• Title/Summary/Keyword: 7mm or less

Search Result 364, Processing Time 0.027 seconds

Outcome of Nonoperative Treatment for Proximal Plantar Fasciitis: Comparative Analysis According to Plantar Fascia Thickness (근위 족저 근막염의 비수술적 치료 결과 : 족저 근막 두께에 따른 비교 분석)

  • Yoon, Kwang-Sup;Jung, Hong-Geun;Bae, Eui-Jung;Kim, Tae-Hoon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.12 no.2
    • /
    • pp.122-127
    • /
    • 2008
  • Purpose: To evaluate the clinical outcome of proximal plantar fasciitis after nonoperative treatment, and also to find the correlation of the heel pain with the plantar fascia thickness measured by ultrasonography. Materials and Methods: The study is based on 41 patients, 46 feet of the proximal plantar fasciitis that were treated conservatively with at least 12 months follow-up. All were treated with heel pad, Achilles and plantar fascia stretching and pain medications for at least 3 months. Heel ultrasonography was performed at the beginning of the treatment to measure the plantar fascia (PF) thickness and the echogenicity. PF thickness over 4 mm and less were grouped in to group A and B respectively to compare the clinical outcome. Results: Average thickness of the PF at the calcaneal attach was 5.2 mm. Symptom duration before the treatment was average 13.2 month; group A being 14.6 months and group B being 9.0 months with no significant difference (p=0.09). As functional evaluation, Roles-Maudsley score improved from 3.4 initially to 2.3 at final follow-up, while morning heel pain also improved from average VAS pain score of 7.2 to 4.0. However Maudsley and VAS score both didn't show statistical difference between the 2 groups (p>0.05). Conclusion: Plantar fasciitis improved substantially with the nonoperative treatments. However, the 2 groups, divided according to 4 mm thickness by ultrasonography, didn't show significant difference in either symptom duration or in the clinical outcomes.

  • PDF

Manufacturing of Copper(II) Oxide Powder for Electroplating from NaClO3 Type Etching Wastes

  • Hong, In Kwon;Lee, Seung Bum;Kim, Sunhoe
    • Journal of Electrochemical Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.60-67
    • /
    • 2020
  • In this study, copper (II) oxide powder for electroplating was prepared by recovering CuCl2 from NaClO3 type etching wastes via recovered non-sintering two step chemical reaction. In case of alkali copper carbonate [mCuCo3·nCu(OH)2], first reaction product, CuCo3 is produced more than Cu(OH)2 when the reaction molar ratio of sodium carbonate is low, since m is larger than n. As the reaction molar ratio of sodium carbonate increased, m is larger than n and Cu(OH)2 was produced more than CuCO3. In the case of m has same values as n, the optimum reaction mole ratio was 1.44 at the reaction temperature of 80℃ based on the theoretical copper content of 57.5 wt. %. The optimum amount of sodium hydroxide was 120 g at 80℃ for production of copper (II) oxide prepared by using basic copper carbonate product of first reaction. At this time, the yield of copper (II) oxide was 96.6 wt.%. Also, the chloride ion concentration was 9.7 mg/L. The properties of produced copper (II) oxide such as mean particle size, dissolution time for sulfuric acid, and repose angle were 19.5 mm, 64 second, and 34.8°, respectively. As a result of the hole filling test, it was found that the copper oxide (II) prepared with 120 g of sodium hydroxide, the optimum amount of basic hydroxide for copper carbonate, has a hole filling of 11.0 mm, which satisfies the general hole filling management range of 15 mm or less.

Dissolved organic matter characteristics and bacteriological changes during phosphorus removal using ladle furnace slag

