• Title/Summary/Keyword: A/V Appliance

Search Result 35, Processing Time 0.021 seconds

Vacuum Assisted Wound Closure Appliance and Continuous Irrigation on Infected Chronic Wound (감염된 만성창상에서 국소음압세척치료의 이용)

  • Jeong, Jin-Wook;Kim, Jun-Hyung;Jung, Yung-Jin;Park, Mu-Sik;Son, Dae-Gu;Han, Ki-Hwan
    • Archives of Plastic Surgery
    • /
    • v.37 no.3
    • /
    • pp.227-232
    • /
    • 2010
  • Purpose: Continuous irrigation method is an important step in managing wound infection. V.A.C. devices have been used in intractable wounds for reducing discharge, improving local blood flow, and promoting healthy granulation tissue. We expect synergistic effects of reduced infection and more satisfactory, accelerated wound healing when using both methods simultaneously. This study evaluated continuous irrigation combined with V.A.C. appliance for treatment of infected chronic wounds. Methods: We reviewed data from 17 patients with infected intractable chronic wounds. V.A.C. device (Group A) was used in 9 patients, and V.A.C. with antibiotics irrigation (Group B) was used in 8 patients. We placed Mepitel$^{(R)}$ on the surface of wound and placed an irrigation and aspiration tube on each side. A sponge was placed on the Mepitel$^{(R)}$ and covered with film dressing. The wound was irrigated continuously with mixed antibiotics solution at the speed of 200 cc/hr and aspirated through the wall suction at the pressure of -125 mmHg. V.A.C. applied time, wound culture and wound size were compared between the two groups. Results: No complication were seen in two groups. Compared with Group A, in the Group B, V.A.C. applied time was shortened from 32.7 days to 25.6 days and showed efficacy in the reduction rate of wound size. No statistical differences were shown in bacterial reversion. Conclusion: V.A.C. appliance with continuous irrigation is an effective new method of managing infected chronic wounds and useful to reduce treatment duration and decrease wound size. Moreover it could be applied more widely to infected wound.

A Study on Voice User Interface for Domestic Appliance (가전제품의 음성 인터페이스 디자인 적용에 대한 연구)

  • Hong, Ji-Young;Jeon, Myoung-Hoon;Han, Kwang-Hee;Chae, Haeng-Suk
    • Science of Emotion and Sensibility
    • /
    • v.10 no.1
    • /
    • pp.55-68
    • /
    • 2007
  • This paper describes a Voice User Interface(VUI) method and a design guideline tool which supports the studies for domestic appliance. This issue covers specification of user requirement and selection of appropriate VUI to represent speech generation. The criteria for paper is interaction design to enhance user engagement. The studies were carried out to measure prototype of domestic appliance such as a refrigerator, a washing machine, a Gimchi refrigerator, an oven range, a dishwasher and an air conditioner. This paper is presented a study of user preferences and suitability. The results of these findings to voice interface design are discussed and it is suggested that VUI guideline and optimal prototyping can provide a useful application tools in the design process.

  • PDF

Loss Analysis of Pulse Type Inverter Circuit for PLS (PLS용 펄스형 인버터 회로의 손실분석)

  • Jung Yong-Chae;Jung Yun-Chul;Kim Eui-Sung
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.146-148
    • /
    • 2006
  • The aim of the paper is to design the PLS(Plasma Lighting System) driving inverter circuit with optimal efficiency. In general, it is known that the PLS driven by a pulse has a higher light-conversion efficiency. There are the Class-E type resonant inverter and the semi-bridge inverter as a circuit which can make a pulse with low duty ratio. In this paper, we analyze the losses of the above two circuits. To verify the loss analysis, the inverter circuit with 220V 380W input consumption is manufactured and tested. Throughout the experimental results, the high efficiency PLS system has confirmed.

  • PDF

Effects of a Prefabricated Functional Orthodontic Appliance on Children with Class II Division 1 Malocclusion

