• 제목/요약/키워드: AC corona discharge

검색결과 51건 처리시간 0.024초

교류 코로나 방전시 주파수 변화에 따른 전기유체역학적 특성 (Electrohydrodynamic Characteristics of AC Corona Discharge for the Frequency)

  • 정재승;김진규
    • 조명전기설비학회논문지
    • /
    • 제26권12호
    • /
    • pp.87-92
    • /
    • 2012
  • In this paper, EHD(electrohydrodynamics) characteristics of AC corona discharge for the various frequency was investigated. Ionic wind velocity is controlled by the frequency of applied ac high voltage, and maximum velocity of the ionic wind is obtained at 1.2kHz. Maximum velocity are 1.90 m/s by metal corona electrode and 2.72m/s by wet porous corona electrode, These attain 91~99% of the maximum velocity in the DC corona discharge by adjusting the frequency through the experiments. In this paper, wet porous corona electrode has high possibility of cooling methode because a AC corona discharge using wet porous corona electrode is able to eject more water droplets than DC corona discharge.

AC와 DC 코로나 처리에 따른 폴리에스테르 직물의 접착성질 비교 (The Comparison of Adhesion Properties on Polyester Fabric by AC and DC Corona Treatment)

  • 이재호
    • 접착 및 계면
    • /
    • 제17권3호
    • /
    • pp.104-109
    • /
    • 2016
  • AC 코로나와 DC 코로나 처리 효과들을 비교하기 위해 선행연구의 DC 코로나 처리 조건들과 같이 폴리에스테르 직물들을 전류세기 5, 10, 15 A로, 공급속도 5, 10, 15 m/min로 AC 코로나 처리하였다. 이들의 표면변화를 주사전자현미경(SEM)과 X-ray 광전자분석기(XPS)로 확인하였고, 또한 물리적 성질의 변화를 건조 시와 습윤 시의 접착강도를 통하여 측정하였다. 대기압에서 AC 코로나 방전처리에 의해 폴리에스테르 직물의 표면변화는 DC 코로나 방전과 유사한 경향을 보였다. 일반적으로 AC, DC 코로나 처리 양쪽에서 건조 시의 접착강도는 전류세기와 공급속도가 증가할수록 증가하였으나, 습윤 시의 접착강도는 전류세기가 증가할수록 공급속도가 감소할수록 증가하였다. 전류가 20 A일 때 DC 코로나 방전에서는 탄화가 발생하였으나 AC 코로나에서는 탄화가 발생하지 않았다.

오염물질에 따른 변압기부싱 모델의 기중 코로나 방전 특성 (Corona Discharge Characteristics of Transformer Bushing Model with Contaminnations in Air)

  • 방만식;김우진;김영석;김상현
    • 조명전기설비학회논문지
    • /
    • 제26권5호
    • /
    • pp.91-96
    • /
    • 2012
  • The surface of bushing is contaminated with rain, dust, salt and others. A bushing with contaminations in air is serious problem in insulation. Therefore, it is important to understand the inspection and diagnoses of the safety. The ultra-violet rays(UV) camera has attracted interest from the view point of easy judgement. In this paper, we will report on the corona discharge characteristics of surface flashover model with contaminations in air. Also, UV images of discharge and corona pulse count in air are analyzed using prototype UV camera of Korea and a UV sensor with an optic lens. These results are studied at both AC and DC voltage under a non-uniform field.

장기 코로나 처리에 따른 RTV 실리콘 절연재료의 특성변화 (Effect of Long-term Corona-discharge on RTV Silicone Rubber)

  • 연복희;안종식;허창수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.266-269
    • /
    • 2001
  • This paper investigated the aging characteristic under long-term corona discharge on roan temperature vulcanized silicone rubber, which has been using as a protective coating material for solving the contaminant problem. The applied electrical field is 10kV/cm ac and corona discharge treatment was applied on RTV silicone rubber sheet for maximum 250 hours. With the duration of corona discharge. the diffusible low molecular weight species increased, which was determined the usage of n-hexane extraction method. In addition, the contaminant layer was formed on the treated surface, and then measured the contact angle. We investigated the relation of contact angle and diffusible low molecular weight species. It is found that scissor of main chain PDMS and side chains $(CH_3)$ and the generation of LMW species were occurred by a corona discharge. The improvement of hydrophobicity rate is thought due to the increase of diffusible LMW species.