  • Noh, Jin H.;Lee, Sang-Hyup;Choi, Jae-Woo;Maeng, Sung Kyu
    • Membrane and Water Treatment
    • /
    • v.9 no.3
    • /
    • pp.181-188
    • /
    • 2018
  • A sidestream contains the filtrate or concentrate from the belt filter press, filter backwash and supernatant from sludge digesters. The sidestream flow, which heads back into the sewage treatment train, is about 1-3% less than the influent flow. However, the sidestream can increase the nutrient load since it contains high concentrations of phosphorus and nitrogen. In this study, the removal of PO4-P with organic matter characteristics and bacteriological changes during the sidestream treatment via ladle furnace (LF) slag was investigated. The sidestream used in this study consisted of 11-14% PO4-P and 3.2-3.6% soluble chemical oxygen demand in influent loading rates. LF slag, which had a relatively high $Ca^{2+}$ release compared to other slags, was used to remove $PO_4-P$ from the sidestream. The phosphate removal rates increased as the slag particle size decreased 19.1% (2.0-4.0 mm, 25.2% (1.0-2.0 mm) and 79.9% (0.5-1.0 mm). The removal rates of dissolved organic carbon, soluble chemical oxygen demand, color and aromatic organic matter ($UV_{254}$) were 17.6, 41.7, 90.2 and 77.3%, respectively. Fluorescence excitation-emission matrices and liquid chromatography-organic carbon detection demonstrated that the sidestream treatment via LF slag was effective in the removal of biopolymers. However, the removal of dissolved organic matter was not significant during the treatment. The intact bacterial biomass decreased from $1.64{\times}10^8cells/mL$ to $1.05{\times}10^8cells/mL$. The use of LF slag was effective for the removal of phosphate and the removal efficiency of phosphate was greater than 80% for up to 100 bed volumes.

Usefulness of Dual-Echo in Steady State (DESS) Image in Chondromalacia of Knee Joint: Comparison of DESS and Turbo Spin-Echo MR Images (슬관절 연골 연화증의 진단에서의 Dual Echo in Steady State (DESS) 영상의 유용성 : 급속 스핀에코 자기공명 영상과 비교)

  • 윤삼현;하두회
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.1
    • /
    • pp.66-72
    • /
    • 1999
  • Purpose : To evaluate the usefulness of Dual Echo in Steady State(DESS) image in the diagnosis of chondromalacia of the knee compared with turbo spin-echo MR images Materials and Methods : We included 26 patients with chondromalacia of the knee. MR imaging was obtained with a 1.5T imager. Sagittal and coronal double echo T2 weighted images(TR/TE 3000-4200/16-96msec, FOV $140-160{\times}140-160mm$, matrix size $180{\times}256$, slice thickness 4.0mm, interslice gap 0.5mm), and sagittal DESS image(TR/TE 25.4/9.0msec, flip angle $35-45^{\circ}$, FOV $150-160{\times}150-160mm,{\;}matrix{\;}size{\;}192{\times}256$, effective slice thickness 1.5mm) were obtained. Cartilage lesions were staged according to a modified scheme proposed by Outerbirdge: grade 0, normal; grade 1, softening or/and swelling; grade 2, mild surface fibrillation or/and less than 50% of cartilage thickness; grade 3, severe surface fibrillation or/and loss of more than 50% of cartilage thickness but without exposure of subchondral bone; and grade 4, complete loss of cartilage with subchondral bone exposure. Gradings were determined by two readers with consensus, and patellofemoral, medial and lateral tibiofemoral compartments were evaluated. Results : Arthroscopic findings revealed grade 1 in seven cases, grade 2 in 21 cases, grade 3 in six cases, and grade 4 in 18 cases. Sensitivity of turbo spin-echo MR image was as follows; 0%, 14%, 0%, 61% in each grade, and sensitivity of DESS image was as follows; 0%, 33%, 50%, 67%, in each grade(p=0.001). In the detection of chondromalacic lesions regardless of gradings, sensitivity, specificity and accuracy of conventional MR image were 59.6% 88.6% 78.8%, and of DESS image, 73.1% 88.4%, 82.2%(p=0.007). Conclusion : For chondromalacia of knee joints, DESS images showed higher sensitivity than turbo spin-echo MR images. Therefore, DESS images will be helpful for diagnosis of chondromalacia of knee joints.

  • PDF

Reduction of Electron Contamination in Photon Beam by electron Filter in 6MV Linear Accelerator (6MV 선형가속기에서 Al/Cu에 관한 여과판 사용시 전자오염 감소에 관한 연구)

