• Title/Summary/Keyword: AC Plasma

Search Result 533, Processing Time 0.028 seconds

The effects of reduction of acupuncture techniques of five evolutive phase for appling excess in the heart, kidney on blood pressure, cardiac hypertrophy, plasma renin and ANP in hypertensive rat induced by two kidney one clip (2K1C 고혈압(高血壓) 백서(白鼠)의 모델에 대한 심실(心實),신실증( 腎實證) 오행(五行) 사법(瀉法) 자침(刺鍼)이 혈압(血壓) 및 혈장(血漿) Renin, ANP에 미치는 영향(影響))

  • Youn, Dae-Hwan;Wang, Kuk-Hwan;Han, Jeong-Hee;Park, Hyun-Jeong;Na, Chang-Su
    • Korean Journal of Acupuncture
    • /
    • v.22 no.1
    • /
    • pp.75-84
    • /
    • 2005
  • Objectives : Acupuncture has been used as treatment of disease in the korean medicine. In this study, it was investigated that effects of reduction of acupuncture techniques of five evolutive phase for appling excess in the heart, kidney on cardiovascular system as blood pressure and renin and atrial natriuretic peptide (ANP) in plasma, cardiac hypertrophy. Materials and methods : The experiments were performed on Sprague Dawley rats, 2K1C hypertension model was prepared by constricting the left renal artery with a sliver clip. Animals were then divided into seven groups, 2K1C induced and no treated group (Control), acupuncture on SP3 HT7(AC-1), LR1 KI1 (AC-2), SP3 HT7 LR1 KI1 (AC-3). The treatments were performed once a day for 10 days in rats. Results : The results are that the blood pressure was significantly decreased at 15days in AC-1 group. The cardiac hypertrophy was significantly decrease in AC-3 group. The activity of plasma ANP was increased in all groups without AC-1 group and the that of plasma Rein was decrease in AC-1, AC-2 groups than control group. Conclusions : These results suggest that acupuncture at SP3 HT7 and SP3 HT7 LR1 KI1 can be used as a therapy for controlling renal hypertension induced by 2K1C in the rats.

  • PDF

Measurement of Electron Temperature and Plasma Density in Coplanar AC Plasma Display Panels.

  • Cho, Il-Ryong;Moon, Min-Yook;Ryu, Chung-Gon;Choi, Myung-Chul;Choi, Eun-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.748-751
    • /
    • 2003
  • The electron temperature and plasma density in coplanar alternating-current plasma display panels (AC-PDPs) have been experimentally investigated by a micro Langmuir probe and the high speed discharge images in this experiment.

  • PDF

AC Plasma Display Panel with Irregular Micro-scale Holes in the Front Dielectric Layer

  • Cho, Kwan-Hyun;Ahn, Sung-Il;Kim, Woo-Hyun;Choi, Kyung-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.711-712
    • /
    • 2009
  • The fabrication of micro-scale irregular holes by using PMMA (Poly Methyl Methacrylate) beads in the front dielectric layer was proposed to improve luminous efficacy of an ac plasma display panel. Through the firing process of front dielectric layer, bowl shaped holes with a depth of $2.5{\mu}m$, a top diameter of $8-12{\mu}m$, and a bottom diameter of $4-7{\mu}m$ were fabricated. The proposed ac plasma display panel with the irregular micro-scale holes improved the luminous efficacy by 18 % due to the decrease in the minimum sustain voltage.

  • PDF

Binary and ternary gas mixtures of He-Ne-Xe for improvement of vacuum ultraviolet luminous efficiency in ac-PDPs.

  • Jung, Kyu-Bong;Lee, Jun-Ho;Park, Won-Bae;Jeon, Wook;Oh, Phil-Young;Cho, Guang-Sup;Uhm, Han-Sup;Choi, Eun-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.522-524
    • /
    • 2004
  • The improvement of luminance and luminous efficiency is the one of the most important part in AC-PDPs. To achieve high luminance and luminous efficiency, high VUV emission efficiency is needed. We measured the emission spectra of vacuum ultraviolet(VUV) rays in surface discharge AC-PDP with binary and ternary gas mixtures of Ne-Xe and He-Ne-Xe. The influence of He-Ne-Xe gas-mixture ratio on excited $Xe^{\ast}$ resonant atoms and $Xe_2$$^{\ast}$ dimers has been investigated. It is found that luminous efficiency of ternary gas mixture, He-Ne-Xe, is shown to be much higher than that of binary gas mixture of Ne-Xe.

