• Title/Summary/Keyword: AC 전기장

Search Result 95, Processing Time 0.024 seconds

Effect of AC Electric Fields on Counterflow Diffusion Flame of Methane (메탄의 대향류 확산화염에 대한 AC 전기장의 영향)

  • Choi, Byung-Chul;Kim, Hyung-Kuk;Chung, Suk-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.8
    • /
    • pp.849-855
    • /
    • 2012
  • The effect of electric fields on the response of diffusion flames in a counterflow has been investigated experimentally by varying the AC voltage and frequency. The result showed that the flame was stationary with high AC frequency above the threshold frequency, and it increased with the applied voltage and then leveled off at 35 Hz. Below the threshold frequency, however, the flame oscillated with a frequency that was synchronized with the applied AC frequency. This oscillation can be attributed to the ionic wind effect due to the generation of bulk flow, which arises from the momentum transfer by molecular collisions between neutral molecules and ions, where the ions in the reaction zone were accelerated by the Lorentz force.

Improvement of the Pumping Force in the Magnetic Fluid Linear Pump by AC Pulse current (AC Pulse에 의한 Magnetic Fluid Linear Pump의 펌핑력 향상에 관한 연구)

  • SEO Kang;PARK Gwan soo
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.986-988
    • /
    • 2004
  • 이 전에 DC Pulse 전류로 구동하는 Magnetic Fluid Linear Pump(MFLP)를 개발하였다. 개발된 MFLP는 DC Pulse 전류에 의하여 발생하는 자기장의 분포 변화가 불연속적이게 되고, 펌핑력 또한 불연속성을 가지게 된다. 불연속적 자기장의 변화와 펌핑력의 불균일성을 저감하였다. 펌핑력을 증가시키기 위하여 AC 전류를 이용하였으며, 이에 따른 펌프의 운전 특성을 파악하기 위하여 자기장의 분포와 자성유체의 형상을 해석하였다.

  • PDF

Experimental Study on the Effects of AC Electric Fields on Flame Spreading over Polyethylene-insulated Electric-Wire (폴리에틸렌으로 피복된 전선화염의 전파에 교류전기장이 미치는 영향에 관한 실험적 연구)

  • Jin, Young-Kyu;Kim, Min-Kuk;Park, Jeong;Chung, Suk-Ho;Kim, Tae-Hyung;Park, Jong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.11
    • /
    • pp.1015-1025
    • /
    • 2010
  • In this present study, we experimentally investigated the effects of electric fields on the characteristics of flames spreading over electric-wires with AC fields. The dependence of the rate at which a flame spreads over polyethylene-insulated wires on the frequency and amplitude of the applied AC electric field was examined. The spreading of the flame can be categorized into linear spreading and non-linearly accelerated spreading of flame. This categorization is based on the axial distribution of the field strength of the applied electric field. The rate at which the flame spreads is highly dependent on the inclined direction of the wire fire. It could be possible to explain the spreading of the flame on the basis of thermal balance.

Flow inside the Droplet in AC Electrowetting (AC 전기습윤에서 액적 내부의 유동)

  • Ko, Sung-Hee;Kang, Kwan-Hyoung
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2995-2996
    • /
    • 2007
  • We found that there exists a flow inside a droplet in AC electrowetting, which is distinct from DC electrowetting. In order to investigate the origin of the flow inside the droplet, we performed an experiment and numerical simulation. It is conjecture, based on the results of the experiment and numerical simulation, the flow is caused by the so called induced-charge electroosmosis at high frequencies, and by droplet oscillation at low frequencies.

  • PDF

Effects of AC Electrostatic Field Applied to fin-to-Pin/Plate-to-Plate Electrodes on Soot Reduction in a C2B4 Normal Diffusion Flame (핀-핀 형 또는 판-판 형 전극에 인가된 AC 전기장이 에틸렌 정상 확산 화염 Soot 입자 배출에 미치는 영향)

  • Lee, Jae-Bok;Hwang, Jeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.8
    • /
    • pp.1062-1068
    • /
    • 2002
  • In our previous study, it was proven that the mean size and the total number concentration of carbon soot particles emitted from a $C_2$H$_4$ normal diffusion flame decreased when a DC corona was discharged to pin-pin electrodes. In this work the effect of AC corona discharge on soot emission was investigated and compared with that of DC corona discharge. For the pin-pin electrodes the size of soot particles and the number concentration decreased by the AC voltage. There were only slight changes in size distribution with frequencies, while the magnitude of applied voltage was constant. When the electric field was applied to plate-plate electrodes, the size and the number concentration also decreased with the applied AC voltages. For applied voltages above 2kV the effect of frequency increase on the soot emission was effective.

