• 제목/요약/키워드: A fire office

검색결과 171건 처리시간 0.027초

The First Performance-based Structural Fire Design for Office Building in Korea

  • Min Jae Park
    • 국제초고층학회논문집
    • /
    • 제12권3호
    • /
    • pp.235-239
    • /
    • 2023
  • In this study, the fire resistance performance of the concrete-filled steel tube (CFT) columns and thin steel-plate composite (TSC) beams installed at a 20-story office building were designed using a performance-based structural fire design. Because of the lack of any specific provisions in the building code and guidelines for structural engineers about the performance-based approach, the only prescriptive approach has been selected for designing fire-resistant structures in Korea. To evaluate the fire resistance performance of the CFT columns and TSC beams, finite element analysis verified by the experimental results studied by several researchers was conducted with ABAQUS. From the fire scenario, the temperature distributions of the CFT columns and TSC beams were found via finite element analysis and the behaviors of the CFT columns and TSC beams were investigated in the structural field based on the temperature distribution.

사무소 건물의 화재하중 분포 (A Survey of Fuel Loads in Office Buildings)

  • 김운형
    • 한국화재소방학회논문지
    • /
    • 제11권1호
    • /
    • pp.37-45
    • /
    • 1997
  • 본 연구에서는 국내 10개 설계 사무소 건물을 대상으로 화재하중 분석방법과 현재의 화재하중 분포 를 제시하였다. 조사범위는 건물 완공 후 거주자가 반입한 이동성 물품(이하 이동하중)으로 제한하였 다. 조사결과는 평면배치, 바닥면적, 사용인원 및 가연물의 특성에 따른 이동하중과의 관련성과 함께 미국의 조사 결과와 비교 분석하였다. 현재 국내 사무소 건물의 이동하중은 95% 신뢰도 기준으로 36.13kg/$m^2$ 에서 52.41kg/$m^2$ 사이에 분포하며 평균 화재하중은 44.27kg/$m^2$ 으로 나타났다. 한 미간의 분포는 미국이 평균 66. 84kg 1m2로 한국의 44.27kg/$m^2$ 에 비해 상당히 높게 나타났다. 본 연구결과는 향후 건불의 화재위험도 분류 및 화재 실험시 가연물량 기준에 적용되며 내화설계의 기준 결정을 위한 기초자료로 활용될 것으로 기대된다.

  • PDF

아트륨 빌딩에서의 사무실과 아트륨간의 화재확산에 관한 연구 (A Study on the Fire Spread between Office Room and Atrium in the Atrium Building)

  • 이수경;김종훈
    • 한국안전학회지
    • /
    • 제15권2호
    • /
    • pp.78-83
    • /
    • 2000
  • 일반적으로 국내에서는 아트륨과 사무실 공간 사이를 내화구조로 하거나 방화셔터를 설치하고 있다. 그러나 선진외국에서는 이미 아트륨과 사무실 공간 사이에 유리벽을 설치할 수 있도록 하고 있다. 단, 유리벽면을 따라 방호용 스프링클러를 설치한다는 조건에서 이다. 본 연구는 이러한 문제점에 대하여 다음과 같이 진행하였다. 각 시나리오에 대하여 화재 시뮬레이션 프로그램인 FASTLite와 BREAK1을 사용하여 화재 전파 및 위험성을 분석하였다. 결과적으로 아트륨과 사무실간에는 아트륨의 규모가 크고 상부가 충분한 연기와 열기의 조정이 가능하고, 창문을 사이에 두고 일정간격으로 스프링클러 헤드를 설치하여 충분히 화재로부터 유리를 보호할 수 있는 경우 방화구획으로 인정 해주어야 할 것이다. 또한 충분한 연기와 열의 제어가 가능한 것이 공학적인 화재분석방법을 통해 인정받은 경우에는 아트륨과 주변 사무실간의 완전개방도 검토되어야 할 것이다.

