• Title/Summary/Keyword: A B and C scan images

Search Result 31, Processing Time 0.032 seconds

Ultrasonic Characteristics of Degraded Compacted Graphite Iron from 873 to 1,273 K (873~1,273 K에서 열화된 강화흑연강(Compacted Graphite Iron, CGI)의 초음파특성)

  • Lee, Soo-Chul;Nam, Ki-Woo
    • Journal of Power System Engineering
    • /
    • v.17 no.4
    • /
    • pp.72-78
    • /
    • 2013
  • Compacted graphite iron 340 was carried out the heat treatment from 873 to 1,273 K. Compacted graphite iron 340 was evaluated relationship between the sound velocity, the attenuation coefficient and the tensile strength. The obtained results are as following. The signal strength of C scan images were weak according to increasing of heat treatment temperature and time. The amplitude of A scan and B scan was also low. This can be cause that the graphite was grown into the type of vermicular, and the many of grain boundary with ultrasound scattering were increase. The sound velocity was depend upon the heat treatment temperature and time, the attenuation coefficient had nothing to do with the temperature and time. The higher the heat treatment temperature, the tensile strength and the sound velocity were decreased. However, the tensile strength was proportional to the sound velocity. The higher tensile strength, the faster the sound velocity.

High-resolution Spiral-scan Imaging at 3 Tesla MRI (3.0 Tesla 자기공명영상시스템에서 고 해상도 나선주사영상)

  • Kim, P.K.;Lim, J.W.;Kang, S.W.;Cho, S.H.;Jeon, S.Y.;Lim, H.J.;Park, H.C.;Oh, S.J.;Lee, H.K.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.108-116
    • /
    • 2006
  • Purpose : High-resolution spiral-scan imaging is performed at 3 Tesla MRI system. Since the gradient waveforms for the spiral-scan imaging have lower slopes than those for the Echo Planar Imaging (EPI), they can be implemented with the gradient systems having lower slew rates. The spiral-scan imaging also involves less eddy currents due to the smooth gradient waveforms. The spiral-scan imaging method does not suffer from high specific absorption rate (SAR), which is one of the main obstacles in high field imaging for rf echo-based fast imaging methods such as fast spin echo techniques. Thus, the spiral-scan imaging has a great potential for the high-speed imaging in high magnetic fields. In this paper, we presented various high-resolution images obtained by the spiral-scan methods at 3T MRI system for various applications. Materials and Methods : High-resolution spiral-scan imaging technique is implemented at 3T whole body MRI system. An efficient and fast higher-order shimming technique is developed to reduce the inhomogeneity, and the single-shot and interleaved spiral-scan imaging methods are developed. Spin-echo and gradient-echo based spiral-scan imaging methods are implemented, and image contrast and signal-tonoise ratio are controlled by the echo time, repetition time, and the rf flip angles. Results : Spiral-scan images having various resolutions are obtained at 3T MRI system. Since the absolute magnitude of the inhomogeneity is increasing in higher magnetic fields, higher order shimming to reduce the inhomogeneity becomes more important. A fast shimming technique in which axial, sagittal, and coronal sectional inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the inhomogeneity map is applied. For phantom and invivo head imaging, image matrix size of about $100{\times}100$ is obtained by a single-shot spiral-scan imaging, and a matrix size of $256{\times}256$ is obtained by the interleaved spiral-scan imaging with the number of interleaves of from 6 to 12. Conclusion : High field imaging becomes increasingly important due to the improved signal-to-noise ratio, larger spectral separation, and the higher BOLD-based contrast. The increasing SAR is, however, a limiting factor in high field imaging. Since the spiral-scan imaging has a very low SAR, and lower hardware requirements for the implementation of the technique compared to EPI, it is suitable for a rapid imaging in high fields. In this paper, the spiral-scan imaging with various resolutions from $100{\times}100$ to $256{\times}256$ by controlling the number of interleaves are developed for the high-speed imaging in high magnetic fields.

