• 제목/요약/키워드: 8Cr steel

검색결과 135건 처리시간 0.024초

고질소 Fe-l8Cr-l8Mn-2Mo-0.9N 강의 미끄럼 마멸 기구 (Sliding Wear Mechanism of the High-Nitrogen Austenitic 18Cr-l8Mn-2Mo-0.9N Steel)

  • 김승덕;김성준;김용석
    • 소성∙가공
    • /
    • 제15권2호
    • /
    • pp.112-117
    • /
    • 2006
  • Sliding wear mechanism of a high nitrogen austenitic 18Cr-18Mn-2Mo-0.9N steel has been investigated. Dry sliding wear tests of the steel were carried out at various loads of IN-10N under a constant sliding speed condition of 0.15m/s against AISI 52100 bearing steel balls. Solution ($1050^{\circ}C$) and isothermal aging ($900^{\circ}C$) heat treatments were performed on the steel and the effect of the heat treatments on the wear was investigated. Wear rates of the solution-treated steel specimen remained low until 5N load, and then increased abruptly at loads above 5N. The rates of isothermally aged specimens were low and increased gradually with the applied load. Worn surfaces, their cross sections, and wear debris of the steel specimens were examined with a scanning electron microscopy. Phases of the heat-treated specimen and the wear debris were identified using XRD. The transformed phase underneath a sliding track was investigated and analyzed using a TEM. Effects of the phase transformation during the wear and $Cr_{2}N$ precipitates formed during the isothermal aging on the wear of the austenitic steel were discussed.

Laboratory Tests of Chromium-51 Complexes for teak Detection in Pipes Carrying A Liquid Flow

  • Kim, You-Sun;Lee, Byung-Hyun
    • Nuclear Engineering and Technology
    • /
    • 제6권4호
    • /
    • pp.231-237
    • /
    • 1974
  • 유동액체를 수송하는 도관 또는 폐용기의 누설의 탐지 및 위치한정을 위하여 $^{51}$ Cr-EDTA및 $^{51}$ Cr-DTPA를 합성하고 Column Experiment 그리고 PH를 변화시켜 Batch equilibrium Experiment를 하였다. Column Experiment에서 $^{51}$ Cr-EDTA의 회수율은 Quartz sand에서 100%, Steel sawdust에서 80.9% 그리고 $^{51}$ Cr-DTPA는 Quartz sand에서 77.4%, Steel sawdust에서 6.4%이다. Recovery curve는 Steel sawdust $^{51}$ Cr-DTPA system에서 예외로 일정한 Plateau 를 표시하지 않는다. Batch Equilibrium Experiment에서 분배계수 Kd와 pH와의 관계를 Quartz asand, Montmorillonite, steel sawdust 그리고 Mixed Cement Raw Material둥을 매질로 하여 검토하였다. 일반적으로 $^{51}$ Cr-EDTA에 대한 Kd값이 $^{51}$ Cr DTPA에 대한 그것보다 낮다. $^{51}$ Cr-EDTA에 대한 Kd값이 pH 6.0, 7.0, 그리고 8.0에서 거의 0이 된다.

  • PDF

냉간금형강의 미세조직과 기계적 특성: STD11과 8%Cr 강의 비교 (Microstructures and Mechanical Properties of Cold-Work Tool Steels: A Comparison of 8%Cr Steel with STD11)

  • 김호영;강전연;손동민;이대수;이태호;정우창;조경목
    • 열처리공학회지
    • /
    • 제27권5호
    • /
    • pp.242-252
    • /
    • 2014
  • A comparative study was performed on the microstructures and the mechanical properties of STD11 and 8Cr steel. The specimens were quenched from $1030^{\circ}C$ and tempered at $240^{\circ}C$ and $520^{\circ}C$. Vickers hardness, impact toughness and tensile tests were conducted at various tempering temperatures. Microstructural characterization to measure grain size, volume fraction of retained austenite and distribution of carbides was carried out by using SEM, EBSD, TEM and X-ray diffraction techniques. Due to finer $M_7C_3$ carbides dispersed, 8Cr steel showed larger impact toughness and plasticity than STD11 irrespective of the tempering temperature. While 8Cr steel had lower hardness in as-quenched state and after tempering at $240^{\circ}C$ owing to smaller carbide content and more retained austenite, it was harder after tempering at $520^{\circ}C$ due to larger precipitation hardening from finer $M_{23}C_6$.