  • So-Youn An;Eun-Hee Kim;Ho-Uk Lee;Sang-Ho Bak;Hyo-Jin Kang;Youn-Soo Shim
    • Journal of dental hygiene science
    • /
    • v.23 no.2
    • /
    • pp.112-122
    • /
    • 2023
  • Background: This study aimed to evaluate the effect of a prefabricated functional appliance (Myobrace®) on skeletal, dental, and soft tissue components in children with Class II, division 1 malocclusion. Methods: Thirteen patients with Class II, division 1 malocclusion (9 girls and 4 boys; mean age, 8.2±0.9 years at the start and 9.3±1.0 years at the end of the treatment) were treated with Myobrace® for a mean period of 12.9±4.0 months. Patients were instructed to use the appliance daily for 1 hour and overnight while sleeping. A control group of 10 patients with untreated Class II, division 1 malocclusion (3 girls and 7 boys; mean age, 9.0±1.6 years at the start and 10.4±2.1 years at the end of the observation) was included to eliminate possible growth effects. The mean observation period for this group was 17.7±11.2 months. Lateral cephalograms were taken at the start and end of the treatment, and findings from 41 measurements were analyzed using the V-CephTM program. The mean and standard deviation of cephalometric measurements were analyzed using paired and independent sample t-tests. Results: The treatment group showed significant changes in SNB, ANB, maxillary protrusion, ramus height, proclination of upper anterior teeth, interincisal angle, overjet, and upper lip protrusion compared with the control group. However, only decrease in ANB, maxillary protrusion, overjet, upper lip protrusion, and increase in interincisal angle were significantly higher in the treatment group than in the control group. Conclusion: The prefabricated functional appliance induced skeletal, dentoalveolar, and soft tissue changes, resulting in a significant reduction in anteroposterior discrepancy.

Stimulation of Cephalosporin C Production by Acremonium chrysogenum M35 with Fatty Acids

  • Kim Jong-Chae;Kang Seong-Woo;Lim Jung-Soo;Song Yoon-Seok;Kim Seung-Wook
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.7
    • /
    • pp.1120-1124
    • /
    • 2006
  • Supplementation with rice oil and its major components (oleic acid and linoleic acid) was found to have a significant influence on cephalosporin C (CPC) production and cell growth by A. chrysogenum M35 in shake flask cultures. Five percent (v/v) rice oil had the most robust effect and 5% (v/v) oleic acid was the second most efficient on cell growth, whereas 3% (v/v) linoleic acid was found to be optimal for CPC production. Rice oil, oleic acid, and linoleic acid also significantly improved the rates of glucose consumption. When glucose was almost consumed, CPC production was initiated and, on the addition of rice oil, lipase activity increased steadily to 1.56 U/ml for 4 days. These results suggest that rice oil and fatty acids are used as carbon source to produce CPC by A. chrysogenum M35. Moreover, a mixture, composed of 40% (v/v) oleic acid and 60% (v/v) linoleic acid, had the strongest stimulatory effect on CPC production, due to a synergistic effect of the two fatty acids. Consequently, the maximum CPC titer (7.44 g/l) was improved about 4.5-fold.

A Study on Flow Characteristics of ERF Between Two Parallel-Plate by Using PlV (평형평판 간극사이에서 PIV를 이용한 ER유체의 유동특성에 관한연구)

  • Jung Wan-Bo;Park Young-Seuk
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.1
    • /
    • pp.56-62
    • /
    • 2006
  • An experimental investigation was performed to study the characteristics of ER(Electro-Rheological) fluid flow in a horizontal rectangular tube with or without D.C voltage. To determine some characteristics of the ER flow, 2D PIV(Particle Image Velocimetry) technique is employed for velocity measurement. This research found the mean velocity distribution with 0kV/mm, 1.0kV/mm and 1.5kV/mm for Re = 0, 0.62, 1.29 and 2.26. When the strength of the electric field increased, the cluster of ERF are clearly strong along the test tube and the flow rate decreased. In this study, the rheology of ER fluid stagnating or flowing through a dispersion meter will be investigated by PIV method. And then the ER effect, which appears at the ER valves and their appliance will be visualized.

Effectiveness of the Invisalign Mandibular Advancement Appliance in Children with Class II Division 1 Malocclusion

