sathi, Rama Reddy
    • ETRI Journal
    • /
    • 제31권3호
    • /
    • pp.298-303
    • /
    • 2009
  • A single-switch parallel resonant converter for induction heating is implemented. The circuit consists of an input LC-filter, a bridge rectifier, and a controlled power switch. The switch operates in soft commutation mode and serves as a high frequency generator. The output power is controlled via the switching frequency. A steady state analysis of the converter operation is presented. A closed-loop circuit model is also presented, and the experimental results are compared with the simulation results.

  • PDF

Z-Source Converter with Maximum Boost Voltage Gain

  • Nguyen, Minh-Khai;Jung, Young-Gook;Lim, Young-Cheol
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 추계학술대회 논문집
    • /
    • pp.112-114
    • /
    • 2008
  • This paper proposes a new two-stage Z-source converter (TSZC). The purpose of the proposed system is to obtain the ac voltage with a maximum boost voltage for fuel cell applications as a renewable energy source. In order to provide a continuous current path, a switching strategy for the dc-ac ZSI and ac-ac ZSC of the proposed system was used. The operation principle, analysis and simulation results of 1.2 kW fuel cell stack were also presented.

  • PDF

Clinical and Radiological Outcomes of Modified Phemister Operation with Coracoclavicular Ligament Augmentation Using Suture Anchor for Acute Acromioclavicular Joint Dislocation

  • Cho, Nam Su;Bae, Sung Ju;Lee, Joong Won;Seo, Jeung Hwan;Rhee, Yong Girl
    • Clinics in Shoulder and Elbow
    • /
    • 제22권2호
    • /
    • pp.93-99
    • /
    • 2019
  • Background: Modified Phemister operation has been widely used for the treatment of acute acromioclavicular (AC) joint dislocation. Additionally, the use of suture anchor for coracoclavicular (CC) fixation has been reported to provide CC stability. This study was conducted to evaluate the clinical and radiological results of a modified Phemister operation with CC ligament augmentation using suture anchor for acute AC joint dislocation. Methods: Seventy-four patients underwent the modified Phemister operation with CC ligament augmentation using suture anchor for acute AC joint dislocation and were followed-up for an average of 12.3 months. The visual analogue scale (VAS), range of motion, Constant score, and Korean shoulder scoring system (KSS) were used for clinical assessment. Acromioclavicular interval (ACI), coracoclavicular distance (CCD), and acromioclavicular distance (ACD) were obtained to evaluate the radiological assessments. Results: At the last follow-up, the mean VAS Score was 1.7 points, the mean joint range of the forward flexion was $164.6^{\circ}$, external rotation at the side was $61.2^{\circ}$ and internal rotation to the posterior was a level of T12. The mean Constant score and the mean KSS was 82.7 points and 84.2 points, respectively. At the mean ACI, CCD, and ACD, significant differences were found preoperatively and at the last follow-up. When the ACI, CCD, and ACD were compared with the contralateral unaffected shoulder at the last follow-up, the affected shoulders had significantly higher values. Conclusions: The modified Phemister operation with CC ligament augmentation using suture anchor is clinically and radiologically effective at acute AC joint dislocation.

Wireless Energy Transmission High-Efficiency DC-AC Converter Using High-Gain High-Efficiency Two-Stage Class-E Power Amplifier

  • Choi, Jae-Won;Seo, Chul-Hun
    • Journal of electromagnetic engineering and science
    • /
    • 제11권3호
    • /
    • pp.161-165
    • /
    • 2011
  • In this paper, a high-efficiency DC-AC converter is used for wireless energy transmission. The DC-AC convertter is implemented by combining the oscillator and power amplifier. Given that the conversion efficiency of a DC-AC converter is strongly affected by the efficiency of the power amplifier, a high-efficiency power amplifier is implemented using a class-E amplifier structure. Also, because of the low output power of the oscillator connected to the input stage of the power amplifier, a high-gain two-stage power amplifier using a drive amplifier is used to realize a high-output power DC-AC converter. The high-efficiency DC-AC converter is realized by connecting the oscillator to the input stage of the high-gain high-efficiency two-stage class-E power amplifier. The output power and the conversion efficiency of the DC-AC converter are 40.83 dBm and 87.32 %, respectively, at an operation frequency of 13.56 MHz.