  • PDF

Characteristics of Non-Thermal Plasma Process for Air Pollution Control (대기오염 물질 저감을 위한 저온 플라즈마 반응공정의 특성)

  • 송영훈;신동남;신완호;김관태;최연석;최영석;이원남;김석준
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.3
    • /
    • pp.247-256
    • /
    • 2000
  • Basic characteristics of non-thermal plasma process to remove C2H4 and NO have been experimentally investigated with a packed-bed type reactor and an ac power supply. The performance of the non-thermal plasma generated by ac power supply was compared with that of a wire-plate type reactor equipped with a pulsed power supply. The result shows that the non-thermal plasma can be effectively generated with an AC power supply that can be easily fabricated with conventional techniques. In order to understand the basic reaction mechanisms of the non-thermal plasma process, parametric tests for different carrier gases(air and nitrogen) and for different reaction pathways have been performed. The test results show that O3 generated by non-thermal plasma plays an dominant role to oxidize C2H4 and NO over N and O radicals when these pollutant gases are carried by dry air under room temperature condition. Experimental observations, however, indicate that N and O radicals can significantly affect on the removal process of the pollutant gases under certain conditions.

  • PDF

Stabilization of Plasma in a Three-Phase AC Plasma Generator (삼상 교류 플라즈마 발생의 안정화)

  • Lee, K.H.;Kim, K.S.;Lee, H.S.;Rim, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.209-211
    • /
    • 2002
  • A simple-structured thermal plasma generator for waste gas treatment has been studied. The thermal plasma technology applied to waste treatment has undoubtedly gained high importance owing to its outstanding properties such as flexibility, compact reactor, and clean treatment. Moreover, the thermal plasma generated by ac power has some additional advantages such as simple electrode system and easy maintenance. A prototype 200kW class plasma generator with specifications of 10-30m/sec gas velocity and 3000-5000K temperature on the center just outside of the nozzle has been designed and tested. Case studies on heat transfer, heat flow, velocity distribution, and temperature distribution using a commercial simulation package show lots of flexibility in design. The experimental results from theprototype generator show that the ac thermal plasma is easily controlled by working gas flow once it is ignited. A stabilization condition is discussed with the data from monitoring arc voltage drops with respect to gas flow rate during the test.

  • PDF

A Study On High Power Factor Sine Pulse Type Power Supply For Atmospheric Pressure Plasma Cleaning System with 3-Phase PFC Boost Converter (3상 PFC 부스트 컨버터를 채용한 상압플라즈마 세정기용 고역률 정형파 펄스 출력형 전원장치에 관한 연구)

  • Han, Hee-Min;Kim, Min-Young;Seo, Kwang-Duk;Kim, Joohn-Sheok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.72-81
    • /
    • 2009
  • This paper presents quasi-resonant type high power factor ac power supply for atmospheric pressure plasma cleaning system adopting three phase PFC boost converter and it's control method. The presented ac power supply consists of single phase H-bridge inverter, step-up transformer for generating high voltage and three phase PFC boost converter for high power factor on source utility. Unlikely to the traditional LC resonant converter, the propose one has an inductor inside only. A single resonant takes place through the inside inductor and the capacitor from the plasma load modeled into two series capacitor and one resistance. The quasi-resonant can be achieved by cutting the switching signal when the load current decrease to zero. To obtain power control ability, the propose converter controlled by two control schemes. One is the changing output pulse period scheme in the manner of PFM(Pulse Frequency Modulation) control. On the other, to provide more higher power to load, the DC rail voltage is directly controlled by the 3-phase PFC boost converter. The significant merits of the proposed converter are the uniform power providing capability for high quality plasma generation and low reactive power in AC and DC side. The proposed work is verified through digital simulation and experimental implementation.

