• 제목/요약/키워드: A-D test

검색결과 10,514건 처리시간 0.043초

Image Sticking Evaluation Methods for OLED TV Applications

  • Lee, Hun-Jung;Choi, Dong-Wook;Lee, Eun-Jung;Kim, Su-Young;Shin, Mi-Ok;Yang, Sun-A;Lee, Seung-Bae;Lee, Han-Yong;Berkeley, Brian H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1077-1080
    • /
    • 2009
  • In this paper, we propose a new method for measuring image sticking of an OLED display using a human visual test. We determined that the perceptual image sticking threshold is 2% of luminance difference at 200 nits and 1% at 100 nits, respectively. Color shift must also be considered when evaluating image sticking, as a ${\Delta}$(u', v') shift of just over 0.002 can be recognized regardless of background brightness. Perception of image sticking is affected by the background level, test pattern, and ambient illumination conditions. The evaluation standard must consider both luminance variation and color shift simultaneously.

  • PDF

펄스도플러 레이더 시험장치 개발 (A development of test and evaluation equipment for pulsed doppler radar)

  • 신현익;이정욱
    • 전자공학회논문지B
    • /
    • 제33B권7호
    • /
    • pp.154-162
    • /
    • 1996
  • The test and evaluation is a integal part of the radar development process and it consists of two parts, field test and in-house test using a standard simulated signal. To take the in-house test, the test environment is needed to generate the critical signal that is used to determine the system design parameters and consists of general urpose measurement equipments, specialized boards and operating softwares. This paper presents the in-house test environment configuration and its function for radar system. Because this test environment genrates the simulated radar signal which has arbitrary flight path and target condition, the developed test environment makes easily to evaluate the function for radar system. The program ability of test parameters makes it possible to apply a test for 2D and 3D radar system.

  • PDF

시중 즉석 조리 면의 Back Extrusion 텍스처 데이터에 대한 Partial Least Square Regression 분석 (Analysis of Partial Least Square Regression on Textural Data from Back Extrusion Test for Commercial Instant Noodles)

  • 김수경;이승주
    • 산업식품공학
    • /
    • 제14권1호
    • /
    • pp.75-79
    • /
    • 2010
  • 시중 즉석 면류의 관능적 성질과 back extrusion test 데이터에 대하여 partial least square regression(PLSR)을 실시하였다. 즉석유탕면 8종과 즉석비유탕면 2종에 대한 관능적 속성으로서 경도(A), 탄성(B), 껄끄러운 정도(C), 이에 박히는 정도(D), 굵기감(E)를 검사하였고, 실험 데이터로 힘-변형 곡선 전체를 사용하였다. PLSR의 회귀계수는 힘-변형곡선의 압착단계, 항복단계, 압출단계로 크게 구분되어 각관능속성에 대한 특유의 양 또는 음의 효과를 나타냈다. PLSR의 상관계수는 E>D>A>B>C, 오차(root mean square error of prediction expressed in sensory units)는 D>C>E>B>A, 예측능(relative ability of prediction)는 D>C>E>B>A 로 나타나 종합적으로 '이에 박히는 정도'가 PLSR의 적용에 가장 우수하게 나타났다. '경도'는 예측능은 낮았지만 상관성은 높아서 시료간 순위의 결정에 합당하게 평가되었다.

자동차 전조등 고압 방전 램프 구조 변경에 대한 연구 (A Study on the Automotive Structural Change of High Intensity Discharge Head lamp)

  • 임주헌
    • 대한안전경영과학회지
    • /
    • 제10권2호
    • /
    • pp.53-60
    • /
    • 2008
  • A test was conducted using two high density discharge lamps, the H2D and the structurally new H4D. They were tested for luminous illumination and luminous temperature in the day and night time. The test was conducted without crippling the performance of the H2D by adding a magnetic actuator, enabling it to move left to right, and up and down. By making these modifications we constructed a sample of the H4D. We compared the H2D and the H4D sample's luminous illumination and luminous temperature by using a photometer and a digital thermometer in the day and night time. We discovered that the H2D and H4D performed similarly from the data we gathered. Now we know the H4D has potential use and extensive research needs to be made to gather more detailed data.

