• Title/Summary/Keyword: 90 degree

Search Result 1,593, Processing Time 0.032 seconds

Experimental Study of Frozen Barrier Using Artificial Ground Freezing System (인공지반동결 시스템을 이용한 동결차수벽의 실험적 연구)

  • Shin, Eun-Chul;Kang, Hee-Myeong;Park, Jeong-Jun;Kim, Sung-Hwan
    • Journal of the Korean Geosynthetics Society
    • /
    • v.8 no.3
    • /
    • pp.35-44
    • /
    • 2009
  • The purpose of this study was to prevent spreading of contaminants from movement of underground water by creating a barrier using artificial freezing method on a soil contaminated by oils and various NAPLs. Specimens with 80% and 90% degrees of saturation were prepared to form freezing barrier using artificial freezing method. With increasing freezing time of freezing barrier, barrier was formed faster in the specimen with 90% degree of saturation by about an hour compared to the specimen with 80% degree of saturation. In addition, thinnest thickness of frozen barrier in both specimens was 50mm after 12 hours of freezing time, showing expansion of freezing area with time. The results of this study can be applied to barrier in waste reclamation sites and contaminated regions or to flow control of contaminants.

  • PDF

Comparison of Exposure dose according to the C-arm Angle Change (C-arm 각도 변화에 따른 피폭선량 비교)

  • Shin, Seong-Gyu
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.9
    • /
    • pp.453-458
    • /
    • 2011
  • This study aimed to figure out the change of exposure dose to the radiologist according to the C-arm angle change. For the exam it was fixed with 101 kvp and 4.9mA for the exposure time with 3 seconds and 5 seconds respectively. C-arm Tube was located both under and over, then the average was taken after performing for 5 times with the change of angle from -30 degree to 0, 30, 60 and 90 degree. The detector measured in 160cm high from the position of the radiologist who operates the C-arm. The measurement was shown its highest result at -30 degree followed by 0, 30, 60, 90 from the highest order. Over tube method is higher than under tube method. Therefore, to reduce the exposure dose of the radiologist, it is required for using under tube method instead of over tube method. When the angle change is made, it is recommended to use the angle that tube is growing further apart from the radiologist. And it is also necessary to shorten exposed time as much as possible to create the same quality image and also to reduce the exposure dose.

The Effect on grasp and pinch strength according to degree of elbow flexion in normal adult (성인의 주관절 굴곡 각도가 파악력과 핀치력에 미치는 영향)

  • Lee, Cu-Rie;Kim, Keun-Jo;Kim, Bonn-Won
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.14 no.2
    • /
    • pp.25-33
    • /
    • 2008
  • Purpose : This study was investigated the effect on grasp and pinch strength according to degree of flexion in elbow joint. Methods : Thirty male and thirty female students, aged 20 to 31 years were tested for using opened positioning with their shoulder abduction at $55^{\circ}$ and shoulder horizontal adduction at $30^{\circ}$ in four elbow flexion($0^{\circ}$, $45^{\circ}$, $90^{\circ}$, $135^{\circ}$). An electronic dynamometer(E-LINK V900s Evaluation System)and goniometer were used to measure grasp and pinch strength. Results : The average grasp strength of the dominant hand was strongest at elbow $45^{\circ}$ however, weakest at elbow $135^{\circ}$ flexion in both of male and female. The average pinch strength of the dominant hand was strongest at elbow $135^{\circ}$ flexion in both of male and female. The average pinch strength of dominant hand was weakest at elbow $45^{\circ}$ flexion in both of male and female. According to degree of elbow flexion in both of male and female, grasp and pinch strength was no significant statistically. In analyzing correlations, the grasp strength of male showed the most significant difference at elbow $45^{\circ}$ & $90^{\circ}$ flexion, and the pinch strength was most significant difference at elbow $0^{\circ}$ & $45^{\circ}$ flexion. Conclusion : In analyzing correlations, the grasp strength of female showed the most significant difference at elbow $90^{\circ}$ & $135^{\circ}$ flexion, and the pinch strength was most significant difference at elbow $45^{\circ}$ & $90^{\circ}$ flexion.