  • PDF

Higher Order Shimming for Ultra-fast Spiral-Scan Imaging at 3 Tesla MRI System (3 Tesla MRI 시스템에서 초고속 나선주사영상을 위한 고차 shimming)

  • Kim, P.K.;Lim, J.W.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.2
    • /
    • pp.95-102
    • /
    • 2007
  • Purpose: To acquire high-resolution spiral-scan images at higher magnetic field, high homogeneous magnetic field is needed. Field inhomogeneity mapping and in-vivo shimming are important for rapid imaging such as spiral-scan imaging. The rapid scanning sequences are very susceptible to inhomogeneity. In this paper, we proposed a higher-order shimming method to obtain homogeneous magnetic field. Materials and Methods: To reduce measurement time for field inhomogeneity mapping, simultaneous axial/ sagittal, and coronal acquisitions are done using multi-slice based Fast Spin echo sequence. Acquired field inhomogeneity map is analyzed using the spherical harmonic functions, and shim currents are obtained by the multiplication of the pseudo-inverse of the field pattern with the inhomogeneity map. Results: Since the field inhomogeneity is increasing in proportion to the magnetic field, higher order shimming to reduce the inhomogeneity becomes more important in high field imaging. The shimming technique in which axial, sagittal, and coronal section inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the imhomogenity map is applied. The proposed technique is applicable to a localized shimming as well. High resolution spiral-scan imaging was successfully obtained with the proposed higher order shimming. Conclusion: Proposed pulse sequence for rapid measurement of inhomogeneity map and higher order shimming based on the inhomogeneity map work very well at 3 Tesla MRI system. With the proposed higher order shimming and localized higher order shimming techniques, high resolution spiral-scan images are successfully obtained at 3 T MRI system.

  • PDF

New Performance Evaluation Method of Focused Ultrasonic Transducers By Using Virtual 3D Graphic (가상 3D 그래픽을 이용한 집속형 초음파 탐촉자 성능평가 방법)

  • Lee, Sun-Heum;Choi, Kwan-Sun;Kim, Dong-Sik
    • The KIPS Transactions:PartB
    • /
    • v.14B no.6
    • /
    • pp.407-412
    • /
    • 2007
  • The performance of ultrasonic testing systems for industrial or medical purpose largely depends on the performance of ultrasonic transducers. Generally, the information about an ultrasonic transducer performance characteristics are expressed by the ultrasonic R/F signal back from a reflector and its frequency characteristics in the data sheet provided by manufacturers. In case of focused ultrasonic transducers, the two pieces of information can, however, hardly assure that the focused ultrasonic transducer would produce well-focused C-scan images. Therefore, we propose the measured size of focal spot and the reconstructed shape of effective focal zone in the focused sound field as novel measures for the performance evaluation of the focused ultrasonic transducers. The process of getting the both measures of the transducers is conducted by the implemented software including sound field scanning and virtual 3D reconstruction functions which requires the echo of a point reflector. The proposed method could, otherwise impossible in the existing method, effectively and simply distinguish superior ones among many transducers made in the same specification and be also used to detect the performance degradation due to the aging of the transducers. Eventually, the quality of performance of the ultrasonic testing systems for industrial or medical purpose is secured.

Development of 3D Image Processing Software using EMD for Ultrasonic NDE (EMD를 이용한 초음파 비파괴 평가용 3차원 영상처리 소프트웨어 개발)

  • Nam, Myung-Woo;Lee, Young-Seock;Yang, Ok-Yul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1569-1573
    • /
    • 2008
  • This paper describes a development of Ultrasonic NDE software to analyze steam generator of nuclear power plant. The developed software includes classical analysis method such as A, B, C and D-scan images. And it can analyze the detected internal cracks using 3D image processing method. To do such, we obtain raw data from specimens of real pipeline of power plants, and get the envelope signal using Empirical Mode Decomposition from obtained ultrasonic 1-dimensional data. The reconstructed 3D crack images offer useful information about the location, shape and size of cracks, even if there is no special 2D image analysis technique. The developed analysis software is applied to specimens containing various cracks with known dimensions. The results of application showed that the developed software provided accurate and enhanced 2D images and reconstructed 3D image of cracks.

Principal component analysis in C[11]-PIB imaging (주성분분석을 이용한 C[11]-PIB imaging 영상분석)

