• 제목/요약/키워드: 7mm or less

검색결과 364건 처리시간 0.03초

작은 기계 판막을 이용한 대도액 판막 치환술 후 판막 전후 압력차 (transprosthetic Pressure Gradient after aortic Valve Replacement with Small Sized Prostheses)

  • 황경환;박계현;차대원;전태국;박표원;채헌
    • Journal of Chest Surgery
    • /
    • 제33권2호
    • /
    • pp.146-150
    • /
    • 2000
  • background: The prognosis after an aortic valve replacment can be affected significantly by the transprosthetic pressure gradient which is determined mainly by the size of the patients body and the prosthesis used. We analyzed the hemodynamic feature of two relatively new prosthese the ATS and the evensized Medtronic-Hall(M-H) valves by measuring the transprosthetic pressure gradient in the cases where small sizes (23mm or smaller) were used. Material and method: There were 94 patients who received whom aortic valve replacement with prosthesis smaller than 23 mm from October 1994 to June 1998. In these patients the transprosthetic pressure gradient clalculated from the pressure half time during postoperative Dopper echocardiographic examination was compared between the prostheses of different sizes. The body surface area of each patient was also taken into consideration. result: The mean pressure gradient and body surface area in each group were 21.7$\pm$10.2 mmHg and 1.52$\pm$0.14m2 in ATS 19mm 11.4$\pm$6.5 mmHg and 1,57$\pm$0.20m2 in M-H 20mm 15.2$\pm$6.3 mmHg and 1.54$\pm$0.13m2 in ATS 21mm 9.3$\pm$2.5 mmHg and 1.63 $\pm$0.14m2 in M-H 22 mm and 12.9$\pm$5.3 mmHg and 1.69$\pm$0.13m2 in ATS 23mm. Conclusion: The 19mm ATS prosthesis showed significant trasprosthetic pressure gradient which is similar to the values previously reported with other bileaflet prosthesesm Close follow-up was needed in terms of exercise capacity and change in left ventiricular geometry. In patients with small aortic valve annulus the 20mm M-H valve is recomendable as an alternative to 19mm bileaflet valves because it has less pressure gradient with similar outer diameter.

  • PDF

30nm~3000nm 광범위 직경 입자의 공기역학적 집속에 대한 수치해석 (A Numerical Simulation of Aerodynamic Focusing of Nanoparticles in a Wide Range of 30nm~3000nm)

  • 이광승;이동근
    • 한국입자에어로졸학회지
    • /
    • 제7권4호
    • /
    • pp.123-130
    • /
    • 2011
  • Previous designs of conventional aerodynamic lenses have a limitation of narrow range of focusable particle size, e.g. 30 to 300nm or 3 to 30nm. To enlarge the focusable size range to 30-3000nm, it is necessary to avoid a significant loss of particles larger than 300nm inside the lenses. From numerical simulations on size-resolved particle trajectories, we confirmed that the traveling losses of such large particles could be avoided only when the radial position of particles approaching the orifice lens was near the lens axis. Hence, we designed the lens system consisting of a converging-diverging nozzle and 7 orifices to fulfill the requirement. In particular, the orifices were aligned in a way that their diameters were descending and ascending to the downstream. As a result, 30-2800nm particles can be focused to the particle beam of 0.2mm or less in radius with above 85% transmission efficiency. Even $10{\mu}m$ particles can be focused with 74% of transmission efficiency.

산지에 서식하는 뿔가위벌류의 분포와 채집 (Distribution and Collection of Osmia Bees in the Mountain Areas of Korea)

