• 제목/요약/키워드: AC arc

검색결과 135건 처리시간 0.024초

옥외용 LED 조명의 전기화재 위험성 평가기법에 관한 연구 (A Study on the Electrical Fire Risk Assessment Methods of LED Lightings for Outdoor)

  • 김향곤;김동욱;최효상
    • 전기학회논문지
    • /
    • 제60권3호
    • /
    • pp.674-679
    • /
    • 2011
  • In this paper, we experimented and analyzed about electric fire risk assessment methods of LED lightings for outdoor. LED lighting is composed of AC power lines, AC/DC converter, DC power lines and LED lamps. There are some risk factors of electric fire in LED lighting such as short circuit between power lines or power line and ground, dielectric breakdown, leakage current, abnormal voltage inflow, poor contacts(connections), etc. As a result of this study, insulation coverings of wire was ignited due to dielectric breakdown between power lines and molten marks were formed in copper conductor. LED lighting was blown out while short circuit, beside that, electrical disorder did not occur. When abnormal voltage was inflowed, electronic components such as varistor, condenser were damaged. Partial heating was produced and insulation was melted and carbonized by arc and heating while poor contacts were happened. We expect that the results of this study would be helpful for electrical safety of LED lightings for outdoor.

초미소간격(超微小間隔)과 극단(極端)펄스방전(放電)을 이용(利用)한 미연소탄소립자(未燃燒炭素粒子) 소각제거기술(燒却除去技術) 개발기초연구(開發基礎硏究)(I) (초미소간격(超微小間隔)의 방전현상(放電現象)) (A Basic Study on a New Type Particulate Emission Control Means of a Power Station Using a Micro-Gap and a Pulse Discharge (Micro-Airgap Discharge Phenomena))

  • 문재덕;신수연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.605-608
    • /
    • 1993
  • Breakdown characteristics of a small rod-to-rod microairgap has been studied for obtain an optimum breakdown voltage and an airgap spacing to be used as an emission control means by the electrical arc-burning unburnt carbon particulates exhausted from a power station burner. It is found that the breakdown voltage at the rod-to-rod airgap spacing in the rang of $1{\sim}100{\mu}m$ decreased with decrease in the rod-to-rod airgap spacing. And there were no minimum breakdown voltage on a $V_b$-Pd characteristics which is known as the minimum voltage in Paschen's law in air atmosphere. Breakdown voltages of the airgap at the constant airgap spacing were $V_{b-dc}>V_{b-ac}>V_{b-pulse}$, and it was lowest for the pulse voltage applied. As a result, it is found that a pulse power was one of effective power compared with dc or ac to be used as such an unburnt carbon particulate emission control means and the airgap spacing became to several tens ${\mu}m$, then the breakdown voltages were down to several handreds voltages.

  • PDF

불평등 전계에서 $SF_6/CF_4$ 혼합가스의 절연내력과 PD특성 (Breakdown Voltage and PD Characteristics of $SF_6/CF_4$ Mixtures in Nonuniform Field)

  • 황청호;성허경;허창수
    • 전기학회논문지
    • /
    • 제57권4호
    • /
    • pp.635-640
    • /
    • 2008
  • New gas mixtures are now finding applications such as interrupting media for high-voltage circuit breakers. These mixtures consist of a high content of carbon tetrafluoride($CF_4$) added to sulfur hexafluoride($SF_6$). Nowdays $SF_6$ has been established for the use in gas insulated substations due to its high insulation withstand level and good arc quenching capability. At this paper Breakdown characteristics were investigated for $SF_6/CF_4$ mixtures when AC voltage and standard lightning impulse voltage(LI) was applied in a needle-plane electrodes. And partial discharge(PD) experiments were carried out in the test chamber which was made in needle-plane electrode. And ${\Phi}$-Q-N distribution of partial discharge signals was analyzed. The total pressure of the $SF_6/CF_4$ mixtures was varied within the range of 0.1-0.5 Mpa in the test chamber. The breakdown voltage in needle-plane electrode displayed N shape characteristics for increasing the content of $SF_6$ at positive impulse voltage and the PD inception voltage was increased slightly when pressure of $SF_6/CF_4$ Mixtures was increased. Maximum PD inception voltage is showed in 80% SF6/20%$CF_4$.

직류 철도용 MOV 병렬연결 1,800V급 IGBT 직류 고속차단기 연구 (IGBT DC Circuit Breaker with Paralleled MOV for 1,800V DC Railway Applications)

  • 한문섭;이장무;김주락;창상훈;김인동
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.2109-2112
    • /
    • 2016
  • The rate of rise of the fault current in DC grids is very high compared to AC grids because of the low line impedance of DC lines. In AC grids the arc of the circuit breaker under current interruption is extinguished by the zero current crossing which is provided naturally by the system. In DC grids the zero current crossing must be provided by the circuit breaker itself. Unlike AC girds, the magnetic energy of DC grids is stored in the system inductance. The DC circuit breaker must dissipate the stored energy. In addition the DC breaker must withstand the residual overvoltage after the current interruption. The main contents of this paper are to ${\cdot}$ Explain the theoretical background for the design of DC circuit breaker. ${\cdot}$ Develop the simulation model in PSIM of the real scaled DC circuit breaker for 1,800V DC railway. ${\cdot}$ Suggest design guidelines for the DC circuit breaker based on the experimental work, simulations and design process.