  • Kim, Nambeom;Shin, Gwi Soon;Ahn, Sung Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.12-16
    • /
    • 2015
  • Purpose Principal component analysis (PCA) is a method often used in the neuroimagre analysis as a multivariate analysis technique for describing the structure of high dimensional correlation as the structure of lower dimensional space. PCA is a statistical procedure that uses an orthogonal transformation to convert a set of observations of correlated variables into a set of values of linearly independent variables called principal components. In this study, in order to investigate the usefulness of PCA in the brain PET image analysis, we tried to analyze C[11]-PIB PET image as a representative case. Materials and Methods Nineteen subjects were included in this study (normal = 9, AD/MCI = 10). For C[11]-PIB, PET scan were acquired for 20 min starting 40 min after intravenous injection of 9.6 MBq/kg C[11]-PIB. All emission recordings were acquired with the Biograph 6 Hi-Rez (Siemens-CTI, Knoxville, TN) in three-dimensional acquisition mode. Transmission map for attenuation-correction was acquired using the CT emission scans (130 kVp, 240 mA). Standardized uptake values (SUVs) of C[11]-PIB calculated from PET/CT. In normal subjects, 3T MRI T1-weighted images were obtained to create a C[11]-PIB template. Spatial normalization and smoothing were conducted as a pre-processing for PCA using SPM8 and PCA was conducted using Matlab2012b. Results Through the PCA, we obtained linearly uncorrelated independent principal component images. Principal component images obtained through the PCA can simplify the variation of whole C[11]-PIB images into several principal components including the variation of neocortex and white matter and the variation of deep brain structure such as pons. Conclusion PCA is useful to analyze and extract the main pattern of C[11]-PIB image. PCA, as a method of multivariate analysis, might be useful for pattern recognition of neuroimages such as FDG-PET or fMRI as well as C[11]-PIB image.

  • PDF

Study of Absorbed Dose and Effective Dose for Prostate Cancer Image Guided Radiation Therapy using kV Cone Beam Computed Tomography (kV Cone Beam Computed Tomography (CBCT)를 이용한 전립선암 영상유도방사선치료 시 흡수선량 및 유효선량에 관한 고찰)

  • Na, Jong-Eok;Lee, Do-Geun;Kim, Jin-Soo;Baek, Geum-Mun;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.67-74
    • /
    • 2009
  • Purpose: To evaluate the results of absorbed and effective doses using two different modes, standard mode (A-mode) and low-dose mode (B-mode) settings for prostate cancer IGRT from CBCT. Materials and Methods: This experimental study was obtained using Clinac iX integrated with On Board Imager (OBI) System and CBCT. CT images were obtained using a GE Light Speed scanner. Absorbed dose to organs from ICRP recommendations and effective doses to body was performed using A-mode and B-mode CBCT. Measurements were performed using a Anderson rando phantom with TLD-100 (Thermoluminescent dosimeters). TLD-100 were widely used to estimate absorbed dose and effective dose from CBCT with TLD System 4000 HAWSHAW. TLD-100 were calibrated to know sensitivity values using photon beam. The measurements were repeated three times for prostate center. Then, Evaluations of effective dose and absorbed dose were performed among the A-mode and B-mode CBCT. Results: The prostate absorbed dose from A-mode and B mode CBCT were 5.5 cGy 1.1 cGy per scan. Respectively Effective doses to body from A mode and B-mode CBCT were 19.1 mSv, 4.4 mSv per scan. Effective dose from A-mode CBCT were approximately 4 times lower than B-mode CBCT. Conclusion: We have shown that it is possible to reduce the effective dose considerably by low dose mode(B-mode) or lower mAs CBCT settings for prostate cancer IGRT. Therefore, we should try to select B-mode or low condition setting to decrease extra patient dose during the IGRT for prostate cancer as possible.

  • PDF

A Simulation Tool for Ultrasonic Inspection

  • Krishnamurthy, Adarsh;Mohan, K.V.;Karthikeyan, Soumya;Krishnamurthy, C.V.;Balasubramaniam, Krishnan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.3
    • /
    • pp.153-161
    • /
    • 2006
  • A simulation program SIMULTSONIC is under development at CNDE to help determine and/or help optimize ultrasonic probe locations for inspection of complex components. SIMULTSONIC provides a ray-trace based assessment for immersion and contact modes of inspection. The code written in Visual C++ operating in Microsoft Windows environment provides an interactive user interface. In this paper, a description of the various features of SIMULTSONIC is given followed by examples illustrating the capability of SIMULTSONIC to deal with inspection of canonical objects such as pipes. In particular, the use of SIMULTSONIC in the inspection of very thin-walled pipes (with 450 urn wall thickness) is described. Ray trace based assessment was done using SIMULTSONIC to determine the standoff distance and the angle of oblique incidence for an immersion mode focused transducer. A 3-cycle Hanning window pulse was chosen for simulations. Experiments were carried out to validate the simulations. The A-scans and the associated B-Scan images obtained through simulations show good correlation with experimental results, both with the arrival time of the signal as well as with the signal amplitudes.

