• 제목/요약/키워드: A/S ratio

검색결과 16,314건 처리시간 0.053초

수평 비원형이중관 사이의 환상공간에서의 자연대류 (Natural Convection in the Annulus between Horizontal Non-Circular Cylinders)

  • 배대석;권순석
    • 설비공학논문집
    • /
    • 제1권4호
    • /
    • pp.305-312
    • /
    • 1989
  • Laminal natural convection heat transfer in the annulus between isothermal horizontal non-circular cylinders is studied by solving the Navier-Stokes and energy equation using an elliptic numerical procedure. Results are obtained to determine the effects of the diameter ratio($D_o/D_i$) and Rayleigh number on heat transfer. The diameter ratio is varied from 1.5 to 13.0 at Pr=0.7, H/L=1.5 and $10^3{\leqslant}Ra_L{\leqslant}4{\times}10^4$. It is found that the diameter ratio causes a more significant on the local heat transfer coefficient of lower semi-circular cylinder and plate than upper semi-circular cylinder. The mean Nusselt number increases as the diameter ratio and Rayleigh number increase, and is higher than that of the circular annulus with a same wetted perimeter.

  • PDF

DAF(Dissolved Air Flotation)를 이용한 제지폐수의 COD, SS 및 탁도 제거 (COD, SS and Turbidity Removal of Paper Wastewater Using DAE(Dissolved Air Flotation))

  • 김동석;박영식
    • 한국환경보건학회지
    • /
    • 제31권4호
    • /
    • pp.246-253
    • /
    • 2005
  • The supernatant treatment of recovery process of raw materials of paper plant was studied using DAF (Dissolved Air Flotation) system. We investigated the removal efficiency (COD, SS and turbidity) of the DAF process. The effects of parameters such as A/S ratio, pressure, flotation conditions, coagulant concentration, mixing conditions, size and ratio of packing and nozzle type were examined. The results showed that the optimum A/S ratio and pressure were 0.058 and 4.5-5 atm, respectively. Injection times of pressurized water around 30 s and flotation times around 10 min appeared to be optimal for the DAF operation. Anion polymer addition improved the removal of COD, SS and turbidity. The smaller size and the more packing ratio were enhanced the removal efficiencies. The order of performance of nozzle was full cone > flat > assemble type.

PERFORMANCE OF MULTILAYER CERAMIC ACTUATOR BY CONSIDERING THE SHAPE EFFECT

  • 위상봉
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.594-597
    • /
    • 2003
  • In the present study, the piezoelectricity and polarization of multilayer ceramic actuator, being designed to stack PMN-PZ-PT ceramic layers and Ag-Pd electrode layers alternatively, were investigated under a consideration of geometric factor, the volume ratio of the ceramic to the electrode layers. The actuators were fabricated by tape casting of 0.2Pb(Mg1/3Nb2/3)O3-0.38PbZrO3-0.42PbTiO3 followed by lamination and burnout & co-firing processes. The actuators of 10 10 0.62 nm3 in size were formed in a way that 60 200 m thick ceramics were stacked alternatively with 5 m thick electrode layer. Increases in polarization and electric field-induced displacement with thickness of the ceramic layer were attributed to change of 90o/180o domain ratio, which was affected by interlayer internal stress. The piezoelectricity and actuation behaviors were found to depend upon the volume ratio (or thickness ratio) of ceramic to electrode layers.

  • PDF

Redox Property of Vanadium Oxide and Its Behavior in Cataltic Oxidation

  • 김영호;이호인
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권12호
    • /
    • pp.1457-1463
    • /
    • 1999
  • Structure and their redox property of the vanadium oxides prepared by decomposing NH₄VO₃ at various temperatures were studied by XRD, SEM, XPS, and temperature programmed reduction/temperature programmed oxidation (TPR/TPO) experiment. All TPR profiles have two sharp peaks in the temperature range 650-750℃, and the area ratio of the two sharp peaks changed from sample to sample. There were three redox steps in TPR/TPO profiles. The oxidation proceeded in the reverse order of the reduction process, and both the reactions proceeded via quite a stable intermediates. The changes of the morphological factor $(I_{(101)}/I_{(010)})$, the ratio of $O_{1S}$ peak area (O$_{1S}$( α)/O$_{1S}$( β)) in the XPS results, and the ratio of hydrogen consumption in TPR profiles with various vanadium oxides showed the distinct relationship between the structural property and their redox property of vanadium oxides. The change of the specific yield of phthalic anhydride with various vanadium oxides showed a very similar trend to those of the peak area ratio in TPR profiles, which meant that the first reduction step related to the partial oxidation of o-xylene on the vanadium oxide catalyst.

