• Title/Summary/Keyword: AC breakdown voltage

Search Result 248, Processing Time 0.03 seconds

Multi-layered Effect for the Insulation Design of a HTS Cable (고온초전도 케이블의 절연설계를 위한 적층효과)

  • Kwag, Dong-Soon;Cheon, Hyeon-Gweon;Kim, Hae-Jong;Cho, Jeon-Wook;Chung, Soon-Yong;Kim, Sang-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.10
    • /
    • pp.950-955
    • /
    • 2005
  • For the insulation design of a high temperature superconducting(HTS) cable, three kinds of design method were proposed, which used AC and impulse withstand voltage and partial discharge inception strength. However, the designed insulation thickness by AC and impulse could not be applied to cable fabrication process due to much low electrical breakdown strength. The effect of the multi-layered insulation paper was not considered on the previous insulation design and the insulation thickness by partial discharge inception strength could be applied only. In this paper, the electrical breakdown characteristic, which considered the effect of multi-layered of LPP, was investigated to design the insulation thickness.

Characteristics of Dissipation Factor in High Voltage Motor Stator Windings (고압전동기 고정자 권선의 유전정접 특성)

  • Kim, Hee-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.93-94
    • /
    • 2008
  • Diagnostic tests were performed in three high voltage motors. These tests included insulation resistance, polarization index, ac current, dissipation factor($tan{\delta}$) and partial discharge magnitude. The rewind of motor stator insulation at rated voltage is assessed by the results of these tests. After completing the diagnostic tests, the stator windings of motors were subjected to gradually increasing ac voltage, until the insulation punctured. NO.1 and No.2 motors failed near rated voltage of 14.0 kV, respectively. These motors are lower that expected for good quality coils in 6.6 kV class motors. The breakdown voltage of No.3 motor was 15.0 kV.

  • PDF

The Electrical Characteristics of MPPF for Capacitor Applications under AC condition (커패시터용 MPPF의 교류전압 인가시 전기적 특성)

  • 정종욱;곽희로;박중신
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.155-159
    • /
    • 2000
  • This paper describes the self healing characteristics of metalized polypropylene film(MPPF) under ac condition. PDs were generally observed at relatively low voltage, and the PDIVs were differently varied depending on the number of pre-self healing due to void defects. Several pre-self healing events took place at lower voltage than the critical breakdown voltage of PPF. Self healing mainly occurred at pin tips, wrinkle sides, and cross points of wrinkles. The applied voltage at self healing was increased with PPF thickness. The burn out area at self healing was also increased with the applied voltage and PPF thickness. The peak currents in a grounding conductor at self healing was also increased with the applied voltage.

  • PDF

Analysis of AC Breakdown Voltage accoding to epoxy thickness of Composite Insulation for Dry-Air/Epoxy under non-uniform electric field (불평등전계에서의 건조공기/에폭시 복합절연물의 에폭시 두께에 따른 AC 파괴전압 분석)

  • Heo, Jun;Lee, Seung-Su;Lim, Kee-Joe;Jung, Hae-Eun;Kang, Seong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.113-114
    • /
    • 2008
  • The purpose of this paper is to analyze AC Breakdown of solid/air composite insulation depending on the thickness and the pressure of dry air for eco-friendly insulation. SF6 gas has been widely used in electric equipment as gas insulation because of high dielectric strength and arc extinguishing performance. However, because SF6 gas is one of the green house effect gases, alternative insulation such as SF6 mixture, extremely low temperature gas, vacuum, liquid and solid insulating are being investigated.

  • PDF

AC Breakdown Analysis of Composite-Insulation by the Thickness of epoxy and the Variation of Pressure (복합절연물내 기체의 압력 및 고체의 두께변화가 AC 절연파괴에 미치는 영향 분석)

  • Jung, Hae-Eun;Kim, Byoung-Chul;Yun, Jae-Hun;Kang, Seong-Hwa;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.194-195
    • /
    • 2007
  • $SF_6$ gas used widely as insulating component in electric power industry has excellent in insulation and arc extinguishing performance in gas-insulated switchgear. However, the concern about eco-friendly alternative gas is currently rising because $SF_6$ gas is one of the main greenhouse gases. In this paper, dry-air and composite-insulation (dry-air+epoxy) as the alternative technology for $SF_6$ gas insulation is studied. Under the gas pressure ranged from 0.1 to 0.6MPa, the breakdown voltage of dry-air were measured in AC electric field. The data of composite-insulation were acquired by changing the thickness of epoxy used in each composite-insulation under the same condition.

  • PDF

Electrical Insulation Design of a 154kV-Class HTS Power Cable

  • Choi, Jin-Wook;Kwag, Dong-Soon;Choi, Jae-Hyeong;Kim, Hae-Jong;Cho, Jeon-Wook;Kim, Sang-Hyun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.2
    • /
    • pp.25-28
    • /
    • 2009
  • A 154kV class high-temperature superconducting (HTS) power cable system is developing in Korea. For insulation design of this cable, it is important that study on cryogenic electrical insulation design to develop the cold dielectric type HTS cable because the cable is operated under the high voltage environment in cryogenic temperature. Therefore, this paper describes a design method for the electrical insulation layer of the cold dielectric type HTS cable adopting the partial discharge-free design under ac stress, based on the experimental results such a ac breakdown strength, partial discharge inception stress, $V_{ac}$-t characteristics, $V_{imp}$-n characteristics, and impulse breakdown strength of liquid nitrogen/laminated polypropylene paper (LPP) composite insulation system in which the mini-model cable is immersed into pressurized liquid nitrogen.