Keyhole Imaging Combined Phase Contrast MR Angiography Technique (Keyhole Imaging기법을 적용한 위상대조도 자기공명 혈관조영기법)

  • Lee, D.H.;Hong, C.P.;Han, B.S.;Lee, M.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.72-77
    • /
    • 2012
  • Phase Contrast MR Angiography(PC MRA) is excellent MRA technique for measuring the velocity of vessels in the human body. PC MRA need to at least four images for angiogram reconstruction and it caused longer scan time. Therefore, we used keyhole imaging combined PC MRA to reduce the scan time. However, keyhole imaging can lead the erroneous effects as loss of phase information or frequency discontinuous. In this study, we applied the keyhole imaging combined 2D PC MRA for improving the temporal resolution and also measured the velocity to evaluate the accuracy of phase information. We used 0.32T MRI scanner(Magfinder II, Scimedix, Korea). Using the 2D PC MRA pulse sequence, the vascular images for a human brain targeted on the Superior Sagittal Sinus(SSS) were obtained. We applied tukey window function for keyhole images to minimize the ringing artifact and erroneous factors that are induced frequency discontinuous and phase information loss. We also applied zero-padded algorithm to peripheral missing k-space lines to compare keyhole imaging results and the artifact power(AP) value was measured on the complex difference images to validate the image quality. Consider as based on our results, heavy image distortions and artifacts were shown until using at least 50% keyhole factor. Using above the 50% keyhole factors are shown well reconstructed and matched for magnitude images and velocity information measurements. In conclusion, we confirmed the image quality and velocity information of keyhole technique combined 2D PC MRA. Especially, measured velocity information through the keyhole imaging combination was similar to the velocity information of full sampled k-space image despite of frequency discontinuous and phase information loss in the keyhole imaging reconstruction process. Consequently, the keyhole imaging combined 2D PC MRA will give some clinical usefulness and advantages as improving the temporal resolution and measuring the velocity information via selecting the appropriate keyhole factor at low tesla MRI system.

Study on the Evaluation of Renal Function According to Set a Partial Region of Interest in 99mTc-DMSA scan of the Pediatric Patient with a Duplicated Ureter (중복요관을 가진 소아환자의 99mTc-DMSA 검사에서 부분적 관심영역 설정에 따른 신기능 평가에 관한 연구)

  • Nam-Koong, Hyuk;Oh, Shin Hyun;Kim, Jung Yul;Choi, Yoon Jung;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.43-47
    • /
    • 2013
  • Purpose: A duplicated ureter is congenital renal malformations with ureter in two. Patients with duplicated ureter are in force to $^{99m}Tc-DMSA$ scan at surgery before and after. In existing examination, at produce result after $^{99m}Tc-DMSA$ scan, didn't compare to upper pole and lower pole with malformed kidney and compared to only relative uptake ratio. Therefore, this study will examine about utility of set a partial region of interest and to functional recovery of renal cell through change of upper pole uptake ratio of malformed kidney by setting each partial region of interest in upper pole and lower pole of malformed kidney in $^{99m}Tc-DMSA$ examination in surgery before and after. Materials and Methods: Pediatric patients with malformed kidney of incomplete duplicated ureter, 15 patients were enrolled in this study. Scanning were scan 3 to 4 hours after injection of $^{99m}Tc-DMSA$ 1.5 ~ 1.9 MBq/kg. Region of interest were each set in normal kidney, upper pole and lower pole with malformed kidney. Region of interest were set with same condition and method to images of surgery before and after that radio technologist 1 person, resident of nuclear medicine 1 person and doctor of urology together. Therefore, this study were compared to uptake ratio (A: B: C) that normal kidney (A), lower pole of malformed kidney (B) and upper pole of malformed kidney (C) about uptake ratio changes of malformed kidney in follow-up examination of surgery before and after. Results: When compared to 15 patients, uptake ratios were increased 7 persons and decreased 8 persons. Among increased 7 persons, it were periods of follow-up examination that 2 persons were 14 months, 4 persons were 12 months and 1 person was 8 months after surgery. Among decreased 8 persons, it were periods of follow-up examination that 4 persons were 12 months 3 persons were 6 months and 1 persons were 4 months after surgery. Conclusion: Existing study could not see the exact uptake ratio changes of malformed kidney because using only the overall Left-Right kidney uptake ratios. But a setting partial region of interest was able to see exactly what changes in the uptake of each upper pole and lower pole of malformed kidney. Because recovery of renal parenchymal cells is difficult in an evaluation of short period of time, follow-up examination should be made in long period of time. How to set up partial region of interest be thought that it would be useful.

  • PDF