• 제목/요약/키워드: AC breakdown voltage

검색결과 248건 처리시간 0.032초

전극 간격에 따른 공기의 절연파괴 특성에 관한 연구 (A Study on the Electrical Breakdown Characteristics of Air according to Electrode Gap)

  • 강종오;이온유;김준일;방승민;이홍석;이종득;강형구
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.301-306
    • /
    • 2014
  • Recently in accordance with the rapid development of the industrial society, the accidents caused by dielectric breakdown have been increasing in power grid. It is important to prevent the dielectric breakdown of a high voltage apparatus to reduce the damage from electrical hazards. To establish an electrically reliable database of insulation design criteria for high voltage apparatus, a study on dielectric characteristics test is indispensable. In this study, dielectric characteristics according to field utilization factors (${\xi}$) which are represented as the ratio of mean electric field to maximum electric field are investigated. the dielectric breakdown experiments by using several kinds of electrode systems made with stainless steel are performed by AC breakdown voltage under air-insulation. Also, the experimental results are analyzed by the Weibull distribution. As a result, it is found that the dielectric characteristics of air-insulation are determined by ${\xi}$ as well as arrangement of electrode systems. It is considered that the results of this study would be applicable to designing the air-insulated high voltage apparatuses.

DGEBA/MDA/GN 계에서 AC 트링열화의 온도의존성 (Temperature Dependence of AC Treeing Deterioration in DGEBA/MDA/GN System)

  • 안현수;심미자;박수길;김상욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.425-428
    • /
    • 1996
  • Treeing deterioration which is one of the main cause of breakdown in insulating materials is affected by temperature, applied voltage and frequency. In this study, GN was introduced to improve impact strength of DGEBA/MDA system and the temperature dependence of AC treeing deterioration in this system was investigated. Dielectric breakdown strength decreased with the increment of temperature. As temperature increased, the growth rate of tree Increased.

  • PDF

교류 전기장이 인가된 층류 자유제트유동의 특성에 관한 예비 조사 (Preliminary Tests on the Characteristics of Free Jet Flow with Applying Electric Fields)

  • 김경택;이원준;박정;권오붕
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.191-194
    • /
    • 2014
  • The characteristics of laminar free jet flow with having applied AC electric fields have been investigated experimentally. A single electrode configuration was adopted such that electric fields were applied directly to nozzle and thus the surrounding could be an infinite ground. The experimental results showed that the jet flow with AC was modified significantly. At a certain axial distance, the laminar fuel stem was broken down and subsequently it was separated into three parts when AC electric fields were applied over a certain voltage in a range of frequencies less than 120 Hz. The breakdown point was measured by varying applied AC voltage and frequency. The effect of applying electric fields to jet flow was discussed in detail.

  • PDF

AC Loss를 고려한 22.9kV급 Mini-Model 변압기의 절연 설계 및 시험 (Insulating Design and Test of 22.9kV Class Mini-Model Transformer Considering AC Loss)

  • 백승명;정종만;곽동순;김해종;석복렬;김상현
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권8호
    • /
    • pp.420-424
    • /
    • 2004
  • This paper presents experimental data from model windings with different arrangement of coil in order to provide information to design a 22.9kV class HTS transformer. Before experiment, the composite insulation of two different type of HTS transformers are investigated. The first basic of investigation is a breakdown characteristic of liquid nitrogen and flashover characteristic on the GFRP surface under ac and impulse, The second investigation is insulation design, manufacture and test of model windings. These include a AC withstand voltage test of 50 kV rms and a lighting impulse test of 150 kV at peak.

금속입자 오손시 $SF_6$가스의 절연파괴특성 (Breakdown Characteristics of $SF_6$ Gas under Particle Contaminated Conditions)

  • 김민규;문인욱;김익수;이형호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.465-468
    • /
    • 1995
  • The gas-insulated switchgear(GIS) has made high-reliability, high-safety, compact substations possible by using $SF_6$ gas. They are likely to be further developed toward higher voltages and targer capacities, along with greater compactness and lower cost. Although $SF_6$ gas has excellent insulation performance, breakdown voltages are reduced by the conducting particles. Thus, extensive studies have been made on the breakdown characteristics of $SF_6$ gas in particle contaminated conditions. Experiments were carried out for fired particle and free particle in a coaxial electrode system with DC and AC voltages. This paper represents the experimental results of the processes involved in electrical breakdown in compressed $SF_6$ gas, where breakdown is initiated by conducting particles.