The Effect on Breakdown of the Conducting Particles Between Coaxial Cylindrical Electrodes in $SF_6$ Gas ($SF_6$ 가스 동축원통전극 내의 금속이물이 절연파괴에 미치는 영향)

  • 조국희;권동진;이강수;곽희로
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.2
    • /
    • pp.85-90
    • /
    • 1998
  • This paper describes the breakdown characteristics of GIS by the free conducting particles under alternating voltage. If the conducting particles are present within the GIS, they can cause decrease in breakdown voltages. Various materials and sizes of free conducting particles were used to study the liftoff electric field and breakdown voltage. The measured lift-off electric fields were compared with the calculated ones for copper, steel and aluminium wire-type conducting particles. As an experimental result, it is shown that the breakdown voltages of the GIS chamber with conducting particles were lower than those without conducting particles, and were markedly dependent on the particle material and the particle sizes. Free conducting particles are important factor in particle-triggered breakdown of the GIS.he GIS.

  • PDF

Breakdown Characteristics and Lifetime Estimation of Rubber Insulating Gloves Using Statistical Models

  • Kim, Doo Hyun;Kang, Dong Kyu
    • International Journal of Safety
    • /
    • v.1 no.1
    • /
    • pp.36-42
    • /
    • 2002
  • This paper is aimed at predicting the life of rubber insulating gloves under normal operating stresses from relatively rapid test performed at higher stresses. Specimens of rubber insulating gloves are subject to multiple stress conditions, i.e. combined electrical and thermal stresses. Two modes of electrical stress, step voltage stress and constant voltage stress are used in specimen aging. There are two types of test for electrical stress in this experiment: the one is Breakdown Voltage (BDV) test under step voltage stress and thermal stress and the other is lifetime test under constant voltage stress and temperature stress. The ac breakdown voltage defined as the break-down point of insulation that leakage current excesses a limit value, l0mA in this experiment, is determined. Because the very high variability of aging data requires the application of statistical model, Weibull distribution is used to represent the failure times as the straight line on Weibull probability paper. Weibull parameters are deter-mined by three statistical methods i.e. maximum likelihood method, graphical method and least squares method, which employ SAS package, Weibull probability paper and FORTRAN, respectively. Two chosen models for predicting the life under simultaneous electrical and thermal stresses are inverse power model and exponential model. And the constants of life equation for multistress aging are calculated using numerical method, such as Gauss Jordan method etc.. The completion of life equation enables to estimate the life at normal stress based on the data collected from accelerated aging test. Also the comparison of the calculated lifetimes between the inverse power model and the exponential model is carried out. And the lifetimes calculated by three statistical methods with lower voltage than test voltage are compared. The results obtained from the suggested experimental method are presented and discussed.

Analysis on Insulation and Protection Characteristics of Grid Connected ESS in Ground/Short-Circuit Fault (지/단락실증시험에서 MW급 계통연계형 ESS 절연/보호시스템 성능 분석에 관한 연구)

  • Kim, Jin-Tae;Lee, Seung-Yong;Park, Sang-Jin;Cha, Han-Ju;Kim, Soo-Yeol
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.2
    • /
    • pp.119-122
    • /
    • 2020
  • With recent ESS (Energy Storage System) fire accident, the fault protection performance is becoming more important. However, there has never been any experiments with the protection performance on the faults in the ESS system level. In this study, the effect of AC ground fault and IGBT (Insulated Gate Bipolar mode Transistor) short-circuit failure on MW class ESS was performed experimentally for the first time in the world. First of all, the effect of the AC single line ground fault on battery was analyzed. Moreover, the transient voltage was investigated as a function of the battery capacity and the power level. Finally, the breaking capability and insulation performance of ESS were examined under PCS short-circuit fault condition. Through the tests, it was found that ESS protection system safely blocked the faulty current regardless of the faults, whereas the electronic parts such as IGBT and MC (Magnetic Contactor) were broken by the fault current. Also, the electrical breakdown in ESS resulted from the transient voltage during the protection process.

Observation of Light-Propagation along the Tube of Cold Cathode Fluorescent Lamp (냉음극 형광램프의 광 전파)

  • Cho, Y.H.;Jin, D.J.;Kim, J.H.;Han, S.H.;Cho, G.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.2
    • /
    • pp.114-126
    • /
    • 2011
  • The light propagation along a long positive column has been observed in a cold cathode fluorescent lamp. The optical signals are observed with the DC and AC voltage power during lamp operation. The light propagating is observed in the operation with the DC-rippled voltage as well as the AC-voltage. The optical signals propagate from the high voltage side to the ground. These signals show two kinds of features according to the before and after Townsend breakdown. At the dark current before Townsend breakdown, the optical intensity is damped and the propagation velocity is $10^4{\sim}10^5m/s$. At the high current of normal glow after Townsend breakdown, the propagation velocity is 1$10^5{\sim}10^6m/s$ without damping.