Measurement of the Film Cooling Effectiveness on a Flat Plate using Pressure Sensitive Paint

  • Park, S.D.;Lee, K.S.;Kwak, J.S.;Cha, B.J.
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.53-58
    • /
    • 2008
  • Film cooling effectiveness on a flat plate was measured with pressure sensitive paint. The pressure sensitive paint(PSP) changes the intensity of its emissive light with pressure and the characteristic was used in film cooling effectiveness measurement. The film coolants were air and nitrogen, and by comparing the intensity of PSP coated surface with each coolant, the film cooling effectiveness was calculated. Three blowing ratio of 0.5, 1, and 2 were tested with two mainstream turbulence intensities. Results clearly showed the effect of blowing ratio and mainstream turbulence intensity. As the blowing ratio increases, the film cooling effectiveness was decreased near the film cooling holes. However, the film cooling effectiveness far downstream from the injection hole was higher for higher blowing ratio. As the mainstream turbulence intensity increased, the film cooling effectiveness was decreased at far downstream from the injection hole.

  • PDF

Effect of coarse aggregates and sand contents on workability and static stability of self-compacting concrete

  • Mohamed, Sahraoui;Taye, Bouziani
    • Advances in concrete construction
    • /
    • 제7권2호
    • /
    • pp.97-105
    • /
    • 2019
  • In this paper, the workability and static stability were evaluated using a proposed test method. Workability and static stability represent a key property of self-compacting concrete (SCC) in fresh state. A number of standardized test methods were developed to assess these properties. However, no accelerated test method reliably predicts both workability and static stability of SCC. In the present work, a modified K-slump test method was developed to evaluate workability and static stability of SCC. In order to take implicit mixture variations of SCC constituents that can affect fresh SCC properties, a central composite design was adopted to highlight the effect of gravel to sand ratio (G/S), gravel 3/8 to gravel 8/15 ratio (G1/G2), water to cement ratio (W/C), marble powder to cement ratio (MP/C) and superplasticizer content (SP) on workability measured with slump and flow time (T50) tests and static stability measured with sieve stability test (Pi), segregation test index (SSI), Penetration test (Pd) and the proposed K-slump test (Km). The obtained results show that G/S ratio close to 1 and G1/G2 ratio close to 60% can be considered as optimal values to achieve a good workability while ensuring a sufficient static stability of SCC. Acceptable relationships were obtained between Slump flow, Pi, Pd and Km. Results show that the proposed K-slump test allow to assess both workability and static stability of fresh SCC mixtures.

고체 분말이 부상하는 2상 난류 수직관 유동에 대한 Lumley의 저항감소 모델의 적용 (II) - 열전달 기구 - (Application of Lumley's Drag Reduction Model to Two-Phase Gas-Particl Flow in a Pipe(II) - Mechanism of Heat Transfer-)

  • 한기수;정명균;성형진
    • 대한기계학회논문집
    • /
    • 제14권1호
    • /
    • pp.214-224
    • /
    • 1990
  • 본 연구에서는 현 저자의 이전의 연구를 확장하여 균일한 열유속을 갖는 2상 기체-고체입자 위 방정식에서 축 방향의 열전달은 반경 방향의 열전달보다 작아 무시 하였으며, 복사 열전달은 기체와 입자 사이의 온도 차이가 적어 무시하였다. 방정식 중 $F_{px}$$F_{pr}$ 은 2상 사이의 상호작용에 의한 단위부피당 축방향과 반경방향 의 저항력이며, 수직관의 열전달 특성을 부하도와 상대 입자 크기 $d_{p}$/D를 변화시 켜 가면서 조사하는 것이다.다.

