• Title/Summary/Keyword: AC model

검색결과 842건 처리시간 0.028초

단층 초전도케이블 샘플에서 교류손실의 수치해석에 대한 연구 (A Study on Numerical Analysis of the AC Loss in a Single-layer Superconducting Cable Sample)

  • 이주영;마용호;류경우;황시돌
    • 한국전기전자재료학회논문지
    • /
    • 제22권7호
    • /
    • pp.606-611
    • /
    • 2009
  • AC loss is one of the important factors for commercialization of a high temperature superconducting (HTS) cable from an economic point of view. But AC loss characteristics of the HTS-cable are not elucidated completely because of its complex structure. As an earlier stage of analyzing the AC loss in the 22.9 kV/50 MVA, 100m HTS-cable system of Korea Electric Power Corporation (KEPCO) which is now in collaboration with us, a two-dimensional (2D) numerical model, which takes into account the nonlinear conductivity properties of a high temperature superconductor, has been developed. In order to examine our 2D model, we have prepared several single-layer cable samples whose AC losses are sufficiently reliable due to their simple structure. The AC losses of the samples were experimentally investigated and then compared with our 2D model. The results show that the numerically calculated AC losses are not in good agreement with the measured ones for the cylindrical cable and deca-cable samples with low critical current density. However, the numerically calculated and measured AC losses are relatively in good agreement for the deca-cable and hex-cable samples with high critical current density, although the difference between these two loss data in the deca-cable sample tends to increase in the low current region.

A study on the AC and PMI model for the Defense computer network

  • 윤희승;김상천;송주석
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2001년도 추계학술발표논문집 (하)
    • /
    • pp.977-980
    • /
    • 2001
  • This paper is a study on the AC and PMI model for the defense computer network. It is suggested that the organization plan of PMI model is a proper model for the characteristics of military system and military defense network security demands based on defense PKI system. Futhermore, it will be presented both various types of defense AC and AC according to the role and clearance in PMI. Defense AC will provide strong users' authentication and Role Based Access Control to give more secured and trusted authentication service by using users' attribute such as role and clearance.

  • PDF

AC/DC 하이브리드 선로의 전기환경특성 예측을 위한 축소모델 개발 (A Development of Reduced-scale Model to Predict of Environmental Characteristics of AC/DC Hybrid Overhead Transmission Line)

  • 최인혁;신구용;이동일;임재섭;김영홍;맹종호;주문노
    • 전기학회논문지
    • /
    • 제61권5호
    • /
    • pp.676-682
    • /
    • 2012
  • To review application of HVDC (High Voltage Direct Current) transmission line to HVAC T/L in operation, reduced-scale model was designed and manufactured. The arms of model were designed to change height and interval of conductors. Electrical environmental interferences were estimated by various configuration of AC 345kV and DC 250kV T/L. The interferences such as electric field intensity and ion current density were measured and converted reduced-scale factor to full-scaled. Additionally, effects between AC and DC T/L were studied.

AC loss of HTS magnet for AMR refrigerator using magnetic field formulation and edge element in cylindrical coordinates

  • Kim, Seokho;Park, Minwon;Jeong, Sangkwon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권1호
    • /
    • pp.29-34
    • /
    • 2013
  • AMR (Active Magnetic Regenerative) refrigerators require the large variation of the magnetic field and a HTS magnet can be used. The amount of AC loss is very important considering the overall efficiency of the AMR refrigerator. However, it is very hard to estimate the precise loss of the HTS magnet because the magnetic field distribution around the conductor itself depends on the coil configuration and the neighboring HTS wires interact each other through the distorted magnetic field by the screening current Therefore, the AC loss of HTS magnet should be calculated using the whole configuration of the HTS magnet with superconducting characteristic. This paper describes the AC loss of the HTS magnet by an appropriate FEM approach, which uses the non-linear characteristic of HTS conductor. The analysis model is based on the 2-D FEM model, called as 'magnetic field formulation and edge-element model', for whole coil configuration in cylindrical coordinates. The effects of transport current and stacked conductors on the AC loss are investigated considering the field-dependent critical current. The PDE model of 'Comsol multiphysics' is used for the FEM analysis with properly implemented equations for axisymmetric model.

AC 서보 전동기 시스템의 상태공간 모델 식별에 관한 연구 (A Study on State-Space Model Identification of AC Servo Motor System)

  • 이태훈;김상환;송봉철;원충연;이상석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.199-204
    • /
    • 2000
  • Generally, The systems are so complex that it not possible to obtain reasonable model using physical insight. Also a model based on physical insight contains a number of unknown parameters even if the structure is derived from physical laws. To solve these problems, the systems identification is described in this paper. So, AC servo motor system which has both open loop and closed loop is selected as an example for identification. A state-space model of AC servo motor system is identified through open loop experiment and identified through closed loop experiment and using pole placement integral controller to open loop system. As the results, From ARMA model, We have obtained continuous-time state space model.

