• Title/Summary/Keyword: A-PDA

Search Result 1,759, Processing Time 0.031 seconds

Lecture Video Display Technique using Extraction Region of Study based on PDA (PDA 기반의 학습 영역 추출을 이용한 강의 영상 디스플레이 기법)

  • Seo, Jung-Hee;Park, Hung-Bog
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.11
    • /
    • pp.2127-2134
    • /
    • 2007
  • The electronic learning helped a learner to overcome the time restriction by providing mobility, instantly and flexibility but the restriction in connection with space on cable computer remained unsolved. Accordingly, the electronic learning has tendency to change into mobile learning environment which allows a learner to overcome time and spatial restriction. However, these mobile devices have a limitation to awareness of learning contents provided over the realtime video movie due to its small display size. Therefore, this paper suggests a technique according to the following priority: for a real time learning image, extract region of study for region of interest, rescale the real time image to its proper size suitable for the display device, and then make it displayed on a wireless PDA. As a result of the experiment, we reduced the calculating time by sampling the field centering on learning contents adaptively and computing the field best suited for device size of the user effectively.

Development of a Multi - channel Detector for Capillary Electrophoresis System (모세관 전기영동 장치용 Photodiode Array 다채널 검출기의 개발에 관한 연구)

  • Hong, Seung Guk;Kim, Hai-Dong
    • Analytical Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.96-104
    • /
    • 1998
  • A photodiode array multichannel detector system for capillary electrophoresis was developed. The photodiode array detector for capillary electrophoresis (CE-PDA) has 1024 photodetectors and can analyze sample by measuring UV/VIS absorption spectrum in 275~675 nm wavelength range. The CE-PDA instrument can get a spectrum in 30 ms during sample separation and can be programmed by a PC to control various experimental conditions required for sample analysis. The performance of the multichannel CE-PDA instrument was tested using L-ascorbic acid and alizarin yellow GG mixture. The reproducibility test of the CE-PDA system showed 5.6% RSD.

  • PDF

Design and Implementation of a Messenger Program for PDA Using UML (UML을 이용한 PDA용 메신저 프로그램 설계 및 구현)

  • Kwon, Young-Jik;Cui, Jun;Kwon, Dong-Hwoon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.15 no.5
    • /
    • pp.149-158
    • /
    • 2010
  • A messenger program in this paper was designed and implemented using Use Case Diagram, Class Diagram, Activity Diagram, and Sequence Diagram. We selected total 7 major functionalities such as PC server, login, friends management, chatting, file transfer, account management, etc. The followings are various implementation results from this paper. First, developers could easily understand the desired product and programming flow from using UML Diagrams. Second, PDA users could communicate with developers for a long time without time constraints. Third, there was high usability of UML Diagram in the phase of objected-oriented analysis. Forth, it was easy to update and maintain a program.

Polydiacetylene-Based Chemo-/Biosensor of Label Free System with Various Sensing Tools (다양한 감지 방법을 갖고 있는 폴리디아세틸렌 기반 비표지 화학/바이오센서)

  • Park, Hyun-Kyu;Park, Hyun-Gyu;Chung, Bong-Hyun
    • KSBB Journal
    • /
    • v.22 no.6
    • /
    • pp.409-413
    • /
    • 2007
  • Polydiacetylene(PDA)-based sensors possess a number of properties that can be successfully applied for label-free detection system. PDA is one of the most attractive color-generating materials, with growing applications as sensors. Here we introduce various PDA-based devices, used as biosensor, chemosensor, thermosensor, and optoelectronics sensor. In general, PDA liposomes and films are closely packed and properly designed for polymerization via 1,4-addition reaction to form an ene-yne alternating polymer chain. PDA-based two/three dimensional structures have been used for colorimetric or fluorescent devices, sensing biological as well as chemical components. This color-generating material also present a very high charge carrier mobility, allowing its application as field-effect transistor (FET). The immobilized PDA structures or films have distinct advantages for the detection of low concentration target molecules over the aqueous solution-based detection systems. In the present review, reported detection methods by using various PDA structures are summarized with updated references.