직교류 합성 충전 패턴을 이용한 풍력 연계용 ESS의 배터리 충전 효율 향상 (Improvement of Battery Charging Efficiency of ESS for Wind Power Application Using DC-AC Hybrid Charging Pattern)

  • 이종학;송승호
    • 전력전자학회논문지
    • /
    • 제22권4호
    • /
    • pp.330-335
    • /
    • 2017
  • Increased fossil fuel consumption causes global warming, environmental pollution, and abnormal climate change. Wind-generated power installation is proposed to solve this problem. Recently, the wind power plant construction case encourages the installation of the energy storage system (ESS) to improve the intermittency of wind power. The maximized ESS operation profits connected to wind power are not generated in the simplest operation pattern of charging at night and discharging at day. The battery charging efficiency improvement should be considered to get more profits. Thus, there is a possibility of increasing ESS operation profits by analyzing the battery AC and DC charging/discharging efficiency and the yearly average sealed maintenance free (SMP) in hours. In this paper, the battery impedance characteristic, AC and DC charging/discharging efficiency, and the yearly average SMP are analyzed. The operation scenario to improve the ESS battery charging efficiency connected to wind power is proposed and verified via simulation.

양안시 변화에 대한 라식수술의 영향에 관한 연구 (Study on the Influence of LASIK on Binocular Change)

  • 이기석;성아영
    • 한국안광학회지
    • /
    • 제11권3호
    • /
    • pp.267-273
    • /
    • 2006
  • 본 연구는 LASIK(Laser-assisted In Situ Keratomileusis)을 받은 성인 남녀 36명을 대상으로 수술 전과 후의 사위, Calculated AC/A, Gradient AC/A, 조절력에 관하여 변화를 분석하였다. 사위의 경우, 수술 전 후 원거리에서 정위 2.78% 감소, 외사위 2.78% 증가로 나타났으며, 근거리에서는 외사위에서 5.55% 증가, 내사위에서는 5.55%감소를 나타내었다. AC/A비의 경우, Calculated AC/A에서 0.36만큼, 조절력은 1.25D만큼의 감소결과를 나타내었다. Gradient AC/A는 0.34감소와 PC/A는 0.09의 증가를 보였으나, 유의성은 보이지 않았다.

  • PDF

Modified Ac-Dc Single-Stage Converters

  • Moschopoulos, Gerry;Liu, Yan;Bassan, Sondeep
    • Journal of Power Electronics
    • /
    • 제7권1호
    • /
    • pp.44-54
    • /
    • 2007
  • Ac-dc power conversion can either be done with two separate converter stages or with a single converter stage. Two-stage ac-dc converters, however, can be costly and complex, while the performance of single-stage converters is compromised due to a reduced number of components. Several researchers have therefore proposed adding some sort of auxiliary circuit consisting of a second switch and some passive elements to single-stage converters to improve their performance. Although these modified single-stage converters may have two converters, they are not two-stage converters as they do not have two separate and independently controlled converters that are always operating to convert power from one form to another. In this paper, the operation of ac-dc single-stage converters is first reviewed and their strengths and weaknesses are noted. The operation of several modified single-stage converters, including one proposed by the authors, is then discussed, and the paper concludes by presenting experimental results that confirm the feasibility of the proposed converter.

An Open Circuit Fault Diagnostic Technique in IGBTs for AC to DC Converters Applied in Microgrid Applications

  • Khomfoi, Surin;Sae-Kok, Warachart;Ngamroo, Issarachai
    • Journal of Power Electronics
    • /
    • 제11권6호
    • /
    • pp.801-810
    • /
    • 2011
  • An open circuit fault diagnostic method in IGBTs for the ac to dc converters used in microgrid applications is developed in this paper. An ac to dc converter is a key technology for microgrids in order to interface both distributed generation (DG) and renewable energy resources (RES). Also, highly reliable ac to dc converters are necessary to keep converters in continuous operation as long as possible during power switch fault conditions. Therefore, the proposed fault diagnostic method is developed to reduce the fault detection time and to avoid any other fault alarms because continuous operation is desired. The proposed diagnostic method is a combination of the absolute normalized dc current technique and the false alarm suppression algorithm to overcome the long fault detection time and fault alarm problems. The simulation and experimental results show that the developed fault diagnostic method can perform fault detection within about one cycle. The results illustrate that the reliability of an ac to dc converter interfaced with a microgrid can be improved by using the proposed fault diagnostic method.

교류 전압 제어기에 의한 유도전동기의 효율 개선에 관한 연구 (A Study on the Efficiency Improvement of Induction Motor with AC Voltage Controller)

  • 이승철;정승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 추계학술대회 논문집 학회본부
    • /
    • pp.137-139
    • /
    • 1991
  • This paper proposes a minimum power factor control for maximum efficiency operation of an induction motor, under low load condition. Minimum input or maximum efficiency operation is achived by properly adjusting the amplitude of the stator voltage, with the three phase AC voltage controller. Through the simulation, the relationships between the delay angle and input power under various load conditions are examined. Experimental results are also given, which show good coincidence with the simulation results.

  • PDF