맥솔(脈率) 측정방법(測定方法)의 신뢰도(信賴度) 분석(分析) (The Analysis on the Reliability of Measuring Pulse-Respiration Ratio)

  • 김동훈;양동훈;허웅;박영재;박영배
    • 대한한의진단학회지
    • /
    • 제9권2호
    • /
    • pp.123-144
    • /
    • 2005
  • Objectives: Pulse-Respiration Ratio has been used for estimating subject's Han-Yeol [寒熱] status since it mentioned in suwen [素問]. In practicing Pulse-Respiration Ratio over 5 means the status of Yeol [熱], Pulse-Respiration Ratio below 3 means the status of Han [寒]. We performed this study to examine the Optimum Standard for Measuring Pulse-Respiration Ratio on the Basis of Repeatability and Reproducibility. Methods: After subject's 5 minutes rest we measured subject's ECG, respiration pattern, EEG, EMG simultaneously. In this research examiner's number is two, subject's number is four, and the number of repeat is two. We calculated Pulse-Respiration Ratio through dividing Respiration cycle average by Pulse cycle average according to each standard including time section, $EEG(relative-{\alpha}$ density, $relative-{\beta}$ density, ${\alpha}/{\beta}$ and EMG. We analyzed these data through Gage R&R study using MINITAB 13.20 program and considered the results of below 30 %R&R and over 4 Number of Distinct Categories to have a significance. Results: 1. In the applying of time standard, Pulse-Respiration Ratio from section 3, 4, 6, 8 had a significant meaning in the aspect of Repeatability and Reproducibility. 2. In the applying of $EEG({\alpha}$ I , ${\beta}$ I , ${\alpha}/{\beta})$, EMG(E I) standard, there was no significant results. 3. In the applying of time standard(section 5, 6, 7), $EEG({\alpha}$ I , ${\beta}$ I , ${\alpha}/{\beta})$ and EMG(E I) standard simultaneously, Pulse-Respiration Ratio from ${\alpha}/{\beta}$ in section 6, ${\beta}$ I in section 8 had a significant meaning in the aspect of Repeatability and Reproducibility. Conclusions: We can suggest the Optimum Standard for Measuring Pulse-Respiration Ratio on the basis of Repeatability and Reproducibility as followings; 1. Pulse-Respiration Ratio Measuring time should be at least 15 minutes. 2. Applying of time(section 6, 8) and $EEG({\beta}$ I, ${\alpha}/{\beta})$ standard simultaneously is recommended considering reliability and validity but more study is needed. 3. EMG(E I) may be helpful to detect the segment of physical rest and exclude artifacts but more study is needed.

  • PDF

한국잔디(Zoysia japonica Steud.) 종자의 발아촉진에 관한 연구 (Studies on the Germination Promotion of the Zoysia japonica seeds.)

  • 전우방
    • 아시안잔디학회지
    • /
    • 제1권1호
    • /
    • pp.30-36
    • /
    • 1987
  • In order to promote the germination of Korean lawn grass(Zoysia japonica Steud.) seeds a gravimetric seed selection with a mixed chemical solution and the germination promotion with KOH treatment were studied and following results were obtained. 1. When immersed into methanol(S.G., 0.7) 14 percent of immature seeds were precipitated. 2. With water (S.G., 1.0) 36.5 percent of mature seeds were submerged. 3. On a mixture of carbon tetrachloride (S.G., 1.6) and ethylether (S.G., 0.7) in a ratio of 4:6 the seed selection was most effective. 4. When treated with KOH solution the germination rate was 71.01 percent in contrast to 6.0 percent of germination without the treatment. 5. As for concentration of KQH solution, 15 percent depressed the germination (46.7 %) whereas above 20 % the germination rate was gradually increased (79.32 %) up to 40 percent of concentration where the concentration started to depress germination ratio (77.32 %). 6. Finally, in connection with the duration of KOH treatment, a time lapse of up to 20 minutes depressed the germinating ratio(70.02 %) and 30 minutes to 45 minutes increased this ratio to 94.52 percent. 60 minutes of treatment depressed the germination to 75.62 percent.

  • PDF

Optimum Radial Build of a Low Aspect Ratio Tokamak Reactor

  • Hong, B.G.;Hwang, Y.S.;Kang, J.S.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.397-397
    • /
    • 2011
  • In a low aspect ratio (LAR) tokamak reactor with a superconducting toroidal field (TF) coil, the radial build of TF coil and the shield play a key role in determining the size of a reactor. For self-consistent determination of the reactor components and physics parameters, a system analysis code is coupled with one-dimensional radiation transport code. Conceptual design study of a compact superconducting LAR tokamak reactor with aspect ratio less than 2.5 was conducted and the optimum radial build was identified. It is shown that the use of an improved shielding material and high temperature superconducting magnets with high critical current density opens up the possibility of a fusion power plant with compact size and small re-circulating power simultaneously at low aspect ratio, and that by using an inboard neutron reflector instead of breeding blanket, tritium self-sufficiency is possible with outboard blanket only and thus compact sized reactor is viable.

  • PDF