Primary Surgical Closure Should Be Considered in Premature Neonates with Large Patent Ductus Arteriosus

  • Ko, Seong-Min;Yoon, Young Chul;Cho, Kwang-Hyun;Lee, Yang-Haeng;Han, Il-Yong;Park, Kyung-Taek;Hwang, Yoon Ho;Jun, Hee Jae
    • Journal of Chest Surgery
    • /
    • v.46 no.3
    • /
    • pp.178-184
    • /
    • 2013
  • Background: Treatment for patent ductus arteriosus (PDA) in premature infants can consist of medical or surgical approaches. The appropriate therapeutic regimen remains contentious. This study evaluated the role of surgery in improving the survival of premature neonates weighing less than 1,500 g with PDA. Materials and Methods: From January 2008 to June 2011, 68 patients weighing less than 1,500 g with PDA were enrolled. The patients were divided into three groups: a group managed only by medical treatment (group I), a group requiring surgery after medical treatment (group II), and a group requiring primary surgical treatment (group III). Results: The rate of conversion to surgical methods due to failed medical treatment was 67.6% (25/37) in the patients with large PDA (${\geq}2$ mm in diameter). The number of patients who could be managed with medical treatment was nine which was only 20.5% (9/44) of the patients with large PDA. There was no surgery-related mortality. Group III displayed a statistically significantly low rate of development of bronchopulmonary dysplasia (BPD) (p=0.008). The mechanical ventilation time was significantly longer in group II (p=0.002). Conclusion: Medical treatment has a high failure rate in infants weighing less than 1,500 g with PDA exceeding 2.0 mm. Surgical closure following medical treatment requires a longer mechanical ventilation time and increases the incidence of BPD. Primary surgical closure of PDA exceeding 2.0 mm in the infants weighing less than 1,500 g should be considered to reduce mortality and long-term morbidity events including BPD.

Comparative Study between Design Methods and Pile Load Tests for Bearing Capacity of Driven PHC Piles in the Nakdong River Delta (낙동강 삼각주에 항타된 PHC말뚝의 지지력을 위한 재하시험과 지지력 공식의 비교연구)

  • Dung, N.T.;Chung, S.G.;Kim, S.R.;Chung, J.G.
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.3
    • /
    • pp.61-75
    • /
    • 2007
  • Deep foundations have been popularly installed in hard stratum such as gravels or rocks in Korea. However, it is necessary to consider sand or sandy gravel layers that locate at the mid-depths as the bearing stratum of piles in the thick Nakdong River deltaic deposits, as done in the Chaophraya (Bangkok) and Mississippi River deltas. This study was focused on the finding of suitable methods for estimating bearing capacity when driving prestressed high-strength concrete (PHC) piles to a required depth in the deltaic area. Ground investigation was performed at five locations of two sites in the deltaic area. Bearing capacity of the driven piles has been computed using a number of proposed methods such as CPT-based and other analytical methods, based on the ground investigation and comparison one another other. Five PDA (pile driving analyzer) tests were systematically carried out at the whole depths of embedded piles, which is a well-blown useful technique for the purposes. As the results, the bearing capacities calculated by various methods were compared with the PDA and static load testing results. It was found that the shaft resistance is significantly governed by set-up effects and then the long-term value agrees well with that of the $\beta$ method. Also, the design methods for toe resistance were determined based on the SLT result, rather than PDA results that led to underestimation. Moreover, using the CPT results, appropriate methods were proposed for calculating the bearing capacity of the piles in the area.

Temperature Measurements in a Microfluidic Chip with Polydiacetylene Sensor (폴리다이아세틸렌을 이용한 미세유동칩 내의 온도 측정)

  • Jang, Young-Sik;Ryu, Sung-Min;Song, Si-Mon
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2696-2699
    • /
    • 2008
  • Microfluidic chips have been frequently utilized to perform biochemical analysis, like cell culture, because they reduce the consumptions of analytes and reagents and automate multi-step analysis processes. It is often critical to monitor temperature in a microchannel for the analyses in order to control a reaction condition of bio or chemical molecules. We propose a novel method to monitor temperature of a microchannel flow by using polydiacetylene (PDA), a conjugated polymer, that has a unique property to transform its color from visible blue to fluorescent red by thermal stress. We inject PDA sensor droplets generated by hydrodynamic instability into a microchannel with a microheater incorporated on the channel bottom. Also, we change the channel temperature by providing the different electric power to the microheater. The results show that the florescence intensity of PDA sensor droplets linearly increases in response to the flow temperature increase within a certain range.