  • So-Youn An;Hyeon-Jin Kim;Ho-Uk Lee;Sang-Ho Bak;Hyo-Jin Kang;Youn-Soo Shim
    • Journal of dental hygiene science
    • /
    • v.23 no.4
    • /
    • pp.245-254
    • /
    • 2023
  • Background: This study aimed to determine the skeletal and dental effects in pediatric and adolescent Korean patients with Class II Division 1 malocclusion treated using the Invisalign Mandibular Advancement (MA®) appliance. Methods: The study included patients aged 6 to 18 years who received orthodontic treatment with the MA® appliance for Class II Division 1 malocclusion at the Department of Pediatric Dentistry, Wonkwnag University Daejeon Dental Hospital, between July 1, 2018, and December 31, 2021. The treatment group consisted of 20 patients, 10 boys and 10 girls. The control participants were also 10 boys and 10 girls. Lateral cephalometric radiographs were taken before and after treatment, and 41 measurements of skeletal and dental changes were measured and analyzed using the V-CephTM 8.0 (Osstem Implant). All analyses were performed using SPSS software (IBM SPSS for Windows, ver 26.0; IBM Corp.), and statistical significance was tested using paired and independent samples t-tests for within-group and between-group comparisons, respectively. Results: The patients in the treatment group showed significant decreases in ANB (A point, Nasion, B point), maxillary protrusion, maxillary anterior incisor labial inclination, and maxillary protrusion after treatment. However, when compared with the growth changes observed in the control group, only ANB and maxillary protrusion decreased, with no significant differences in SNA, SNB, and mandibular length. Conclusion: Collectively, the results of this study confirm that the use of MA® appliance in pediatric and adolescent Korean patients with Class II Division 1 malocclusion results in a reduction of anteroposterior skeletal and dental disharmony.

Electric power system effect investigation of large size digital signal accident thought in digital age (디지털시대의 대형사고의 전기적 영향 고찰)

  • Kang, Tae-Keun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.575-580
    • /
    • 2004
  • The latest equipment automatic Intelligence of digital base done large size equipment appear in succession. That run by voltage electric current(mA, mV, ${\mu}A,\;{\mu}V$) that outline is microscopic of action of accuracy large size equipment of this digital base is bulk. Have received influence that is great in river electric field by installment that use computer. Most of domestic working voltage from service entrance extra-high voltage and working voltage of commercial frequency 60Hz working voltage 220V that use our country outside 1 country in interior of 22.900V for semiconductor use computer use digital installment of appliance as well as various smalls of digital base, middle, large size that safety is these fine voltage electric current that is not enough direct admonition hundred vast damage give can. Also, already act in surge circle and impulse transient phenomena such as several thousands, myriads, strong bit error more than billions time to digital fine electronic circuit by mistake use of using electric facility system of system electric power.

  • PDF

Measurement of Turbulent Intensity Distributions of a Cylinder Wake

  • Doh, Deog Hee;Cho, Gyeong Rae;Moon, Kyeong Rok;Cho, Yong Beom
    • Journal of the Korean Society of Visualization
    • /
    • v.11 no.1
    • /
    • pp.41-47
    • /
    • 2013
  • Turbulence properties of a cylinder wake (d=10 mm) have been investigated with a new volume PTV algorithm. The measurement system consists of two-high-cameras(1 $k{\times}1$ k), a Nd-Yag laser and a host computer. A fitness function representing three-dimensional coherency has been adopted to sort out spurious vectors. A hybrid fitness function representing the relations between the fitness and the three-dimensional shortest distances constructed by the two collinears of the two cameras has been also adopted. The constructed algorithm has been employed for the measurements of the cylinder wakes. The Reynolds numbers tested in this paper are 360, 540, 720, 900, 1080 and 1260. More than 10,000 instantaneous 3D vectors have been obtained by the constructed system. The volumetric distributions of the turbulence intensities (for u', v', w') indicate that clearly different patterns for all Reynolds numbers and imply that a regular pattern (like a similarity rule) for the turbulent properties exists.

An Experimental Study on the High Performance Optimal Discharge System of a Rotary Compressor for an Air Conditioner using alternative Refrigerant R410a (대체냉매 공기조화기용 로터리 압축기의 성능향상을 위한 최적 토출계에 관한 실험적 연구)

  • Youn, Young;Chung, Jin-Taek;Min, Man-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.2
    • /
    • pp.96-105
    • /
    • 2001
  • R410a which is one of HFC refrigerants is being considered to be a promising replacement for R22 widely used in domestic air conditioners. The rolling piston type rotary compressors for R410a have lower energy efficiency than those for R22 because of the high pressure difference between a suction chamber and a discharge chamber in the compression mechanism. in addition, the re-expansion gas loss of the rotary compressor for R410a which occurs a ta clearance volume in a discharge port becomes larger than that for R22 due to high density of R410a refrigerant. Therefore, Pressure-Volume analyses for various design parameters of a discharge system were carried out to improve efficiency of a R410a rotary compressor. The results such as performance dta, over-compression loss, and re-expansion loss were acquired by P-V analyses and analyzed quantitatively. As a conclusion, the optimal specifications of several design parameters of a discharge system were obtained by analyzing P-V diagrams.

  • PDF