• 제목/요약/키워드: AC Generator

검색결과 270건 처리시간 0.026초

이동식 에너지 뱅크용 대용량 배터리 충전 시스템의 개발 (Development of the High Power Battery Charging System for Portable Energy Banks)

  • 김수연;김동옥;이정환;박성준
    • 한국산업융합학회 논문집
    • /
    • 제24권4_2호
    • /
    • pp.491-499
    • /
    • 2021
  • Batteries are widely used for energy storage, such as ESS(Energy Storage System), electric vehicles, electric aircraft, and electric powered ships. Among them, a submarine uses a high power battery for an energy storage. When the battery of a submarine is discharged, a diesel generator generates AC power, and then AC/DC power converter change AC power to DC power for charging the battery. Therefore, in order to lower the current capacity of the diesel generator, it is necessary to use an AC/DC converter with a high input power factor. And, a power converter with a large power capacity must have high stability because it can lead to a major accident when a failure occurs. However, the control algorithm using the traditional PI controller is difficult to satisfy stability and dynamic characteristics. In this paper, we design the high power AC/DC converter with high input power factor for battery charging systems. And, we propose a stable control algorithm. The validity of the proposed method is verified through simulation and experiments.

지연 고정 루프 기반의 지터 억제 클록 발생기 (A Jitter Suppressed DLL-Based Clock Generator)

  • 최영식;고기영
    • 한국정보통신학회논문지
    • /
    • 제21권7호
    • /
    • pp.1261-1266
    • /
    • 2017
  • 지연 시간 전압 분산 변환기 (DVVC) 및 평균 회로 (AC)가 있는 지터 억제 지연 고정 루프 (DLL) 기반 클록 발생기를 제안하였다. 제안한 클록 발생기는 지연고정루프에서 무작위로 발생하는 지터와 회로의 구조에 의해 발생하는 지터를 억제하도록 하였다. 지연 시간 전압 분산 변환기는 각 지연단의 지연 차이를 감지하고 출력 전압을 생성한다. 평균회로는 두개의 연속되는 지연 시간 전압 분산 변환기의 출력 전압을 평균화 한다. 지연 시간 전압 분산 변환기 및 평균 회로는 연속적인 지연단의 지연 시간을 평균화하고 모든 지연단의 지연 시간을 동일하게 만든다. 또한 루프필터 출력 전압의 변동을 줄이기 위해 부궤환 기능으로 효과적인 작동을 하는 스위치가 있는 커패시터가 도입되었다. One-poly six-metal $0.18{\mu}m$ CMOS 공정으로 제작 된 DLL 기반 클록 발생기의 측정 결과는 13.4 ps rms 지터특성을 보여준다.

EDLC를 이용한 X선 투시촬영장치용 하이브리드 X선 제너레이터 (Hybrid Type X-Ray Generator Using EDLC for Fluoroscopy X-Ray System)

  • 서영민;홍순찬
    • 조명전기설비학회논문지
    • /
    • 제28권9호
    • /
    • pp.89-98
    • /
    • 2014
  • A diagnostic fluoroscopy X-ray system uses a 32kW or greater X-ray generator for obtaining real-time moving images and high-resolution images. Fluoroscopy X-ray systems have to use a high-capacity AC power source to perform long-time low-power fluoroscopy and short-time high-power spot exposure. In this paper, we propose a hybrid type X-ray generator for fluoroscopy X-ray system which can perform fluoroscopy and spot exposure with a low-capacity AC power source and an energy storage device. The characteristics of energy storage devices are compared and each energy storage device is modelled to equivalent circuit. And the characteristics of available energy are analyzed as a function of output voltage and power. A 32kW class hybrid X-ray generator with EDLC as an energy storage device for fluoroscopy X-ray system was constructed, and its validity was verified by means of simulations and experiments.

풍력-디젤-BESS 독립형 마이크로그리드 모델링 및 운전제어 알고리즘에 관한 연구 (Modeling & Operating Algorithm of Islanding Microgrid with Wind Turbine, Diesel Generator and BESS)

  • 김재언
    • 한국산학기술학회논문지
    • /
    • 제15권9호
    • /
    • pp.5893-5898
    • /
    • 2014
  • 본 논문은 연료비를 최소화 할 수 있는 2차전지 전력저장장치(BESS: Battery Energy Storage System)와 풍력-디젤 복합발전시스템으로 구성되는 독립형 마이크로그리드을 모델링하는 방법과 그 운전제어 알고리즘을 제안하였다. 먼저, 부하변동 및 풍속변동에 따른 주파수와 전압을 일정하게 제어할 수 있는 양방향 DC/AC 컨버터의 BESS를 모델링하고, 디젤발전기는 공급전력의 부족 및 BESS의 충전시에만 가동하도록 하는 운전제어알고리즘을 제안한다. 그리고, 제안된 모델링 방법과 운전제어알고리즘을 독립형 마이크로그리드에 적용한 결과, 풍속 및 부하변화에 대하여 주파수와 전압변동이 적정범위내로 유지할 수 있음을 증명할 수 있었다.