  • 이순원;최경희;이동혁;김동아;류하경;이영인
    • 한국응용곤충학회지
    • /
    • 제41권4호
    • /
    • pp.263-267
    • /
    • 2002
  • 사과원에서 꿀벌 대신에 화분매개곤충으로 유망한 뿔가위벌류의 활용을 목적으로, 1996년부터 1998년까지 각각 전국 66, 52, 60개소 산지에 내경 6-8mm인 대나무대롱을 설치하여, 자생하고 있는 뿔가위벌류의 종별 분포와 채집량을 조사하였다. 머리뿔가위벌, 뿔가위벌, 붉은뿔가위벌, 외뿔가위벌, 꼬마민뿔가위벌의 5종이 채집되었으며, 각종별 점유율은 각기 39.9-51.7, 28.3-53.7, 5.5-19.1, 0.8-0.9, 0-0.1%였다. 매년 머리뿔가위벌과 뿔가위벌 2종이 전체 채집량의 80%내외였으며, 채집량이 많은 5개지역중 원주지역에서 머리뿔가위벌이 우점종이었고, 나머지 4개지역(안성, 괴산, 봉화, 구미)에서는 뿔가위벌이 우점종이었다. 암컷의 비율은 머리뿔가위벌 29-43, 뿔가위벌 10-12, 붉은뿔가위벌 22-43%로 종간에 차이가 있었다. 3종 뿔가위벌류는 채집지역의 해발을 200m 이하, 300-400m, 500m 이상으로 구분하였을 때, 해발이 높아짐에 따라서 채집수가 많았고, 3종 뿔가위벌류중 머리뿔가위벌의 점유율이 높은 경향이었다. 3년간 동일장소에서 연속 채집할 경우 머리뿔가위벌과 붉은뿔가위벌은 연도가 경과할수록 채집량이 점차로 증가하는 경향이었으나, 뿔가위벌은 반대로 크게 감소하였다. 3종 뿔가위벌류가 대나무 대롱에 영소하는 시기는 3월 하순-4월 중순에 시작하여 5월 하순-6월 중순에 종료하였으며, 영소 최성기는 4월 하순-5월 중순이었다. 한편. 뿔가위벌류의 경쟁종인 구멍벌은 5월 하순-6월 중순에 시작하여 6월 하순-7월 중순에 가장 많이 영소하였고, 감탕벌은 4월 하순5월 중순에 시작하여 7월 하순8월 중순에 가장 많이 영소하였다.

10시 혹은 2시 방향의 경경골 대퇴 터널을 이용한 전방 십자 인대 재건술 후 2~4년 추시 결과 (Two to Four Year Follow-Up Results after Anterior Cruciate Ligament Reconstruction Using Transtibial Femoral Tunnel at 10 or 2 O'clock Position)

  • 조성도;염윤석;정지영;박한창
    • 대한관절경학회지
    • /
    • 제13권1호
    • /
    • pp.1-7
    • /
    • 2009
  • 목적: 10시 혹은 2시 방향의 경경골 대퇴 터널을 이용한 관절경적 전방 십자 인대 재건술 후 2-4년 추시 결과를 분석하고자 하였다. 대상 및 방법: 동종 경골건을 사용하여 전방 십자 인대 재건술을 시행하고 추시가 가능하였던 86예를 대상으로 하였다. 평가는 2000 International Knee Documentation Committee (IKDC) 주관적 슬관절 점수, Lachman 검사, Pivot-shift 검사, KT-1000 arthrometer 검사, 2000 IKDC 슬관절 검사 및 2차 관절경 검사를 포함하였다. 결과: IKDC 주관적 슬관절 점수는 80점 이상이 75예(87.2%), Lachman 검사상 1+ firm end 이하의 전위는 83예(96.5%), Pivot-shift 검사상 음성은 78예(90.7%), KT-1000 전방 전위 검사상 차이가 5 mm 이하인 경우는 83예(96.5%)였다. IKDC 슬관절 검사상 정상 또는 거의 정상이 80예(93.0%)였다. 2차 관절경 검사는 15예에서 시행되었으며 9예(60%)에서 전방 십자 인대 이식물의 양호한 활액막 형성을, 4예(26.7%)에서 부분적인 활액막 형성을, 2예(13.3%)에서 불량한 활액막 형성을 보였고 이식물의 실패는 1예(6.67%)가 있었다. 결론: 10시 혹은 2시 방향의 경경골 대퇴 터널을 이용한 전방 십자 인대 재건술은 전후방 안정성뿐만 아니라 회전 안정성에서 양호한 결과를 보여주었다.

  • PDF

Steri-Oss 임플랜트의 임상 결과에 관한 연구 (A STUDY OF CLINICAL RESULTS ON STERI-OSS ENDOSSEOUS IMPLANTS)