  • PDF

와이블 분포를 이용한 에폭시 복합체의 수명시간 예측 (An Estimation of Life Time in Epoxy Composites Using Weibull Distribution)

  • 오현석;이동규;장인범;박건호;김용주;이준웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.360-363
    • /
    • 1997
  • The method of estimating life time of epoxy composites which be widely used for transformers has been studied in this paper. The breakdown properties of specimens are observed by appling high AC voltage at the room temperature from a series of the experiments. Afterwards, the breakdown time was determined under the constant voltage below the lowest breakdown voltage. Also, V-t properties were found out using weibull distribution widely used in the applications of discrete data for estimating life time of epoxy composites and life exponent n was gained properly. when life exponent is gained is found out, the tong breakdown life time at used voltage can be estimated from breakdown experiments in short time using reverse law of n power.

  • PDF

Effect of Nanosilica on the Mechanical Properties and AC Electrical Breakdown Strength of Epoxy/Microsilica/Nanosilica Composite

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권6호
    • /
    • pp.301-304
    • /
    • 2012
  • Epoxy/microsilica (65 phr)/nanosilica (0~5 phr) composites (EMNC) were prepared in order to develop a high-voltage insulation material, where phr means parts per hundred relative to the epoxy oligomer. Tensile and flexural tests of the composites were carried out, and the AC electrical breakdown strength was measured, after which all the data were estimated by Weibull statistical analysis. As the nanosilica content increased, the tensile strength increased, and the highest value was 117.7 MPa in the EMNC system with 3 phr nanosilica, which was ca. 10% higher than that of the system without nanosilica. The value then decreased after 3 phr. The flexural strength and AC electrical breakdown strength showed the same tendencies as the tensile strength. The highest value of the flexural strength was 184.6 MPa in the EMNC system with 3 phr of nanosilica, which was ca. 15% higher than that of the system without nanosilica. The strongest value of the AC electrical breakdown strength was 79.0 kV/0.5 mm in the EMNC system with 3 phr of nanosilica, which was ca. 34% higher than that of the system without nanosilica.

대기중 연소화염에 의한 교류 플래시오버전압의 저하 특성 (Reduction Characteristics of AC Flashover Voltage by Combustion Flames under Atmospheric Conditions)

  • 김인식
    • 한국전기전자재료학회논문지
    • /
    • 제14권12호
    • /
    • pp.1041-1047
    • /
    • 2001
  • In this paper, reduction characteristics of the ac flashover voltage in the horizontal air gap of sphere-sphere/needle-needle electrode system were investigated when the combustion flame was present near the high-voltage electrodes. The voltage and current waveforms were measured, when the flashover is occurred, in order to examine the flashover polarity by flame. The reduction characteristics of ac flashover voltage were discussed with the thermal ionization process, the relative air density and the deflection phenomena in the shape of flames that changed by the corona wind and coulomb\`s force. As the results of an experimental investigation, It was found that the reduction of flashover voltages in sphere-sphere system, in comparison with the no-flame case, are 79.9 [%] for k=0, 82.9 [%] for k=0.5, 87.5 [%] for k=1.0, 85.0 [%] for h=0 [cm], 40.8 [%] for h=5 [cm] and 28.2 [%] for h=9 [cm] when ac voltage is applied.

  • PDF

연소화염 존재 시 모델 전력선의 절연파괴 특성 (Breakdown Characteristics of a Model Power Line in the Presence of Combustion Flame)

  • 김인식
    • 조명전기설비학회논문지
    • /
    • 제20권10호
    • /
    • pp.164-171
    • /
    • 2006
  • 본 연구에서는 연소화염이 존재할 때, 상용주파수 교류 및 직류 고전압에 대한 모델전력선의 절연파괴특성을 조사한 결과를 보고하였다. 화염높이와 위치에 따라 절연내력은 크게 저하되며, h=0에서 교류 및 직류 절연파괴전압은 화염이 없는 경우보다 최대 80[%] 저하되는 것으로 나타났다. 또한 화염위치가 k=0.5일 때 화염높이에 대한 영향도 조사하였으며, 교류전압 인가 시 h=0, 3, 6, 9 및 12[cm]로 변화시킨 경우, 화염이 없는 경우의 절연파괴전압에 비해 각각 78.6[%], 59.7[%], 46.9[%], 41.5[%] 및 35.4[%] 저하된 것으로 나타났다.

강유전체에서의 전계분포 및 절연파괴 (Dielectric Breakdown and Electric Stress Distribution in Ferroelectrics)

  • 신병철;김호기
    • 한국세라믹학회지
    • /
    • 제24권4호
    • /
    • pp.392-396
    • /
    • 1987
  • Pure barium titanate was sintered at $1340^{\circ}C$ for 2, 4, 8, 16 hr to control their grain size. The measurements of breakdown strength and partial discharge characteristics were performed under rising AC voltage(60Hz). With increase of sintering time, the average grain size was increased and breakdown strength was slightly decreased. Partial discharge in pores was observed under high voltage, and a model of dielectric break down in barium titanate ceramics is proposed.

  • PDF