• 제목/요약/키워드: AC Breakdown Strength

검색결과 136건 처리시간 0.032초

변압기 오일에 자성나노입자 첨가에 따른 절연파괴전압 특성변화에 관한 실험적 연구 (Experimental Study on the Dielectric Breakdown Voltage with the Addition of Magnetic Nanoparticles in a Transformer Oil)

  • 서현석;이원호;이세희;이종철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1538-1539
    • /
    • 2011
  • In this study, we have investigated the dielectric breakdown by measuring AC (60Hz) breakdown strength of the fluids in accordance with IEC 156 standard and have compared the results with references. It was found that the dielectric breakdown voltage of pure transformer oil is around 12 [kV] with the gap distance of 1.5mm between electrodes. In case of our transformer oil based magnetic fluids with 0.1% < ${\Phi}$(volume concentration of magnetic particles) <0.6%, the dielectric breakdown voltage shows above 30 [kV], which is 2.5 times higher than that of pure transformer oil. It can be explained by the changed ionization process by adding nanoparticles in pure transformer oil, which is due to trapped fast electrons and slow negative nanoparticles. Moreover, in case of the fluid with applied magnetic field, the dielectric breakdown voltage increases above 40 [kV], which is 3.3 times higher than that of pure transformer oil.

  • PDF

자켓 컴팍운드용 절연재의 수증기투과 및 절연파괴 특성 (Characterization of Water Vapor Transmission & Dielectric Breakdown in Insulation Materials for Jacket Compound)

  • 송재주;한재홍;송일근;한용희;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.52-56
    • /
    • 2001
  • Experiments of 2 type on insulating compounds accomplished to change PVC using in URD(Underground) power cable jacketing. one was DB(Dielectric Breakdown) test on the pure base resins and the others were WVT(Water Vapor Transmission) test on the compounds which contained C/B(Carbon Black), anti-oxidant to base resin. a kind of specimens made by pressing to resin of pellet or lump form was HDPE(High Density Polyethylene), MDPE(Medium Density Polyehylene), LDPE(Low Density Polyethylene), LLDPE(Linear Low Density Polyethylene), PVC(Polyvinyl Chloride). As a results of AC DB and WVT test, we saw that strength of Insulation was HDPE> LLDPE = MDP E> LDPE and WVT ratio was HDPE

  • PDF

Effect of Nano-silicate on the Mechanical, Electrical and Thermal Properties of Epoxy/Micro-silica Composite

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권3호
    • /
    • pp.153-156
    • /
    • 2012
  • In order to develop electrical insulation materials, epoxy/micro-silica composite (EMC) and epoxy/micro-silica/nano-silicate composite (EMNC) were prepared, and their tensile and flexural strength, AC insulation breakdown strength and thermal conductivity and thermal expansion coefficient were compared. Nano-silicate was prepared in an epoxy matrix by our AC electric field process. All properties of the neat epoxy were improved by the addition of micro-silica, which was improved much further by the addition of nano-silicate to the EMC system.

수직배열 모델 전력선의 절연파괴 특성에 미치는 화염의 영향 (Influence of Combustion Flame on Breakdown Characteristics of Vertical-Model Power Lines)

  • 박광서;김인식
    • 조명전기설비학회논문지
    • /
    • 제22권4호
    • /
    • pp.85-92
    • /
    • 2008
  • 많은 나라에서 가공 송전선로 아래에서 발생된 산불에 의해 계통 섬락사고를 일으키고 있다. 본 연구에서는 상용주파수 교류 및 직류 고전압을 인가하였을 때, 연소화염에 의해 전력선의 절연강도가 저하하는 특성을 조사하기 위해 수직배열 전력선에 대한 모의조건에서 다양한 실험을 수행하였다. 실험 결과, 화염이 없는 경우에 비해 연소 화염이 존재하면 화염의 거리(h)에 따라 절연파괴전압은 크게 저하되는 것으로 나타났다. 도체와 화염의 거리(h)가 작을수록 절연파괴전압이 감소하였으며, 교류전압 인가 시, h=9[cm]일 때 평균 46.2[%], h=3[cm]일 때 평균 62.5[%] 저하된 것으로 나타났다.

Double Pancake Coil형 고온초전도 변압기의 전기적 절연 특성 (Dielectric Insulation Properties of Double Pancake Coil Type HTS Transformer)

  • 백승명;정종만;이현수;한철수;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제16권2호
    • /
    • pp.151-156
    • /
    • 2003
  • High temperature superconductor can only be applied against an engineering specofication that has to be determined for each particular application form the design requirements for economic viability and for operation margins in service. However, in order to realize the HTS transformer, it is necessary to establish the high voltage insulation technique in cryogenic temperature. Therefore, the composite insulation of double pancake coil type transformer are described and AC breakdown voltage characteristics of liquid nitrogen(LN$_2$) under HTS pancake coil electrode made by Bi-2223/Ag are studied. The Breakdown of LN$_2$ is dominated electrode shape and distance. The influence of pressure on breakdown voltage is discussed with th different electrode. For the electrical insulation design of turn-to-turn insulation for the HTS transformer, we tested breakdown strength of insulation sheet under varying pressure. And we investigated surface flashover properties of LN$_2$ and complex conition of cryogenic gaseous nitrogen(CGN$_2$) obove a LN$_2$ surface. The surface voltage of GFRP was measured as a function of thickness and electrode distance in LN$_2$ and complex condition of CGN$_2$ above a LN$_2$ surface. this research presented information of electrical insulation design for double pancake coil(DPC) type HTS transformer.