  • 민영규;권혁신;정재헌
    • 대한치과보철학회지
    • /
    • 제36권2호
    • /
    • pp.258-272
    • /
    • 1998
  • This investigation evaluated patients who received Steri-Oss implants from the Dental Hospital of Chosun University during the period from March 1989 to August 1997. 346 fixtures of 127 patients were included in this study. The results were as follows ; 1.The follow-up period was defined as the period between the surgical placement of the implants and the last follow-up examination. The mean follow-up period was $2.17{\pm}1.21$ years. 2.The period between fixture installation and second surgery was $0.71{\pm}0.44$ years in the maxilla and $0.46{\pm}0.21$ years in the mandible. 3.The number of fixtures which were installed in the upper jaw(112) was less than that in the lower jaw(234) and in the posterior region(260) was more than in the anterior region(86). 4.The length of fixture which was most frequently used was 12 mm and least was 8mm. Screw implants were installed more than cylindrical implants. 3.8mm implant was the most common implans, followed by 4.5mm and 3.25mm. 5.The number of augmentation cases was more than that of non-augmentation cases and the rate of augmentation cases in the maxilla was more than that in the mandible. 6.Implant restorations for partial edentulos patients(94cases) were more than single- tooth implant restorations(33cases) or implant restorations for complete edentulos patients(10cases). 7.Free-standing prostheses for partially edentulous patients were more commom than any other type of connection between implants and natural teeth. 8.Plaque Index($0.95{\pm}0.74$) and Gingival Index($0.31{\pm}0.52$) were very similar around the natural teeth and reflected an acceptable level of plaque and gingivitis control. Mean value for keratinized mucosa index($1.93{\pm}1.20$) remained fairly constant around level 2(1-2 mm keratinized epithelium). 9.Patients were generally satisfied with implant in terms of comfort, function, speech and esthetics. 10.There was not a statistically significant differences in overall survial rate between implants placed in the maxilla (91.5%) and those placed in the mandible (93.8%). Fourteen implants lost before the prosthetic rehabilitation and eleven implants lost following variable periods in function after the prosthetic phase of the treatment. 11.Cause of implant failures was exfoliation or removal of fixture due to non-osseointegration before the prosthetic rehabilitation or due to fracture of fixture, masticatory pain after the prosthetic rehabilitation. 12.The survival rate of Steri-Oss implants using the Kaplan-Meier statistical analysis was 93.8% at 2 year and 86.6% at 5 year, In all cases, implant losses occured predominantly in the healing period. There was a steep decline in the rate of implant loss after the first year. 13.The survival rate of Steri-Oss implants in the anterior region was 94.8% at 2 year and 94.8% at 5 year and that in the posterior region was 92.8% at 2 year and 75.9% at 5 year. In conclusion, this study revealed a number of parameters and guidelines for achieving an optimal success rate in osseointegration.

  • PDF

하프 커팅을 이용한 이중 슬리브를 갖는 직사각형 평면 모노폴 안테나에 관한 연구 (A Study on Rectangular Planar Monopole Antenna with a Double Sleeve Using Half Cutting)

  • 강상원;장대순;최광제
    • 한국인터넷방송통신학회논문지
    • /
    • 제17권2호
    • /
    • pp.257-262
    • /
    • 2017
  • 본 논문에서는 이중 슬리브를 갖는 직사각형 평면 모노폴 안테나에 하프 커팅과 불연속 급전 구조를 적용하여 안테나 특성을 확인하였다. 이중 슬리브를 갖는 직사각형 평면 모노폴 안테나를 자기 대칭 라인을 중심으로 하프커팅을 하고, 급전부에 불연속 구조를 적용과 이중 슬리브 간격을 조정하여 임피던스 매칭을 하였다. 안테나 파라미터 특성을 확인하기 위하여 ANSYS사의 HFSS 시뮬레이터를 이용하였고, 안테나 크기는 $21{\times}40mm^2$이다. 제안한 안테나에서 VSWR이 2 이하인 시뮬레이션 주파수 대역은 2.6GHz~10.25GHz이다. 주파수 대역폭은 7.65GHz이다. 실제로 제작한 안테나의 주파수 대역은 3.3GHz~9.75GHz이며, 주파수 대역폭은 6.45GHz이다. 측정된 복사패턴 주파수는 3.5GHz, 5.5GHz, 7.5GHz, 9.5GHz이다. 모든 주파수에서 다이폴안테나 패턴과 유사한 복사패턴 결과를 얻을 수 있었다.

결정성장형 무기재료 조성비에 따른 고상 캡슐의 자기치유 성능에 관한 실험적 연구 (An Experimental Study on the Self-Healing Performance of Solid Capsules According to the Composition Ratio of Crystal Growth Type Inorganic Materials)

  • 남은준;오성록;김철규;최연왕
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권2호
    • /
    • pp.16-22
    • /
    • 2021
  • 본 논문에서는 수화반응이 가능한 결정성장형 무기재료를 사용하여 고상 캡슐을 제조하였다. 고상 캡슐을 시멘트 질량 기준으로 8:2, 7:3, 및 6:4의 조성비에 따라 3, 5 및 10% 혼합하여 자기치유 모르타르 배합을 진행 하였으며, 정수위투수시험을 통해 내구적 치유 특성을 평가하였다. 정수위투수시험 실험결과, 고상 캡슐의 조성비 7:3으로 제조된 고상 캡슐을 혼합함에 따라 자연 치유성능을 최적으로 향상시키는 효과가 나타났다. 0.3 mm 이하 균열폭의 경우 약 90% 이상 자기치유 성능을 확보할 수 있을 것으로 판단된다. 이러한 결과, 고상 캡슐의 자기치유 성능은 정수위투수시험을 통하여 내구적 치유 특성에 영향이 있는 것으로 판단되며, 고상 캡슐의 혼합에 따라서 자기치유 성능을 향상시키는 경향이 있다고 판단된다.