  • PDF

장기 코로나 처리에 따른 RTV 실리콘 절연재료의 특성변화 (Effect of Long-term Corona-discharge on RTV Silicone Rubber)

  • 연복희;안종식;허창수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.266-269
    • /
    • 2001
  • This paper investigated the aging characteristic under long-term corona discharge on loon temperature vulcanized silicone rubber, which has been using as a protective coating material for solving the contaminant problem. The applied electrical field is 10kV/cm ac and corona discharge treatment was applied on RTV silicone rubber sheet for maximum 250 hours. With the duration of corona discharge, the diffusible low molecular weight species increased, which was determined the usage of n-hexane extraction method. In addition, the contaminant layer was formed on the treated surface, and then measured the contact angle. We investigated the relation of contact angle and diffusible low molecular weight species. It is found that scissor of main chain PDMS and side chains (CH$_3$) and the generation of LMW species were occurred by a corona discharge. The improvement of hydrophobicity rate is thought due to the increase of diffusible LMW species.

  • PDF

AE센서를 이용한 유중 코로나방전점 위치 및 주파수 영역 검출 (Location and Frequency Domain Detection of Corona Discharge Point in Oil Using AE Sensor)

  • 이상우;김성훈;김인식;김기채;박원주;이광식;이동인
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.127-131
    • /
    • 1999
  • In this paper, using a wide-band AE sensor with the frequency range from 100[kHz], the frequency spectra of AE signals generated from the corona discharges of the needle-plane electrode was analyzed to determine the proper ultrasonic sensor. We also examined the relationship between the magnitude of corona discharge and the magnitude of AE signals in peak-to-peak value under the application of 60[Hz] AC high-voltage in oil. From these results, the main frequency spectra of AE signals emitted from the corona discharges of the needle-plane gap were found to be 130[kHz] by the fast fourier transform. The magnitude of AE signals was proportional to the magnitude of corona discharge and discharge current pulse with increasing the applied voltages. Also the detection of corona discharge point location by AE signals was found to be possible by using two sensors.

  • PDF

강유전체 충진 선대선 방전갭의 코로나 방전 및 오존 발생특성 (Corona Discharge and Ozone Generation Characteristics of a Wire-to-Wire Gap with a Ferroelectric Pellet Bed)

  • 신정민;배창환;안창진;이종훈;문재덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1873-1875
    • /
    • 2003
  • Surface corona discharge characteristics of a ac corona charged ferroelectric pellet barrier have been investigated experimentally. Electric charged stored on the surfaces of the ferroelectric pellets by a at corona discharge provide partial electric fields on the surfaces of the ferroelectric pellets, which could generate surface corona discharges on the ferroelectric pellets. This system utilizes both the surface discharges on the ferroelectric pellet barrier and the corona discharge between wire electrodes. As a result, in the case of the corona discharge with the ferroelectric pellet barrier, the mean corona current and ozone generation increase greatly, and the surface discharges on the ferroelectric pellets can be generated efficiently. It is also found that, the ferroelectric pellet barrier discharge reactor had better discharge characteristics for plasma generation than the wire-to-wire discharge reactor without pellets.