Flow-3D를 활용한 수질정화체가 설치된 농업용 배수로의 안정성 조사 (Investigation of the Hydraulic Stability of Agricultural Drainage Channels Installed Water Purification Materials by using Flow-3D)

  • 김선주;박기춘
    • 한국농공학회논문집
    • /
    • 제49권5호
    • /
    • pp.3-9
    • /
    • 2007
  • In this study, the effect of the purification materials is analyzed and tested by Flow 3D and Hydraulic model test. Three dimension numerical analysis led from the research that sees abnormal form and the size back of the water purification material conferred the flowing water conduct inside the test channel against the test condition. Comparison it analyzed the flux distribution, a water depth of the channel which establishes the water purification materials the cross section, an interval of the water purification material, a conference with general channel, it change executed. As a result, the cross section ratio of the purification materials against and a flux change from the test which it sees. The interval of the purification materials in order to prevent three dimension that follows in decrease of increase and flux must decide an interval.

약물검사에서 관리시료의 농축을 이용한 보고 가능 범위의 설정에 대한 연구 (A Study of Reportable Range Setting through Concentrated Control Sample)

  • 장상우;김남용;최호성;박용원;윤근영
    • 대한임상검사과학회지
    • /
    • 제36권1호
    • /
    • pp.13-18
    • /
    • 2004
  • This study was designed to establish working range for reoportable range in own laboratory in order to cover the upper and lower limits of the range in test method. We experimented ten times during 10 days for setting of reportable range with between run for method evaluation. It is generally assumed that the analytical method produces a linear response and that the test results between those upper and lower limits are then reportable. CLIA recommends that laboratories verify the reportable range of all moderate and high complexity tests. The Clinical Laboratory Improvement Amendments(CLIA) and Laboratory Accreditation Program of the Korean Society for Laboratory Medicine states reportable range is only required for "modified" moderately complex tests. Linearity requirements have been eliminated from the CLIA regulations and from others accreditation agencies, many inspectors continue to feel that linearity studies are a part of good lab practice and should be encouraged. It is important to assess the useful reportable range of a laboratory method, i.e., the lowest and highest test results that are reliable and can be reported. Manufacturers make claims for the reportable range of their methods by stating the upper and lower limits of the range. Instrument manufacturers state an operating range and a reportable range. The commercial linearity material can be used to verify this range, if it adequately covers the stated linear interval. CLIA requirements for quality control, must demonstrate that, prior to reporting patient test results, it can obtain the performance specifications for accuracy, precision, and reportable range of patient test results, comparable to those established by the manufacturer. If applicable, the laboratory must also verify the reportable range of patient test results. The reportable range of patient test results is the range of test result values over which the laboratory can establish or verify the accuracy of the instrument, kit or test system measurement response. We need to define the usable reportable range of the method so that the experiments can be properly planned and valid data can be collected. The reportable range is usually defined as the range where the analytical response of the method is linear with respect to the concentration of the analyte being measured. In conclusion, experimental results on reportable range using concentrated control sample and zero calibrators covering from highest to lowest range were salicylate $8.8{\mu}g/dL$, phenytoin $0.67{\mu}g/dL$, phenobarbital $1.53{\mu}g/dL$, primidone $0.16{\mu}g/dL$, theophylline $0.2{\mu}g/dL$, vancomycine $1.3{\mu}g/dL$, valproic acid $3.2{\mu}g/dL$, digitoxin 0.17ng/dL, carbamazepine $0.36{\mu}g/dL$ and acetaminophen $0.7{\mu}g/dL$ at minimum level and salicylate $969.9{\mu}g/dL$, phenytoin $38.1{\mu}g/dL$, phenobarbital $60.4{\mu}g/dL$, primidone $24.57{\mu}g/dL$, theophylline $39.2{\mu}g/dL$, vancomycine $83.65{\mu}g/dL$, valproic acid $147.96{\mu}g/dL$, digitoxin 5.04ng/dL, carbamazepine $19.76{\mu}g/dL$, acetaminophen $300.92{\mu}g/dL$ at maximum level.