Metabolism and Pharmacokinetics of S-(N,N-Diethyldithiocar-bamoyul)-N-acetyl-L-cysteine in Rats

  • Lee, Byung-Hoon;Song, Yun-Seon;Park, Jongsei;Ryu, Jae-Chun
    • Archives of Pharmacal Research
    • /
    • v.17 no.6
    • /
    • pp.428-433
    • /
    • 1994
  • The methabolism and phamacokinetics of a mixed disulfide S-(N, N-diethyldithiocarbamoyl)-N-acetyl-L-cysteine (AC-DDTC) were studied in rats. Two metabolites of AC-DDTC following iv and po administration were indentified in plasma and liver by HPLC and GC, namely N, N-diethyldithiocarbamate (DDTC) and the methyl ester of DDTC (Me-DDTC). AC-DDTC was very unstable in vivo and could not be detected neither in plasma nor in urine. Pharmacokinetic parameters of DDTC following intravenous administration of AC-DDTC (20 mg/kg) were calculated. DDTC has a low affinity to rat tissue and the body clearance was $9.0{\pm}3.4mkl/mim/kg$. The mean residence time (MRT) was $11.5{\pm}16.3 min$. After oral administration of 20 mg/kg AC-DDTC, maximal plasma concenttion ($C_{max}$) was $3.8{\pm}0.2 nmol/ml$ and the bioavailability was 7.04%. $C_{max}$ for DDTC at a dose of 120 mg/kg. AC-DDTC was $40.1{\pm}2.2 nmol/ml$. ART was $47.1{\pm}2.8min$.at a dose of 20 mg/kg and $110.5{\pm}6.0 min$ at 120 mg/kg.

  • PDF

Influence of gas mixture He-Ne-Xe on the vacuum ultraviolet intensity in ac-PDPs.

  • Yoo, N.L.;Jung, K.B.;Lee, J.H.;Lee, S.B.;Han, Y.K.;Jeong, S.H.;Lee, H.J.;Son, C.G.;Lim, J.E.;Oh, P.Y.;Moon, M.W.;Jeoung, J.M.;Ko, B.D.;Cho, G.S.;Uhm, H.S.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1221-1224
    • /
    • 2005
  • The improvement of luminance and luminous efficiency is the one of the most important parts in AC-PDPs. To achieve high luminance and luminous efficiency, high VUV emission efficiency is needed. We measured the emission spectra of the vacuum ultraviolet(VUV) rays in surface discharge AC-PDP with ternary gas mixture of He-Ne-Xe. The influence of He-Ne-Xe gas-mixture ratio on excited $Xe^{\ast}$ resonant atoms and $Xe_2\;^{\ast}$ dimers has been investigated. It is found that luminous efficiency of ternary gas mixture, He-Ne-Xe, is shown to be much higher than that of binary gas mixture of Ne-Xe. For improving discharge luminous efficiency, we have studied VUV emission characteristics of ternary gas mixture, He(50%)-Ne-Xe and He(70%)-Ne-Xe with Xe concentration and filling gas pressure.

  • PDF

The influence of Ne-Xe gas mixture ratio on vacuum Ultraviolet and infrared line in AC-PDP

  • Oh, Phil-Y.;Cho, I.R.;Jung, Y.;Park, K.D.;Ahn, J.C.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.743-747
    • /
    • 2003
  • The improvement of luminance and luminous efficiency is the one of the most important part in AC-PDPs. To achieve high luminance and luminous efficiency, high VUV emission efficiency is needed. We measured the emission spectra of vacuum ultraviolet(VUV) and infrared(IR) rays in surface discharge AC-PDP with Ne-Xe mixture gas. The influence of Ne-Xe gas-mixture ratio on resonance state $Xe^{\ast}(3P_{1})$ and exited state $Xe^{\ast}(3P_{2})$ has been investigated. It is found that the intensity of VUV 147nm emission is proportional to that of the IR 828 nm emission, and the VUV 173nm emission is roughly proportional to that of the IR 823nm emission. The electron temperature and plasma density have been experimentally measured from the center of sustaining electrode gap by a micro Langmuir probe in AC-PDPs. The plasma density from the center of sustaining electrode gap are shown to be maximum value of $9{\times}10^{11}cm^{-3}$, where the electron temperature is about 1.6 eV in this experiment

  • PDF