  • PDF

중첩 방전 반응기에 의한 NOx의 분해 특성 (The Characteristics of Decomposition of NOx by Superposing Discharge Plasma Reactor)

  • 선상권;우인성;황명환;박동화;조정국
    • 조명전기설비학회논문지
    • /
    • 제13권4호
    • /
    • pp.32-37
    • /
    • 1999
  • 본 연구에서는 연소공정에서 발생하는 NOx를 제거하기 위해 연면방전과 AC Corona 방전을 중첩해서 특수설계 제작된 중첩방전 반응기의 방전분해 특성을 연구하였다. 실험은 SPCP, Corona Discharge 및 중첩방전에 대한 NOx의 분해율을 비교 측정하였다. 실험변수는 방전형태, 가스의 농도, 방전주파수, 가스의 유량 등에 대하여 측정하였다. 실험결과 중첩방전에 의한 NOx의 분해율은 SPCP방전고 Corona방전에 의한 분해율보다 10∼15[%] 증가하였고 소모전력도 10[%] 정도 작게 소모되었다. 중첩방전시 상부전극의 주파수의 영향은 주파수가 작을수록 NOx의 분해율이 높았고 하부전극의 SPCP만의 방전시에는 주파수가 높을수록 NOx의 분해율이 증가하였다. 방전형태에 대한 NOx의 최대분해율은 SPCP일 때 방전전력 18[W]에서 80[%] 이었고 AC코로나 방전일 때 방전전력 805[W]에서 10[%] 이었으나 중첩방전의 경우는 14[W]에서 90[%]로 중첩방전의 효과는 10[%]이상 증가하였다.

  • PDF

핀-핀 형 또는 판-판 형 전극에 인가된 AC 전기장이 에틸렌 정상 확산 화염 Soot 입자 배출에 미치는 영향 (Effects of AC Electrostatic Field Applied to fin-to-Pin/Plate-to-Plate Electrodes on Soot Reduction in a C2B4 Normal Diffusion Flame)

  • 이재복;황정호
    • 대한기계학회논문집B
    • /
    • 제26권8호
    • /
    • pp.1062-1068
    • /
    • 2002
  • In our previous study, it was proven that the mean size and the total number concentration of carbon soot particles emitted from a $C_2$H$_4$ normal diffusion flame decreased when a DC corona was discharged to pin-pin electrodes. In this work the effect of AC corona discharge on soot emission was investigated and compared with that of DC corona discharge. For the pin-pin electrodes the size of soot particles and the number concentration decreased by the AC voltage. There were only slight changes in size distribution with frequencies, while the magnitude of applied voltage was constant. When the electric field was applied to plate-plate electrodes, the size and the number concentration also decreased with the applied AC voltages. For applied voltages above 2kV the effect of frequency increase on the soot emission was effective.

강유전체층을 갖는 선대선 방편 플라즈마장치의 코로나 방전 및 오존발생 특성 (Corona Discharge and Ozone Generation Characteristics of a Wire-to-Wire Plasma Reactor with a Ferroelectric Pellet Layer)

  • 문재덕;신정민;한상옥
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권7호
    • /
    • pp.377-381
    • /
    • 2004
  • A discharge plasma reactor using a ferroelectric pellet packed bed is now used as a removal means of pollutant gases, such as NOx, SOx and VOCs. When an ac voltage is applied to this plasma reactor, then the pellets are polarized, and great electric fields are formed at each top and bottom contact points of the ferroelectric pellets. Thus the points of each pellet become covered with intense corona discharges, where an electrophysicochemical reaction is taking place strongly However these strong discharges also elevate the temperature of the pellets greatly and concurrently decrease the output ozone generation, as a result, the overall removal efficiency of gas becomes decreased greatly A new configuration of discharge plasma reactor using a ferroelectric pellet layer and a wire-to-wire electrode has been proposed and investigated experimentally. It is found that an intensive microdischarge is taking place on the surface of ac corona-charged ferroelectric pellet layer of the proposed reactor, which concurrently enhances the efficiency of plasma generation greatly And, this type of configuration of plasma reactor utilizing a wire-to-wire electrode and a ferroelectric pellet layer could be used as one of effective plasma reactors to remove pollutant gas.