농형 유도발전기를 이용한 독립형 풍력발전시스템의 최대출력제어 (Maximum Output Power Control for Stand-Alone Wind Power Generation System Using Cage-Type Induction Generators)

  • 김형균;이동춘;석줄기
    • 전력전자학회논문지
    • /
    • 제9권1호
    • /
    • pp.73-80
    • /
    • 2004
  • 본 논문에서는 농형유도발전기를 이용한 독립형 풍력발전시스템의 최대전력 추종제어기법을 제안한다. 농형 유도발전기는 벡터제어 방식으로 동작되는데 d-축 전류에 의해 여자가 제어되고 q-측 전류에 토크가 제어된다. 이 토크제어에 의해 발전기는 풍속의 변화에 따라 최대전력을 발생하도록 가변속 제어된다. 발전된 전력은 ac/dc PWM 컨버터에 의해 직류 출력단 배터리뱅크로 충전된다. 제안된 기법은 M-G세트로 구성된 터빈시뮬레이터를 이용하여 실험적으로 검증된다.

항공기용 발전기의 설계 적합성 평가에 관한 연구 (A Study on the Compliance Evaluation for Design of an Aircraft Generator)

  • 김유광;박근영;이강이;진영권
    • 한국항공운항학회지
    • /
    • 제11권2호
    • /
    • pp.23-32
    • /
    • 2003
  • In this paper, the design data of an aircraft generator have been reviewed to evaluate the compliance with the airworthiness standards, and the technical procedure to ensure safety and reliability of an alternate-current generator by the tests and computations have been developed.

  • PDF

Improved Modification of the Closed-Loop-Controlled AC-AC Resonant Converter for Induction Heating

  • Dhandapani, Kirubakaran;Sathi, Rama Reddy
    • ETRI Journal
    • /
    • 제31권3호
    • /
    • pp.298-303
    • /
    • 2009
  • A single-switch parallel resonant converter for induction heating is implemented. The circuit consists of an input LC-filter, a bridge rectifier, and a controlled power switch. The switch operates in soft commutation mode and serves as a high frequency generator. The output power is controlled via the switching frequency. A steady state analysis of the converter operation is presented. A closed-loop circuit model is also presented, and the experimental results are compared with the simulation results.

  • PDF

풍력 발전기 여자 제어기 설계 (Wind Generator Exciter Controller Design)

  • 홍현문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1731-1732
    • /
    • 2005
  • 본 논문은 풍력발전기 안정된 출력발전을 위하여 풍력 동기발전기 여자기 설계에 중점을 두었다. 풍력발전기 최대 발전을 얻기 위해 동기발전기 속도제어와 여자제어가 필요하다. 속도제어에서 AC/DC 정류기는 전력 다이오드로 구성하고 DC/AC 인버터는 IGBT로 구성하였다. 여자제어 구성은 AC/DC는 전력 다이오드로 구성하고 DC단은 DC/DC 부스트로 구성하였다. 또한, 동기발전기 여자 제어기 제어신호에 동기발전기 출력 AC/DC의 전력과 동기발전기 속도로 적절하게 조절함으로서 안정되고 최대 출력이 되도록 하였다. 또한, 제안된 제어기가 우수한 성능을 보임을 시뮬레이션으로 증명하였다.

  • PDF

A Novel Variable-Speed Renewable-Energy Generation System of Induction Generator and PWM Converter for Small-Scale Hybrid Power Applications

  • Ahmed, Tarek;Nishida, Katsumi;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1339-1342
    • /
    • 2005
  • This paper presents a simple AC-DC power conditioner for a squirell-cage induction generator(IG) operating under variable shaft speeds. The necessary reactive power for the IG system is supplied by means of a capacitor bank and a voltage-source PWM converter. Using a capacitor bank to transfer the reactive power to the IG under the rated speed and no-load conditions starts the IG operation and reduces the PWM power converter size. A simple control compensating for changes in the electrical loads as well as the variation in speed was developed to regulate the voltages of the IG system by controlling the rotor flux through its reactive and active currents control implementation. This proposed power conditioning scheme can be used efficiently as a wind power generation system where the output voltage of the IG is maintained constant voltage despite the variable frequency and the DC bus voltage of the PWM converter can be used for either DC applications such as battery charging or AC power applications with 60/50 Hz by connecting a stand alone inverter. The experimental and simulated operating performance results of a 5 kW IG scheme at various speeds and leads are presented.

  • PDF

부스트 컨버터를 가진 정지형 여자기의 과도 안정도 해석 (TRANSIENT STABILITY ANALYSIS OF STATIC-EXCITER WITH BOOST CONVERTER)

  • 김찬기;류홍우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.204-210
    • /
    • 1997
  • The paper deals with the design and evaluation of a new static-exciter for generator excitation systems to improve the steady-state and transient stabilities. It increases or maintains the generator field current by boosting the field voltage in the case of an input AC line voltage drop during and immediately after a fault. The validity of the proposed excitation system is verified with computer simulation. The simulation results of the stability analysis on the generator with the proposed exciter is better than that of a conventional static exciter and a conventional AC exciter. Also, this proposed exciter can be simply implemented and controlled by modern power electronics technology.

  • PDF