전기화학적 분극법을 이용한 12Cr강의 고온 재질열화도 평가 (Evaluation of High Temperature Material Degradation for 12Cr Steel by Electrochemical Polarization Method)

  • 서현욱;박기성;윤기봉
    • 대한기계학회논문집A
    • /
    • 제30권8호
    • /
    • pp.965-975
    • /
    • 2006
  • High pressure turbine blades are one of the key components in fossil power plants operated at high temperature. The blade is usually made of 12Cr steel and its operating temperature is above $500^{\circ}C$. Long term service at this temperature causes material degradation accompanied by changes in microstructures and mechanical properties such as strength and toughness. Quantitative assessment of reduction of strength and toughness due to high temperature material degradation is required for residual life assessment of the blade components. Nondestructive technique is preferred. So far most of the research of this kind was conducted with low alloy steels such as carbon steel, 1.25Cr0.5Mo steel or 2.25Cr1Mo steel. High alloy steel was not investigated. In this study one of the high Cr steel, 12Cr steel, was selected for high temperature material degradation. Electrochemical polarization method was employed to measure degradation. Strength reduction of the 12Cr steel was represented by hardness and toughness reduction was represented by change of transition temperature, FATT. Empirical relationships between the electrochemical polarization parameter and significance of material degradation were established. These relationship can be used for assessing the strength and toughness on the aged high pressure blade components indirectly by using the electrochemical method.

모 조선업체 아크 용접 작업자의 공기중 6가 크롬 및 니켈 노출에 관한 연구 (Welder's Exposure to Airborne Hexavalent Chromium and Nickel during Arc Welding in a Shipyard)

  • 신용철;이광용;이나루;오세민;강성규;문영한;이기라
    • 한국산업보건학회지
    • /
    • 제8권2호
    • /
    • pp.209-223
    • /
    • 1998
  • The aim of this study was to evaluate welders' exposure to hexavalent chromium (Cr(VI)) and nickel (Ni) during welding operations in a Korean shipyard. The airborne Cr(VI) and Ni concentrations were measured during metal inert gas (MIG) welding on mild and stainless steel, and manual metal arc (MMA) welding on mild steel. The geometric mean (GM) of Cr(VI) concentrations inside the welding helmet during MIG welding on mild steel were $0.0018mg/m^3$ inside a ship section, and $0.0015-0.0026mg/m^3$ at the welding shops. All of the personal breathing zone air samples were below the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value ($TLV^{(R)}$) of $0.01mg/m^3$. Conversely, eighty-eight percent(21 of 24) of the personal breathing zone air samples exceeded the National Institute for Occupational Safety and Health (NIOSH) recommended exposure limit of $0.001mg/m^3$. Ni was not detected on 20 of 23 air samples collected during MIG welding on mild steel. The three Ni samples above the limit of detection ranged from 0.015 to $0.044mg/m^3$. The GM of Cr(VI) concentrations during MMA welding on mild steel were $0.0013mg/m^3$, but Ni was not detected in the air samples during this operation. It is assumed that the airborne Cr(VI) and Ni during mild steel welding were derived from the base metals which contained about 0.03% Cr and 0.03% Ni. The GM of airborne total Cr, Cr(VI) and Ni concentrations during MIG welding on stainless steel were 4.02, 0.13 and $0.86mg/m^3$, respectively, and the levels of Cr(VI) and Ni were above the ACGIH-$TLV^{(R)}$. Cr(VI) comprised about 35.5% of the total chromium(Cr) from MIG welding on mild steel, and about 8.4% of total Cr from MIG welding on stainless steel. The ratios of Cr(VI) to total Cr were significantly different among welding shops. It was concluded that welders were exposed to high levels of Cr(VI) and Ni during welding on stainless steel, and were exposed to low levels of Cr(VI) even during welding on mild steel.

  • PDF

12% Cr 로터강의 강도 개선에 관한 연구 (Study on the Improvement of Strength for 12% Chromium Steel Rotor)

  • 장윤석;오세욱
    • 한국해양공학회지
    • /
    • 제3권2호
    • /
    • pp.125-137
    • /
    • 1989
  • To check technical improvement in the soundness and strength of 12% Cr steel rotor, a 25 tons of rotor with 65 tons of ingot was made in real size and was cut to pieces to take test samples, and the various mechanical tests such as impact, tensile, creep, and fatigue were carried out. The strengths are compared with those of 1% Cr-Mo-V rotor of same size. Microstructures of the samples are examined and reviewed. The results can be summarized as follows. 1) Fracture appearance transition temperatures are 80.deg. C at the center part and 60.deg. C near surface of 12% Cr rotor, and 8.deg. C near surface of 1% Cr-Mo-V rotor. 2) Comparative rapid softening occurs at higher temperatures above 600.deg. C for 12% Cr steel and 550.deg. C for 1% Cr-Mo-V steel in tension tests. 3) Fatigue crack propagation rate of 12% Cr steel is almost same as that of 1% Cr-Mo-V steel at the same corresponding surface part of the rotors. The crack growth rate of center part of 12% Cr rotor is faster than near surface part of the rotor, and the crack growth rate at the load condition of R=0.04 is slower than that of the load condition of R=0.5 for both 12% Cr steel and 1% Cr-Mo-V steel. 4) Crack growth rate of radial direction near surface of 12% Cr rotor is faster than that of transverse direction at the same part because of the difference in residual stresses. 5) Both creep and fatigue strengths of 12% Cr steel are superior to those of 1% Cr-Mo-V steel and the difference is thought the effect of climb and glide controlled creep by solid solution of alloying elements and dispersion of carbides.