  • PDF

Preparation of Highly Active Metathesis Catalyst from Rhenium Carbonyl and its Catalysis (레늄카보닐에 의한 고활성 메타세시스 촉매제조 및 그의 촉매작용)

  • Ahn, Ho-Geun
    • Applied Chemistry for Engineering
    • /
    • v.9 no.1
    • /
    • pp.115-120
    • /
    • 1998
  • The surface chemistry of $Re_2(CO)_{10}$ deposition for preparing highly dispersed rhenium catalysts and the formation of active site for the metathesis were studied. Alumina as support was treated at 1223K(DA) and 773k(PDA), respectively. The metathesis activity of the catalysts at 298K was measured by using pure propene under atmospheric pressure. The oxidation number of rhenium on PDA was very high, and that on DA was zero-valent with highly dispersed state. The prepared Re/DA catalyst was easily activated by treating with oxygen gas at low temperatures after thermal decomposition at high temperatures. The activity of Re/DA catalyst, even with very low rhenium loading, was much higher than that of Re/PDA or conventional $Re_2O_7/Al_2O_3$ catalysts. Therefore, rhenium carbonyl was effective for preparing a highy active metathesis catalyst with very low rhenium loading. Rhenium ion on Re/DA catalyst seemed to be bonded to two oxygen atoms on DA surface, that is, two-valent. The two-valent rhenium ion was changed to about six-valent by treating with oxygen. It could be considered that propene metathesis occurred through carbene complex which was formed on the six-valent rhenium ions.

  • PDF

Individualized ibuprofen treatment using serial B-type natriuretic peptide measurement for symptomatic patent ductus arteriosus in very preterm infants

  • Shin, Jeonghee;Lee, Eun Hee;Lee, Jee Hyun;Choi, Byung Min;Hong, Young Sook
    • Clinical and Experimental Pediatrics
    • /
    • v.60 no.6
    • /
    • pp.175-180
    • /
    • 2017
  • Purpose: Plasma level of B-type natriuretic peptide (BNP), an emerging, sensitive, and specific biomarker of hemodynamically significant patent ductus arteriosus (PDA), rapidly decreases in infants receiving cyclooxygenase inhibitors for ductal closure. We investigated the usefulness of serial BNP measurement as a guide for individual identification of early constrictive responses to ibuprofen in preterm infants with symptomatic PDA (sPDA). Methods: Before March 2010, the standard course of pharmacological treatment was initiated with indomethacin (or ibuprofen) and routinely followed by 2 additional doses at intervals of 24 hours. After April 2010, individualized pharmacological treatment was used, starting with the first dose of ibuprofen and withholding additional ibuprofen doses if the BNP concentration was <600 pg/mL and clinical symptoms of PDA improved. Results: The BNP-guided group received significantly fewer doses of ibuprofen than the standard group did during the first course of treatment and the entire study period. The need for further doses of cyclooxygenase inhibitors and for surgical ligation was not significantly different between the 2 groups. No significant differences were seen in clinical outcomes and/or complications related to sPDA and/or pharmacological treatment. Conclusion: Individualized BNP-guided pharmacological treatment may be used clinically to avoid unnecessary doses of cyclooxygenase inhibitors without increasing the ductal closure failure and the short-term morbidity related to sPDA.

The Wireless Radiation Measurement Using Embedded System (임베디드 시스템에 의한 방사선의 무선계측)

  • Kim, Hyong-Jong;Park, Dae-Sung;Lee, Sang-Bock
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.1
    • /
    • pp.11-16
    • /
    • 2008
  • Radiation is used in various field, including medical science, engineering science, agricultural science and other industrial fields and the use frequency of radiation is increasing thanks to the development of radiation technology. Although radiation contributes to the mankind so much, we must pay attention to radiation damage by its influence on human body. To use radiation properly and prevent the radiation damage, it is necessary to measure radiation exactly and to practice thorough research and education on the basis of this measurement. In this study, I suggest the method to measure radiation wirelessly without the limit of time and space, not approaching radiation having a harmful effect on human body by using ubiquitous computing technology. For the realization of suggested method, the wireless transmission technology of CDMA network is used and after installing embedded system in PDA, the measurement value is displayed through accessing CDMA network with PDA in radiation measurement system of having fixed IP. If we use the proposed method of this study, we don't have to approach radiation that is harmful to the human and can read the measurement value that is marked in PDA through CDMA network by radiation measurement system of having fixed IP.

  • PDF