Flow Characteristics of Propane Premixed Flame on AC Electric Field (교류 전기장 인가에 따른 프로판 예혼합 화염의 유동 특성)

  • Boyun Kim;Minseok Kim;Taehun Kim;Ilsong Kweon;Hyemin Kim
    • Journal of ILASS-Korea
    • /
    • v.29 no.1
    • /
    • pp.38-44
    • /
    • 2024
  • This study investigates the flow characteristics of propane-air premixed flames on AC electric field using the Schlieren method. A voltage was applied to the ring electrode and the burner was grounded to form an electric field, and the applied voltage was fixed at 16 kV (Vpp). Results show that under the application of AC electric fields, flow around the flame oscillated only at frequencies below 50 Hz, and no oscillation was observed above this frequency range. Flame height oscillated with frequency in the range of 25 to 300 Hz, with frequency doubling observed in the range of 25 to 150 Hz. The flammability limit increased with frequency up to 250 Hz, but in the high-frequency range above 250 Hz, the flammability limit did not increased and converged.

Electrical characteristics of soot particles in a LPG diffusion flame and particle size change by electric fields (LPG 확산화염내 매연입자의 전기적 특성 및 전기장에 의한 입자 크기 변화)

  • Park, Jong-In;Ji, Jun-Ho;Hwang, Jeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.10
    • /
    • pp.1326-1338
    • /
    • 1997
  • Electrical characteristics of soot particles in a LPG diffusion flame were studied for the control of soot particle coagulation. When a DC voltage was applied between two electrodes installed parallel to gas flow, ionic wind effect caused soot deposition on the cathode, implying that most of the soot particles were positively charged. Soot deposit on the cathode linearly increased and was saturated with respect to the strength of the applied voltage. The possibility of applying an AC voltage to enhance the particle coagulation was then investigated and the efficiency of the size control was checked with transmission electron microscope photographs. For the amplitude of 2 kV AC field, primary (spherical) soot particle size decreased from 30 ~ 40 nm to around 20 nm when the frequency of the applied AC voltage was 60 Hz and higher. Collisions between the soot particles in such a selected AC condition could lead to the formation of much bigger agglomerates of roughly 1-5 .mu.m in size.

Analysis of Electrical Coagulation of Unipolar Charged Particles in an Alternating Electric Using Moment Method (모멘트법을 이용한 AC 전기장 내의 단극성 입자의 전기응집 해석)

  • Ji, Jun-Ho;Hwang, Jeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.1
    • /
    • pp.9-17
    • /
    • 2001
  • A numerical study has been carried out on the evolution of the particle size distribution for unipolar charged particles that experience coagulation in an alternating electric field. The collision frequency function of charged particles was analytically derived. The log-normal size distribution function is utilized for representing a poly-disperse size distribution and the moments of the particle size distribution are used to solve the general dynamic equation considering only AC electric force effect. The results are compared with the effects of brownian coagulation.

Flame Spread Behavior near the End of Wire over Electrical-wire with Applied AC Electric Fields. (교류전기장이 인가된 전선위에서 전선 끝단 근처의 화염전파 거동)

  • Hwang, Sang Seok;Kim, Min Kuk;Park, Jeong;Chung, Suk Ho;Kwon, Oh Boong
    • 한국연소학회:학술대회논문집
    • /
    • 2012.04a
    • /
    • pp.249-252
    • /
    • 2012
  • Experiments have been conducted to clarify flame spread behavior over electrical wire near the end of wire with applied AC electric fields. It is seen that the flame spread behavior near the end of wire with applied AC electric fields are quite different from that in temporally linearly-increasing flame position. The flame spread behavior can be categorized into three regimes based on the relevance of flame shape and the slanted direction of spread flame to spread rate. Detailed explanations on the characteristics are made through thermal balance mechanism. Also, the effect of drop of molten PE and fuel vapor-jet in flame spread is also discussed.

  • PDF

Effect of Electric Fields on Reattachment of Lifted Flame at Low AC Frequency (저주파 교류 전기장 내에서의 부상화염의 재부착 특성에 관한 연구)

  • Kim, Y. K.;Ryu, S. K.;Won, S. H.;Chung, S. H.
    • 한국연소학회:학술대회논문집
    • /
    • 2007.05a
    • /
    • pp.197-201
    • /
    • 2007
  • The reattachment characteristics of propane lifted flames in laminar coflow jets influenced by AC electric fields have been investigated experimentally in low AC frequency range. The reattachment velocity and height have been measured by varying the applied AC voltage and frequency. The results showed that the reattachment of lifted flame occurred at relatively higher jet velocity with AC electric fields, comparing to that without having AC electric fields. The effect of AC electric fields became more effective at higher voltage and lower frequency in the AC frequency range larger than 30 Hz. However, in the low frequency range below 30 Hz, the reattachment velocity decreased with decreasing frequency. Consequently, there existed a transition regime, for the frequency smaller than about 30 Hz. Also, when the AC voltage was applied to the fuel nozzle at very low frequency, the reattachment process exhibited an oscillatory behavior, synchronized with the applied AC frequency.

  • PDF