해수범람 전·후의 CSPE 특성변화 (Variation in Properties of Seawater Flooded and Non-Flooded CSPE)

  • 이정우;김인용;지성현;전황현;신용덕
    • 전기학회논문지
    • /
    • 제64권12호
    • /
    • pp.1724-1729
    • /
    • 2015
  • Chlorosulfonated polyethylene (CSPE) was not flooded seawater and flooded seawater & freshwater for 5 days, respectively, and these samples are referred to as BSF(before seawater flooding) and ASFF(after seawater & freshwater flooding), respectively. The apparent density, dissipation factor, relative permittivity, melting temperature, dielectric breakdown time and increased time of applied voltage are higher than those of BSF, but the insulating resistance, dielectric strength, percent elongation and glass transition temperature of ASFF are lower than those of BSF. The differential temperature of those is $0.026{\sim}0.028(^{\circ}C)$ after AC and DC voltage is applied to ASFF, respectively, and the differential temperature of those is $0.013{\sim}0.037(^{\circ}C)$ after AC and DC voltage is applied to BSF, respectively. In the case AC and DC voltage is applied to ASFF as well as BSF, the variations in temperature of AC voltage are higher than those of DC voltage. It is investigated that dielectric loss due to dissipation factor ($tan{\delta}$) is related to electric dipole conduction current. It is certain that the ionic (electron or hole) leakage current was increased by conducting ions such as $Na^+$, $Cl^-$, $Mg^{2+}$, $SO_4^{2-}$, $Ca^{2+}$ and $K^+$, those are related to cured atoms of O and S that relatively increased after seawater flooding.

나노반도전 미니모델케이블의 AC절연파괴특성 (AC Breakdown Strength for Mini Model Cables with Nano-Semiconductive Layer)

  • 이승원;김수환;김용현;임장섭;이건호;이원석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1183-1183
    • /
    • 2015
  • 본 연구에서는 기존 및 개발된 나노반도전에 대한 전계완화역할에 따른 전기적 특성평가를 위해 반도전 종류별로 제작된 이중압출 미니모델케이블을 이용하여 AC 절연파괴시험을 수행하여 절연파괴특성을 확인하였다.

  • PDF

실리콘 처리에 의한 수트리 열화케이블의 절연회복 (Insulation rehabilitation of water tree aged cables by silicone treatment)

  • 김주용;송일근;한재홍;이동영;문재덕
    • 조명전기설비학회논문지
    • /
    • 제14권1호
    • /
    • pp.14-21
    • /
    • 2000
  • 본 논문은 수트리 열화된 가교폴리에틸렌(XLPE) 절연 지중케이블의 절연회복을 위해 개발된 실리콘 처리 기법의 현장적용 가능성을 검토하기 위해 수트리 열화된 325 $\textrm{mm}^2$ CN/CV 케이블을 수거하여 실리콘 처리하고, 시간의 경과에 따른 절연성능 향상도를 분석한 것이다. 시료 케이블의 절연회복을 평가하기 위해 교류절연파괴시험을 실시했다. 또 실리콘 처리케이블의 평가를 위해 진단시험 및 케이블 특성평가를 수행했다. 실리콘 처리후 1년 경과 시료 케이블올 분석한 결과, 실리콘액(silicone fluid)과 수분이 효과적으로 결합해 절연파괴강도가 상당히 증가한 것으로 나타났다. 실험결과를 종합해 볼 때 수트리로 열화된 케이블의 절연성능 향상에 실리콘 처리가 효과적인 것으로 나타났다.

  • PDF

13.2kV/630A급 고온초전도 한류기의 절연설계 (Insulation Design for a 13.2kV/630A High-Tc Superconducting Fault Current Limiter)

  • 강형구;이찬주;고태국;석복렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.941-942
    • /
    • 2007
  • The superconducting fault current limiter (SFCL) consists of superconducting coil for limiting the fault current and cryogenic cooling system for keeping the coil in superconducting condition. The study on the insulation design for superconducting coil and cryogenic cooling system should be elaborately performed to develop a high voltage SFCL. In this paper, insulation design of solenoid coil for 13.2kV/630A SFCL is performed through the AC dielectric breakdown test and lightning impulse dielectric strength test. The dependence of dielectric characteristics on the magnitude of liquid nitrogen pressure is also investigated. Through the investigation, it is verified that dielectric characteristics of sub-cooled nitrogen are strongly enhanced by the pressurization. The electrical insulation design of 13.2kV/630A SFCL is performed by applying the experimental results. The successful insulation design for development of 13.2kV/630A SFCL is confirmed by AC dielectric breakdown tests.

  • PDF

6.6kV 철거 CV 케이블의 잔존 절연 특성 (Residual Insulation characteristics of long-term serviced 6.6 kV CV Cable)

  • 백주흠;김동욱;한기만
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1994년도 춘계학술대회 논문집
    • /
    • pp.46-49
    • /
    • 1994
  • In order to investigate possibility of CV cable diagnosis technique, residual insulation characteristics of .long - term serviced 0.6 kV CV Cable are examined by DC leakage current residual voltage tensile strength, cross1inking density and AC & impulse breakdown. Also effect of cable structure and water tree are reported

  • PDF