  • Lee, Cheol-Su
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.8 no.1
    • /
    • pp.41-54
    • /
    • 1996
  • The secondary electrons developed by interaction between primary beam and a tray mounted for blocks in Megavoltage irradiation result in excess soft radiation dose to the surface layer. To reduce this electron contamination, electron filters have been used to be attached under a tray. Various filters with Cu and Al plates in six different thickness and Cu/Al combined plates in 3 different thickness were tested to measure the reduction rate of secondary electron contamination to the surface layer. The measurement to find optimal filter was performed on 6MV linear accelerator in $10 cm{\times}10 cm$ field size and fixed 78.5cm source to measurement points distance from surface to maximum build up point in 2mm intervals. The result was analyzed as the ratio of measured doses with using filters, to standard doses of measured open beam. The result of this study was fellowing : 1. The contaminated low energy radiation were mainly produced by blocking tray. 2. The surface absorbed dose was slowly increased by increasing irradiation field size but rapidly increased at field size above $15cm{\times}15cm$. 3. Al plate upto 2.5mm thickness used as a filter was found to be inadequate due to the failure of reduction of the surface absorbed dose below doses of the under surface upto the maximal build up. Cu 0.5mm plate and Cu 0.28mm/A1 1.5mm compound plate were found to be optimal filters. 4. By using these 2 filters, the absorbed dose to the surface were effectively reduced $5.5\%$ in field size $4cm{\times}4cm,\;11.3\%$ in field size $10cm{\times}10cm,\;22.3\%$ in field size $25cm{\times}25cm$. 5. In field size $10cm{\times}10cm$, the absorbed dose to the surface of irradiation was reduced by setting TSD 20cm at least,. but effective and enough dose reduction could be achieved by setting TSD 30cm as 2 optimal filters used. 6. More surface dose absorbed at TSD less than 7.4cm with a tray and filters together indicated that soft radiation was also developed by filters. 7. The variation of PDD by the different size of irradiation field was minimal as 2 optimal filters used. There was also not different in variation of PDD according to using any of two different filters. 8. PDD was not effected either by various TSD or by using the different filter among two.

  • PDF

Freshness Extension of Ginseng with Freezing Point Depressing Agents (빙점강하제를 이용한 수삼의 선도연장)

  • 남궁배;정문철;김동만;문광덕;최종욱
    • Food Science and Preservation
    • /
    • v.7 no.1
    • /
    • pp.57-62
    • /
    • 2000
  • Ginseng was stored at a temperature lower than the freezing point after a treatment of freezing point depressing agents to extend its freshness. Respiration rate at freezing point of ginseng, -1.7${\pm}$0.1$^{\circ}C$, was inhibited 92% and 97% compared with those stored at 5$^{\circ}C$or 20$^{\circ}C$ , respectively. Sorbitol solution chosen as a freezing point depressing agent lowered the freezing point of ginseng to about -3.0$^{\circ}C$. Ginsengs treated with the sorbitol solution and packaged with 0.06mm LDPE was stored at -2$^{\circ}C$ , and the quality change was then compared with ginsengs stored at 0$^{\circ}C$ and 5$^{\circ}C$. Weight loss of ginsengs stored at -2$^{\circ}C$ for 100days was 1.5%, which is about 2.6times less than those stored at 5$^{\circ}C$. However, there were no significant difference between the ginsengs stored at -2$^{\circ}C$ and at 0$^{\circ}C$(1.9%). Spoilage rate of the ginsengs was 100% after 50 days of storage at 5$^{\circ}C$ and 25% after 100days at 0$^{\circ}C$respectively. but that of ginsengs stored at -2$^{\circ}C$ was 13%, which was half than that of ginsengs stored at 0$^{\circ}C$. Firmness and amount of monoscaccharides in ginsengs were decreased during storage at 5 or 0$^{\circ}C$ but ginsengs stored at -2$^{\circ}C$ showed better firmness and an increase in monosaccharides such as fructose and glucose. From above, when ginseng treated with freezing pont depressing agents were stored at -2$^{\circ}C$, the shelf life was extended to 2 or 3 times longer than those that were stored at 5 or 0$^{\circ}C$, respectively.

  • PDF

Continuous "Over and Over" Suture for Tricuspid Ring Annuloplasty

  • Park, Kwon-Jae;Woo, Jong-Soo;Jeong, Sang-Seok;Yi, Jung-Hoon
    • Journal of Chest Surgery
    • /
    • v.45 no.1
    • /
    • pp.19-23
    • /
    • 2012
  • Background: A ring implantation in the tricuspid annulus requires many interrupted mattress sutures for correction of tricuspid regurgitation (TR). In this study, tricuspid ring annuloplasty was performed by 2-0 polypropylene continuous suture instead of multiple interrupted 2-0 polyester mattress sutures, and the efficacy of the method was evaluated. Materials and Methods: This study included 20 patients who underwent tricuspid ring annuloplasty by continuous suture between May 2009 and July 2010. Four of the patients had an isolated TR, and the rest had a left-sided cardiac lesion. The concomitant tricuspid annuloplasty was performed after the left-sided heart surgery was completed and a Duran flexible ring prosthesis was used. Results: There was no perioperative mortality or conduction problem. More than a moderate degree of TR was improved to less than a mild degree after the procedure. After the ring annuloplasty, the right atrial volume decreased from $123.7{\pm}69.2mL$ to $74.5{\pm}37.4mL$, and the mean right atrial pressure was lowered from $18.7{\pm}12.2mmHg$ to $8.9{\pm}5.5mmHg$. Conclusion: The continuous "over and over" suture may be a useful procedure for fixing the ring to the annulus and making an intentional annular placation in performing tricuspid ring annuloplasty.