성장중인 양서류 여포의 스테로이드 생성능력 획득에 관한 연구 (Development of Steroidogenic Capacity during Follicle Growth in Amphibian Ovarian Follicles)

  • 안련섭;소재목;임욱빈;나철호;권혁방
    • 한국동물학회지
    • /
    • 제39권3호
    • /
    • pp.257-265
    • /
    • 1996
  • 참개구리를 사용하여 난소내 여포들이 성장시기에 획즉하게 되는 스테로이드들의 생성능력을 조사하였다. 개구리로부터 중간(0.7-1.11mm) 크기 이하의 여포들을 분리한 다음 전구스테로이들이나 뇌하수체추출물(FPH)을 포함한 배양액에서 6시간 배양 후 이들에 의해 산물스테로이드로 전환된 양을 방사면역 측정법으로 조사하였다. FPH의 처리는 중간 크기의 여포만 스테로이드들의 생성을 현저히 촉진하고 작은 여포들(0.35-0.7mm)에서는 촉진효과가 매우 미약하였다. Progenenolone의 첨가는 가장 작은 여포 (0.22-0.4mm)들에 의해서도 progesterone(P$_4$)으로 전환되었다. 그러나 가장 작은 여포에서는 P$_4$를 첨가했을 때에도 역시 같은 현상이 나타났다. 작은 여포와 중간 여포들에 의한 전환된 스테로이드들의 양을 단위표면적의 전환량으로 계산 비교해 본 결과 전환된 양은 거의 같았다. 이는 작은 여포의 여포세포들 (granulosa cells)이 이미 E$_2$에 이르는 모든 중간 산물들을 생성할 능력을 가졌다는 것을 의미한다. 그러나 이들이 FPH에 의해서는 스테로이드를 조금밖에 생성하지 못하는 것으로 보아 아직 부족한 또다른 요인들이 있는것으로 추정된다.

  • PDF

소형제트를 이용한 과소팽창 음속 제트에서의 소음저감 (Noise Reduction of a Underexpanded Supersonic Jet via Steady Blowing with Microjets)

  • 김진화;김정훈;유정열
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.747-750
    • /
    • 2002
  • An attempt to reduce supersonic Jet noise is carried out by using two steady microjets in a round jet. The jet is issued from a round sonic nozzle with an exit diameter of 10mm. Two micro-nozzles with an inside diameter of 1mm each are installed on the exit plane with an off-axis angle of $45^{\circ}$. Far-field noise was measured at a location 40 diameters off the jet axis. The angles between a microphone and the jet axis are $45^{\circ}\;and\;90^{\circ}$. For an injection rate less than $1{\%}$ of the main jet, screech tones were completely suppressed by the microjets. The reduction in the ovelall sound pressure levels were $2.4\;and\;2.7\;dB\;for\;90^{\circ}\;and\;45^{\circ}$ directions, respectively. The enhancement of mixing/spreading of the jet by the microjet was negligible. The reduction of noise is probably due to distorted shock cell structures and/or broken large scale vortical structures by the microjets.

  • PDF

Application of epoxy putty external skeletal fixator for stabilization of tarsocrural arthrodesis in small dogs and cats

  • Moon, Je-Sung;Lee, June-Sub;Han, Hyun-Jung
    • 대한수의학회지
    • /
    • 제60권4호
    • /
    • pp.187-194
    • /
    • 2020
  • Two small-breed dogs and two cats, with an average body weight of 4.88 kg (range: 4.3-5.5 kg), suffered hindlimb lameness due to luxation with or without fractures of the tarsocrural joint. These patients underwent tarsocrural arthrodesis with epoxy putty external skeletal fixator. The animals' skins were incised minimally, and the articular cartilage of the tarsocrural joint was removed, followed by autogenous cancellous bone grafting. Epoxy putty and positive Centerface®, pins with diameters 1.2 mm and 2.0 mm, were used for connecting bar and as a full pin fixation, respectively. All the patients regained the ability to bear weight on the affected limb within 3-7 days and resumed a normal gait within 9-15 weeks. The external skeletal fixator frame was removed within 13-17 weeks without major complications. Tarsocrural arthrodesis using epoxy putty external skeletal fixator resulted in excellent outcomes without severe postoperative complications in this study. Epoxy putty external skeletal fixator can be a valuable surgical option for tarsocrural arthrodesis in patients weighing less than 5.5 kg.