  • PDF

12% Cr 로터강의 강도 개선에 관한 연구 (Study on the Improvement of Strength for 12% Chromium Steel Rotor)

  • 장윤석;오세욱
    • 한국해양공학회지
    • /
    • 제3권2호
    • /
    • pp.625-625
    • /
    • 1989
  • To check technical improvement in the soundness and strength of 12% Cr steel rotor, a 25 tons of rotor with 65 tons of ingot was made in real size and was cut to pieces to take test samples, and the various mechanical tests such as impact, tensile, creep, and fatigue were carried out. The strengths are compared with those of 1% Cr-Mo-V rotor of same size. Microstructures of the samples are examined and reviewed. The results can be summarized as follows. 1) Fracture appearance transition temperatures are 80.deg. C at the center part and 60.deg. C near surface of 12% Cr rotor, and 8.deg. C near surface of 1% Cr-Mo-V rotor. 2) Comparative rapid softening occurs at higher temperatures above 600.deg. C for 12% Cr steel and 550.deg. C for 1% Cr-Mo-V steel in tension tests. 3) Fatigue crack propagation rate of 12% Cr steel is almost same as that of 1% Cr-Mo-V steel at the same corresponding surface part of the rotors. The crack growth rate of center part of 12% Cr rotor is faster than near surface part of the rotor, and the crack growth rate at the load condition of R=0.04 is slower than that of the load condition of R=0.5 for both 12% Cr steel and 1% Cr-Mo-V steel. 4) Crack growth rate of radial direction near surface of 12% Cr rotor is faster than that of transverse direction at the same part because of the difference in residual stresses. 5) Both creep and fatigue strengths of 12% Cr steel are superior to those of 1% Cr-Mo-V steel and the difference is thought the effect of climb and glide controlled creep by solid solution of alloying elements and dispersion of carbides.

페라이트기 9Cr 내열강의 크리프-피로손상에 따른 미세조직 및 초음파 비파괴평가 (Microstructural Evolution and Ultrasonic Nondestructive Evaluation During Creep-Fatigue of 9Cr Ferritic Heat-Resisting Steel)

  • 김정석;권숙인;박익근
    • 한국재료학회지
    • /
    • 제17권8호
    • /
    • pp.425-432
    • /
    • 2007
  • The microstructural evolution of ferritic 9Cr-1Mo-V-Nb steel, subjected to creep-fatigue at $550^{\circ}C$, was evaluated nondestructively by measuring the ultrasonic velocity. The variation of the ultrasonic velocity with the fatigue life fraction exhibited three regions. In the first region ($N/N_f$<0.2), a significant increase in the velocity was observed, followed by a slight increase between the fatigue life fractions of $0.2N_f$ and $0.8N_f$, and then a decrease in the final region. The change of the ultrasonic velocity during creep-fatigue was interpreted in relation to the microstructural properties. This study proposes an ultrasonic nondestructive evaluation method of quantifying the level of damage and microstructural change during the creep-fatigue of ferritic 9Cr-1Mo-V-Nb steel.

진공증착법으로 제조된 Zn-Cr박막의 특성에 관한 연구 (A Study on the Properties of the Zn-Cr Alloy Films by Evaporation)

  • 주봉환;이규환;권식철;백운승
    • 연구논문집
    • /
    • 통권23호
    • /
    • pp.109-120
    • /
    • 1993
  • A study on corrosion and adhesion properties of evaporated Zn-Cr films were conducted on steel strip by two-source evaporater. Corrosion resistance of Zn-Cr coated steel was evaluated by salt spray test in 5% NaCl. Adhesion property of Zn-Cr films on steel substrate was evaluated by tape test after $180^\circC$ bending. Adhesion was improved with increasing the Cr content and reached the maximum at the Cr content of 6 to 8wt%. Corrosion resistance was enhanced with increasing the Cr content and improved by rolling Zn-Cr coated specimen, as a post-treatment.

  • PDF