Molecular and Morphological Identification of Ophichthid Leptocephali from the South Sea of Korea (남해에서 채집된 바다뱀과 엽상자어(Leptocephali)의 형태 및 분자 동정)

  • Ji, Hwan-Sung;Kim, Jin-Koo
    • Korean Journal of Ichthyology
    • /
    • v.22 no.4
    • /
    • pp.279-284
    • /
    • 2010
  • Four leptocephali (TL 109.8~129.7 mm) of the family Ophichthidae, collected from Sangju in the South Sea of Korea, were identified using morphological and molecular methods. Our four leptocephali were similar to Ophichthus sp. based on morphological characters: the melanophores present in series of eight gut swellings; total myomeres 144~151; body depth in total length less than 10%; eight or nine black horizontal bands present from anus to caudal fin base. On the other hand, our four leptocephali were identified to Pisodonophis sp. based on 826 base pairs of 12S rRNA gene nucleotide sequences. Our results showed that morphology-based identification did not agree with molecular identification, indicating difficulty in differentiating morphologically between Ophichthus and Pisodonophis leptocephali. We, herein, firstly describe morphological characteristics of Pisodonophis sp. leptocephali from Korea.

Symptomatology of Citrus mosaic sadwavirus (CiMV) in Some Citrus Cultivars and Effect of CiMV Infection on Citrus Fruit Quality

  • Hyun, Jae Wook;Hwang, Rok Yeon;Choi, Cheol Woo;Jung, Kyung Eun;Han, Seung Gab
    • The Plant Pathology Journal
    • /
    • v.36 no.1
    • /
    • pp.106-110
    • /
    • 2020
  • Citrus mosaic sadwavirus (CiMV) is a closely related virus with the Satsuma dwarf virus (SDV) along with Navel orange infectious mottling virus (NIMV), Natsudaidai dwarf virus (NDV), and Hyugagatsu virus (HV). The present study found that the typical symptoms of CiMV-infected citrus fruits include the appearance of dark blue speckles or ringspots on fruit rinds and the browning of oil glands in the spots as rind coloring began. As rind coloring progressed, the spots gradually faded, whereas the browning of the oil glands worsened to the point that the tissues surrounding the oil glands became necrotic. In very early satsuma mandarins (Citrus unshiu 'Miyamoto Wase') and 'Setoka' cultivar (C. hybrid 'Setoka') of late-maturity citrus, the symptomatic fruits were eventually dropped. And in early satsuma mandarin (C. unshiu 'Miyakawa Wase'), the peel hardness of the virus-infected fruit (1,618.3 ± 305.5, g-force) was more than twice as hard as that of the healthy fruit (636.5 ± 39.1, g-force). The ratio of flesh weight to total fruit weight was higher for the healthy fruit (77.3 ± 1.7%) than for the infected fruit (70.7 ± 0.6) and peel puffing was more severe in the infected fruit (2.9 ± 0.4 mm) than in the healthy fruit (0.9 ± 0.2 mm). The soluble solids content in infected citrus fruits was less values than the healthy fruit by 0.5-1.5 °Brix. These findings reveal that CiMV infection on citrus trees reduces the fruit quality of citrus.

The study on the variable orifice spray of the steam power plant desuperheater (화력발전설비의 과열증기저감용 가변오리피스 분사 특성)

  • Kim, Jeong-Sik;Kim, Kwang-Hee;Lee, Jong-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.63-68
    • /
    • 2013
  • The steam power plant is becoming more important to supply a stable power lately. Desuperheater of the steam power plant facility plays a role in maintaining the proper superheat to avoid damage turbine power due to the superheated steam produced in the boiler. In this study, when the steam flows $530^{\circ}C$, 36.7 kg/s, 1.36 MPa in the 460mm pipe, variable orifice nozzle developed in Korea was carried out the performance analysis in coolant injection conditions of $150^{\circ}C$, 4.28 MPa. Findings, steam pipe coolant temperature was maintained at $446^{\circ}C$ and sprayed droplet size was verified by $50{\mu}m$ or less.