  • PDF

Comparative Analysis of the Gastroptosis and Degree of Obesity (위하수와 비만도의 비교 분석)

  • Park, Myung-Je
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.261-265
    • /
    • 2006
  • This study designed for identifying whether female and the thin and the light have gastroptosis more, as known from long time ago, or not, through analyzing correlation of gastroptosis and degree of obesity. People who are subject of health examination for adult disease, who visited a health examination hospital at downtown in pusan, and then are received health examination, who are conducted UGI series between January and June in 2006 are eligible for the study. During the same period, randomised 584 people without gastroptosis were enrolled, grouped with sex and age, and each group involved 73 people. The classification of figure of body was based on standard weight table, and Broca's fomular was used for calculation of degree of obesity. and then We get the result, as following, 1. The women(514/584) have gastroptosis more than men(70/584). 2. Gastroptosis is most common in 90-109%, 54.3% of male, 56.4% of female. The man 90% under, the woman appeared with 110-119%. 3. In the distribution of degree of obesity between ages, gastroptosis is more common at the fifties, and there is no sexual difference.

  • PDF

Studies on Evaluation for Long-term Loading of Composite Wood-joint and Characteristics of Joint Strength (I) - The strength properties of mechanical joints of Pinus densiflora with drift pin and bolt - (목재 접합부의 강도특성 및 장기 내력 평가 (I) - 소나무재의 Bo1t 및 Drift pin 접합부 능력(耐力) 성능 평가 -)

  • Hong, Soon-Il;Hwang, Won-Jung;Kim, Eun-Sam;Jin, Kwang-Sung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.1-8
    • /
    • 2001
  • This study was carried out to investigate the strength and stiffness of drift pinned and bolted joints with steel-plates by the tension-type lateral strength tests. Specimens were solid wood of Pinus densiflora. Bolt and drift pin were jointed with inserted steel plates. Tests were conducted with combinations of two loading directions (parallel to the grain : 0 degree, perpendicular to the grain : 90 degree) and three diameters of fasteners (d = 6 mm, 10 mm, 12 mm). The results obtained were as follow: 1. In the test of the parallel to the grain, maximum loads were increased with increasing of the diameter of bolt and drift pin in the same end distance. In the test of perpendicular to the grain with diameter 10 mm and 12 mm, specimens mostly were failed with horizontal splits in woods reaching the yield load of drift pinned and bolted joints. 2. The ratio of maximum load to the yield load determined by the so-called "5% offset method", was great in bolted joints in the parallel to the grain This trend become more remarkable as the slenderness ratio was increased. 3. The calculated yield strength was agreed well with the experimental results of drift pinned joint(0 degree).

  • PDF

FEA estimates of margin design in all ceramic crowns (완전 도재관을 위한 지대치 형성시 변연 형태에 따른 응력 분포의 유한요소법적 비교)

  • Han, Sang-Hyun;Cho, Jung-Hyeon;Lee, En-Jung;Jeong, Suk-In;Oh, Nam-Sik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.1-11
    • /
    • 2008
  • Statement of problem: Over the past decade, increased demand for esthetically pleasing restorations has led to the development of all-ceramic systems. Recent reports suggest that the all-ceramic crowns have excellent physical properties, wear resistance, and color stability. In addition, numerous ceramics have excellent biocompatibility, a natural appearance, and improved physical bonding with resin composite luting agents. However, the brittle nature of ceramics has been a major factor in their restriction for universal usage. Functional occlusal loading can generate stress in the luting agent, and the stress distribution may be affected by the marginal geometry at the finish line. Tooth preparation for fixed prosthodontics requires a decision regarding the marginal configuration. The design dictates the shape and bulk of the all ceramic crowns and influences the fit at the margin. Purpose: The purpose of this study was to evaluate the stress distribution within marginal configurations of all- ceramic crowns (90-degree shoulder, 110-degree shoulder, 135-degree shoulder). Material and methods: The force is applied from a direction of 45 degrees to the vertical tooth axis. Three-dimensional finite element analysis was selected to determine stress levels and distributions. Results and conclusion: The result of stress level for the shoulder marginal configuration was more effective on stress distribution at 135-degree shoulder margin. But the stresses concentrated around at 135-degree shoulder margin. The stress decreased apically at the surface between cements and alumina core, and increased apically at the surface between alumina core and veneering porcelain.