직렬아크의 발생 조건과 관련된 교류전원의 특성 해석 (Characteristics Analysis of AC Power Source related to Conditions of Series-Arc Generation)

  • 권완성;변병주;서현욱;방선배;김종민;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.34-35
    • /
    • 2011
  • 전기화재의 주요 원인 중 하나인 아크를 검출 및 차단하기 위한 장치로서 아크차단기(AFCI)가 사용되고 있으며 이는 UL1699에서 규정되고 있다. 본 논문에서는 UL1699에서 정의되는 직렬아크의 발생 조건에 따라 아크발생장치를 이용하여 아크를 발생시키고 부하를 변화시켜 아크가 일어날 경우의 교류전원의 특성을 해석하였다.

  • PDF

경량화를 위한 수직 다관절로봇 매니퓰레이터의 해석 (Analysis of Aticulated Robot Manipulator to Reduce Body's Weight)

  • 최원홍;김태기;이의훈;최만수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1993년도 추계학술대회 논문집
    • /
    • pp.575-581
    • /
    • 1993
  • This paper deals with analysis of articulated robot manipulator used for Arc welding and Material handling. Compared with present robot of which weight holding capacity is 6kg, this robot shows wider and symmetric working range for it's serial type mechanism. The link length is determined to have widest working range by using optimal simulation. To reduce body's weight, small AC servo motor is adopted and driving peak torque exerted at each joint is reduced by using dynamic analysis. So it is possible to reduce body's weight by 40% compared with the same class's robot and get wider working range. And by adopting modular design concept, each axis is designed to be changed easily for user's special need and repair.

  • PDF

틸팅열차(TTX)의 정장품 성능평가 연구 (A Study on Performance Evaluation of On-board Electric Device of TTX(Tilting Train Express))

  • 한성호;이수길;서승일
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 추계학술발표대회 논문집
    • /
    • pp.239-242
    • /
    • 2005
  • This paper introduced an approach of improvement of performance of Electric device for EMU type Train like as TTX. The electric equipments are characterized by insulation, Noise, cooling system etc. and Their weight arc decided by these factors. There are two kinds of power source in EMU train. First, DC voltage source, 1500 volt, 750 volt is used for subway system. Second, AC power source 25000 volt is applied to high speed train and existing main lines. Composite material has the protection of inrush current and high frequency noise. We can use this material to minimize weight of train. Additionally we can get energy saving when operator service TTX.

  • PDF

전기철도 절연구분장치의 효율적 운용에 관한 연구 (A Study on Efficient Operation of Dead Section in Electric Railway)

  • 박정균;최현영;류형선;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.416-418
    • /
    • 2001
  • In the feeding system of electric railways it is necessary to divide the power lines for either ac or dc system. At this dead section, the system is damaged by the abrupt change of the coming-in power. This paper present the relationships. Between the feeding system and the trail-cars, and the counter plans to reduce the electrical arc and the breakdown at the dead section.

  • PDF

선대 평판형 플라즈마 반응기에서 NOx 제거에 미치는 자계의 영향 (Effect of Magnetic Field on NOx Removal for Wire-Plate Plasma Reactor)

  • 박재윤;손성도;한상보;이동훈;김종달;문영훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2251-2252
    • /
    • 1999
  • In this paper, the effect of magnetic field was measured on NOx removal characteristics for wire-plate plasma reactor with magnetic field applied to electric field vertically. NOx from simulated diesel engine flue gas are decomposed by the corona discharge of DC, AC and Pulsed voltages in wire-plate reactor. Consumption power increased with increasing discharge voltage. When magnetic field was applied to electric field vertically, consumption power decreased. NOx removal rate and arc transition voltage of plasma reactor with magnetic field were higher than those of plasma reactor without magnetic field.

  • PDF

2축 서보시스템을 위한 위치제어장치 설계 (Design of a Position Controller for Two Axis Servo System)

  • 장석호;김기택;김형중
    • 산업기술연구
    • /
    • 제11권
    • /
    • pp.115-124
    • /
    • 1991
  • In this study, we design a position controller for two axis servo system. The position controller performs numerical control(NC)to DC or AC servo motor or step motor, and also has a digital input/output sequence capability. The control program composed of position and sequence command, which is called channel, is programmed easily and user-interactively. And it is interpreted and the straight line and arc position command is interpolated. We develop the Z80 microprocessor based system and the software with assembly and C language, and also PC based graphic simulator for the debugging and educational purposes.

  • PDF