  • PDF

CEREC$^{(R)}$ AC system으로 채득된 디지털 인상의 재현성, 정확성 평가에 관한 연구 (Reliability, accuracy of evaluations obtained from CEREC$^{(R)}$ AC system digital impression: an in-vitro study)

  • 김재홍;김기백;김혜영;김정애;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제34권2호
    • /
    • pp.121-128
    • /
    • 2012
  • Purpose: The aim of this study was to determine the reliability and accuracy of measurements in digital models(CEREC$^{(R)}$ AC) compared to stone models. Methods: A master model(500B-1, Nissin Dental Product, Japan) with the prepared upper full arch tooth was used. Conventional impression and then stone model(n=10) were produced from this master model, and on the other hands, digital impressions were made with the CEREC$^{(R)}$ AC intra-oral scanner(n=10). One examiner measured two times the intercanine, intermolar distance, dental arch length. The stone model were measured using a digital caliper. The t-student test for paired samples and intraclass correlation coefficient(ICC) were used for statistical analysis. Results: The measurement of two methods showed very good reliability. At the intra-examiner reliability of measurement, ICC at the stone and CEREC$^{(R)}$ AC model were 0.81 and 0.94. The mean difference between measurements made directly on the stone models and those made on the CEREC$^{(R)}$ AC model was 0.20~0.28mm, and was statistically significant(P=0.001). Conclusion: These in vitro studies show that accuracy of the digital impression is similar to that of the conventional impression. These results will have to be confirmed in further clinical studies.

회로 및 수식 기반의 혼합 모델링 기법을 이용한 7상 영구자석 브러시리스 교류전동기의 시뮬레이션 모델 (Simulation model of 7 Phase Brushless AC Motor Using Mixed Modeling Technique Based on Circuit and Equations)

  • 목형수;김상훈
    • 산업기술연구
    • /
    • 제27권A호
    • /
    • pp.149-155
    • /
    • 2007
  • The counter emf(electromotive forces) of a permanent magnet multi-phase brushless motor is generally a non-sinusoidal wave or a non-ideal trapezoid. So, conventional modeling using a sinusoidal wave or an ideal trapezoid counter emf can result in errors. In order to reduce modeling errors for simulation and analysis the properties of a multi-phase brushless AC motor, this paper proposes a phase variable model that is a mixed modeling technique using both Finite Element Analysis(FEA) based circuits and motor voltage equations. The phase model parameters including the counter emf voltage waveform are obtained by using of FEA, and the mixed modeling technique based on circuits and equations is used to implement a simulation model for multi-phase brushless AC motors with any counter emf voltage waveforms. Adequacy of the proposed model is established from the simulation and experimental results for a seven-phase brushless motor.

  • PDF

Automatic Bone Segmentation from CT Images Using Chan-Vese Multiphase Active Contour

  • Truc, P.T.H.;Kim, T.S.;Kim, Y.H.;Ahn, Y.B.;Lee, Y.K.;Lee, S.Y.
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권6호
    • /
    • pp.713-720
    • /
    • 2007
  • In image-guided surgery, automatic bone segmentation of Computed Tomography (CT) images is an important but challenging step. Previous attempts include intensity-, edge-, region-, and deformable curve-based approaches [1], but none claims fully satisfactory performance. Although active contour (AC) techniques possess many excellent characteristics, their applications in CT image segmentation have not worthily exploited yet. In this study, we have evaluated the automaticity and performance of the model of Chan-Vese Multiphase AC Without Edges towards knee bone segmentation from CT images. This model is suitable because it is initialization-insensitive and topology-adaptive. Its segmentation results have been qualitatively compared with those from four other widely used AC models: namely Gradient Vector Flow (GVF) AC, Geometric AC, Geodesic AC, and GVF Fast Geometric AC. To quantitatively evaluate its performance, the results from a commercial software and a medical expert have been used. The evaluation results show that the Chan-Vese model provides superior performance with least user interaction, proving its suitability for automatic bone segmentation from CT images.

AC서보모터-볼스크루 구동 사출장치의 힘 동기제어 (Force Synchronizing Control for AC Servomotor-Ball Screw Driven Injection Unit)

  • 조승호
    • 드라이브 ㆍ 컨트롤
    • /
    • 제12권2호
    • /
    • pp.14-20
    • /
    • 2015
  • This paper focuses on the issue of force synchronizing control for the injection servomechanism of injection molding machines. Prior to the controller design, a virtual design model was developed for the injection mechanism with an AC servomotor-ball screw. A synchronizing controller is designed and combined with the PID control to accommodate the mismatches between the real plant and the linear model plant used. Due to the plant uncertainty, the stiffness and the damping of the mechanism were considered. From the tracking control simulations based on the virtual design model, it is shown that a significant reduction in force synchronizing error is achieved through the use of a proposed control scheme.

고온 초전도 모델 케이블의 임계전류 및 교류손실 특성 (Critical Current and AC loss Characteristics of mini-model HTS cable)

  • 김해준;심기덕;김재호;조전욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.809-810
    • /
    • 2006
  • Reduction of AC losses is very important for realizing HTS cable and it had been reported that the same layer current controlled by twisting pitch and direction could reduce the AC losses effectively. During the long-term development of HTS cables, the superconductor AC losses will need to be reduced to a level determined by the economics of each installation and the efficiency of the refrigeration. Theoretical models have been developed to predict the magnitude of the losses in cables composed of several layers of flat HTS tapes. This paper is manufactured mini-model HTS cable and voltage signal line to spiral shape. Mini-model HTS cable is composed of 13 HTS tape. We measured to critical current and AC loss and compared used lock-in-amp to cancel coil. This data is useful to HTS cable of DAPAS program.

  • PDF