The Effect of T90 Temperature on Exhaust Emissions in Low-temperature Diesel Combustion (저온 디젤 연소에서 T90 온도가 배기가스에 미치는 영향)

  • Han, Man-Bae
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.4
    • /
    • pp.72-77
    • /
    • 2011
  • This study is to investigate the effect of the distillation temperature in ultra low sulfur diesel fuel on exhaust emissions in the low-temperature diesel combustion with 1.9L common rail direct injection diesel engine. Low temperature diesel combustion was achieved by adopting an external high EGR rate with a strategic injection control. The engine was operated at 1500 rpm 2.6 bar BMEP. The 90% distillation recovery temperature (T90) was $270^{\circ}C$ and $340^{\circ}C$ for the respective cetane number (CN) 30 and 55. It was found that there exists no distinctive discrepancy on exhaust emissions with regards to the different T90s. The high CN (CN55) fuels follow the similar trend of exhaust emissions as observed in CN30 fuels' except that high T90 fuel (CN55-T340) produced higher PM compared to low T90 fuel (CN55-T270). This may come from that high T90 plays an active role in aggravating the degree of fuel-air mixture preparedness before ignition.

A study on response analysis of submerged floating tunnel with linear and nonlinear cables

  • Yarramsetty, Poorna Chandra Rao;Domala, Vamshikrishna;Poluraju, P.;Sharma, R.
    • Ocean Systems Engineering
    • /
    • v.9 no.3
    • /
    • pp.219-240
    • /
    • 2019
  • This paper presents the comparison between SFT response with linear and nonlinear cables. The dynamic response analysis of submerged floating tunnel (SFT) is presented computationally with linear and nonlinear tension legs cables. The analysis is performed computationally for two wave directions one at 90 degrees (perpendicular) to tunnel and other at 45 degrees to the tunnel. The tension legs or cables are assumed as linear and non- linear and the analysis is also performed by assuming one tension leg or cable is failed. The Response Amplitude Operators (RAO's) are computed for first order waves, second order waves for both failure and non-failure case of cables. For first order waves- the SFT response is higher for sway and heave degree of freedom with nonlinear cables as compared with linear cables. For second order waves the SFT response in sway degree of freedom is bit higher response with linear cables as compared with nonlinear cables and the SFT in heave degree of freedom has higher response at low time periods with nonlinear cables as compared with linear cables. For irregular waves the power spectral densities (PSD's) has been computed for sway and heave degrees of freedom, at $45^0$ wave direction PSD's are higher with linear cables as compared with nonlinear cables and at $90^0$ wave direction the PSD's are higher with non-linear cables. The mooring force responses are also computed in y and z directions for linear and nonlinear cables.

A Comparative Study of PISO, SIMPLE, SIMPLE-C Algorithms in 3-dimensional Generalized Coordinate Systems (3차원 일반 좌표계에서의 PISO, SIMPLE, SIMPLE-C 알고리즘의 비교)

  • Park J. Y.;Baek J. H.
    • Journal of computational fluids engineering
    • /
    • v.1 no.1
    • /
    • pp.26-34
    • /
    • 1996
  • The performance of the SIMPLE, SIMPLE-C and PISO algorithms for the treatment of the pressure-velocity coupling in fluid flow problems were examined by comparing the computational effort required to obtain the same level of the convergence. Example problems are circular duct and 90-degree bent square-duct. For circular duct case, laminar and turbulent flow were computed. For 90-degree bent square-duct case, laminar flow was simulated by the time-marching method as well as the iterative method. The convergence speed of the other two algorithms are not always superior to SIMPLE algorithm. SIMPLE algorithm is faster than SIMPLE-C algorithm in the simple laminar flow calculations. The application of the PISO algorithm in three dimensional general coordinates is not so effective as in two-dimensional ones. Since computational time of PISO algorithm is increased at each time step(or iterative step) in three dimension, the total convergence speed is not decreased. But PISO algorithm is stable for large time step by using time marching method,.

  • PDF