  • PDF

765kV 시험선로를 이용한 전기환경장해 특성연구 (Study on Electrical Environmental Obstacle Using a 765kV Double Circuit Test Line)

  • 김정부;조성배;신구용;이동일;양광호;안희성;배정효;구자윤;민원석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1517-1519
    • /
    • 1994
  • This paper describes electrical environmental study of a 765kV double circuit test line. Corona performance on several candidate conductor bundles has been investigated in the corona cage (single phase simulation facility) since 1984. We have known that six RAIL conductor bundle is the most suitable for the 765kV transmission Line, [3] To investigate electrical environmental impact of the future commerciale line, we build a full sacle 765kV test line in 1993. The test results of Audible Noise, Radio Interference, TV Interference from August, 1993 to Jan. 1994 were measured as $48.7[dBA](L_{50})$. $57.4[dB{\mu}V/m]$(Fair weather, $L_{50})$. $14.5[dB${\mu}$V/m]$(Fair weather, $L_{50}$). We have found that the Audible Noise data were very close to the predicted(48.5 [dBA]) by BPA Corona and Field Effects Computer program, however, the RI and TVI data were much higher than predicted(42 [dBmV/m], $7.9[dB{\mu}V/m)$ by the BPA program. We have investigating the reason of the difference. In the constructing of full scale test line, we developed the tubular tower, 765kV test transformer and hardwares of 765kV transmission line insulator strings. Also we will investigate the effects of plants under the 765kV test Line.

  • PDF

$^{18}F$-FDG를 이용한 전신 PET 검사에서 혈당 측정 검사지의 정확한 사용에 따른 혈당 수치의 차이 분석 (The Analysis of Blood Glucose Level Difference According to the Exact Use of Blood Glucose Measurement Test Strips in $^{18}F$-FDG Wholebody PET)

  • 박순기;이남기;남궁창경;정우영
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.100-103
    • /
    • 2010
  • $^{18}F$-FDG PET 검사는 포도당 대사를 이용하여 전신의 종양을 평가하는 검사로 전처치 과정에서 혈당 측정의 중요성이 매우 높다. 혈당 수치가 높은 상태에서 FDG를 투여하면 FDG와 혈중 포도당이 세포 내 흡수에 서로 경쟁하게 되고 종양으로의 FDG 섭취가 감소되어 정확한 검사가 되지 않을 가능성이 있다. 혈당 측정에 사용되는 혈당 측정 검사지는 경우에 따라 모세혈관혈 전용 측정 검사지와 모세혈관혈과 정맥혈을 모두 측정 가능한 범용 측정 검사지로 구분되어 있는데, 정확한 혈당 측정 검사지(스트립)의 사용에 따른 혈당 수치의 차이를 비교 분석 하였다. 연구 대상은 2010년 3월부터 4월까지 서울아산병원 핵의학과에서 $^{18}F$-FDG whole body PET 검사를 시행한 환자 중 46명(남자: 32명, 여자: 14명, 평균연령 $57.3{\pm}12.3$세) 을 연구의 대상으로 하였다. 실험기기는 Abbott사의 Optium Xceed혈당 측정기를 이용하였고, 모세혈관혈과 정맥혈을 모두 측정 가능한 범용 측정 검사지를 사용하여 동일 환자의 모세혈관혈과 정맥혈의 혈당 수치의 차이를 분석하였다. 또한, 모세혈관혈 전용 측정 검사지를 사용하여 동일 환자의 모세혈관혈과 정맥혈의 혈당 수치의 차이를 비교 분석하였다. 분석방법은 MINITAB 통계 프로그램을 이용하여 paired t-test 검정을 시행하였다. 모세혈관혈과 정맥혈을 모두 측정 가능한 범용 측정 검사지로 측정한 동일 환자의 모세혈관혈과 정맥혈의 혈당 수치는 각각$95.2{\pm}12.4$ mg/dL, $104.1{\pm}14.4$ mg/dL (t=8.0, p<0.001)로 통계적으로 유의한 차이가 있었다. 모세혈관혈 전용 측정 검사지로 측정한 동일 환자의 모세혈관혈과 정맥혈의 혈당 수치는 각각 $91.5{\pm}13.6$ mg/dL, $108.1{\pm}16.2$ mg/dL (t=9.2, p<0.001)로 통계적으로 유의한 차이가 있었다. 선행연구에 의하면 모세혈관혈과 정맥혈의 혈당 수치는 여러 가지 이유로 인해 차이가 있는 것으로 보고 되었고 본 연구의 결과도 유사한 차이를 확인하였다. $^{18}F$-FDG PET 검사 전에 혈당 수치를 측정할 때 모세혈관혈 전용 측정 검사지로 정맥혈의 혈당을 측정하는 것은 부정확한 혈당 수치를 측정할 수 있으므로 주의해야 할 것이다. 그러므로 적합한 측정 검사지와 규정된 측정절차를 이행하는 것이 측정 편차를 줄일 수 있어 PET 검사의 전처치를 보다 명확하게 확인할 수 있을 것이다. 또한, 혈당 측정 시에 혈액 채취 부위를 모세혈관 또는 정맥혈관 중에서 항상 동일한 부위에서 측정하는 등의 표준화 과정이 필요할 것이다.