  • PDF

방범·방재 기능을 갖는 에너지 절약형 조명기기 구현 (The implement of energy saving illuminator with a function of crime and fire prevention)

  • 한영오
    • 한국전자통신학회논문지
    • /
    • 제5권3호
    • /
    • pp.339-343
    • /
    • 2010
  • 본 연구에서는 방범방재 기능을 갖는 에너지 절약형 조명기기를 개발하였다. 개발된 조명기기와 관리실을 지그비 무선통신으로 연결하여 조명기기에서 획득된 정보를 전송할 수 있어 편리하게 모니터링이 가능하다. 본 조명기기를 교실 또는 사무실 내부에 여러 개의 일반 형광등과 병행하여 1개만 설치하면 학교 또는 일반 건물을 위한 저비용 방범방재 및 에너지절약형 무선 네트워크 시스템 구축이 가능하다.

화재감지기의 경년도에 상관한 감응특성 실험.연구

  • 이복영;유인호
    • 방재기술
    • /
    • 통권16호
    • /
    • pp.13-19
    • /
    • 1994
  • An Experimental study on the relation between responsiveness and elapse of years This experiment study is to appraise a fire detector's durability & reliability. Fire detector is located in office, temp range 10-27 고 65 15%, installed in the ceiling with power on. This is the experiment report of elapsed 5 years.

  • PDF

공공건축물의 신재생에너지 적용과 에너지 사용량 분석 (Analysis of New & Renewable Energy Application and Energy Consumption in Public Buildings)

  • 이용호;서상현;김형진;조영흠;황정하
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.153-161
    • /
    • 2012
  • This study conducted a survey and field investigation on the application of the Public Obligation System for new & renewable energy in public buildings, as well as energy consumption of each building according to their uses. The findings are as follows: (1) Since the introduction of the Public Obligation System (until June 30, 2011), there was average 1.4 new & renewable energy facilities established at 1,433 places. Preference for solar energy facilities was the highest at 57.8%. (2) The revised act sets the obligatory supply percentage of new & renewable energy for each public building: it is 9.0% for a tax office, 4.2% for a dong office, 8.2% for a public health center, and 12.6% for a fire station. All the public buildings except for fire stations failed to meet 10% expected energy consumption, a revised standard. (3) Energy consumption of each public building was 120.6TOE for a tax office, 124.3TOE for a dong office, 166.4TOE for a public health center, and 174.6TOE for a fire station. The energy consumption was comprised of 80% electric power, 18% urban gas, and 1% oil. (4) Electric power consumption per person in the room was high at a dong office, and fuel consumption per person in the room was high at a public health center. In addition, electric power consumption per unit space was high at a public health center, and fuel consumption per unit space was high at a fire station. (5) In all the four public buildings, power load had the highest basic unit percentage at average 55%, being followed by heating load (21.2%), cooling load (15%), and water heating load (7%). A tax office and fire station had 2% load due to cooking facilities.

성능위주설계를 위한 가연물의 열발생률 및 화재성장률 측정 -주거 및 사무공간 가연물을 중심으로 (Measurements of the Heat Release Rate and Fire Growth Rate of Combustibles for the Performance-Based Design - Focusing on the Combustibles in Residential and Office Spaces)

  • 남동군;황철홍
    • 한국화재소방학회논문지
    • /
    • 제31권2호
    • /
    • pp.29-36
    • /
    • 2017
  • 가연물의 열발생률에 근거한 설계화원은 성능위주설계의 화재안전성 평가에 매우 중요한 영향을 줄 수 있다. 그러나 현재 성능위주설계에서는 국내 가연물의 화재정보의 부족으로 인하여 제한된 외국 문헌정보가 추가 검증이 없이 적용되고 있다. 본 연구의 목적은 성능위주설계의 신뢰성을 확보하기 위하여 다양한 주거 및 사무공간 가연물을 대상으로 열발생률 및 화재성장률에 관한 정보를 제공하는 것이다. 이를 위해 총 14가지의 단일 및 다수 가연물에 대한 화재실험이 수행되었다. 본 연구에서 고려된 가연물의 최대 열발생률은 36 kW~1,092 kW의 범위를 갖는 것으로 측정되었다. 화재성장률은 주거용 가연물이 $0.003kW/s^2{\sim}0.0287kW/s^2$이고, 사무용 가연물이 $0.003kW/s^2{\sim}0.0838kW/s^2$ 범위를 갖는다. 특히 소파는 최대 열발생률 및 화재성장률의 관점에서 가장 높은 화재 위험성을 갖는다. 마지막으로, 다양한 가연물들의 최대 열발생률과 노출 표면적의 상관관계 분석을 통해 공간 내의 최대 열발생률을 산출하는 방법론이 제안된다.