  • PDF

컴팩트형 VAV 공조기의 성능평가와 경제성 분석에 관한 연구 (A Study on Economic Analysis and Performance Appraisal of Compact Type Variable Air Volume)

  • 김동철;정광섭;김영일
    • 설비공학논문집
    • /
    • 제27권1호
    • /
    • pp.44-49
    • /
    • 2015
  • Ceiling cooling and heating system that consider load arrangement and space in the ceiling needs to be developed. Therefore, experimental and economic changes were done to verify the performance of compact type VAV. The test results were as follow. 1) Noise test result, measuring approximately 50.4 dB~56.6 dB (before ceiling in landfill), had a better ceiling deadline than the current measure, about a 10 dB noise reduction, so that the office baseline (40~50 dB) noise was judged to be less than test. 2) For the static pressure test result, taking out an outside hydrostatic 25 mmAq, 24.8 mmAq was measured, respectively, at the point. 3) For the life-cycle cost analysis result, the initial investment cost, maintenance replacement costs, and maintenance costs increased 0.2%, but the energy savings ratio was 19.5% while the whole life cycle savings of 40 years LCC was reduced 11.9%.

호흡보호구 사용 노동인구의 3차원 얼굴사이즈 특징 및 한국형 밀착도 검사 패널 개발 (3D Face Dimensions and New Fit Test Panels for the Labor Population Using Respirators in South Korea)

  • 박정근;김세동;조현민
    • 한국산업보건학회지
    • /
    • 제33권2호
    • /
    • pp.247-264
    • /
    • 2023
  • Objectives: The study was to examine the features of three-dimensional(3D) face dimensions and to develop fit test panels for the labor population using respirators in South Korea. Methods: This study was part of the first-year work of a two-year-project conducted at Occupational Safety and Health Research Institute in 2021. After 3D head dimensions data were collected from Size Korea Center managing Sixth Size Korea databases, 3D face dimensions DB for the South Korean labor population was established for 21 items of face dimensions in line with the ISO/TS 16976-2 and KS A ISO 15535. With the South Korean labor population 3D face dimensions DB, in accordance with the ISO/TS 16976-2, the descriptive statistics of 3D face dimensions were calculated and two fit test panels were developed. Results: A total of 2,752 subjects were finally determined and they were 52.9% for male, 41.2% for the highest age-group of 15-29, and residents in the capital area. Mean and standard deviation were obtained for each of the 21 3D face dimensions items for the South Korean labor population. Among the items, male and female face widths were 137.6±5.7 mm, 133.2±5.0 mm, respectively. Male and female face lengths were 116.6±7.0 mm, 107.8±6.8 mm, respectively. Two new South Korean fit test panels, a bivariate test panel and a principal component analysis test panel, were developed using the 3D face dimensions DB as well. Conclusions: Using the 3D face dimensions DB, the mean and standard deviation were featured for each of the 21 items and also the two fit test panels were newly developed in the study. It is suggested that the study outputs should be utilized practically and effectively in selection, use, and management of respirators at work, expecting that respiratory protection can be furthermore improved for respirator users including labor population across the country.